Real-time sensing of tooth position for dental digital subtraction radiography.

Dental digital subtraction radiography requires accurate repositioning of the patient and X-ray source in order to facilitate correct diagnostic of bone loss. Present mechanical repositioning systems do not allow radiography of posterior teeth, and are uncomfortable for the patient. A new repositioning system that utilizes a six degrees of freedom position sensor and a robot arm with X-ray source is proposed. A mathematical model for the system is given, and the robot arm solution is obtained based on patient position. An error analysis is performed in order to determine the influence of sensor and robot errors on system accuracy. A series of experiments to determine sensor noise and accuracy are described. These tests showed relatively small errors over the work envelope of the sensor. Further tests showed that there is no adverse effect due to the presence of metal work in the patient's mouth. The high bandwidth of the sensor may allow real time tracking of small movements of the patient's head.

Alveolar Bone Loss↗

Pixelwise fusion for optimizing SNR in multiple-plate computed radiography imaging.

The computed radiography (CR) technique, also known as the storage phosphor imaging technique, has evolved to be a major candidate for large-scale implementation of digital radiography during the past decade. In order to obtain a reasonable spatial resolution, the storage phosphor plate used is generally limited in thickness. This leads to X rays being only partially absorbed by the detector. Useful information may be contained in the X rays transmitted through the detector. Multiple-plate imaging techniques may be used to capture and utilize the X rays more efficiently. In this paper, an image fusion method, based on the Rayleigh principle and the Karhunen-Loeve (K-L) transform, is presented for optimizing the signal-to-noise ratio (SNR) of the fused image on a pixel-by-pixel basis. Because the multiple-plate images contain the same structural information, the signal components of the images are highly correlated with one another. Thus, the K-L transform is applied to decompose each of the multiple-plate images into an eigen image (the estimated signal) and a residual image (the estimated noise). An average representation entropy measure is maximized for selecting the number of eigen components to be included in the signal estimation. An experimental study, using an anthropomorphic chest phantom, is presented to illustrate pixelwise fusion of multiple-plate images. Experimental results show that the SNR of the fused image was improved by 12-48%, depending upon the anatomical regions of interest in the image.

Computer Simulation↗

Pulmonary function, extravascular lung water and chest radiography in a porcine model of adult respiratory distress syndrome.

To study the pathophysiology and the value of chest radiography in the diagnosis of early adult respiratory distress syndrome spontaneously air-breathing pigs under ketamine anaesthesia were investigated. Five control animals received physiological saline and showed no notable changes in physiological or radiological data. Eleven animals were infused i.v. with E. coli endotoxin over 6 h. The pulmonary dysfunction in the endotoxin animals was characterized by an early increase in venous admixture with hypoxaemia and a peak increase in pulmonary vascular resistance at 0.5 h after start of endotoxin infusion. Subsequently there was a tendency towards a restitution to baseline physiology, but from 3 h onwards a "second wave" of pulmonary dysfunction developed in addition to an increase in extravascular lung water. No significant correlation (r = 0.44) existed between the increase in extravascular lung water and venous admixture. The increase in calculated pulmonary microvascular pressure correlated significantly (r = 0.77) with the increase in extravascular lung water. Radiographic signs of pulmonary oedema were sparse. Thus, only three of 11 animals displayed increased density on chest radiography indicative of pulmonary oedema.

Animals↗

Assessment of microheterogeneity of blood flow in the rat urinary bladder by high-resolution digital radiography.

OBJECTIVES: To assess high-resolution digital radiography for measuring blood flow and thus examine the microheterogeneity of bladder microcirculation in a rat model. MATERIALS AND METHODS: Microheterogeneity of blood flow in both mucosa and detrusor muscle of eight anaesthetized rats was investigated using an imaging technique with very high spatial resolution (0.1 x 0.1 mm(2)) using digital radiography combined with the deposition of (3)H-labelled desmethylimipramine. The spatial pattern of blood flow was quantified by the coefficient of variation of the regional flow (CV = sd/mean). RESULTS Muscle blood flow was less than mucous blood flow (muscle : mucosa, 2.9 : 5) in the empty bladder. In the muscle layer the blood flow distribution was more heterogeneous than that in the mucosa, with a mean (sd) CV in muscle and mucosa of 0.33 (0.033) and 0.16 (0.019), respectively (P < 0.001) at the capillary level. CONCLUSION: There was a heterogeneous distribution of blood flow in the microcirculation to capillary vessels in the muscular layer, possibly reflecting a difference in dynamic blood flow of regional perfusion of the emptied bladder.

