Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AIR CONDITIONING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58Linked to original sources

A criterion for accurate aerosol sampling in calm air.

The problem of aerosol sampling under calm air conditions has been studied by solving the Navier-Stokes equations and integrating the equations of particle motion. Both particle inertia and settling are considered. The sampling efficiency of an inlet has been found to depend on two dimensionless parameters, the Stokes number and the relative settling velocity. A new criterion for accurate aerosol sampling in calm air is then derived. Experimental data of several researchers are discussed in the light of this new sampling criterion, and the data are found to be in accord with the theoretical predictions.

Air↗

Exposure to particulate matter, volatile organic compounds, and other air pollutants inside patrol cars.

People driving in a vehicle might receive an enhanced dose of mobile source pollutants that are considered a potential risk for cardiovascular diseases. The exposure to components of air pollution in highway patrol vehicles, at an ambient, and a roadside location was determined during 25 work shifts (3 p.m. to midnight) in the autumn of 2001, each day with two cars. A global positioning system and a diary provided location and activity information. Average pollutant levels inside the cars were low compared to ambient air quality standards: carbon monoxide 2.7 ppm, nitrogen dioxide 41.7 microg/m3, ozone 11.7 ppb, particulate matter smaller 2.5 microm (PM2.5) 24 microg/m3. Volatile organic compounds inside the cars were in the ppb-range and showed the fingerprint of gasoline. PM2.5 was 24% lower than ambient and roadside levels, probably due to depositions associated with the recirculating air conditioning. Levels of carbon monoxide, aldehydes, hydrocarbons, and some metals (Al, Ca, Ti, V, Cr, Mn, Fe, Cu, and Sr) were highest in the cars, and roadside levels were higher than ambient levels. Elevated pollutant levels were related to locations with high traffic volumes. Our results point to combustion engine emissions from other vehicles as important sources of air pollutants inside the car.

Air Pollutants↗

[Pollution of the workplace by anesthetic gases. Causes and prevention].

Waste anesthetic gas concentrations were measured in areas corresponding to the breathing zones of the anesthetists and operating room nurses for personal exposure (n = 27, time-weighted values) and during special work practices (n = 65). Leaks related to anesthetic machines and high-pressure nitrous oxide components were investigated during (n = 60) and after anesthesia (n = 85). The effect of a local scavenging system on occupational exposure during inhalation induction of anesthesia in children was studied (n = 60). Concentrations of nitrous oxide, halothane, isoflurane, and enflurane were determined by using active dosimeters (SKC 222) and different infrared gas-analyzers. Factors that increase waste anesthetic gas concentrations in operating rooms can be divided into several categories, such as low air conditioning systems, anesthetists' work practices, equipment leakage, including leakage from high-pressure nitrous oxide systems, and inadequate scavenging devices. Equipment leakage is almost invariably present in low-pressure components of the anesthesia machine because so many seals and joints are necessary to permit disassembly for cleaning and replacement. Waste anesthetic gases are also distributed in the exhaled air of patients recovering from anesthesia. To restrict the levels, exposure must be as low as can be achieved with reasonable efforts. Thus, the anesthetic equipment should be designed to avoid leakage, leakage tests should be performed before the use of anesthetic machines, and waste anesthetic gases should be scavenged by central as well as by local systems. Regular and periodic use of a trace gas analyzer permits direct observation of gas leakage and enables anesthetists to modify their work technique in order to reduce avoidable leakage.

Air Pollutants, Occupational↗

Sepsis rates in hip replacement surgery with special reference to the use of ultra clean air.

A study is reported of sepsis rates in 836 total hip replacements carried out in various physical environments including ultra-clean air. In a further sutdy the bacteriology of the air around the wound and of the wound itself was investigated during the course of 32 joint replacement operations with and without ultra-clean air. Bacteriological contamination of the air was markedly reduced by the use of ultra-clean air but the wounds themselves were no cleaner than with conventional air conditioning provided that unsterile personel were kept at least Imetri away from the sterile area. The sepsis rate was high at the outset of the study (when a physically apalling theatre was in use, the operative technique was novel and prophylactic antibiotics were not employed). Thereafter it fell and remained unchanged in spite of the introduction of ultra-clean air. We conclude that the efficacy of techniques amiced at sterilizing the air around the wound may now be unprovable in view of the low sepsis rates which can be obtained in a conventional environment. Our results do however show that unsterile personel should not be allowed to approach within Imetri of the sterile area, whatever venitlation is employed.

