The effect of 'running-in' on the tribology and surface morphology of metal-on-metal Birmingham hip resurfacing device in simulator studies.

It is well documented that hard bearing combinations show a running-in phenomenon in vitro and there is also some evidence of this from retrieval studies. In order to investigate this phenomenon, five Birmingham hip resurfacing devices were tested in a hip wear simulator. One of these (joint 1) was also tested in a friction simulator before, during, and after the wear test and surface analysis was conducted throughout portions of the testing. The wear showed the classical running in with the wear rate falling from 1.84 mm3 per 10(6) cycles for the first 10(6) cycles of testing to 0.24 mm3 per 10(6) cycles over the final 2 x 10(6) cycles of testing. The friction tests suggested boundary lubrication initially, but at 1 x 10(6) cycles a mixed lubrication regime was evident. By 2 x 10(6) cycles the classical Stribeck curve had formed, indicating a considerable contribution from the fluid film at higher viscosities. This continued to be evident at both 3 x 10(6) and 5 x 10(6) cycles. The surface study complements these findings.

Biocompatible Materials↗

'Severe' wear challenge to 'as-cast' and 'double heat-treated' large-diameter metal-on-metal hip bearings.

The wear generation of double-heat-treated and as-cast large-diameter metal-on-metal (MOM) hip bearings was investigated using standard- and 'severe'-gait simulations. The test hypothesis was that double heat treatment would change MOM hip wear compared with the as-cast condition. Two groups of high-carbon MOM bearings of 40 mm diameter were manufactured and subjected to either hot isostatic pressing (HIP) and solution annealing (SA) or no heat treatment (as cast). The results showed no statistical difference between the two groups under both running-in and steady state conditions. Even under the most 'severe'-gait simulation published to date, the mean volumetric wear rates were 2.9 and 3.9 mm3 per 10(6) cycles for the HIP-SA and as-cast bearings respectively, showing a ten-fold increase in wear compared with walking. These differences were not statistically different; therefore our hypothesis was negated. Changes in alloy microstructure do not appear to influence the wear behaviour of high-carbon cast MOM articulations with similar chemical compositions. This is in sharp contrast with the published significance of bearing diameter and radial clearance on the wear of MOM hip bearings.

Biocompatible Materials↗

Metal-on-metal hip simulator study of increased wear particle surface area due to 'severe' patient activity.

This study investigated changes in metal-on-metal (MOM) hip wear and wear particle characteristics arising from a more aggressive patient activity level compared with normal walking. The test hypothesis was that 'severe'-gait conditions will change wear, wear particle sizes, and morphology owing to a decline in joint lubrication. Four carbon MOM hip bearings 40 mm high were subjected to normal-walking and fast-jogging simulations in an orbital hip joint simulator with 25 per cent alpha-calf serum as a lubricant. Co-Cr-Mo wear particles were extracted using an enzymatic method, and prolate ellipsoid equations were used to estimate particle volume and surface area. Fast-jogging simulations generated a sevenfold increase in volumetric wear, a 33 per cent increase in mean wear particle size, and a threefold increase in the number of larger (needle) particles compared with walking. This resulted in a twentyfold increase in total wear particle surface area per 10(6) cycles compared with walking, thereby confirming our hypothesis. The clinical significance of this result suggests that highly active MOM patients may exhibit greater ion release than less active patients.

Biocompatible Materials↗

Late failure of the Manchester prosthesis. Its relationship to the disease process.

The results of thirty-one Manchester knee arthroplasties performed on twenty-eight patients are reviewed. There were sixteen patients with rheumatoid arthritis all of whom were satisfactory at the time of follow-up. Of the fifteen patients with osteoarthritis over half the arthroplasties failed after between twelve and thirty-six months. We suggest that resurfacing arthroplasty of the knee using the Manchester prosthesis should be used only for rheumatoid patients.

Adult↗

[Cytokine profile of a human bone marrow cell culture under the influence of UHMW-PE wear particles].

