Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “phasing”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57Linked to original sources

Capillary electrochromatography in anion-exchange and normal-phase mode using monolithic stationary phases.

Hydrophilic macroporous weak and strong anion-exchange stationary phases have been prepared in a monolithic format within untreated fused-silica capillaries by the simple thermally or UV-initiated polymerization of 2-dimethylaminoethyl methacrylate, 2-hydroxyethyl methacrylate and ethylene dimethacrylate in the presence of a binary porogenic mixture of dodecanol and cyclohexanol. The tertiary amino functionalities were then alkylated in situ to afford strong anion-exchangers. These new monolithic stationary phases with optimized porous properties were used for the CEC separation of various organic anions. Thus, a mixture of 2-substituted propionic acid drugs (profens) was separated in 13 min and high column efficiencies of up to 231,000 plates/m were achieved. The separation of substituted benzoic acids indicates that the selectivity results primarily from the anion-exchange interactions, while electrophoretic migration contributes only slightly. In addition, these hydrophilic anion-exchangers are also able to separate weakly acidic, neutral and basic compounds such as phenols, xanthines and aromatic amines in normal-phase electrochromatographic mode.

Anion Exchange Resins↗

Impact of triethylamine as a mobile phase additive on the resolution of racemic amino acids on an (+)-18-crown-6-tetracarboxylic acid-derived chiral stationary phase.

Recently, a new HPLC chiral stationary phase (CSP) prepared by covalently bonding (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid on silica gel was successfully employed in resolving various racemic natural and unnatural amino acids containing a primary amino group. Current work details on-going efforts to improve the effectiveness of this type of material. The analytes used in this study included various substituted phenylalanines, phenylglycine homologues and other primary amino acids. In an attempt to increase enantioselectivity, the effect of methanol and triethylamine modifiers was evaluated in an aqueous mobile phase containing sulfuric acid. In general. retention time increased with increasing methanol and triethylamine concentration. In addition, highest enantioselectivities were obtained with high methanol and high triethylamine; however, these conditions produced excessively long retention. All of the analytes were well resolved on the CSP with a mobile phase of 20% methanol containing 14.3 mM triethylamine and 10.0 mM sulfuric acid.

Amino Acids↗

Characterization of alkyl polyglycosides by both reversed-phase and normal-phase modes of high-performance liquid chromatography.

Alkyl polyglycosides today represent the most important sugar surfactant. Nonionic sugar surfactants produced via different synthetic routes are mixtures of alkyl homologues, oligomers, anomers and isomers. Alkyl homologues and oligomers of alkyl mono- and diglucosides were separated by reversed-phase high-performance liquid chromatography (HPLC) with methanol-water as the mobile phase using a gradient elution. The gradient was optimized in respect to a simultaneous separation of alkyl glycosides according to their alkyl chain length and alkyl polyoxyethylene glucosides with regard to their length of the polyoxyethylene spacer. The separation of alkyl glycosides into alpha- and beta-anomers was carried out by normal-phase HPLC with isooctane-ethyl acetate (60:40, v/v)-2-propanol in the gradient mode. Light scattering detection was used. Matrix-assisted laser desorption ionization time-of-flight mass spectra of alkyl glucosides and dodecyl glucosides with oxyethylene spacer groups are presented.

Carbohydrate Sequence↗

Chiral separations of cationic and anionic drugs on an alpha 1-acid glycoprotein-bonded stationary phase (EnantioPac). II. Influence of mobile phase additives and pH on chiral resolution and retention.

The influence of mobile phase additives and pH on chiral resolution and retention on a high performance liquid chromatographic chiral stationary phase composed of alpha 1-acid glycoprotein bonded to diethylaminoethyl silica (EnantioPac) has been investigated. Cationic and anionic compounds of widely differing structures were chromatographed and drastic effects on stereoselectivity were observed with hydrophobic charged modifiers. For cationic solutes, a decrease in the pH of the mobile phase from 7.0 to 6.0 gave reduced retention and, in some cases, improved selectivity when tetrabutylammonium or tetrapropylammonium bromide was used as modifier. For anionic solutes, a pH decrease from 6.6 to 6.1 gave enhanced retention but without a significant change in stereoselectivity. The steric bulk and hydrophobic moieties of the solute seem to have a strong influence on chiral selectivity. Widely different separating efficiencies were obtained with molecules of different structures.

