Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Spectral estimation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57Linked to original sources

Heritability of bipolar EEG spectra in a large sib-pair population.

The additive genetic heritability of both monopolar and bipolar EEG spectral power in a sample of 305 non-twin sibships comprising 690 individuals (age range 7-65) was estimated in order to investigate their regional variation. The heritabilities of the bipolar EEG spectral power ranged from 0.10 to 0.63 in 38 electrode-pairs, and those of monopolar power ranged from 0.23 to 0.68 in 19 electrodes in six frequency bands from theta to high beta. The bipolar data shows significantly greater topographic variation compared to that of the monopolar data. The mean of bivariate genetic correlations were consistently lower for the bipolar data and the coefficients of variation consistently higher when compared to those of the monopolar data for each of the frequency bands. The results from the bipolar derivations are in greater accord with genetic findings in brain anatomy and show the possibility of multiple genetic sources for the phenotypic variability of EEG activity.

Alpha Rhythm↗

Extension of fourier transform vibrational circular dichroism into the near-infrared region: continuous spectral coverage from 800 to 10 000 cm(-1).

We report the first vibrational circular dichroism (VCD) spectra with continuous coverage from 800 cm(-1) in the mid-infrared (MIR) region to 10 000 cm(-1) in the near-infrared (NIR) region. This coverage is illustrated with MIR and NIR absorbance and VCD spectra of 2,2-dimethyl-dioxolane-4-methanol (DDM), alpha-pinene, and camphor that serve as calibration samples over this entire region. Commercially available, dual-source Fourier transform (FT) MIR and NIR VCD spectrometers were equipped with appropriate light sources, optics, and detectors, and were modified for dual-polarization-modulation (DPM) operation. The combination of liquid-nitrogen- and thermoelectric-cooled HgCdTe (MCT) detectors, as well as InGaAs and Germanium (Ge) detectors operating at room temperature, permitted collection of the desired absorbance and VCD spectra across the range of vibrational fundamental, combination band, and overtone frequencies. The spectra of DDM and alpha-pinene were measured as neat liquids and recorded for both enantiomers in the various spectral regions. Spectra for camphor were all measured in CCl(4) solution at a concentration of 0.6 M, except for the carbonyl-stretching region, where a more dilute concentration was used. The typical anisotropy ratios (g) of the three molecules were estimated with respect to their strongest VCD bands in each spectral region. It was found that for all three molecules in the spectral regions above 2000 cm(-1), anisotropy ratios are approximately the same order (10(-5)) of magnitude. However, in the MIR region, the typical anisotropy ratios are significantly different for the three molecules. This study demonstrates that with modern FT-VCD spectrometers modified for DPM operation, VCD spectra can be measured continuously across a wide spectral range from the MIR to nearly the visible region with an unsurpassed combination of signal-to-noise ratio and spectral resolution.

Bicyclic Monoterpenes↗

Spectral analysis of short-term heart rate variability in diabetic patients.

Spectral analysis of short term R-R variability estimated by autoregressive modelling is a recently developed method for the evaluation of cardiovascular autonomic function. This new test also allows to study the interaction on heart rate variability of parasympathetic and sympathetic system. The sensitivity of the method for detection of cardiovascular autonomic neuropathy has been evaluated in a group of diabetic patients in comparison with the sensitivity of a battery of the most commonly used cardiovascular autonomic tests (deep-breathing, lying-to-standing, Valsalva Manoeuvre, postural hypotension and hand grip). Spectral analysis of heart rate variability resulted in a very sensitive method for early detection of diabetic autonomic neuropathy, about one-fourth of diabetic patients with normal traditional cardiovascular autonomic tests had abnormal results at spectral analysis. Both sympathetic and vagal control of heart rate resulted alterated in diabetic autonomic neuropathy.

Adult↗

Multiple quantum and high-resolution NMR, molecular structure, and order parameters of partially oriented ortho and meta dimethyl-, dichloro-, and chloromethylbenzenes codissolved in nematic liquid crystals.