There is considerable evidence that orthopaedic wear debris plays a crucial role in the pathology of aseptic loosening of joint prostheses. The purpose of the present study was to evaluate the influence of ultra-high-molecular-weight polyethylene (UHMW-PE) on the cytokine response in a modified in vitro model. UHMW-PE particles (psi < 7.5 microm) were suspended in soluble collagen type I and subsequently solidified in different concentrations (105,106 and 107 particles per well) on the bottom of the wells. Human bone marrow cells in a concentration of 3 x 106 cells per well were seeded on the collagen-particle substrata and maintained for up to 12 days. The cytokine response (IL-1_, IL-6 and TNF-_) of the cells to the particles were examined by ELISA compared to cells on control collagen surfaces without any particles. Assays for viability using LDH activity were done immediately. Light and scanning microscopic evaluation revealed that the UHMWPE particles, which have built large conglomerates (psi7.5_m), were mainly surrounded by the cells and less phagocytosed. The results of the cytokine release revealed significant differences in interleukin (IL)6, tumor necrosis factor (TNF)- _ and IL-1beta. The cell viability was not affected by the UHMW-PE particles. The results demonstrate that the particle induced cytokine response by UHMW-PE is mainly by the release of Interleukin 6 and TNF- _. Moreover the results confirm that the present method is useful to evaluate the in vitro effects of UHMW-PE wear particles with direct particle cell contact.

Bone Marrow Cells↗

[Stretched polyethylene (UHMWPE)--a new substance modification for minimizing wear in artificial knee joint replacement].

Polyethylene wear is a major cause of aseptic loosening of knee endoprostheses. With the aim of minimizing this mechanical wear, we stretch-modified the structure of polyethylene. From plates of UHMWPE, stretched PE samples were produced under defined conditions, and subsequently submitted to friction tests in a fluid environment (cycles 5 x 10(5), frequency 1.5 Hz, load 500 N, contact stress 10 MPa). After load testing, the stretched samples revealed a 70% reduced wear rate in comparison with non-stretched samples. Microscopic examination (light microscopy, scanning electron microscopy) showed abrasive scratches in all test samples, but only in the non-stretched specimens were signs of pitting found. Translating these results to unidirectional tractive rolling on the tibial plateau in the knee joint suggests that a significant reduction in polyethylene wear can be expected. However, further experimental investigations need to be carried out to confirm this highly promising possibility.

Elasticity↗

Retrieval analyses of implanted biomaterials: light microscopic and scanning electron microscopic analyses of implants retrieved from humans.

We report analyses obtained from 135 implant cases retrieved from humans and submitted to the American Academy of Implant Dentistry Research Foundation--Medical College of Georgia Implant Retrieval Center. The undecalcified samples were embedded in polymethyl-methacrylate and examined with scanning electron microscopy and with routine light via polarized or Nomarski microscopy. Cases included both orthopedic and dental implants as well as entire mandibles obtained at autopsy. Significant numbers of submitted implants had substantial amounts of adhered bone, which permitted evaluation of human bone remodeling to osseointegrated implants. These implants failed because of implant fracture. As has been observed in animal studies, an interdigitating canaliculi network provided communication between interfacial osteocytes and osteocytes deeper within the remodeled osteonal and trabecular bone. Significant numbers of osseointegrated fractured hydroxyapatite-coated dental implants demonstrated the adequate serviceability of these implants prior to biomaterial fracture. In contrast, the hydroxyapatite coating was dissociated from retrieved orthopedic implants, leading to extensive cup loosening and case failure. Caution is advised for the use of hydroxyapatite-coated acetabular implants. This study therefore underscores the need for evaluation of failed human dental and orthopedic implants. Correlations can be drawn between human retrieval and experimental animal studies.

Aged↗

Mechanical heart valve cavitation.

