Experimental analysis of T1 imaging with a single-scan, multiple-point, inversion-recovery technique.

Look and Locker's single-scan, multiple-point, T1 determination technique modified for imaging applications was evaluated experimentally for its accuracy and reliability with respect to the pulse sequence parameters, in particular, to the interpulse delay, tD, and the tip angle, alpha. T1 imaging experiments were performed with a 0.5-T imaging system on a phantom which consisted of an array of vials containing 2% agarose gels doped with various amount of Mn2+ using different combinations of the parameter set (tD, alpha). T1 results obtained with this technique were compared with those measured by a conventional inversion-recovery procedure using the same spectrometer. Strategic choice of pulse sequence parameters to minimize experimental errors and the criteria for these choices will be discussed.

Humans↗

Volume-selective and spectroscopically resolved NMR investigation of diffusion and relaxation in fertilised hen eggs.

A radiofrequency and field-gradient pulse sequence is presented permitting the non-invasive, volume-selective and spectroscopically resolved determination of incoherent transport parameters with the aid of an NMR field-gradient method. With proton NMR, diffusion or (quasi-incoherent) perfusion coefficients as low as 10(-12) m2 s-1 are accessible with gradients G less than or equal to 100 mT m-1 for T2 greater than or equal to 0.3 s. If coherent motions like flow are superimposed, the gradient pulses can be compensated for phase shifts arising from uniform or accelerated motions. The efficiency of the suppression of the influence of coherent motions was demonstrated in test experiments with phantom sample arrangements. As a biophysical application, the local diffusion coefficients D and relaxation times T1 and T2 of hen eggs were studied during the first days of incubation. In the yolk, strongly non-exponential decay curves were observed for the CH2 line. The translational displacements of water were found to be restricted. The relaxation and diffusion parameters turned out to be constant during the incubation. Medical applications of the pulse sequences are discussed. In one case we demonstrate that attempts to assign resonance lines can be checked by the condition that resonances of the same compound must have identical diffusion coefficients.

Animals↗

Dynamic echo planar MR imaging of lung ventilation with hyperpolarized (3)He in normal subjects and patients with severe emphysema.

We applied the rapid imaging capability of echo planar MR pulse sequences and hyperpolarized (3)He ventilation imaging to observe the dynamic distribution of gas in the lungs during breathing. Findings in five normal volunteers (age 19-53 years) and four patients with severe smoking-related emphysema (age 56-71 years) were compared. All studies were performed on a 1.5 T whole body scanner using a 30 cm Helmholtz surface coil and 0.5 l of 20-40% polarized (3)He mixed with 1-2 l nitrogen. Our echo planar imaging pulse sequence allowed acquisition of each image in 0.04 s, with a pixel size of 7 mm(2) (TR = 40.5 ms, TE = 12.1 ms, flip angle = 22 degrees, echo train length = 32, matrix = 32 x 64, field of view = 225 x 450 mm, slice thickness = 10 mm). Imaging was performed in the transaxial plane repeatedly at 3, 10 or 20 evenly spaced levels, immediately before and during breathing of the gas mixture. In normal subjects during the first breath, (3)He appeared throughout each slice first in the mid lungs, then in the lower lungs, then in the upper lungs, with slightly greater signal in the dependent posterior regions. In patients with emphysema, sequential filling of different lung regions was seen during the first breath, with delayed filling of other regions observed during rebreathing and room air washout. We conclude that subsecond dynamic (3)He MR ventilation imaging can reveal normal and abnormal ventilation phenomena not seen with conventional scintigraphic methods, and offers another approach to the study of ventilation physiology and pathophysiology.

Adult↗

Effect of microbubble exposure to ultrasound on quantitation of myocardial perfusion.

BACKGROUND: The purpose of this study was to determine whether acoustic disruption of microbubbles in the left ventricular (LV) cavity prior to entry in the coronary circulation or their gradual destruction in the myocardium during myocardial contrast echocardiography (MCE) affects quantitative parameters of myocardial perfusion. METHODS: MCE was performed in 12 open chest dogs with both intermittent high-power imaging (IHPI) and real-time low-power imaging (RLPI). To assess the affects of microbubble destruction in the LV cavity, MCE parameters of myocardial perfusion were compared for imaging planes that included versus avoided the LV cavity. To assess the effects of gradual disruption of microbubbles in the microcirculation during RLPI, MCE parameters from frames acquired continuously were compared to that from acquiring only end-systolic frames. RESULTS: Destruction of microbubbles in the LV cavity did not alter perfusion data for either form of imaging unless RLPI was performed using long (6-frame) destructive pulse sequences. With RLPI, a gradual decay in microbubble signal occurred during their myocardial transit, the degree of which was related to the acoustic power. Signal decay during microbubble transit resulted in an overestimation of the microvascular blood velocity (beta-value) and an underestimation of the microvascular blood volume (A-value). CONCLUSIONS: MCE parameters of perfusion at low power can be significantly altered by microbubble destruction in the LV cavity and in the myocardial microcirculation during RLPI. Short microbubble destruction pulse sequences and imaging only at end-systole can reduce these effects.