We develop a strategy for analyzing complex nuclear magnetic resonance (NMR) spectra of several solutes codissolved in liquid-crystal phases. Spectral parameters of solutes m- or o-xylene were estimated by analyzing 2D multiple-quantum NMR spectra using a modified version of a least-squares fitting routine which adjusts chemical shifts, order parameters, structural parameters, and/or dipolar couplings independently. These estimates were used to facilitate analysis of the high-resolution spectra which contain resonances from many solutes. Calculated spectra of m- or o-xylene were subtracted from the experimental high-resolution spectra leaving resonances from the other solutes readily visible. Accurate spectral parameters of all codissolved solutes were determined from the high-resolution spectra. Order parameters and structural parameters (including vibrationally corrected parameters) of m- and o-xylene, m- and o-chlorotoluene, and m- and o-dichlorobenzene were calculated from the dipolar couplings.

Benzene↗

Environmental semivolatiles and nonvolatiles analysis by hyphenated spectral techniques.

Environmental sample extracts contain a variety of volatile and nonvolatile organic compounds exhibiting a range of polarities and concentrations. Although gas chromatography/mass spectrometry (GC/MS) is the method of choice thus far for such analyses, this technique used alone cannot adequately characterize the volatiles in such samples and is not amenable to environmental nonvolatiles. A more complete characterization of environmental and hazardous waste samples is required to assess the dangers posed to the nation's groundwater by hazardous waste dumps. Online spectral confirmation by directly linked GC/Fourier transform infrared (FTIR)/MS is shown to provide useful structural information on environmental volatiles in hazardous wastes, even when the analyte's spectrum is not in either spectral database. This information can lead to biological-hazard estimation. The diffuse reflectance Fourier transform infrared (DRIFT) technique, used in conjunction with thermospray MS or fast atom bombardment (FAB) MS, provides confirmed identifications or confirmed compound class assignments of organic nonvolatiles in solid wastes. This is believed to be the first report of spectral confirmation (identification or functionality) of organic volatiles and nonvolatiles in environmental samples.

Air Pollutants↗

Ozone depletion and increase in annual carcinogenic ultraviolet dose.

An increase in skin cancer incidence due to an increase of solar ultraviolet (UV) radiation is one of the best quantitated effects of stratospheric ozone depletion. Until now, estimates of effective UV dosages could not be based on spectral data on carcinogenicity. Instead the spectral dependence of sunburn or mutations was used. These data contained little information on longwave ultraviolet radiation (UVA: 315-380 nm). Recently, in hairless mice, experimental data have become available on the carcinogenic effectiveness of the ultraviolet, including UVA. From these new data we can estimate the effect of ozone depletion on the ambient annual carcinogenic UV dose. We find that a 1% decrease in ozone yields a 1.56% increase in annual carcinogenic UV; this value is not strongly dependent on geographical latitude. From this result, combined with the dose-response relationship for UV carcinogenesis, we conclude that for a 1% decrease in total column atmospheric ozone an increase of 2.7% in non-melanoma skin cancer is to be expected.

Humans↗

Mucosal exposure to light during routine endoscopy.

BACKGROUND: The spectral irradiance delivered by a variety of gastrointestinal endoscopes was measured as a function of wavelength and used to estimate the amount of light delivered to the mucosal surface during routine endoscopic procedures. METHODS: Spectral irradiances from seven different endoscopes were measured using a commercial spectroradiometer calibrated against a National Institute of Standards and Technology traceable source. RESULTS: The largest maximum irradiance was 8.0 W/cm2 obtained from an endoscope used in transillumination mode. In the typical viewing mode, the largest maximum irradiance measured was 1.6 W/cm2. The majority of the light energy delivered by these gastrointestinal endoscopes was in the visible wavelength region (400 to 700 nm). DISCUSSION: The measurements revealed surprisingly high light exposures in the visible wavelength range. In fact, the estimated tissue exposures can exceed by 40-fold the standards established for skin exposure to light set forth by the American National Standards Institute. Because gastrointestinal endoscopy is widely viewed to be safe, it is probable that the gastrointestinal tract has significant tolerance to light exposure.