Alcohols↗

Silica versus polymer-based stationary phases for reversed-phase high-performance liquid chromatographic analyses of rat insulin biosynthesis. A comparison of resolution and recovery.

Because of the problems caused by the irreversible binding of insulins and proinsulins to several silica-based reversed-phase columns, the use of polymeric reversed-phase columns was investigated for the analysis of rat islet polypeptides involved in insulin biosynthesis. No irreversible binding of insulins and proinsulins was observed for the polymeric reversed-phase columns, probably due to the absence of silanol groups. The six polypeptides involved in insulin biosynthesis in rat islets were equally well resolved in shallow trifluoroacetic acid-acetonitrile gradients on the silica-based Nucleosil 300-5C4 column (45 degrees C), the polymer-based Asahipak C4P-50 (25 and 45 degrees C), and ODP-50 columns (45 degrees C). In shallow triethylammonium phosphate-acetonitrile gradients (25 degrees C) satisfactory resolution of the two rat proinsulins was only obtained on the polymer-based Asahipak C4P-50 and C8P-50 columns. Increasing the separation temperature to 45 degrees C improved the separation of the two insulins and the two proinsulins in all cases. The shifts in retention times for the individual islet polypeptides observed in relation to the increased separation temperature were found to be different for the silica C4 and the polymer C4 columns. Recoveries of rat islet polypeptides were comparably high from the silica- and the polymer-based C4 columns and linear load-response curves were obtained in the microgram to picogram mass range on both columns.

Animals↗

Selective stationary phase for solid-phase microextraction analysis of sarin (GB).

A number of critical field applications require monitoring air samples for trace levels of chemical warfare agents. Solid-phase microextraction (SPME) is a convenient format to conduct these analyses. Measurements could be significantly improved if a SPME phase selective for nerve agents were substituted for non-selective polymers typically used (e.g., polydimethylsiloxane). This paper evaluates a novel stationary phase, previously developed for methylphosphonate sensor applications, for use with SPME sampling. The phenol-based polymer, BSP3, was found to offer far higher selectivity toward sarin (GB) than polydimethylsiloxane due to a pronounced affinity toward the target analyte and a lower affinity toward hydrocarbons.

Air↗

Reversed-phase liquid chromatography on an amide stationary phase for the determination of the B group vitamins in baby foods.

A liquid chromatographic method for the separation and determination of several water-soluble vitamins of the B group is proposed. The procedure is based on the use of a new amide-based stationary phase, which avoids the need of using the ion-pair technique, leading to narrower peaks and a simpler mobile phase. Analyses were performed by gradient elution with acetonitrile-phosphate buffer as mobile phase and using a photodiode array detector. Specificity was demonstrated by the retention characteristics, UV spectra and by comparing the peak purity index with commercial standards. Linearity, precision, recovery and sensitivity were satisfactory. The vitamins are extracted from the baby food using a single digestion with hydrochloric acid followed by enzymatic digestion with taka-diastase. The method was successfully applied to the determination of nine vitamins: thiamine, riboflavin, nicotinamide, nicotinic acid, pyridoxine, pyridoxal, folic acid, cyanocobalamine and inosine in different baby foods as infant formulas, cereals and fruit products. Validation was performed using two certified reference materials.

Amides↗

Determination of glycolic acid in cosmetic products by solid-phase extraction and reversed-phase ion-pair high-performance liquid chromatography.

