Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SCINTILLATION COUNTER”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57Linked to original sources

Limited extracellular but complete intracellular acid-base regulation during short-term environmental hypercapnia in the armoured catfish, Liposarcus pardalis.

Environmental hypercapnia induces a respiratory acidosis that is usually compensated within 24-96 h in freshwater fish. Water ionic composition has a large influence on both the rate and degree of pH recovery during hypercapnia. Waters of the Amazon are characteristically dilute in ions, which may have consequences for acid-base regulation during environmental hypercapnia in endemic fishes. The armoured catfish Liposarcus pardalis, from the Amazon, was exposed to a water P(CO(2)) of 7, 14 or 42 mmHg in soft water (in micromol l(-1): Na(+), 15, Cl(-), 16, K(+), 9, Ca(2+), 9, Mg(2+), 2). Blood pH fell within 2 h from a normocapnic value of 7.90+/-0.03 to 7.56+/-0.04, 7.34+/-0.05 and 6.99+/-0.02, respectively. Only minor extracellular pH (pH(e)) recovery was observed in the subsequent 24-96 h. Despite the pronounced extracellular acidosis, intracellular pH (pH(i)) of the heart, liver and white muscle was tightly regulated within 6 h (the earliest time at which these parameters were measured) via a rapid accumulation of intracellular HCO(3)(-). While most fish regulate pH(i) during exposure to environmental hypercapnia, the time course for this is usually similar to that for pH(e) regulation. The degree of extracellular acidosis tolerated by L. pardalis, and the ability to regulate pH(i) in the face of an extracellular acidosis, are the greatest reported to date in a teleost fish. The preferential regulation of pH(i) in the face of a largely uncompensated extracellular acidosis in L. pardalis is rare among vertebrates, and it is not known whether this is associated with the ability to air-breathe and tolerate aerial exposure, or living in water dilute in counter ions, or with other environmental or evolutionary selective pressures. The ubiquity of this strategy among Amazonian fishes and the mechanisms employed by L. pardalis are clearly worthy of further study.

Acid-Base Equilibrium↗

Distribution of radiolabeled monoclonal antibody MX35 F(ab')2 in tissue samples by storage phosphor screen image analysis: evaluation of antibody localization to micrometastatic disease in epithelial ovarian cancer.

Our objective was to quantify the targeting of the monoclonal antibody (mAb) MX35 F(ab')2 to micrometastatic epithelial ovarian cancer. This mAb detects a Mr 95,000 glycoprotein with homogeneous distribution on 80% of ovarian tumor specimens. Six patients with minimal residual disease from an imaging trial were injected with 2 or 10 mg of 131I- and 125I-labeled mAb MX35 F(ab')2. Biopsied samples were removed at second-look laparotomy 1-5 days post-i.v. or -i.p. infusion of antibody. Serial cryostat sections were stained by indirect immunoperoxidase method for antigen distribution and exposed to storage phosphor screens for quantitative autoradiography. Coregistration of tumor histology, antigen expression, and radionuclide distribution demonstrated specific localization in micrometastatic tumor foci (50 micrometer to 1 mm) found within tissue stroma. The radiolabeled antibody uptake determined by well scintillation counts ranged between 5.2 and 223.5 x 10(-4) percentage of injected dose/g of tumor tissue for 131I. Specific localization of mAb in tumor was determined by tumor:normal tissue (fat) ratios ranging from 0.9:1 to 35.9:1 for 131I. The high resolution and linear response of the storage phosphor screen imager was used to estimate the radionuclide activity localized in each micrometastatic site. Quantitation of phosphor screen response revealed microCi/g values of 0.026-0.341 for normal tissue and 0.184-6.092 for tumor biopsies, evaluated 4 or 5 days post-antibody injection. The tumor:normal tissue (adjacent to tumor) ratios were between 1 and 4 times greater using the phosphor screen method than well counter measurements, but even larger variations of ratios up to 20:1 were observed between tumor cell foci and stromal cells within the same tissue section. This study has demonstrated that mAb MX35 F(ab')2 localizes to the micrometastatic ovarian carcinoma deposits within the peritoneal cavity. The dosimetry results suggest a therapeutic potential for this antibody in patients with minimal residual disease (<5 mm).

Antibodies, Monoclonal↗

[Reliability and limitations of total and divided renal clearances as determined with a partially shielded whole-body counter (author's transl)].