Air Microbiology↗

Mars analysis by laser-induced breakdown spectroscopy (MALIS): influence of mars atmosphere on plasma emission and study of factors influencing plasma emission with the use of doehlert designs.

A project called MALIS (Mars Analysis by Laser-Induced breakdown Spectroscopy) is under progress to perform in situ analysis of Mars soils and rocks. This paper reports on the behavior of plasma in Martian conditions, i.e., in a CO2 atmosphere at pressures between 5 and 12 mbar. Plasma expansion and lifetime have been studied in order to compare plasma evolution under standard conditions (air at atmospheric pressure) and in a Mars atmosphere. We have shown that the Mars environment favors plasma expansion and lifetime. The second part of the study concerns optimization of the emission signal from the plasma. An original approach has been chosen, as we used a Doehlert design for the first time in laser-induced breakdown spectroscopy (LIBS). The best conditions obtained are for a laser wavelength of 1064 nm with the maximum energy available due to space limitations, which is 40 mJ at 15 Hz. The other factors studied are delay, angle of incidence, and CO2 pressure. We have shown that these factors do not have the same influence depending on which spectroscopic line is used, i.e., the atomic line or the ionic line.

Atmosphere↗

Temporal changes in core body temperature in anesthetized adult horses.

OBJECTIVE: To examine temporal patterns of core body temperatures in adult horses during general anesthesia and to determine the efficacy of forced-air warming blankets in attenuating decreases in core body temperatures. ANIMALS: 5 clinically normal adult horses. PROCEDURE: Horses were assigned to each of 2 trials, warmer and no-warmer, in a randomized crossover design. Horses were instrumented with a thermistor-tipped pulmonary arterial catheter to measure core body temperature. Induction and maintenance of and recovery from general anesthesia were performed in an air-conditioned surgical suite where room temperature and relative humidity were maintained at approximately 21 C and 40%, respectively. Core body temperature measurements were recorded every 5 minutes during 2.5 hours of anesthesia and during recovery until horses could stand. Data were analyzed, using ANOVA for repeated measures. RESULTS: Without warming, mean core body temperature decreased steadily (0.37+/-0.18 C/h). Forced-air warming significantly decreased that rate to 0.19+/-0.09 C/h. In both trials, there was an additional, rapid, significant decrease in core body temperature when horses were moved to the recovery area, which was apparently the result of conductive heat loss to the cold floor. Recovery time and time required for core body temperature to return to baseline were unaffected by forced-air warming during anesthesia and recovery. CONCLUSIONS AND CLINICAL RELEVANCE: Core body temperature decreases steadily in adult horses anesthetized in a cool, dry environment. Forced-air warming devices can attenuate this decrease. Additional body heat can be lost rapidly when anesthetized horses are positioned on cold surfaces during recovery.

Analysis of Variance↗

The nasal cycle in respiratory defence.

The review describes the phenomenon of the nasal cycle, which consists of periodic congestion and decongestion of the nasal venous sinuses and an alternation of airflow from one side of the nose to the other over a period of several hours. The hypothesis is put forward that the nasal cycle may have a role in respiratory defence by; (a) alternation of the work of air conditioning between the nasal passages (b) generation of a plasma exudate which physically cleanses the epithelium and provides a source of antibodies and inflammatory mediators (c) maintaining the patency of the airway during the inflammatory response to infection.

Air↗

The influence of additives and metal rods on the nucleation and growth of gas hydrates.

A major technical issue in industrial applications of the gas hydrate storage process is to develop a practical means for rapid hydrate formation. In this paper, the formation processes of HCFC141b (CH(3)CCl(2)F) gas hydrate in a column of water with additives and with an iron rod that was placed in the center of the column have been studied to reveal the influence of the additives and the iron rod on the nucleation and growth of the gas hydrate. The water solution column, in a cylindrical glass container, was placed in a thermostatic bath at 274.15-280.15 K and under atmospheric pressure. The experimental results show that, compared to the pure water and the HCFC141b system, the properly placed iron rod combined with proper concentrations of lauryl sodium sulfonate, lauryl sodium sulfate, and sodium dodecylbenzenesulfonate-6 considerably reduces the hydrate nucleation time and promotes formation speed. The formation rate of HCFC141b gas hydrate increases with increasing concentration of sodium dodecylbenzenesulfonate-6 in the water solution, while the addition of potassium oxalate monohydrate in water has shown no effect on the nucleation and growth of HCFC141b gas hydrate. Under the experimental conditions, both the anion surfactants and the iron rod strongly induce the first nucleation of HCFC141b gas hydrate, while the following growth of the HCFC141b gas hydrate is primarily influenced by the anion surfactant. This experiment suggests a new way of fast formation of clathrate hydrate, which may be much easier for practical application of the gas hydrate for cold storage in air conditioning systems.