Cavitation was first directly related to mechanical heart valves in the mid 1980s after a series of valve failures observed with the Edwards-Duromedics valve. The damages observed indicated that cavitation could be responsible. Later, several in vitro studies visualized the bubble formation and collapse of cavitation at mechanical heart valves. It was suggested that cavitation could also cause damage to the formed elements of blood and thereby enhance the risk of thromboembolic complications seen in mechanical heart valve patients. Therefore, an applicable technique for in vivo detection of cavitation is required. This article reviews techniques developed for in vivo detection of cavitation and suggests focus for future studies.

Computer-Aided Design↗

Three-dimensional analysis of multiple wear vectors in retrieved acetabular cups.

The wear of polyethylene acetabular components is an important issue in total hip arthroplasty. The amount of wear has been measured in many studies, but few have addressed other mechanical aspects of wear in vivo. We used the shadowgraph method to measure the wear vectors in 104 retrieved acetabular cups that had been made by a single manufacturer, and we identified more than one wear vector in thirty-one cups (30 per cent). We hypothesized that the most likely explanation of multiple wear vectors was loosening of the acetabular implant with a change in the orientation of the implant in the pelvis. To test this hypothesis, we estimated the extent of motion of the cup in situ on the basis of differences in angles measured from serial radiographs of sixteen hips. We then used linear transformation of the three-dimensional vectors to compare the wear directions measured in the retrieved implants with the wear directions predicted from the radiographs. The change in wear direction predicted on the basis of in vivo motion of the cup never corresponded to the actual difference between wear vectors in the retrieved implants. Our results suggest that multiple wear vectors may be commonly found in retrieved implants, but loosening of the acetabular cup does not account for the multiple vectors. Additional observations suggest that impingement between the edge of the acetabular cup and the femoral component may be associated with multiple wear vectors. These results have implications for the investigation of the general mechanisms of wear in vivo and suggest that clinical or wear-testing scenarios that assume a single direction of wear may underestimate the over-all amount of volumetric wear.

Equipment Failure Analysis↗

Revision of a cemented acetabular component to a cementless acetabular component. A ten to fourteen-year follow-up study.

BACKGROUND: Although cementless acetabular components are routinely used in revision hip surgery, few investigators have evaluated the retention and efficacy of these components in the long term. In the current study, the clinical and radiographic outcomes of a series of arthroplasties performed by one surgeon with a cementless acetabular component were assessed at a minimum of ten years. METHODS: From 1986 through 1988, sixty-one consecutive revision total hip arthroplasties were performed in fifty-five patients because of aseptic failure of one or both components of a prosthesis in which both components had been cemented. Twenty-eight patients (thirty-two hips) were alive at a mean of 12.9 years (range, 11.5 to 14.3 years) after the operation. In all of the patients, the acetabular component was revised to a porous-coated Harris-Galante component inserted without cement, and the femoral component was revised to an Iowa component affixed with contemporary cementing techniques. The hips were evaluated clinically and radiographically at a minimum of ten years subsequent to the index revision. No hips were lost to follow-up. RESULTS: None of the acetabular components required revision because of aseptic loosening. Two hips (3%) demonstrated radiographic evidence of aseptic loosening of the acetabular component. The polyethylene liner was exchanged during the follow-up period in eight hips. CONCLUSION: After a minimum of ten years of follow-up, cementless acetabular fixation in revision hip arthroplasty had produced durable results that were markedly better than those reported for acetabular fixation with cement.

Acetabulum↗

Comparison of preoperative radiographs and intraoperative findings of fixation of hemispheric porous-coated sockets.

