Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Solid Phase Extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57Linked to original sources

Fully automated assay for the determination of sumatriptan in human serum using solid-phase extraction and high-performance liquid chromatography with electrochemical detection.

A method is described for a fully automated, sensitive, accurate and precise assay for the determination of sumatriptan in human serum. The assay consists of solid-phase extraction followed by reversed-phase HPLC with electrochemical detection. The extraction procedure has been fully automated on a Zymate XP robot linked on-line to the HPLC system. The assay is linear over the analytical range 1-30 ng ml-1 and selective for sumatriptan with respect to endogenous plasma components and GR49336, the major circulating metabolite. The intra-assay data demonstrate a maximum bias and precision across the calibration range of 10% and 6.6% respectively. The inter-assay data demonstrate a maximum bias and precision across the calibration range of 6.7% and 8.8%, respectively. The extraction efficiency of the assay is approximately 90% and is constant across the calibration range. The assay was used for the determination of sumatriptan in serum clinical samples and was shown to be robust in sustained use over several months. The use of a Zymate XP robot allowed complete automation of the assay, which resulted in high-quality, high-throughput analyses.

Autoanalysis↗

Novel solid-phase extraction method to separate 4-desmethyl-, 4-monomethyl-, and 4,4'-dimethylsterols in vegetable oils.

Conventional methods for sterol fractions separation by TLC have some drawbacks such as low recovery and time consuming. A new solid-phase extraction (SPE) method was developed with stepwise elution by increasing the polarity of solvents mixture: n-hexane and diethyl ether. This method was applied to separate sterol fractions of hazelnut and virgin olive oils, and our results were compared with those of TLC method. The recovery of spiked authentic sample of 4-desmethylsterols in oil was higher with the SPE method (94%) compared with the TLC method (62%). The amount of 4,4'-dimethylsterols and 4-desmethylsterols separated with SPE in both hazelnut and virgin olive oil samples were at least 75% and 35%, respectively, higher than that of TLC. Generally, both methods obtained similar results for 4-monomethylsterols of the two oils. This new SPE method to separate phytosterol fractions was less time consuming, simpler and can be used instead of preparative TLC to detect adulteration of virgin olive oil with hazelnut oil.

Chromatography, Thin Layer↗

Determination of estrogens and their conjugates in water using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry.

An analytical procedure for the determination of steroid estrogens and their conjugates was developed and applied to aqueous environmental samples. The analytes of 15 compounds were solid-phase extracted and fractionated into two fractions: one containing unconjugated (free) steroids and the other containing conjugates (sulfates and glucuronides). Identification and quantification were carried out using liquid chromatography coupled with tandem mass spectrometry. The recoveries for each compound ranged from 57 to 116% and reproducibilities represented as RSD ranged from 2.9 to 17%. Some of the sulfates and free compounds were detected in environmental samples, whereas most of the conjugates were below the detection limits.

Chromatography, Liquid↗

Rapid determination of the anti-cancer drug chlorambucil (Leukeran) and its phenyl acetic acid mustard metabolite in human serum and plasma by automated solid-phase extraction and liquid chromatography-tandem mass spectrometry.

A bioanalytical method for the determination of the anticancer drug chlorambucil (Leukeran) and its phenyl acetic acid mustard metabolite in human serum and plasma is described. Automated solid-phase extraction of the analytes is carried out with C18 sorbent packed in a 96 well format microtitre plate using a robotic sample processor. The extracts are analysed by isocratic reversed-phase liquid chromatography using pneumatically and thermally assisted electrospray ionisation (TurboIonspray) with selected reaction monitoring. The method is specific and sensitive, with a range of 4-800 ng/ml in human serum and plasma for both parent drug and metabolite (sample volume 200 microl). The method is accurate and precise with intra-assay and inter-assay precision (C.V.) of <15% and bias <15% for both analytes. The automated extraction procedure is significantly faster than manual sample pre-treatment methods, a batch of 96 samples is extracted in 50 min allowing for faster sample turnaround. The method has been used to provide pharmacokinetic support to biocomparability studies of Leukeran following single doses of oral tablet formulations.