Journal Article↗

Particulate matter and polycyclic aromatic hydrocarbon concentrations in indoor and outdoor microenvironments in Boston, Massachusetts.

Estimating personal exposures to air pollution is a crucial component in identifying high-risk populations and determining efficient control strategies. Because of the difficulty of comprehensively measuring personal exposure, data on air pollution patterns in homogenous microenvironments linked with activity data are often used as surrogates. In this study, we focus on strengthening the available information about nonresidential microenvironmental exposures to particulate matter and other combustion pollutants. During the summer of 2000, we measured ultrafine particles, fine particulate matter (PM2.5), and particle-bound polycyclic aromatic hydrocarbons (PAHs) outdoors and in indoor microenvironments in Boston, Massachusetts. In indoor microenvironments averaged across sample days, mean ultrafine particle concentrations ranged from 3800 to 140,000 particles/cm(3), with 7-200 microg/m(3) of PM2.5 and 5-12 ng/m(3) of particle-bound PAH. PM2.5 indoor-outdoor ratios generally exceeded 1 in settings with high levels of human activity, with lower ratios for ultrafine particles. Cooking activities contributed significantly to elevated levels of all three pollutants. Using Linear Mixed Effects models with AR-1 autoregressive correlation structures, 10-min average outdoor concentrations were generally weak predictors of indoor levels, with stronger relationships in an apartment without mechanical ventilation than in air-conditioned nonresidential settings. Although further study would be needed to determine whether these patterns could be generalized beyond the monitored sites, these data support previous findings and enhance our knowledge about nonresidential exposure patterns.

Air Pollutants↗

Role of vasopressin in the cardiovascular response to hypoxia in the conscious rat.

Previous experiments have demonstrated that hypoxia stimulates the release of arginine vasopressin in conscious animals including the rat. The present study was designed to test whether AVP may exert a vasoconstrictor influence during hypoxia at varying levels of CO2. Systemic hemodynamics were assessed in conscious rats for 30 min under hypocapnic hypoxic, isocapnic hypoxic, hypercapnic hypoxic, and room air conditions. Progressive effects on heart rate (HR), cardiac output (CO), and total peripheral resistance (TPR) were observed with varying CO2 under hypoxic conditions. Hypocapnic hypoxia [arterial PO2 (PaO2) = 32 Torr; arterial PCO2 (PaCO2) = 22 Torr] caused HR and CO to rise and TPR to fall. Isocapnic hypoxia (PaO2 = 36 Torr; PaCO2 = 35 Torr) was associated with no significant changes in HR and CO or TPR, whereas hypercapnic hypoxia (PaO2 = 35 Torr; PaCO2 = 51 Torr) caused HR and CO to fall and TPR to rise. Room air time control experiments were associated with no change in measured hemodynamic variables. To determine the possible role of circulating AVP on these cardiovascular responses, additional experiments were performed where the specific V1-vasopressinergic antagonist d(CH2)5Tyr(Me)AVP (10 micrograms/kg iv) was administered at the midpoint of hypoxic exposure. Antagonist administration had no effect on hypocapnic hypoxic animals or animals breathing room air; however, blood pressure and TPR were significantly reduced by d(CH2)5Tyr(Me)AVP in both isocapnic and hypercapnic hypoxic animals. The heart rate response to hypoxia at the various CO2 levels was unaffected; however, cardiac output and stroke volume were increased after V1-antagonism in the isocapnic and hypercapnic hypoxic animals.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Aerosol generation by blower motors as a bias in assessing aerosol penetration into cabin filtration systems.