Analysis of Variance↗

Tissue contrast enhancement: image reconstruction algorithm and selection of TI in inversion recovery MRI.

It is clearly demonstrated that the proper application of the inversion recovery imaging pulse sequence is dependent on the method of image reconstruction and the selection of TI for optimum tissue contrast. There are two methods of 2DFT image reconstruction of IR sequence time-domain raw data. The first is a modulus-image reconstruction algorithm (contrast-obliterating option), and the second is a phase-correction routine for reconstructing "phase-sensitive" true IR-images. The second option generates proper "in-phase" images, retains proper scale of contrast, but can invert the algebraic sign of image-values under certain conditions. A series of "phase-sensitive" and "modulus" reconstructed brain images, obtained with conventional and optimized new IR pulse sequences, are shown to demonstrate these effects. They illustrate the considerable advantages gained, in practical clinical situations, if one generates "phase-sensitive" true IR-images from IR-sequence raw data at optimum TI for tissue contrast enhancement.

Algorithms↗

Signal strength on a 0.15-T magnetic resonance imager.

Signal strength in magnetic resonance (MR) images made on a 0.15-T imager was calculated for spin-echo (SE) and inversion-recovery with echo (ISE) pulse sequences and was compared to measurements of signal strength for aqueous MnCl2 solutions whose T1 and T2 relaxation times encompassed the range of values commonly found for tissues. Although measured signal strength generally agreed with calculated signal strength (correlation coefficient = 0.996 for both SE and ISE), significant reductions in measured strength (greater than 15%) were sometimes observed. Diffusion alone could not account for this discrepancy. Further experiments showed that imaging gradients reduced the effective T2 estimated from the imager. In addition, SE pulse sequences with short repetition times exhibited a reduction in signal strength.

Electron Spin Resonance Spectroscopy↗

MR imaging of experimentally induced intracranial hemorrhage in rabbits during the first 6 hours.

PURPOSE: To evaluate the MR appearance of intracranial, especially intraparenchymal, hemorrhage during the first 6 hours after bleeding with various pulse sequences in an animal model. MATERIAL AND METHODS: Intracerebral hematomas and subarachnoid hemorrhage were created by injecting autologous blood in 9 rabbits. MR studies were performed using a 1.5 T scanner with pixel size and slice thickness comparable to those used in clinical practice before blood injection, immediately after injection, and at regular intervals during 6 hours. The images were compared with the hematoma sizes on formalin-fixed brain slices. RESULTS: In every animal, susceptibility-weighted gradient-echo (GRE) pulse sequences depicted the intraparenchymal hematomas and blood escape in the ventricles or subarachnoid space best as areas of sharply defined, strong hypointensity. The findings remained essentially unchanged during follow-up. The sizes corresponded well to the post-mortem findings. Gradient- and spin-echo (GRASE) imaging revealed some hypointensities, but these were smaller and less well defined. Spin-echo (SE) sequences (proton density-, T1- and T2-weighted) as well as a fluid-attenuated inversion recovery turbo spin-echo sequence (fast FLAIR) depicted the hemorrhage sites as mostly isointense to brain. CONCLUSION: Susceptibility-weighted GRE imaging at 1.5 T is highly sensitive to both hyperacute hemorrhage in the brain parenchyma and to subarachnoid and intraventricular hemorrhage.

Animals↗

Investigation of acoustic noise on 15 MRI scanners from 0.2 T to 3 T.