Animals↗

Role of antenatal radiography in the management of breech deliveries.

a retrospective study was made of 228 mature singleton breech deliveries occurring over a 2 year period to determine the role of antenatal radiography, in particular, of pelvimetry. Many (65%) had abdominal radiography. Where antenatal pelvimetry was performed (38%) the infants were in significantly better condition during the neonatal period; this was most marked with parous women. There was no significant difference in the neonatal condition of 25 infants born vaginally of women with favourable pelvimetry compared with 31 infants born by elective caesarean sections.

Adult↗

Does digital chest radiography assess regional ventilation?

Digital radiography of the chest was evaluated for estimation of regional ventilation disturbances. Thirty-three patients with suspected bronchial carcinomas were examined. Objective measurements of regional density changes during breathing correlated significantly with standardized regional lung function tests (133Xe ventilation scintigraphy), but did not permit reliable individual estimations of regional ventilation. About 35% of the density variations could be explained by regional ventilation. Thus, factors other than ventilation, e.g. changes in the geometry of the thorax, have a major impact on the density variation at digital radiography.

Adult↗

Value of routine chest radiography in the medical screening of internationally adopted children.

AIM: To assess the value of the routine chest radiography as part of the medical evaluation of newly arrived, internationally adopted children. METHODS: We evaluated the use of routine chest radiography (CXR) in the medical screening of 1598 internationally adopted children. RESULTS: CXR showed abnormalities in 128 cases: 38 of these findings were already known and/or consistent with obvious clinical signs or symptoms, and 54 had no clinical relevance. In two patients, CXR raised the suspicion of tuberculosis. CONCLUSION: The routine use of CXR in the screening of internationally adopted children rarely yields new, clinically relevant, information and should be performed on indication only.

Adoption↗

Ultrasonography versus radiography for detection of fluid in the canine tympanic bulla.

The tympanic bullae of 20 previously healthy cadaver animals were randomly filled with sterile saline or air. The heads were positioned using tape ties and a rostrocaudal open mouth radiograph taken. The resulting radiographs were assessed by a blinded ECVDI diplomate, with each tympanic bulla being recorded as being either air or fluid filled. Ultrasound examination of the bullae was performed, by a blinded assessor, using a B-mode 5 mHz sector probe (Sonotron-VingMed Sound A/S, PO Box 141, N3191, Horten, Norway) operating at 3 mHz. Each bulla was recorded as being either air or fluid filled. Results of radiography and ultrasonography were each compared to the actual status of the bulla in a chi square analysis. Sensitivity of radiography was 80%, with specificity of 65%. Ultrasonographic sensitivity was 100% and specificity 100%. Ultrasonography may in future provide a cheap, noninvasive, rapid and widely available method for diagnosing otitis media in clinical cases.

Animals↗

Radiological protection in equine radiography and radiotherapy.

The principles of radiological protection are summarised and consideration is then given to problems, which may confront the equine practitioner, in the fulfillment of these principles during diagnostic radiography of the limbs, head, and spine of the horse. The place of anaesthesia in such procedures is discussed and the special problems associated with therapeutic radiography of the horse are considered.

Anesthesia↗

Problems associated with the use of radiography in the examination of a horse for a purchaser.

The radiography of horses on behalf of a purchaser has become an inevitable part of a veterinarian's work. Radiography should, in theory, pose no more problems than a general clinical examination. In practice, difficulties arise when insufficient or inadequate films are taken or the films are misinterpreted. Radiographs of a diagnostic quality need to be taken and interpreted by a veterinarian who is reasonably well versed in radiological interpretation. Occasionally a lesion will be overlooked or misinterpreted and the radiographs will be retained so that the veterinarian's judgement can be challenged. Nevertheless, if the examination is properly conducted it is the prospective purchaser who must accept the inherent limitations of the technique, not the examining veterinarian. There is an urgent need for discussions to clarify and agree on the scope of the radiographic examination which should be performed. There is also a need for further research into the significance of minor radiographic variations from normality in equine limbs and into the natural history of the diseases which affect this most vital area.

Animals↗

Use of contrast radiography in the investigation of tenosynovitis and bursitis in horses.