In cabin filtration systems, blower motors pressurize a vehicle cabin with clean filtered air and recirculate air through an air-conditioning evaporator coil and a heater core. The exposure reduction offered by these cabins is evaluated by optical particle counters that measure size-dependent aerosol concentration inside and outside the cabin. The ratio of the inside-to-outside concentration is termed penetration. Blower motors use stationary carbon brushes to transmit an electrical current through a rotating armature that abrades the carbon brushes. This creates airborne dust that may affect experimental evaluations of aerosol penetration. To evaluate the magnitude of these dust emissions, blower motors were placed in a test chamber and operated at 12 and 13.5 volts DC. A vacuum cleaner drew 76 m3/hour (45 cfm) of air through HEPA filters, the test chamber, and through a 5 cm diameter pipe. An optical particle counter drew air through an isokinetic sampling probe and measured the size-dependent particle concentrations from 0.3 to 15 microm. The concentration of blower motor aerosol was between 2 x 10(5) and 1.8 x 10(6) particles/m3. Aerosol penetration into three stationary vehicles, two pesticide application vehicles and one tractor were measured at two conditions: low concentration (outside in the winter) and high concentration (inside repair shops and burning incense sticks used as a supplemental aerosol source). For particles smaller than 1 microm, the in-cabin concentrations can be explained by the blower motor emissions. For particles larger than 1 microm, other aerosol sources, such as resuspended dirt, are present. Aerosol generated by the operation of the blower motor and by other sources can bias the exposure reduction measured by optical particle counters.

Aerosols↗

Atmospheric pressure laser desorption/chemical ionization mass spectrometry: a new ionization method based on existing themes.

We have designed and constructed an atmospheric pressure laser desorption/chemical ionization (AP-LD/CI) source that utilizes a laser pulse to desorb intact neutral molecules, followed by chemical ionization via reagent ions produced by a corona discharge. This source employs a heated capillary atmospheric pressure inlet coupled to a quadrupole ion trap mass spectrometer and allows sampling under normal ambient air conditions. Preliminary results demonstrate that this technique provides approximately 150-fold increase in analyte ions compared to the ion population generated by atmospheric pressure infrared matrix-assisted laser desorption/ionization (AP-IR-MALDI).

Air Pressure↗

Bronchial Rn dose survey for residences.

The bronchial dosimeter for Rn progeny proposed by Yu and Guan in 1998 was employed to survey the bronchial dose from Rn progeny in 30 residences in Hong Kong. An average bronchial deposition fraction of Rn progeny was obtained as 0.0334, which gave an average dose conversion factor (DCF) of 8.5 mSv WLM-1. The mean values of potential alpha energy concentration (PAEC) deposited in the tracheobronchial region (PAECT-B), total PAEC in air (PAECT), annual effective dose (E), concentration of Rn gas (RC) and annual dose conversion factor (ADCF) for all the residential sites combined were 0.11 +/- 0.05, 3.1 +/- 1.4 mWL, 1.2 +/- 0.5 mSv yr-1, 23 +/- 10 Bq m-3 and 0.055 +/- 0.020 (mSv yr-1 per Bqm-3), respectively, with air-conditioned sites (AC sites) and non-AC sites having significantly different mean ADCF values. The indoor relative humidity affected PAECT and RC with high confidence levels (> 95%).

Air Pollutants, Radioactive↗

The Leiden scavenging system: A simple and versatile apparatus to control air pollution in operating rooms.

A scavenging system which can be attached to a variety of anaesthetic machines and ventilators is described. Gas venting can occur via a central vacuum system, a suitable injector, fan or pump, through the exhaust duct of an air-conditioning system, or by a passive system. The resistance and back pressures applied to the anaesthetic apparatus are negligible. Leakage tests showed that the collected gases and vapours were substantially removed by the scavenging device.

Air Pollution↗

[Pollution of the work environment by volatile anesthetics and nitrous oxide].