Acoustic noise levels for fast MRI pulse sequences were surveyed on 14 systems with field strengths ranging from 0.2 T to 3 T. A microphone insensitive to the magnetic environment was placed close to the magnet isocenter and connected via an extension cable to a sound level meter outside the scan room. Measured noise levels varied from 82.5 +/- 0.1 dB(A) for a 0.23 T system to 118.4 +/- 1.3 dB(A) for a 3 T system. Further measurements on four of the closed-bore systems surveyed showed that: 1) pulse sequence parameters (particularly FOV and TR) were more influential in determining noise level than field strength, 2) the noise level was found to vary along the z-direction with a maximum near the bore entrance, and 3) in one of two systems tested there was a significant increase in noise with a volunteer present instead of a test object. The results underline the importance of hearing protection for patients and for staff spending extended periods in the scan room.

Ear Protective Devices↗

MR imaging of corpus callosotomy.

MR findings in 13 patients who underwent corpus callosotomy for medically intractable seizures were reviewed. Preoperative MR studies were available in nine patients: five showed at least one morphological and/or MR signal abnormality including corpus callosal thinning (four cases), cerebellar atrophy (two cases), cortical atrophy (two cases), and periventricular hyperintensity on T2-weighted images (one case). Four patients had normal MR studies. Postoperative MR studies were obtained in 11 patients with subtotal callosotomy and two with total callosotomy. Of all pulse sequences, sagittal T1-weighted images best showed the surgical division, although two cases displayed a coaptation artifact, which was misleading. A surgical clip placed at the posterior extent of the callosotomy was best visualized with sagittal T1-weighted imaging. Two patients (15%) had MR findings consistent with subacute blood in the callosum, and three patients (23%) demonstrated parafalcial hyperintensity on T2-weighted images 1 week after callosotomy. Motion artifact was a significant problem with coronal imaging and T2-weighted pulse sequences in postoperative patients. Patients selected for corpus callosotomy may have a normal baseline MR or show nonspecific abnormalities. MR imaging is an effective method for evaluating callosal division, and in some cases, may demonstrate signal changes consistent with surgically related edema and/or blood.

Adolescent↗

Nuclear magnetic resonance imaging in evaluation of clinical stroke syndromes.

Proton nuclear magnetic resonance (NMR) imaging was performed on normal volunteers and patients with various types of clinical strokes. True three-dimensional volumetric data were obtained for subsequent reconstruction of images at various orientations, including transverse, coronal, and sagittal, and for specific matching to x-ray computed tomographic planes. A variety of radiofrequency pulse sequences was used to generate images weighted by the NMR parameters spin density (p) and spin-lattice (T1) and spin-spin (T2) relaxation times. Quantitative T1 data and qualitative T2 information were obtained from appropriate sequences. Proton NMR images embodying T1 information provided adequate delineation of normal intracranial anatomical structure and a high level of gray matter-white matter contrast; high lesion detection sensitivity in various clinical forms of stroke was seen in images providing both T1 and T2 information. T1 and T2 relaxation times were prolonged in embolic, thrombotic, and watershed infarctions as well as in lacunae; shortening of T1 and T2 was found in hematomas. Serpiginous vessels in an arteriovenous malformation were seen that had particular pulse sequences.

Cerebellar Diseases↗

Improved measurement of (3)J(H(alpha)(i),N(i+1)) coupling constants in H(2)O dissolved proteins.

A modification to the recently proposed alpha/beta-HN(CO)CA-J TROSY pulse sequence (P. Permi et al., J. Magn. Reson. 146, 255-259 (2000)) makes it possible to determine (3)J(H(alpha)(i), N(i+1)) coupling constants from a single E.COSY-type cross-peak pattern rather than from two (1)H(alpha) spin-state-edited subspectra. Advantages are increased (15)N resolution, critical to extracting accurate (1)H(alpha)-(15)N coupling constants, and minimized differential relaxation due to nested (13)C(alpha) and (15)N evolution periods. Application of the improved pulse sequence to Desulfovibrio vulgaris flavodoxin results in (3)J(H(alpha)(i), N(i+1)) values being systematically larger than those obtained with the original scheme. Parametrization of the coupling dependence on the protein backbone torsion angle psi yields the Karplus relation (3)J(H(alpha)(i), N(i+1))=-1.00 cos(2)(psi-120 degrees )+0.65 cos(psi-120 degrees )-0.15 Hz, with a residual root-mean-square difference of 0.13 Hz between measured and back-calculated coupling constants. The curve compares with data derived from ubiquitin (A. C. Wang and A. Bax, J. Am. Chem. Soc. 117, 1810-1813 (1995)), although spanning a slightly larger range of J values in flavodoxin. The orientation of the Ala39/Ser40 peptide link, forming a type-II beta-turn in flavodoxin, is twisted against X-ray-derived torsions by approximately 10 degrees in the NMR structure as evident from the analysis of straight phi- and psi-related (3)J coupling constants. The remaining deviation of some experimental values from the prediction is likely to be due to strong hydrogen bonding, substituent effects, or the additional dependence on the adjacent torsions straight phi.