Contrast radiography, using a 25 per cent solution of sodium diatrizoate, has been used for the investigation of tenosynovitis and bursitis in horses. The procedure was undertaken on a series of 32 clinical cases and on specimens obtained at autopsy. Lesions affecting the extensor tendon sheaths at the carpus, the digital sheath, the tarsal sheath and the bursae at the elbow, hock and fetlock were examined by this means. The results showed the procedure offered the clinician useful information about the nature of the interior of these structures, particularly as regards the presence of adhesions and anastomoses between adjacent sheaths and joint capsules. Together with other clinical and laboratory findings, contrast radiography can assist in assessing the prognosis and in formulating appropriate treatment.

Animals↗

Schemes for the optimization of chest radiography using a computer model of the patient and x-ray imaging system.

A computer program has been developed to model chest radiography. It incorporates a voxel phantom of an adult and includes antiscatter grid, radiographic screen, and film. Image quality is quantified by calculating the contrast (deltaOD) and the ideal observer signal-to-noise ratio (SNR(I)) for a number of relevant anatomical details at various positions in the anatomy. Detector noise and system unsharpness are modeled and their influence on image quality is considered. A measure of useful dynamic range is computed and defined as the fraction of the image that is reproduced at an optical density such that the film gradient exceeds a preset value. The effective dose is used as a measure of the radiation risk for the patient. A novel approach to patient dose and image quality optimization has been developed and implemented. It is based on a reference system acknowledged to yield acceptable image quality in a clinical trial. Two optimizations schemes have been studied, the first including the contrast of vessels as measure of image quality and the second scheme using also the signal-to-noise ratio of calcifications. Both schemes make use of our measure of useful dynamic range as a key quantity. A large variety of imaging conditions was simulated by varying the tube voltage, antiscatter device, screen-film system, and maximum optical density in the computed image. It was found that the optical density is crucial in screen-film chest radiography. Significant dose savings (30%-50%) can be accomplished without sacrificing image quality by using low-atomic-number grids with a low grid ratio or an air gap and more sensitive screen-film system. Dose-efficient configurations proposed by the model agree well with the example of good radiographic technique suggested by the European Commission.

Dose-Response Relationship, Radiation↗

A-Si:H/CsI(Tl) flat-panel versus computed radiography for chest imaging applications: image quality metrics measurement.

Amorphous silicon (a-Si:H) flat-panel (FP) imaging systems have recently become commercially available for both chest and mammographic imaging applications. It has been shown that this new detector technology offers better image quality and various operational advantages over the computed radiography (CR) which to date has been the most widely implemented and used digital radiography technique. However, most image quality measurements reported on flat-panel systems have been performed on prototype systems in laboratories while those for CR systems were typically independently performed and reported on in separate studies. To directly compare the two technologies, we have measured the image properties for a commercial amorphous silicon/cesium iodide [a-Si:H/CsI(Tl)] flat-panel based digital chest system and a commercial CR system under clinical imaging conditions. In this paper, measurements of image quality metrics, including the modulation transfer functions (MTFs), noise power spectra (NPSs), and detective quantum efficiencies (DQEs), for the FP and CR systems are presented and compared. Methods and issues related to these measurements are discussed. The results show that the flat-panel system has slightly lower MTF but significantly higher DQEs than the CR system. The DQEs of the flat-panel system were found to increase with the exposure while those of the CR system decrease slightly with the exposure.

Humans↗

First proton radiography of an animal patient.

The purpose of this work is to show the feasibility of proton radiography in terms of radiation dose, imaging speed, image quality (density and spatial resolution), and image content under clinical conditions. Protons with 214 MeV energy can penetrate through most patients and were used for imaging. The measured residual range (or energy) of the protons behind the patient was subtracted from the range without an object in the beam path and used to create a projected image. The image content is therefore proportional to the range that protons have lost in the patient. We took proton images of the head of a dog after it received proton radiotherapy treatment of a nasal tumor. The spatial resolution by measuring for each proton separately its coordinate in front of and behind the patient was approximately 1 mm. The acquisition time was on the order of several seconds and was limited by the patient table movement. The range sensitivity of the images was approximately 0.6 mm, which is good enough to use the images for therapy range verification. The dose that the dog received during exposure was 0.03 mGy, which is approximately a factor 50-100 smaller than for a comparable x-ray image. The potential to obtain quantitative images of proton ranges with satisfying spatial and range resolution and low dose to the patient suggests that proton radiography should be applied to patients who are under proton radiotherapy treatment.