Calibration↗

Energy migration and trapping in a spectrally and spatially inhomogeneous light-harvesting antenna.

In this paper, we analyze the process of excitation energy migration and trapping by reaction centres in photosynthesis and discuss the mechanisms that may provide an overall description of this process in the photosynthetic bacterium Rhodospirillum (Rs.) rubrum and related organisms. A wide range of values have been published for the pigment to pigment transfer rate varying from less than 1 ps up to 10 ps. These differences occur because the interpretation of trapping measurements depend on the assumptions made regarding the organization of the photosynthetic system. As we show, they can be reconciled by assuming a spatially inhomogeneous model where the distance of the reaction center to its surrounding pigments is larger than the pigment-pigment distances within the antenna. We estimate their ratio to be 1.7-1.8. The observed spectral inhomogeneity (at low temperature) of the photosynthetic antenna has resulted in various models. We demonstrate that the excitation kinetics can be modelled at all temperatures by assuming an inhomogeneous distribution of spectral shifts for each pigment. A transition temperature can be distinguished where the effects of spectral inhomogeneity become apparent and we discuss the ranges above (e.g., room temperature), around (e.g., 77K) and below (e.g., 4K) this temperature. Although the basic model is the same in all cases, the dominant mechanism differs in each range. We present explicit expressions for the exciton lifetime in the first two cases and demonstrate that at both temperatures the transfer rate from the light-harvesting antenna to the special pair of the reaction center is the rate-limiting step. Furthermore we demonstrate that at all temperatures a finite number of functional "levels" can be distinguished in the spectral distribution. At high temperature all pigments can be considered spectrally identical and only one level is needed. In the intermediate range a blue-shifted fraction is necessary. At low temperature a third redshifted fraction must be introduced.

Biophysical Phenomena↗

Time-variant spectral analysis of LDF signals on the basis of multivariate autoregressive modelling.

Time-variant AR-modelling was used to analyse the non-stationary properties of LDF signals during provocation tests. The procedure for the estimation of time-varying AR parameters based on Kalman filtering is presented. The estimates can be used to calculate instantaneous measures, such as peak frequency, spectral band power and coherence. The resulting course of instantaneous peak frequency of a sinusoidal signal with frequency jump was compared to similar parameters derived from short-time FFT and Hilbert transformation. Univariate time-variant spectral analysis was used to investigate LDF measurements in patients with Raynaud's phenomena. The experimental protocol was splitted into phases of different room temperature. The results demonstrate time-dependent variations of spectral components (amplitude and frequency). By means of time-variant coherence analysis of LDF and diameter measurements of vessels in a hamster skin fold the existence of a main rhythm around 0.1 Hz in the LDF signals which is related to vasomotion is shown.

Algorithms↗

Anomalous auditory filter bandwidth derived from direct masking of complex signals.

Psychoacoustical thresholds were determined for complex signals (triangular spectral envelope and 2000-Hz center frequency) masked by broadband noise. Variation of the fundamental frequency and of the phase relation between the components had no influence on the masked thresholds, although the temporal envelopes of the complexes were completely different. The bandwidth of the signals was varied by changing the slope of the spectral envelopes. From the dependence of the masked threshold on signal bandwidth the auditory filter bandwidth was estimated to be about 100 Hz at 2000 Hz. Masked thresholds determined for complexes with flat spectral envelope resulted in the same auditory filter bandwidth. These values are extremely narrow compared to the value of about 320 Hz often observed in other measures. It is suggested that the masked thresholds are influenced by temporal interactions.

Acoustics↗

[Analysis of the biorhythm frequency of bordered enterocytes during normal and inverted feeding regimens].