A procedure has been developed for the assay of glycolic acid in cosmetic products by reversed-phase high-performance liquid chromatography using an ion-pairing method. After dissolution in tetrahydrofuran-water (90:10, v/v), samples were purified by solid-phase extraction using silica-based strong anion-exchange cartridges and analysed directly on an Ultrasphere ODS column with UV detection at 210 nm and methanol-phosphate buffer (2:98, v/v), containing tetrabutylammonium iodide, as the mobile phase. Recovery of glycolic acid from different cosmetic matrices was between 92.4 and 96.2% and the precision of the method was better than 5.4% relative standard deviation. The procedure is rapid, simple, selective and it is suitable for routine analyses of commercial cosmetics.

Buffers↗

Retention behavior of D,L-dansyl-amino acids on a human serum albumin chiral stationary phase: effect of a mobile phase modifier.

The effect of perchlorate anion as a mobile phase modifier on the retention of dansyl norvaline and dansyl tryptophan enantiomers on a human serum albumin (HSA) column was studied by varying the chaotropic agent concentrations. The thermodynamic parameters for the transfer of a solute from the mobile to the HSA stationary phases were determined from linear van't Hoff plots. An enthalpy-entropy compensation study revealed that the type of interaction between the solute and HSA was independent of the molecular structure. The parabolic variations observed with the enthalpic and entropic terms of dansyl amino acid transfer in relation to the concentration of perchlorate anion were considered to be the result of the change from reversed to normal-phase conditions for this chromatographic system.

Amino Acids↗

Stationary phase deletions in Escherichia coli. II. Mutations which stimulate stationary phase deletions in plasmid pMC874.

Deletions in the plasmid pMC874 take place in resting cells incubating on McConkey's or minimal lactose agar and are time rather than generation dependent. These deletions join the km(r) promoter to a promoterless lac operon giving rise to Lac(+) papillae on McConkey's lactose agar, and can occur in the absence of sequence homologies such as direct or inverted repeats. Using this as a selective screen we isolated 31 mutants designated dli (for deletion increase), which enhanced to different extents the frequency of this unusual class of deletions. Six of these were characterized by phenotypic tests and their ability to stimulate other deletion events such as the excision of Tn10 from various chromosomal sites and the loss of cloned fragments between two EcoR1 sites in the gene for chloramphenicol resistance (cat) of plasmid pBR325. Two of them showed contrasting phenotypes and were studied further: one (dli1) stimulated Lac(+) deletions in pMC874 in resting cells but not Tn10 excision from chromosomal locations in log phase cells, and the other one (dli2) did exactly the reverse, i.e. it enhanced Tn10 excision but not Lac(+) deletion incidence. Mapping and complementation tests showed that dli1 is a null mutation in recC and was renamed recC2251. This is strong evidence that resting phase deletions in pMC874 are stimulated by the absence of a functional RecBCD enzyme. The dli2 mutation was identified by mapping and phenotypic tests as a mutation in uvrD, the gene for helicase II, and it was tentatively designated uvrD(-)dli2. These results show that (1) pMC874 is an excellent system to select mutants for genetic functions involved in the generation of resting phase deletions, and (2) there are at least two major deletion pathways in E. coli, one active in resting and the other in actively dividing cells.

Agar↗

The suppression of T cell apoptosis influences the severity of disease during the chronic phase but not the recovery from the acute phase of experimental autoimmune encephalomyelitis in mice.

The elimination of T cells by apoptosis is considered to be one of the regulatory factors in experimental autoimmune encephalomyelitis (EAE), an animal model of multiple sclerosis. To address further the role of apoptotic T cell death in EAE, we investigated myelin oligodendrocyte glycoprotein (MOG)-induced EAE in transgenic mice overexpressing the anti-apoptotic gene, bcl-2, in T cells. During the acute phase of EAE, no significant difference was observed in the clinical course, pathology and T cell response to MOG between bcl-2 transgenic mice and wild-type littermates. While the recovery from the first attack of EAE was not impaired in the bcl-2 transgenic mice, a more severe disease was observed during the chronic phase of the disease even though T and B cell responses to MOG were comparable to those of wild-type littermates. A flow cytometric analysis by Annexin V showed a significant decrease of apoptotic T cells in the central nervous system (CNS) of the bcl-2 transgenic mice with EAE compared with controls during the chronic as well as the acute phase of disease. These results suggest that while T cell apoptosis in the CNS may play a regulatory role in EAE, the spontaneous recovery from acute EAE cannot solely be explained by T cell apoptosis.