Analysis of Variance↗

Quantitation of PGE9509924, a novel, nonfluorinated quinolone, in rat plasma using liquid chromatography electrospray-tandem mass spectrometry following solid-phase extraction sample clean-up in a 96-well format.

PGE9509924, a novel nonfluorinated quinolone, is a potent antibacterial agent with a broad spectrum of activity. A semi-automated method using 96-well format, solid-phase extraction has been developed for quantitating PGE9509924 in rat plasma. The Waters Oasis HLB extraction plate containing a polymeric packing material was found to give the best overall recoveries. All liquid transfer steps other than aliquoting the plasma are accomplished using a 96-channel pipettor. Reverse-phase HPLC with electrospray/MS/MS detection using selective reaction monitoring is used to quantitate the samples. Stable isotopically labeled PGE9509924 is used as the internal standard. The assay is linear over the range from 0.01 to 10 ug/ml. Excellent precision is obtained within a single run and between multiple runs performed on different days. CVs of <6% were observed. The combination of the semi-automated, 96-well parallel sample processing and the short runtime on the LC/MS/MS results in a high throughput assay with reduced operator interaction.

Adsorption↗

Synthesis and evaluation of a molecularly imprinted polymer for selective on-line solid-phase extraction of 4-nitrophenol from environmental water.

A molecularly imprinted polymer (MIP) able to bind 4-nitrophenol (4-NP) was prepared using noncovalent molecular imprinting methods and evaluated as a selective sorbent in molecularly imprinted solid-phase extraction (MISPE) on-line coupled to a reversed-phase HPLC. It has been shown that the conditions chosen for washing the MIP and for eluting the analyte in the MISPE process are extremely important for ensuring good selectivity and recovery. River water samples, spiked with the 11 Environmental Protection Agency phenolic compounds at microgram per liter levels, were preconcentrated on-line using this MIP, and 4-NP was selectively extracted. The humic acid interference was simultaneously reduced considerably. The MIP was also compared with a commercially available highly cross-linked polymer (LiChrolut EN) and the former yielded cleaner extracts.

Chromatography, High Pressure Liquid↗

Monolithic porous polymer for on-chip solid-phase extraction and preconcentration prepared by photoinitiated in situ polymerization within a microfluidic device.

Monolithic porous polymers have been prepared by photoinitiated polymerization within the channels of a microfluidic device and used for on-chip solid-phase extraction and preconcentration. The preparation of the monolithic material with hydrophobic and ionizable surface chemistries is easily achieved by copolymerization of butyl methacrylate with ethylene dimethacrylate, or 2-hydroxyethyl methacrylate and [2-(methacryloyloxy)ethyl]trimethylammonium chloride with ethylene dimethacrylate, respectively. The porous properties, and consequently the flow resistance, of the monolithic device are controlled by the use of a mixture of hexane and methanol as a porogenic mixture. This mixture was designed to meet the specific requirements for pore formation within macroporous monoliths useful in the microfluidic formats. The low flow resistance enables high flow rates of up to 10 microL/min, which corresponds to a linear flow velocity of 50 mm/s and far exceeds the flow velocities typical of the common analytical microchips. The function of the monolithic concentration device was first demonstrated using very dilute solutions of Coumarin 519. The performance in a more realistic application was then demonstrated with the enrichment of a hydrophobic tetrapeptide and also of green fluorescent protein for which an increase in concentration by a factor as high as 10(3) was achieved.

Biotechnology↗

Solid phase extraction of Cd, Cu, and Ni from leafy vegetables and plant leaves using amberlite XAD-2 functionalized with 2-hydroxy-acetophenone-thiosemicarbazone (HAPTSC) and determination by inductively coupled plasma atomic emission spectroscopy.