Flavodoxin↗

Magnetic resonance imaging of Achilles tendon in patients with rheumatoid arthritis.

RATIONALE AND OBJECTIVES: The authors characterize the appearance of the Achilles tendon in patients with rheumatoid arthritis and differentiate this appearance from degenerative tendinopathy in patients with chronic pain of the heel using magnetic resonance (MR) imaging. METHODS: Thirty patients with rheumatoid arthritis and 28 patients with chronic pain of the heel underwent MR imaging of the ankle and foot. Three radiologists independently assessed the MR images with respect to size, shape, and intratendinal signal characteristics of the Achilles tendon. The Achilles tendon was considered abnormal on MR imaging when intratendinous signal alterations or an anteroposterior measurement greater than 8 mm was seen. Physical examination of the Achilles tendons was accomplished in both groups. Operation confirmed the diagnosis of 13 patients in the second group with chronic pain of the heel. RESULTS: The Achilles tendon of 83% of patients with rheumatoid arthritis demonstrated various intratendinous patterns (longitudinal, reticular, nodular) of intermediate signal intensity on all pulse sequences on MR imaging. Ninety percent of patients with rheumatoid tendinopathy showed no enlargement of the anteroposterior diameter of the Achilles tendon. In addition, all patients with rheumatoid arthritis had findings compatible with an inflammation of the retrocalcaneal bursa on MR imaging, whereas none of the patients with tendinopathy associated with chronic heel pain had retrocalcaneal bursitis. All patients, however, had enlargement of the anteroposterior diameter of the Achilles tendon. Seventy-nine percent showed various intratendinous lesions of intermediate signal intensity on all pulse sequences. Twenty-one percent of patients had an enlargement of the Achilles tendon without intratendinous changes. CONCLUSIONS: Rheumatoid tendinopathy can be distinguished from degenerative tendinopathy in patients with chronic pain of the heel with MR imaging. Inflammation of the retrocalcaneal bursa and the absence of enlargement of the tendon combined with the presence of intratendinous signal alterations are characteristic findings of rheumatoid tendinopathy.

Achilles Tendon↗

Adrenal tissue characterization using MR imaging.

Using a superconducting magnet operating at 0.35 T, the authors investigated the adrenal tissue characterization potential of magnetic resonance (MR) in 28 patients with 33 adrenal masses. There were 13 adrenal adenomas (12 non-hyperfunctioning, one aldosteronoma), nine adrenal metastases, four pheochromocytomas, two neuroblastomas, two adrenal lymphomas, two myelolipomas, and one adrenal cortical carcinoma. Spin-echo pulse sequences were obtained at TR 0.5, 2.0 sec and TE 28, 56 msec. Both qualitative (visual assessment) and quantitative (absolute signal intensity, intensity ratios, T1, T2) data were used for tissue characterization. The results suggest that non-hyperfunctioning adrenal adenomas can be distinguished from non-adenomas using both qualitative and quantitative data: 16/19 non-adenomas were visually hyperintense compared with liver at TR 2.0 sec, TE 56 msec, while none of the non-hyperfunctioning adenomas was relatively hyperintense at any pulse sequence used. Of the quantitative data, the intensity ratios of adrenal lesion/liver at TR 0.5 sec, TE 56 msec were most useful in diagnosis: all adenomas had ratios less than 0.83, while 19/20 non-adenomas had ratios exceeding this value. It is concluded that MR has considerable promise in adrenal tissue characterization.

Adenoma↗

Magnetic resonance imaging of the cervical spine: technical and clinical observations.

Seventy-two patients were examined to determine the clinical potential for magnetic resonance imaging (MRI) of the spine. MRI using different pulse sequences was compared with plain radiography, high-resolution computed tomography, and myelography. There were 35 normal patients; pathologic conditions studied included canal stenosis, herniated disk, metastatic tumor, neurofibroma, trauma, Chiari malformation, syringomyelia, arteriovenous malformation, and rheumatoid arthritis. MRI provided sharply defined anatomic delineation and tissue characterization. It was diagnostic in syringomyelia and Chiari malformation and was useful in the evaluation of trauma and spinal canal block from any cause. MRI was sensitive to degenerative disk disease and infection. The spin-echo technique, with three pulse sequence variations, seems very promising. A short echo time (TE) produces the best signal-to-noise ratio and spatial resolution. Lengthening the TE enhances differentiation of various tissues by their signal intensity, while the combined increase of TE and recovery time (TR) produces selective enhancement of the cerebrospinal fluid signal intensity.