Acute Disease↗

The start of the quiescent period of cortisol remains phase locked to the melatonin onset despite circadian phase alterations in humans working the night schedule.

Using a 10-min blood sampling procedure, we established 24-h plasma melatonin and cortisol rhythms in 11 night workers and determined whether the extent in the shift of the melatonin onset, highly variable among night workers, was reflected in the shift of the markers of the cortisol rhythm, i.e. the quiescent period of secretion and the acrophase. In all day-active subjects, the melatonin onset occurred during low cortisol secretion, with a time lag between the start of the quiescent period and the melatonin onset of 1 h 28+or-27 min. In night workers, whatever the shift of the melatonin surge, the start of the quiescent period of cortisol secretion remained phase locked to the melatonin onset with a similar time lag (1 h 25+or-27 min). There was a significant correlation between the timing of the melatonin onset and the timing of the start of the quiescent period (r=0.88; P=0.0072). No preserved time lag was found between the melatonin onset and the other cortisol phase markers, either with the end of the quiescent period or with the acrophase. These results settle the start of the quiescent period of cortisol and the melatonin onset as two coordinate markers, and suggest that each of them are reliable to assess circadian phase in humans.

Adaptation, Physiological↗

Determination of propafenone and its phase I and phase II metabolites in plasma and urine by high-performance liquid chromatography-electrospray ionization mass spectrometry.

A sensitive method was developed to determine propafenone, 5-hydroxypropafenone, N-despropylpropafenone and propafenone glucuronides in human plasma and urine by HPLC-electrospray ionization mass spectrometry with the respective deuterated analogues as internal standards. The analytes were extracted by a single solid-phase extraction, collecting two fractions, one containing the glucuronides and the other propafenone and the phase I metabolites 5-hydroxypropafenone and N-despropylpropafenone. The mobile phases used for HPLC were: (A) 5 mM ammonium acetate in water and (B) 5 mM ammonium acetate in methanol-tetrahydrofuran (50:50, v/v). Separation of the diastereoisomeric propafenone glucuronides was achieved on a Spherisorb ODS 2 column (150 x 2.0 mm I.D., particle size 5 microm) at a flow-rate of 0.3 ml/min using a linear gradient from 20% B to 50% B in 15 min. For separation of propafenone, 5-hydroxypropafenone and N-desalkylpropafenone a linear gradient from 50% B to 80% B in 10 min was employed. The mass spectrometer was operated in the selected ion monitoring mode using the respective MH+ ions for quantification. The limits of quantification achieved with this method were 10 pmol/ml for propafenone, 5-hydroxypropafenone, R- and S-propafenone glucuronide and 20 pmol/ml for N-desalkylpropafenone using 0.5 ml of plasma. Reproducibility and accuracy was below 12% for each analyte over the whole concentration range measured. The method was applied to a pharmacokinetic study assessing the influence of rifampicin on propafenone disposition.

Chromatography, High Pressure Liquid↗

High-performance liquid chromatographic separation of inositol phosphate isomers employing a reversed-phase column and a micellar mobile phase.

Surfactants have been employed in high-performance liquid chromatography (HPLC) for the separation of ionic and non-ionic compounds. We have developed a method employing a reversed-phase column and a mobile phase containing a surfactant, hexadecyltrimethylammonium hydroxide (HDTMA+OH-), for the separation of several inositol phosphate positional isomers. Various parameters were studied for their effect on the chromatographic capacity factor (k'). They included the concentration of HDTMA+OH-, the pH of the bulk micellar suspension and the addition of inorganic salts to the mobile phase. Resolution of the inositol monophosphates was controlled by a mixed mechanism, where the predominant elements were electrostatic forces and the formation of micelles. The elution of the inositol polyphosphate isomers was obtained by increasing the amount of a non-polar solvent, in agreement with an ion-pairing process. This method represents an alternative to ion-exchange HPLC. If offers a practical advantage when detection of radiolabeled samples by in-line radioactive flow detectors is required, because low-quenching solvents with good miscibility with scintillant fluids are employed. The analysis of various chromatographic conditions, the system reproducibility and its application to the analysis of biological samples are described.