A method for solid phase extraction of trace metals, namely, Cd, Cu, and Ni, using Amberlite XAD-2 functionalized with a new chelating ligand, 2-hydroxy-acetophenone-3-thiosemicarbazone (Amberlite XAD-2-HAPTSC), has been developed. The optimum experimental conditions for the quantitative sorption of three metals, pH, effect of flow rate, concentration of eluent, sorption capacity, kinetics of sorption, and the effect of diverse ions on the sorption of analytes have been investigated. The chelating resin could be reused for more than 20 cycles of sorption-desorption without any significant change (<1.5%). The accuracy of the proposed procedure was evaluated by standard reference materials. The proposed method was applied for the determination of trace metal ions in leafy vegetable samples collected from different sources and medicinal plant leaves.

Acetophenones↗

Multi-component analysis of polar water pollutants using sequential solid-phase extraction followed by LC-ESI-MS.

A multi-component screening analysis method for polar to medium-polar water pollutants was developed. Sample clean-up and group separation are performed by sequential solid-phase extraction (SSPE) using automated SPE with C18 and polymeric sorbent materials. Analyses are performed by liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) using a single-quadrupole instrument. More than 90 priority compounds of environmental interest--comprising the most important chemical and substance classes: phenols, carboxylic acids, aromatic sulfonates, aromatic amines, pharmaceuticals, surfactants, dyes, and pesticides--have been chosen for the experiments. The compounds are divided by the SSPE procedure into 3 different polarity classes. The extraction recoveries were determined in the 3 fractions for every single substance, and were for most of the analytes in the range of 50-100%. A mixture of hexane-dichloromethane was used for the elution of nonpolar compounds like alkylphenols from C18. Methanol and acetone are well suited for the elution of more polar substances. The limits of detection (LODs) were determined for all compounds. Effluents from municipal and industrial wastewater treatment plants (WWTPs) treating waste water from textile industries; and the corresponding receiving waters (rivers and lakes) have been analysed with the developed method. Urban and industrial pollution was observed in rivers and streams in the area north of Milan, Italy. In the water samples different phenols (nitrophenols, bisphenol A, nonylphenol), alkylphenol ethoxylate surfactants, their metabolites with endocrine disrupting potential, aromatic sulfonates, linear alkylbenzenesulfonate surfactants, dyes, pesticides, pharmaceuticals, and a dichlorobenzidine compound were identified.

Automation↗

Measurement of trazodone using solid-phase extraction and wide-bore capillary gas chromatography with nitrogen-selective detection.

A method for the determination of the antidepressant drug trazodone is presented. 8-Hydroxyloxapine is used as the internal standard. A simple solid-phase extraction procedure utilizing disposable reversed-phase C18 columns is described. Samples are analyzed by gas chromatography with nitrogen-selective detection using a wide-bore capillary column with a permanently bonded, nonpolar stationary phase. The assay possesses linearity to 3.0 micrograms/mL, sensitivity to at least 0.25 microgram/mL, recovery averaging 96%, and between-run precision reflected by a CV of 5.6%. We conclude that the method reported here is ideally suited for monitoring therapeutic and toxic levels of trazodone.

Chromatography, Gas↗

SPEC disc solid-phase extraction for rapid broad-spectrum drug screening in urine.