Error and reproducibility of the total and divided renal clearance determination was investigated, using a partially shielded whole-body counter. The error of the total renal clearance determination using ortho-131I-hippuran (OIH) depends primarily on the downslope of the whole-body curve, i.e. on renal function. The error is as low as +/- 6% for clearance values of more than 100 ml/min and increases slowly with clearance values decreasing about 35 ml/min. The error of clearance values below 25 ml/min is higher than 50%. The error of the divided renal clearance using OIH is the same as the error of the total renal clearance. The reproducibility of the total OIH-clearance in single clearance periods was found to be +/- 6% and in repeated determinations +/- 12% (r = 0.97). The reproducibility of the divided renal OIH-clearance with scintillation probes showed an average deviation from the mean of +/- 10% (r = 0.87). The substitution of the scintillation probes by a scintillation camera and the use of regions of interest should diminish this error considerably. The results were compared with literature data on standard PAH- and inulin clearances.

Humans↗

Measurement for the dose-rates of the cosmic-ray components on the ground.

In this study, we aimed to measure the directly ionizing component (muons and photons) and the indirectly ionizing component (neutrons) of the cosmic-ray spectra and evaluate their dose rate contribution to the total dose rate on a ground level in Japan. Measurements were carried out in Tohoku University, Japan, from October 2000. The pulse-height spectra of the cosmic-ray photons and muons were measured with a 12.7 cm diameter and 12.7 cm long NaI(Tl) scintillation detector. In order to measure energy spectra of cosmic-ray photons and muons, response functions of the detector to photons and muons were determined by the Monte Carlo simulation codes. The cosmic-ray photon dose was evaluated directly from the measured pulse-height spectrum by using the spectrum weight function, and the cosmic-ray muon dose was evaluated by converting the measured pulse height spectrum into deposited energy within the detector. The quantity of the cosmic-ray electrons is estimated to be very small and is not taken into account in this study. The cosmic-ray neutron spectrum and the neutron dose were measured by using a multi-moderator spectrometer (Bonner ball) and a rem counter. The measurements could finally give the annual absorbed dose in tissue of the cosmic-ray muons of 315 microSv/y and annual ambient doses of the cosmic-ray photons and neutrons on the ground in Japan of 55 microSv/y and 31 microSv/y, respectively.

Background Radiation↗

First microdosimetric measurements with a TEPC based on a GEM.

A new type of mini multi-element tissue-equivalent proportional counter (TEPC) based on a gas electron multiplier (GEM) has been designed and constructed. This counter is in particular suitable to be constructed with a small sensitive volume so that it can be used for microdosimetry in intense pulsed radiation fields to measure the microdosimetric spectrum in the beam of, for instance, a clinical linear accelerator. The concept lends itself also for a mini multi-element version of the counter to be used for applications in which a high sensitivity is required. In this paper, we present the first microdosimetric measurements of this novel counter exposed to a 14 MeV monoenergetic neutron beam and a californium (252Cf) source for a counter cavity diameter of 1.8 mm simulating 1.0 microm tissue site size. The measured spectra showed an excellent agreement with spectra from the literature. The specific advantages of the TEPC-GEM are discussed.

Algorithms↗

Nanodosimetric measurements with an avalanche confinement TEPC.

This paper illustrates a tissue-equivalent proportional counter designed to have high gas gain and good energy resolution at nanometric simulated site sizes. Microdosimetric neutron and gamma spectra were measured in dimethyl ether and in propane-based tissue-equivalent gas mixture down to 35 nm. The comparison of experimental data with the results of Monte Carlo calculations shows a satisfactory agreement.

Dose-Response Relationship, Radiation↗

Microprocessor crosstalk correction in multiple-detector gamma counters.

A method for compensating for crosstalk between nuclear counters and its application to a multidetector gamma counter is described. The standardisation procedure employed measures the relative efficiency of each detector for a sample within that detector and for the same detector when the sample is located in each of the other detectors. Results with a 12-element detector system show that the stored calibration data obtained in this way can be applied successfully to correct the observed count rates for crosstalk as well as detector sensitivity differences when using gamma emitters having energies up to 1.3 MeV.

Computers↗

The use of a high-purity germanium detector for routine measurements of 125I in radiation workers.