The study was performed during the period close to equinox in 236 male mice C57 Bl strain, sacrificed at equal intervals during 5 days. In paraffin sections, 5--6 mcm thick, stained after Dominici-Kedrovsky, with additional application of PAS-reaction and alcian blue, the cell height and width in the small intestine border enterocyte zone were determined. Calculation of autocorrelative function with the following determination of spectral density, infradian, circadian and ultradian biorhythmical components were estimated, as well as their changes under the influence of feeding regime inversion. At evening feeding, the greatest width of the brush border coinsides the beginning and the end of the digestion period. The width of the dark apical zone, where mitochondria are concentrated, synchronously changes at the end of digestion with the brush border, and then- with the cell basal zone. At morning feeding, by the degree of circadian phase change, the most liable are the indices reflecting organoid status, which are closely involved in absorbtion processes. Ultradian rhythm produces, on the background of circadian changes, additional raisis and abatements. Spectral composition, under inadequate feeding, is demonstrated to become more complex, mainly at the expense of ultradian rhythms, that speaks of their importance for the processes of adaptive rhythmical rearrangement.

Animals↗

Comparison of heart rate variability analysis methods in patients with Parkinson's disease.

The aim of the present study was to evaluate different analysis methods for revealing heart rate variability (HRV) differences between untreated patients with Parkinson's disease and healthy controls. HRV in standard cardiovascular reflex tests and during a 10 min rest period were measured by time- and frequency-domain and geometrical and non-linear analysis methods. Both frequency- and time-domain measures revealed abnormal HRV in the patients, whereas non-linear and geometrical measures did not. The absolute high-frequency spectral power of HRV was the strongest independent predictor to separate the patients from the controls (p = 0.001), when the main time-domain and absolute frequency-domain measures were compared with each other. When the corresponding normalised spectral units, instead of the absolute units, were used in the comparison, the two best single measures for separating the groups were the 30/15 ratio of the tilting test (p = 0.003) and the max/min ratio during deep breathing (p = 0.024). When the correlations between the different measures were estimated, the time-domain measures, fractal dimension and absolute spectral powers correlated with each other. The frequency- and time-domain analysis techniques of stationary short-term HRV recordings revealed significant differences in cardiovascular regulation between untreated patients with Parkinson's disease and the controls. This confirms cardiovascular regulation failure before treatment in the early stages of Parkinson's disease. The HRV spectral powers, in absolute units, were the most effective single parameters in segregating the two groups, emphasising the role of spectral analysis in the evaluation of HRV in Parkinson's disease.

Adult↗

New estimation method for fatty acid composition in oil using near infrared spectroscopy.

The absorption bands of cis-unsaturation and the carbon chain length of the fatty acid moieties in oil appear in the near infrared (NIR) wavelength region, especially around 1600-1800 nm. Using this region, a new estimation method for fatty acid composition analysis is proposed. Because the differences of the original NIR spectra are miniscule even in this region, the second derivative NIR spectra were examined in order to estimate the fatty acid composition in oil exclusively from the spectral patterns obtained. The parameters for calculating the second derivative NIR spectra were examined to make the spectral difference clearer. In any parameter, the absorption band was shifted to the shorter wavelength region when the unsaturation in fatty acid moieties increased, and it was shifted to the longer wavelength region when the carbon chain length increased. When the parameters were correct, this NIR method can estimate the fatty acid composition roughly, but simply, easily, and sometimes nondestructively.

Brassica rapa↗

An experimental study of the open end correction coefficient for side branches within an acoustic tube.

The open end correction coefficient (OECC) of acoustic tubes has been widely investigated under a free-field condition. This study examines OECCs in confined regions, such as side branches within the vocal tract. To do this, a number of mechanical acoustic models are used to examine the effects of the angle of the branch axis and the proximity of the walls of the main tract to the open end of the branch. The OECC is estimated by matching both the peaks and troughs (i.e., spectral maxima and minima) of the computed and measured transfer functions for each model. The results indicate that the OECC of a side branch depends on L/D, where L is the cross dimension of the main tract at the branching point, and D is the branch diameter. For side branches connected to the main tract through a narrow neck, the OECC of each end of the neck is determined using the ratio of the radius of the neck to that of the adjacent section. Two empirical equations for evaluating the OECC within a tract are derived from the present study. Finally, the range of appropriate OECC values for estimating an accurate vocal tract transfer function is discussed, based on the results presented here and morphologic measurements reported previously.