Broad-spectrum drug screening requires that all relevant substances be isolated, detected, and identified, regardless of their structure and/or polarity. To this end, systematic solid-phase extraction (SPE) approaches for drug isolation from biological fluids are required. Because speed and cost effectiveness are key issues in analytical toxicology, we have evaluated a disc-format extraction device for this purpose and compared the latter with an existing packed-bed column-format method. The discs were SPEC.PLUS.C18AR/MP3 cartridges with 10-mL solvent reservoirs, providing hydrophobic and cation exchange interactions. Blank human urine was spiked at 2 microg/mL with a selection of acidic, neutral, and basic drugs representing a variety of relevant drug classes. Urine specimens (2 mL) were diluted with 2 mL 0.1 M phosphate buffer (pH 5.0) and then applied to the preconditioned disc. Washing was done with 1 mL water. Acidic and neutral drugs were eluted with 1 mL ethyl acetate/acetone (1:1), and basic drugs were eluted with 1 mL ammoniated ethyl acetate. The eluates were collected separately, evaporated down to about 0.1 mL, and analyzed by gas chromatography-flame-ionization detection to check cleanliness, recoveries, and reproducibilities. The discs showed good extraction properties for all drugs and were easy to handle. Recoveries were 75-100% with coefficients of variation of around 5%. The resulting eluates showed only a few matrix interferences. As compared to our standard SPE method with packed-bed columns, the disc procedure allowed reductions in elution volumes and total processing time of approximately 60-65%.

Barbiturates↗

An automated and simultaneous solid-phase extraction of delta 9-tetrahydrocannabinol and 11-nor-9-carboxy-delta 9-tetrahydrocannabinol from whole blood using the Zymark RapidTrace with confirmation and quantitation by GC-EI-MS.

A sensitive, reliable, and automated solid-phase extraction (SPE) method was developed for the simultaneous extraction, confirmation, and quantitation of delta9-tetrahydrocannabinol (THC) and 11-nor-9-carboxy-delta9-tetrahydrocannabinol (THCCOOH) from whole blood. The extraction was performed on the Zymark RapidTrace SPE Workstation with a reduced solvent volume SPE copolymer cartridge. Quantitative analysis was completed on a benchtop gas chromatograph-mass spectrometer using electron ionization mode with selected ion monitoring of three ions for each analyte. The limits of quantitation for THC and THCCOOH were 2 ng/mL and 1 ng/mL, respectively. The limits of detection for THC and THCCOOH were 1.6 ng/mL and 0.8 ng/mL, respectively. Extensive method validation is presented including extraction recoveries, within-run precision, day-to-day precision, linearity, and carryover. This procedure is used routinely in the laboratory on blood samples screened positive for cannabinoids.

Automation↗

Clinical-scale high-throughput analysis of urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine by isotope-dilution liquid chromatography-tandem mass spectrometry with on-line solid-phase extraction.

BACKGROUND: Quantification of 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodGuo) in urine or blood is used to assess and monitor oxidative stress in patients. We describe the use of on-line solid-phase extraction (SPE) and isotope-dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) for automated measurement of urinary 8-oxodGuo. METHODS: Automated purification of urine was accomplished with a switching valve and an Inertsil ODS-3 column. After the addition of 15N5-labeled 8-oxodGuo as an internal standard, urine samples were analyzed within 10 min without sample purification. This method was applied to measure urinary 8-oxodGuo in a group of healthy persons (32 regular smokers and 35 nonsmokers). Urinary cotinine was also assayed by an isotope-dilution LC-MS/MS method. RESULTS: The lower limit of detection was 5.7 ng/L on column (2.0 fmol). Inter- and intraday imprecision (CV) was < 5.0%. Mean recovery of 8-oxodGuo in urine was 99%-102%. Mean (SD) urinary concentrations of 8-oxodGuo in smokers [7.26 (3.14) microg/g creatinine] were significantly higher than those in nonsmokers [4.69 (1.70) microg/g creatinine; P < 0.005]. Urinary concentrations of 8-oxodGuo were significantly correlated with concentrations of cotinine in smokers (P < 0.05). CONCLUSIONS: This on-line SPE LC-MS/MS method is sufficiently sensitive, precise, and rapid to provide high-throughput direct analysis of urinary 8-oxodGuo without compromising quality and validation criteria. This method could be applicable for use in daily clinical practice for assessing oxidative stress in patients.

8-Hydroxy-2'-Deoxyguanosine↗

Determination of itraconazole and hydroxyitraconazole in plasma by use of liquid chromatography-tandem mass spectrometry with on-line solid-phase extraction.