BACKGROUND: The radiographic criteria for identification of loose cementless acetabular components have not been well established. The purpose of this study was to compare the radiographic appearance of a hemispheric porous-coated cementless cup fixed with screws with the intraoperative findings with regard to the fixation status. METHODS: The quality of the cup fixation was evaluated at fifty-two hip revisions that were performed, for reasons other than infection, at an average of 89.9 months (range, 33.8 to 150.1 months) after the primary operations. The fixation status at the revision surgery was compared with the findings on sequential anteroposterior and lateral radiographs of these sockets. Sequential radiographs of an additional 100 total hip replacements that had not required a reoperation and that had been followed for an average of 121 months were also measured. RESULTS: Loosening of the socket was radiographically identified by (1) radiolucent lines that initially appeared after two years, (2) progression of radiolucent lines after two years, (3) radiolucent lines in all three zones, (4) radiolucent lines 2 mm or wider in any zone, or (5) migration. The sensitivity of these criteria was 94%, and the specificity was 100%. The criteria had a positive predictive value of 100% and a negative predictive value of 97%. CONCLUSIONS: The most predictive radiographic findings for early diagnosis of loosening of a hemispheric porous-coated cup were progression of radiolucent lines more than two years after the operation and any new radiolucent line of 1 mm or wider that appeared more than two years postoperatively. Sequential anteroposterior and lateral radiographs are necessary to assess the time of onset and progression of radiolucent lines in order to identify loose hemispheric porous-coated cups accurately.

Acetabulum↗

Analysis of polyethylene thickness of tibial components in total knee replacement.

BACKGROUND: Excessive wear of the polyethylene bearing surfaces of tibial components has become an important factor in early failure of total knee arthroplasty. Inadequate thickness of the polyethylene insert is one cause of excessive wear, and various minimum thicknesses have been recommended in order to reduce contact stresses within the polyethylene. However, the true thicknesses of modular polyethylene tibial inserts typically are not stated accurately by the manufacturers in their product information. The purpose of this study was to determine whether the information about the thickness of tibial inserts supplied by the manufacturers is adequate. METHODS: Five of the thinnest available polyethylene tibial inserts from five different manufacturers were selected. The minimum thickness of each was measured with use of a Sigma electronic micrometer comparator to an accuracy of +/-0.005 mm. RESULTS: The stated thicknesses of the polyethylene tibial inserts were 8, 9, and 10 mm, values that differed markedly from the actual minimum thicknesses, which ranged from 5.5722 to 6.2048 mm (mean values). CONCLUSION: The thickness of polyethylene tibial inserts has been implicated as a potential cause of excessive wear and early failure of total knee replacements. This paper highlights the fact that the information supplied by the manufacturers is inaccurate and potentially misleading; in one case, the true thickness was much less than the recommended minimum thickness. We recommend that the minimum thickness of the tibial components as well as the combined thickness of the polyethylene insert and the metal tibial tray be specified in the product information and on the packaged insert.

Arthroplasty, Replacement, Knee↗

Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners.

BACKGROUND: A higher degree of cross-linking has been shown to improve the tribological properties of ultra-high molecular weight polyethylene in laboratory studies; however, its effect on in vivo behavior has not been well established. We investigated in vivo wear mechanisms in retrieved highly cross-linked polyethylene acetabular liners in order to determine if early in vivo wear behavior is accurately predicted by hip-simulator studies. METHODS: A total of twenty-four liners (twenty-one explanted and one unimplanted highly cross-linked liners and two explanted ethylene-oxide-sterilized non-cross-linked liners) were examined for this study. The average age of the patients was 59.9 years, and the average time in vivo was 10.1 months. Articular surface damage on the front and back sides of the liners was assessed with an optical scoring system. Surface quadrants were assigned a grade from 0 to 3 according to the observed wear mechanisms and the percentage of surface affected. The micromechanisms of liner damage were evaluated with use of scanning electron microscopy. RESULTS: The average front and back-side explant damage scores were 11 (range, 2 to 26.5) and 6.7 (range, 3.7 to 13.3), respectively. There was consistent evidence of early surface deformation and cracking. All explants exhibited some form of surface change, including surface cracking, abrasion, pitting, or scratching. The original machining marks on the liner surface were observed to be either unaltered, drastically distorted, or absent. CONCLUSIONS: Highly cross-linked ultra-high molecular weight polyethylene acetabular liners that were retrieved at an average of ten months after implantation exhibited signs of surface damage that had not been predicted by in vitro hip-simulator studies. These devices had not failed clinically as a result of wear. The discrepancy between in vitro and in vivo wear surfaces may be due to variability in terms of in vivo lubrication and cyclic loading or may represent early surface damage mechanisms that are not well demonstrated by long-term simulator studies.