Ear↗

Experimental correspondence between spore dosimetry and spectral photometry of solar ultraviolet radiation.

The biologically effective dose of solar UV radiation was estimated from the inactivation of UV-sensitive Bacillus subtilis spores. Two types of independent measurements were carried out concurrently at the Aerological Observatory in Tsukuba: one was the direct measurement of colony-forming survival that provided the inactivation dose per minute (ID/min) and the other was the measurement of the spectral irradiance by a Brewer spectrophotometer. To obtain the effective spectrum, the irradiance for each 1 nm wavelenght interval from 290 to 400 nm was multiplied with the efficiency for inactivation derived from the inactivation action spectrum of identically prepared spore samples. Integration of the effective spectrum provided the estimate for ID/min. The observed values of ID/min were closely concordant with the calculated values for the data obtained in four afternoons in 1993. The average ratio (+/- SD) between them was 1.24 (+/- 0.16) for 14 data points showing high inactivation rates (> 0.05 ID/min). Considering difficulties in the absolute dosimetry of UV radiation, the concordance was satisfactory and improved credibility of the two types of monitoring systems of biologically effective dose of solar UV radiation.

Bacillus subtilis↗

[Several reasons for atomic spectral line broadening].

Several reasons for atomic spectral line broadening in terms of theory are given, that's: natural broadening: Doppler broadening; collision broadening, respectively. Some estimated data based on these reasons are provided, which may be of significance for atomic spectral measurements, and the data are in agreement with experiments.

Models, Theoretical↗

31P NMR Bayesian spectral analysis of rat brain in vivo.

Bayesian spectrum analysis for parameter estimation is a rigorous statistical (non-Fourier-based) method. Herein the Bayesian quadrature NMR model is introduced and applied to analysis of 31P NMR time domain data from in vivo rat brain. Immunity to both the brain spectrum "baseline hump" and the phase twist is demonstrated.

Animals↗

Psychophysical estimates of visual pigment densities in red-green dichromats.

1. The spectral sensitivity of red-green dichromats was determined using heterochromatic flicker photometric matches (25-30 c/s) on the fovea. These matches are upset after a bright bleach and consequently the spectral sensitivity is altered.2. Preliminary experiments indicate that under the conditions in which these experiments were performed, the blue cone mechanism of deuteranopes and protanopes cannot follow 20 c/s flicker. If dichromats lack one of the normal pigments then the upset of these matches monitors the change in spectral sensitivity of a single mechanism.3. After a bleach which removes all the cone pigments, the spectral sensitivity recovers with the time course of pigment kinetics as measured by densitometry.4. An intense background also changes the relative spectral sensitivity of the dichromats. On real equilibrium backgrounds, the changes in spectral sensitivity follow those predicted by the pigment changes measured by densitometry. The predicted changes are obtained by modifying the Rushton equilibrium equation to take into account the density of pigment.5. The relationship of these changes to the luminance of the background is independent of the colour of the background light.6. In contradistinction the effect is dependent on the colour of the lights which were flickered. These experiments indicate that a narrowing of the spectral sensitivity curves takes place on both sides of the dichromats' lambda(max).7. The change in relative spectral sensitivity as a function of background intensity was also determined by increment threshold measurements. These changes can be expressed in terms of deviations from Weber's law (DeltaI/I = const.) if DeltaI and I represent the number of chromophores destroyed by the test and background.8. The relative spectral sensitivity of the dichromat was changed by decentering the point of pupil entry. This upset was abolished by bleaching. The size of the upset was correlated with the magnitude of the S-C I effect.9. Given the hypothesis of pigment density (self-screening), the results of expts. (3)-(8) are consistent and allow the calculation of a maximum optical density for those pigments which underlie the dichromats' long-wave mechanism. For the deuteranope a D(lambdamax) of 0.5-0.6 is calculated and for the protanope a D(lambdamax) of 0.4-0.5 is obtained.

Color Perception↗