Anaesthetic personnel is exposed to different workload conditions. The individual impact is influenced by external factors and human stress stability. Different symptoms reported to be present in anaesthetic personnel are comparable to symptoms of the sick building syndrome, defined by the WHO in the 90's. They are caused by work-induced distress and the exposure to chemical hazards. In anaesthesia, health defects by anaesthetic vapours and gases have been deplored for many years. After the Russian anaesthesiologist Vaisman published a report in 1967, controlled studies concerning cancerogenicity and teratogenicity of volatile anaesthetics under workspace conditions were carried out. In 1989, time-weighted average exposure threshold limit values of 5 ppm were released in the Federal Republic of Germany for halothane. In 1993 thresholds for enflurane (20 ppm) and nitrous oxide (100 ppm) were released. TLV concentrations for the new anaesthetic agents desflurane and sevoflurane have not yet been defined by authorities. Factors influencing workplace concentrations of anaesthetic gases are the anaesthetic procedures, apparatus leakage, air conditioning, fresh gas flow and the function of the scavenging system. Although cancerogenicity, mutagenicity, teratogenicity and reduction of fertility are discussed as effects of chronic exposure to anaesthetic gases, several review articles doubted the results of studies, finding positive correlations of incidence of occupational disease and the exposure to the volatile and gaseous substances. Mainly coexisting factors like smoke-induced exposure to polybromated biphenyls, disturbance in circadian rhythm, stress and enclosure in narrow exposure systems, increasing teratogenicity and cancerogenicity in animal experiments, are considered to promote unreliability of the studies. All reviewers do not discuss the fact, that all of these co-factors are present in the reality of the anaesthetic workplace. Thus, the studies by Corbett, enthusiastically criticized by different reviewers, simulate the all-day reality of the anaesthetic workplace more precisely than controlled experiments conducted, for example, by Eger and co-workers. The results of animal experiments and retrospective studies therefore do not justify realization of large controlled prospective studies but require the overall revision of the anaesthesiological workplace and the reduction of occupational waste gas exposure to the lowest possible levels below all chronic exposure threshold values.

Air Pollutants, Occupational↗

Effect of nedocromil sodium on exercise-induced bronchoconstriction exacerbated by inhalation of cold air.

This double-blind placebo-crossover study examined the effect of nedocromil sodium, 4 mg aerosol 30 min before challenge, on exercise-induced bronchoconstriction (EIB) in cold air conditions. Twenty-one asthmatic patients (15-28 years), with methacholine PC20 < or = 8 mg/ml in the absence of significant allergen exposure, were randomized to active and placebo therapy on separate study days. Pulmonary function, measured up to 20 min after exercise, showed significantly less deterioration with nedocromil sodium, which effectively halved the maximum percentage decline in forced expiratory volume in the first second. EIB was increased by cold air, whereas an ancillary study in 15 healthy volunteers (18-19 years) showed no such effects. We conclude that prior inhalation of nedocromil sodium diminished cold air-exacerbated EIB in young adult asthmatic patients.

Adolescent↗

Artichoke cultivars (var. "Blanca de Tudela") under elevated ozone concentrations.

Ozone concentrations rise to phytotoxic levels from spring to autumn at western Mediterranean basin coastal sites, where artichoke is one of the most important crops. Simultaneously, from year to year and especially since the early 1980s, resprouting of the stumps has been decreasing in Valencian Community artichoke plantations. To see if ozone might be playing a role in this decrease, a number of plants were exposed to different levels of ozone. Results of the ozone treatments showed reduced biomass in the offshoots of plants exposed to the highest ozone treatment. The exposure to ambient ozone during the stump-establishment period, when compared to filtered-air conditions, resulted in a reduction in yield when plants were transplanted in the field under ambient ozone concentrations. And when plants were exposed to acute short picks, typical ozone visual injury appeared in the older leaves.

Agriculture↗

Monitoring of bacterial sugars and hydroxy Fatty acids in dust from air conditioners by gas chromatography-mass spectrometry.

Bacterial levels in dust collected from hospital air-conditioning filters were examined by chemical analysis (without prior culture). The dust was analyzed by gas chromatography-mass spectrometry after hydrolysis and derivatization. l-Glycero-d-mannoheptose and hydroxy fatty acids (3-OH 12:0 and 3-OH 14:0) (primarily found in lipopolysaccharide) and muramic acid (a chemical marker for bacterial peptidoglycan) were present at higher levels in dust collected from filters primarily contacting outdoor (as opposed to indoor) air. The ratio of l-glycero-d-mannoheptose to muramic acid in dust (compared with those of a group of gram-positive and gram-negative bacteria) suggested that both dust types contained appreciable numbers of gram-negative bacteria. There is potential for the chemical assessment of the microbial content of airborne dust.

Journal Article↗