In this paper a method for the simultaneous quantification of the anti-fungal drug itraconazole and its co-active metabolite hydroxyitraconazole in plasma employing liquid chromatography tandem-mass spectrometry and automated solid-phase extraction is described. The method proved rugged, enables short turn-around times and is highly specific. Since there is growing evidence for the importance of therapeutic drug monitoring of itraconazole in the prophylaxis and treatment of invasive fungal infections, the method described here is of interest for a large number of tertiary care hospital laboratories.

Antifungal Agents↗

Automated solid-phase extraction for purification of single nucleotide polymorphism genotyping products prior to matrix-assisted laser desorption/ionisation time-of-flight mass spectrometric analysis.

In this article, we describe the application of a novel micro elution solid-phase extraction method for purification of short stretches of DNA products of single nucleotide polymorphisms (SNPs) prior to MALDI mass spectrometry analysis. An important feature of our method is that the purification columns containing a copolymer of divinylbenzene and N-vinylpyrrolidone can be used several times thereby significantly reducing costs. We implemented this DNA purification technology into a fully automated procedure including molecular biology, MALDI sample preparation, automated mass spectrometric analysis and SNP allele calling by software. Due to the facile purification protocol, the methodology shown could furthermore be used for other applications where efficient medium to high-throughput purification of nucleic acids is required.

Alkaline Phosphatase↗

Determination of 4,4'-methylenebis(2-chloroaniline) in urine by liquid chromatography with ion-paired solid-phase extraction and electrochemical detection.

This highly specific and sensitive method for measuring urinary 4,4'-methylenebis(2-chloroaniline) (MBOCA) involves liquid chromatography with electrochemical detection. Before chromatography, urine samples are prepared by ion-paired solid-phase extraction on a disposable octadecylsilica column with acidic methanol solution containing 1-heptanesulfonic acid. This enhances the specificity of the method. Mean overall recovery ranged from 97.1% to 99.5% at added MBOCA concentrations of 20 and 100 micrograms/L in urine. Sensitivity for urine was 1 microgram/L. The intra-assay CV was 2.2% at a MBOCA concentration of 100 micrograms/L. We believe that this method is acceptable for routine measurement of MBOCA in urine from individuals exposed to this industrial chemical.

Benzhydryl Compounds↗

Determination of paraquat in biologic materials by a simplified solid phase extraction and spectrophotometry.

A rapid measurement of low paraquat levels in body fluids is important for diagnosis and prognosis of paraquat intoxication. A simple and sensitive method for the determination of submicrogram levels of paraquat by solid phase extraction in conjunction with spectrophotometry has been developed. Serum, urine and formalin from fixed tissue were passed through this column and paraquat was eluted with 2 mL 2N NaOH. The eluent was reduced with dithionite and spectrophotometrically quantified with the zero- or second-order derivative. The detection limits of paraquat by this method are 0.05 mg/L and 0.01 mg/L with the zero-order and 0.005 mg/L and 0.001 mg/L with the second-order derivative, using 2 mL of serum and 10 mL of urine or formalin. The proposed method prevents the interference of biologic specimens as well as providing high extraction efficiency and good precision. The entire procedure can be completed within 30 minutes without special skills, reagents or equipment. These results show that this method is suitable for clinical and forensic toxicologic purposes.

Chromatography, Gel↗

Simultaneous determination of nicotinic acid and its two metabolites in human plasma using solid-phase extraction in combination with high performance liquid chromatography.

A high performance liquid chromatographic method for the simultaneous quantitative determination of nicotinic acid, nicotinamide and nicotinuric acid in human plasma is described. The method is based on solid phase extraction in combination with ion-paired reversed phase high performance liquid chromatography. Recoveries of nicotinic acid, nicotinamide and nicotinuric acid are 92.9, 95.8 and 87.8%, respectively. The procedure shown was applied to the determination of the plasma time-concentration profile of nicotinic acid, nicotinamide and nictotinuric acid after nicotinic acid ingestion in humans.

Adult↗