Animals↗

Temporal subtraction in chest radiography: automated assessment of registration accuracy.

Radiologists routinely compare multiple chest radiographs acquired from the same patient over time to more completely understand changes in anatomy and pathology. While such comparisons are achieved conventionally through a side-by-side display of images, image registration techniques have been developed to combine information from two separate radiographic images through construction of a "temporal subtraction image." Although temporal subtraction images provide a powerful mechanism for the enhanced visualization of subtle change, errors in the clinical evaluation of these images may arise from misregistration artifacts that can mimic or obscure pathologic change. We have developed a computerized method for the automated assessment of registration accuracy as demonstrated in temporal subtraction images created from radiographic chest image pairs. The registration accuracy of 150 temporal subtraction images constructed from the computed radiography images of 72 patients was rated manually using a five-point scale ranging from "5-excellent" to "1-poor;" ratings of 3, 4, or 5 reflected clinically acceptable subtraction images, and ratings of 1 or 2 reflected clinically unacceptable images. Gray-level histogram-based features and texture measures are computed at multiple spatial scales within a "lung mask" region that encompasses both lungs in the temporal subtraction images. A subset of these features is merged through a linear discriminant classifier. With a leave-one-out-by-patient training/testing paradigm, the automated method attained an A(z) value of 0.92 in distinguishing between temporal subtraction images that demonstrated clinically acceptable and clinically unacceptable registration accuracy. A second linear discriminant classifier yielded an A(z) value of 0.82 based on a feature subset selected from an independent database of digitized film images. These methods are expected to advance the clinical utility of temporal subtraction images for chest radiography.

Algorithms↗

Establishment of a beam line at the Fermi National Accelerator Laboratory for proton radiography.

A proton beam is extracted from the 200-MeV linear accelerator at the Fermi National Accelerator Laboratory to investigate the efficacy of proton radiography in medical diagnosis. Fluence rates from 2 X 10(3) to 2 X 10(5) protons/cm2s over a 28-cm diameter field are obtained with a full width at half-maximum beam-energy spread of less than 3.61 MeV. The system is designed to radiography most parts of the human body, including the head, with high-speed screen-film as the imaging medium. Beam extraction and test results along with the medical implications of the beam quality are reported.

Laboratories↗

Scattered radiation in chest radiography.

Luminance scatter fractions were measured for patients and phantoms in various regions of the chest film. Scatter fractions were found to be highly variable, being quite high in the regions of the chest with a large equivalent tissue thickness (e.g. mediastinum, chest wall, and subdiaphragmatic areas). For example, approximately 90% of the radiation reaching the mediastinum region of the chest film was found to be scattered radiation when a grid was not used. Even with a 12:1 grid, less than 50% of the available primary beam contrast was being displayed in the mediastinum. In regions of the chest film with high scatter fractions, film latitude was also a problem, further reducing image contrast in these regions. Image contrast and scatter fractions in chest radiography were investigated for different scatter rejection techniques including air gaps, antiscatter grids, and slit radiography.

Humans↗

A xenon ionization detector for scanned projection radiography: theoretical considerations.

Xenon ionization detectors have been used successfully in computed tomography (CT) scanners; however, the detector design used in CT scanners does not provide sufficient spatial resolution for scanned projection radiography. We have been investigating a new design of xenon detector with individual element widths of 0.5 mm. In this design, there are no metal septa separating individual elements. As a result, detection efficiency is better than the design with septa, and construction of an array with submillimeter element widths is simpler; however, crosstalk will now occur between elements. Theoretical calculations of efficiency and resolution for our septaless design of xenon detector are presented. Results of these calculations indicate that for a spectrum of 100 kVp, element dimensions of 0.5 mm X 0.5 mm X 10 cm, a front window of 0.5-mm aluminum, and a xenon pressure of 20 atm, quantum efficiency will be greater than 95%, detective quantum efficiency (DQE) will be approximately 75%, and both energy and conversion efficiencies will be limited to 50% by K-fluorescent escape. The calculations also predict that for the same design, the reduction in lesion contrast induced by crosstalk will be less than 10% for all typical spectra. These theoretical results have encouraged us to pursue the construction of a prototype septaless xenon detector for scanned projection radiography.

Models, Theoretical↗