A high-purity germanium detector was calibrated for the assessment of 125I uptake in the thyroid gland of radiation workers. A cylindrical water phantom (perspex walls) with high flexibility for position and size of the thyroid was constructed. Within a massive shielding chamber built for a whole-body counter, an activity of 2.2 Bq was detectable (MDA). This is well below the very restrictive limiting value of 20 Bq for inhalation specified by Austrian law. An activity of 128 Bq was measured with a statistical uncertainty of 5% in a counting period of 10 min. Various parameters influencing the result are investigated as well as the performance of two other measurement geometries outside the shielding chamber.

Gamma Rays↗

Estimation of pulmonary deposition of aerosol using gamma scintigraphy.

Following delivery of technetium 99m-labeled aerosols through a ventilator circuit, the amount of radioactivity in the lungs of 58 ventilated rabbits was estimated first by gamma scintigraphy via gamma camera and later by direct counting of the excised lungs (n = 116 specimens) with a gamma counter. The in situ radioactivity measured via scintigraphy was closely correlated with the gamma counter ex vivo tissue counts of the radioactivity (R2 = 0.997, P < 0.001). Overall, gamma scintigraphy gave slightly lower values of activity than the tissue counts from the gamma counter, but the limits of agreement between the two measurements were narrow enough for us to consider that the tissue and scintigraphy methods were in agreement. We conclude that gamma scintigraphy provides a convenient and noninvasive means for the accurate estimation of aerosol deposition in the lungs of small animals and possibly in small infants.

Aerosols↗

Time characteristics of a multi-wire 4 pi beta-counter.

In order to examine the time characteristics of a multi-wire 4 pi beta-counter for the 4 pi beta-gamma coincidence system, measurement was made on the time distributions of the pulses from the individual anodes. The time distribution obtained by each anode was explained mainly by the distribution of primary ionizing position. A similar time distribution was obtained in the case that the alternating wires cathodes, when the individual anodes had the same effective detection region. Spurious pulses were observed in 90% argon plus 10% methane mixture at the end voltage of the plateau region and not methane gas.

Electrons↗

[The use of radiodiagnostic apparatus as human radiation counters in large-scale radiation accidents].

The problem of dosimetry of internal irradiation necessitates the use of human radiation counters (HRC). A state system of radiation safety should be based on a HRC stock in case of large-scale radiation accidents. Radiodiagnostic units can run in the HRC mode therefore they must be considered as an active reserve widely spread throughout the country. Radiodiagnostic devices can be used for control of the thyroid level of 131I and the whole-body content of a mixture of 134Cs and 137Cs.

Accidents↗

Action of aldosterone on protein expression in cultured collecting duct cells from neonatal rabbit kidney.

To investigate whether 'aldosterone-induced proteins' could be detected in mammalian species, cultured renal collecting duct epithelia from neonatal rabbit kidneys were labelled under aldosterone administration with radioactive methionine and subsequently fractionated into cytosolic and coarse membrane protein fractions. Newly synthesized proteins were then analyzed by SDS-PAGE, isoelectric focussing and two-dimensional electrophoresis. Quantitative estimates of individual newly synthesized proteins were performed utilizing gel slicing, scintillation counting and autoradiography. The labelling experiments demonstrated that, in comparison to controls, aldosterone (1 X 10(-6) M) generally increased the amount of radioactive protein. No qualitative changes in the pattern of newly synthesized proteins and, therefore, no classical aldosterone-induced proteins were observed. The increase of radioactive protein was already seen after 1, 6, and 18 h of hormone treatment. The effect could be blocked partially by spironolactone (1.5 X 10(-4) M), and totally by amiloride (1 X 10(-6) M), g-strophantin (5 X 10(-4) M), and cycloheximide (1 X 10(-6) M. Thus, the interference of aldosterone action at the receptor level, the Na+ channels and the Na+/K(+)-ATPase pump demonstrate that the expression of proteins in cultured renal collecting duct cells is a sensitive system and seems to be controlled by aldosterone at the receptor level, but also counter-controlled by specific plasma membrane sites.

Aldosterone↗

Enhanced localization of osteoid osteoma with radiolabeling and intraoperative gamma counter guidance: a case report.