Acetabulum↗

Advancement and separation of apex hole eliminators with cementless Duraloc 100 cups. A report of nineteen cases.

BACKGROUND: From 1992 to 1996, we performed 541 cementless total hip arthroplasties using a Duraloc 100 acetabular component with an apex hole eliminator that did not have a positive stop design. During routine follow-up radiographic evaluation, we noted several hips with advanced or separated hole eliminators. This study presents the clinical consequences of this occurrence and its relationship to polyethylene wear and osteolysis. METHODS: A total of 541 hips (358 with a minimum duration of follow-up of five years) were evaluated clinically with use of the method of Merle D'Aubigné and Postel. Anteroposterior pelvic and iliac oblique radiographs were used to evaluate polyethylene wear, osteolysis, hole eliminator position, and component stability. RESULTS: Nineteen hips that had been followed for an average of eighty-nine months showed advancement or complete separation of the hole eliminator on radiographic evaluation. In most hips, advancement of the hole eliminator was visible on only the iliac oblique radiograph. In all but one hip with separation of the hole eliminator, complete plug separation was detectable on both the iliac oblique and anteroposterior pelvic radiographs. No association was found between polyethylene wear and either advancement or separation of the hole eliminator. No osteolysis was visible radiographically in the hips with hole eliminator advancement, but osteolysis was always visible in the hips that had complete separation of the hole eliminator. CONCLUSIONS: The hole eliminator has been redesigned since November 1995 to prevent possible advancement. However, patients with earlier designs should be followed carefully because advancement or separation can be expected in about 5% of the patients who have been followed for a minimum of five years. Despite this complication, which is seen radiographically, all patients were satisfied with the function of the hip. We do not recommend surgery solely to remove or replace the hole eliminator.

Adult↗

Increased expression of EMMPRIN in the tissue around loosened hip prostheses.

Matrix metalloproteinases (MMPs) have been shown to play a role in aseptic loosening of total hip replacement (THR). Extracellular matrix metalloproteinase inducer (EMMPRIN) can upregulate expression of several MMPs but has little effect on their tissue inhibitor (TIMP). Using the avidin-biotin-peroxidase complex immunostaining method, we detected strong immunoreactivity of EMMPRIN in the lining-like layers, sublining area and vascular endothelium of synovial membrane-like interface tissue around loosened prostheses. In contrast, EMMPRIN staining was very weak in the synovial samples from patients with hip arthrosis. Double immunofluorescence labeling revealed EMMPRIN/MMP-1 double-positive cells in lining-like layers and the sublining area of interface tissue. Our findings indicate that EMMPRIN expression is upregulated in interface tissue, and that locally accumulated EMMPRIN may modulate MMP-1 expression. An imbalance in the activity of MMPs and TIMP may lead to tissue destruction and periprosthetic osteolysis. These biological responses, combined with mechanical stress caused by micromotion and oscillating fluid pressure, may eventually cause aseptic loosening of THR.

Adult↗

Push-out strength of hydroxyapatite coated by sputtering technique in bone.

Hydroxyapatite was coated with 1 microm thickness on titanium columns of a length of 10 mm, an outer diameter of 4.0 mm by radio frequency magnetron sputtering. The hydroxyapatite coating titanium columns were implanted in the diaphysis of femora of 3 adult dogs, and push-out test was carried out after 2, 4 and 12 weeks of implantation using a testing machine. The interface of bone/column was observed histologically after the test. At 12 weeks the push-out strengths of coating and non-coating columns were 3.5 and 1 MPa, respectively. Histological observation indicated a formation of thin connective tissue with 5-30 microm thickness at the interface of the bone/column. No inflammation was observed during the implantation periods.

Animals↗