Arnold-Chiari Malformation↗

Differentiation of hepatic metastases from hepatic hemangiomas and cysts by using MR imaging.

T1-weighted and T2-weighted pulse sequences were employed for MR imaging of hepatic metastatic tumors (98 patients), hemangiomas (24 patients), and cysts (seven patients); a 0.6-T superconducting magnet was used. In a retrospective study, signal intensity and morphology were used to establish criteria for differentiating metastases from hemangiomas and cysts. The signal intensity of the lesion alone failed to be an etiologic discriminator because over 96% of all masses had a signal intensity less than that of liver on T1-weighted sequences, and at least 90% had a signal intensity greater than that of liver on T2-weighted sequences. Morphologic features depicted on T2-weighted images were more specific than those depicted on T1-weighted images in differential diagnosis. Amorphous, target, and halo signs and a change in morphology were present only in metastatic disease, with a frequency of 45%, 27%, 13%, and 12%, respectively. Two other morphologic patterns--doughnut and lightbulb signs--were found to have overlapping causes. Overall, at least one of the specific signs was observed in 92% of patients with metastatic disease. These data suggest that T2-weighted pulse sequences are essential for discriminating between hepatic metastases and hepatic hemangiomas and cysts. MR imaging is a promising technique for distinguishing these lesions.

Cysts↗

Spherical navigator echoes for full 3D rigid body motion measurement in MRI.

We developed a 3D spherical navigator (SNAV) echo technique that can measure rigid body motion in all six degrees of freedom simultaneously by sampling a spherical shell in k-space. 3D rotations of an imaged object simply rotate the data on this shell and can be detected by registration of k-space magnitude values. 3D translations add phase shifts to the data on the shell and can be detected with a weighted least-squares fit to the phase differences at corresponding points. MRI pulse sequences were developed to study k-space sampling strategies on such a shell. Data collected with a computer-controlled motion phantom with known rotational and translational motions were used to evaluate the technique. The accuracy and precision of the technique depend on the sampling density. Roughly 2000 sample points were necessary for accurate detection to within the error limits of the motion phantom when using a prototype time-intensive sampling method. This number of samples can be captured in an approximately 27-ms double excitation SNAV pulse sequence with a 3D helical spiral trajectory. Preliminary results with the helical SNAV are encouraging and indicate that accurate motion measurement suitable for retrospective or prospective correction should be feasible with SNAV echoes.

Humans↗

Oscillating dual-equilibrium steady-state angiography.

A novel technique of generating noncontrast angiograms is presented. This method, called oscillating dual-equilibrium steady-state angiography (ODESSA), utilizes a modified steady-state free precession (SSFP) pulse sequence. The SSFP sequence is modified such that flowing material reaches a steady state which oscillates between two equilibrium values, while stationary material attains a single, nonoscillatory steady state. Subtraction of adjacent echoes results in large, uniform signal from all flowing spins and zero signal from stationary spins. Venous signal can be suppressed based on its reduced T2. ODESSA arterial signal is more than three times larger than that of traditional phase-contrast angiography (PCA) in the same scan time, and also compares favorably with other techniques of MR angiography (MRA). Pulse sequences are implemented in 2D, 3D, and volumetric-projection modes. Angiograms of the lower leg, generated in as few as 5 s, show high arterial signal-to-noise ratio (SNR) and full suppression of other tissues.

Artifacts↗

Spectral simulations incorporating gradient coherence selection.

Computer-aided methods can considerably simplify the use of the product operator formalism for theoretical analysis of NMR phenomena, which otherwise becomes unwieldy for anything but simple spin systems and pulse sequences. In this report, two previously available programming approaches using symbolic algebra (J. Shriver, Concepts Magn. Reson. 4, 1-33, 1992) and numerical simulation using object-oriented programming (S. A. Smith, T. O. Levante, B. H. Meier, and R. R. Ernst, J. Magn. Reson. A 106, 75-105, 1994) have been extended to include the use of gradient operators for simulation of spatially localized NMR spectroscopy and gradient coherence selection. These methods are demonstrated using an analysis of the response of an AX(3) spin system to the STEAM pulse sequence and verified with experimental measurements on lactate.

Computer Simulation↗