Osteoid osteoma is a benign bone tumor that can be removed by marginal excision. Excessive removal of reactive bone may result in significant morbidity. We made use of the highly specific radioactive technetium uptake characteristic of osteoid osteoma for its localization. Radioactive technetium (25 mCi) was injected intravenously 2 hours before surgery to a 21-year-old male patient with an osteoid osteoma over the left distal radius. Tumor tissue was localized intraoperatively by a portable hand-held radioactive gamma counter to detect a focal high intensity of radioactivity. Complete tumor removal was shown by reduction of radioactivity to background level. This was confirmed by bone scintigraphy of the specimen and the forearm immediately after surgery. The defect was packed with cancellous bone graft taken from the ipsilateral distal radius through the same wound. Postoperative recovery was very satisfactory. We found this approach useful in limiting resection margin and surgical site morbidity in resection of osteoid osteoma.

Adult↗

Estimation of degradation rate of acetylcholine receptor by external gamma counting in vivo.

We describe a novel method for estimating the rate of destruction of the acetylcholine receptor (AChR) associated with the motor end-plate in the living animal. After the intramuscular injection of a nontoxic dose of alpha-bungarotoxin that had been monoiodinated with 125I (125I-BGT), the loss of radioactivity from the injected site is monitored by an externally positioned gamma counter. Two days after labeling, the decline of radioactivity in the injected muscle parallels the decline of end-plate specific radioactivity and can be used for the estimation of the degradation rate and half-life of end-plate AChR. Using this method, we measured AChR half-life in normal and in myasthenic rats and found a 2.5-fold decrease of AChR half-life in the myasthenic animals. This in vivo method has potential clinical applications.

Animals↗

Measurement of the neutron fluence and dose spectra using an extended bonner sphere and a tissue-equivalent proportional counter.

A conventional Bonner Sphere (BS) set consisting of six polyethylene spheres was modified to enhance its response to a high-energy neutron by putting a lead shell inside a polyethylene moderator. The response matrix of an extended BS was calculated using the MCNPX code and calibrated using a 252Cf neutron source. In order to survey the unknown photon and neutron mixed field, a spherical tissue equivalent proportional counter (TEPC) was constructed and assembled as a portable measurement system. The extended BS and the self-constructed TEPC were employed to determine the dosimetric quantities of the neutron field produced from the thick lead target bombarded by the 2.5 GeV electron beam of Pohang Accelerator Laboratory (PAL) and the neutron calibration field of Korea Atomic Energy Research Institute (KAERI).

Body Burden↗

Apparent high tritium intake by a radiation worker at the University of Rochester.

On 20 September 1999, a urine sample submitted by a University of Rochester radiation worker was noted to have a count rate of about 759,500 disintegrations per minute (dpm) per milliliter as analyzed on the Radiation Safety Unit (RSU) Packard liquid sintillation counter. The sample was recounted that day with variable results but each time indicating several hundred thousand dpm of activity present. Calculations indicated this corresponded to a whole-body uptake of about 518 MBq (14 nmCi) and a whole-body dose of about 10 msv (1 rem). An investigation indicated it was unlikely for these analytical results to indicate an actual uptake of tritium and suggested the results were most likely due to chemical luminescence in the sample. Accordingly, no dose was assigned to this worker from the exposure.

Artifacts↗

Use of a solid-state multihead gamma counter in a second-generation system for solid-phase immunoassay.

Simultaneous advances in detector technology and solid-phase separation systems, as well as the availability of powerful desktop computers, have made possible the development of "second-generation" solid-phase immunoassays. These retain the advantages of classical solid phase while significantly accelerating reaction kinetics. Hapten assays--such as for digoxin, thyroxin, and triiodothyronine uptake--in batches of 48 are processed in about 20 min from reagent introduction until hard-copy printout, with minimal operator involvement. The system also functions as a 48-detector gamma counter, capable of counting and reducing data for any 125I-based RIA that can be run in a 12 X 75 mm test tube. System control, data management, and computer screen displays of kinetic data are provided by an unmodified Hewlett Packard HP-87XM computer. User-friendly disc-based software facilitates the creation and storage of counting and data reduction protocols for as many as 30 RIAs from various manufacturers as well as up to 30 of our own assays.

Computers↗

Design of a 10 nm electron collector for a track-nanodosimetric counter.

Recently we have developed a track-nanodosimetric counter, which is a gas detector that measures the distributions of electrons induced by a charged particle in nanometric volumes of tissue equivalent matter, positioned at different distances from the track. Sites equivalent to 20 and 24 nm were defined by means of an electron collector, which is a system of electrodes enclosing an almost wall-less cylindrical volume. In this paper, we present the design of a new electron collector that is able to simulate a volume as small as 10 nm in diameter.

Algorithms↗