Chromatography, High Pressure Liquid↗

Stereoselective determination of mepivacaine in human serum using a brush-type chiral stationary phase and solid-phase extraction.

A stereoselective high-performance liquid chromatography assay method was developed for the quantitation of R-(+)- and S-(-)-mepivacaine in human serum. The assay uses a Pirkle brush-type (S)-tert.-leucine, (R)-1-(alpha-naphthyl)ethylamine stationary phase (Sumichiral OA-4700, 250 x 4 mm I.D.) at ambient temperature with a mobile phase of hexane-ethylenedichloride-absolute methanol (85:10:5, v/v) for the separation of R-(+)- and S-(-)-mepivacaine. The eluents were monitored using UV detection at 220 nm. Isolation of the analytes from serum was performed using a 1-ml C18 solid-phase extraction cartridge with high recovery and selectivity. The detection limits were 100 ng/ml for each enantiomer and the limits of quantitation were 150 ng/ml for both enantiomers. Linear calibration curves in the 150-2400 ng/ml range showed good correlation coefficients (r > 0.9994, n = 3). Precision and accuracy of the method were within 2.1-5.3 and 2.0-3.6%, respectively, for R-(+)-mepivacaine and 2.7-5.7% and 1.7-4.2%, respectively, for S-(-)-mepivacaine.

Anesthetics, Local↗

Preparation of (R)-N-methylsalsolinol via reversed-phase high-performance liquid chromatography using beta-cyclodextrin as a mobile-phase additive.

A new preparation method was devised using beta-cyclodextrin as a mobile-phase additive in a reversed-phase high-performance liquid chromatography system. Preparative separation of the biologically active (R)-enantiomer was achieved from racemic N-methylsalsolinol. Beta-cyclodextrin was removed completely in good yield by acid extraction and solid-phase extraction. By a slight modification, this method will be applicable to the isolation of various types of biologically important enantiomers.

Chromatography, High Pressure Liquid↗

Variation of penicillin acylase partition coefficient with phase volume ratio in poly(ethylene glycol)-sodium citrate aqueous two-phase systems.

The influence of phase volume ratio on partition and purification of penicillin acylase from Escherichia coli on poly(ethylene glycol)-sodium citrate aqueous two-phase systems was studied. In PEG 1000 systems both partition coefficients of the enzyme and total protein increased with decreasing phase volume ratio. However, in PEG 3350 containing NaCl, penicillin acylase follows a reverse trend, while total protein behaves in the same way. Implications for protein purification designs are discussed.

Chemistry Techniques, Analytical↗

Enantioselective analysis of propafenone in plasma using a polysaccharide-based chiral stationary phase under reversed-phase conditions.

We present a method for the enantioselective analysis of propafenone in human plasma for application in clinical pharmacokinetic studies. Propafenone enantiomers were resolved on a 10-microm Chiralcel OD-R column (250 x 4.6 mm I.D.) after solid-phase extraction using disposable solid-phase extraction tubes (RP-18). The mobile phase used for the resolution of propafenone enantiomers and the internal standard propranolol was 0.25 M sodium perchlorate (pH 4.0)-acetonitrile (60:40, v/v), at a flow-rate of 0.7 ml/min. The method showed a mean recovery of 99.9% for (S)-propafenone and 100.5% for (R)-propafenone, and the coefficients of variation obtained in the precision and accuracy study were below 10%. The proposed method presented quantitation limits of 25 ng/ml and was linear up to a concentration of 5000 ng/ml of each enantiomer.

Anti-Arrhythmia Agents↗