Fractured occluder disc: a previously unrecognized complication of the Starr-Edwards disc prosthesis.

Fracture of the occluder disc of a low-profile Starr-Edwards prosthesis is a hitherto unrecognized complication. We describe a patient who presented with right heart failure and severe pulmonary hypertension 27 years after mitral valve replacement with a model 6520 caged-disc prosthesis. At surgery, there was a longitudinal split in the occluder disc, and organized thrombus was lodged between the split segments. This case offers a unique opportunity to study the long-term effects of wear on the polyethylene poppet and Stellite cage.

Echocardiography, Doppler, Color↗

Hoarseness as the initial clinical presentation of anomalous left coronary artery from the pulmonary artery.

Anomalous origin of the left coronary artery from the pulmonary artery is a rare congenital anomaly that, if left untreated, will most often result in severe myocardial ischemia and significant morbidity and mortality. We report an unusual presentation of this defect in a 2-month-old infant who had an initial complaint of a "hoarse cry." We theorize that impingement of the recurrent laryngeal nerve due to dilatation of the pulmonary artery was the most likely etiology of the patient's symptoms. This case serves as an important reminder that serious congenital heart disease may present with any number of complaints and unusual findings.

Blood Vessel Prosthesis Implantation↗

Retention and marginal adaptation of a compomer placed in non-stress-bearing areas used with the total-etch technique: a 3-year retrospective study.

The aim of this clinical study was to evaluate class V and class III cavities restored with a polyacid-modified resin composite (compomer) restorative material in association with two different dentin-enamel bonding systems: Dyract-PSA (Primer Sealer Adhesive-DentSply, Germany) and Prime & Bond 2.0 (DentSply, Germany). The control group was a hybrid composite used with ProBond bonding system (DentSply, Germany). A total of 116 restorations (79 class V, 37 class III) were made and reevaluated after 1, 2 and 3 years in 55 patients in two private practices and in a university department. Class V nonretentive cavities were located at the CEJ level and class III at interproximal level close to CEJ. Each cavity was prepared using a water-cooled, high-speed handpiece with a fine diamond burr. A small bevel was prepared along enamel margin. Cavity dimensions were no more than 3.5 x 3.5 mm (using burr as reference point). Each restoration was finished immediately with fine diamond burrs and Sof-Lex disks (3 M, USA). The criteria that were evaluated by the USPHS method included: retention, color match, marginal integrity, marginal discoloration, and secondary caries. Results indicated that all compomer restorations were fully retained at 3 years, and that no secondary caries detected. Seven composite restorations were lost during the 3-year study. No statistical differences were observed between class III and class V or among other conditions (e.g., upper-lower arc, sex, age). This study demonstrates that compomers are suitable restorative materials for class III-V restorations. They may represent a clinical alternative to composites in class V and III restorations.

Adult↗

Late infective endocarditis after cholecystectomy in a patient with repaired tetralogy of Fallot: a case report.

Late endocarditis after surgical repair of tetralogy of Fallot is rare. We describe a case of endocarditis following cholecystectomy in a 22-year old patient with repaired tetralogy of Fallot. After cholecystectomy, the patient was referred to a cardiology clinic with unexplained fever and suspicion of endocarditis. Echocardiography revealed a large mass at the basal level of interventricular septum. Endocarditis was diagnosed on the basis of clinical and echocardiographic findings and antibiotic treatment was initiated immediately. Nine days later, the clinical status of the patient deteriorated and urgent surgery was performed. Patch dehiscence which mimicked a large vegetation, and multiple vegetations on the patch were found during operation. The patch was removed and ventricular septum defect was repaired with a new dacron patch. Enterobacter agglomerans was isolated in the vegetation cultures.

Adult↗

Pseudoaneurysms of the mitral-aortic intervalvular fibrosa: dynamic characterization using transesophageal echocardiographic and Doppler techniques.

OBJECTIVES: The aim of this study was to provide a detailed description of echocardiographic and Doppler features of pseudoaneurysms involving the mitral-aortic intervalvular fibrosa and to compare echocardiographic and aortographic findings. BACKGROUND: Infection of the aortic valve may spread to the aortic annulus, resulting in ring abscesses or pseudoaneurysms, or both, of the intervalvular fibrosa, which can alter patient management and prognosis. METHODS: The echocardiographic and Doppler findings of 20 patients with pseudoaneurysms or ring abscesses, or both, were reviewed and compared with surgical and aortographic results. RESULTS: A total of 23 lesions were identified, of which 16 were intervalvular pseudoaneurysms, and 7 were ring abscesses. Transthoracic echocardiography detected 43% of the lesions, whereas transesophageal echocardiography identified 90% (p < 0.01). The most distinct feature of the pseudoaneurysms was marked pulsatility, with systolic expansion and diastolic collapse (mean systolic area [+/- SD] 4.1 +/- 3.4 cm2 vs. diastolic mean area 1.8 +/- 2.2 cm2, p < 0.05). Using color Doppler, two types were identified: unruptured pseudoaneurysms (n = 9), which communicated only with the left ventricular outflow tract and had a distinct flow pattern, and ruptured pseudoaneurysms (n = 7), which, in addition, communicated with the left atrium or aorta. Compared with pseudoaneurysms, ring abscesses were smaller and nonpulsatile and showed either no flow or continuous systolic and diastolic flow, the site of paravalvular aortic insufficiency. In 10 patients who underwent aortography, three lesions were identified, and findings were concordant with echocardiography. However, in seven patients aortographic findings were normal, whereas echocardiography identified intervalvular pseudoaneurysms, all of which were documented at operation. CONCLUSIONS: Intervalvular pseudoaneurysms are more frequently detected by transesophageal echocardiography than by aortography or transthoracic examination and exhibit distinct dynamic features and Doppler patterns that can further help characterize cavitary lesions in the aortic root and guide appropriate surgical intervention.

Adult↗

Regression of ventricular repolarisation inhomogeneity after aortic bileaflet valve replacement in patients with aortic stenosis.

BACKGROUND: Aortic valve replacement relieves mechanical outflow obstruction in patients with aortic stenosis. However, there is limited information on whether aortic valve replacement can provide regression of ventricular repolarisation inhomogeneity. OBJECTIVES: To determine whether aortic valve replacement can provide regression of ventricular repolarisation inhomogeneity in patients with aortic stenosis after bileaflet aortic valve replacement. METHODS: We studied the changes of electrocardiographic QT or QTc intervals and QT or QTc dispersions of 71 patients with severe aortic stenosis and angiographically insignificant coronary lesions (<50% in diameter) before and after valve replacement (6+/-3 days after operation). Seventy-one healthy control subjects, matched for age and sex, served as control subjects. Twelve-lead electrocardiograms and echocardiographic examinations were measured before and after surgery. The QT interval was corrected for heart rate using the standard Bazett formula. QT dispersion was defined as the difference between maximal and minimal QT interval measurements occurring among any of the 12 leads on a standard electrocardiogram. QTc dispersion was calculated in a manner similar to QT dispersion. No subject had fewer than nine measurable leads. RESULTS: Left ventricular systolic blood pressure, pressure gradient across aortic valve, left ventricular mass index, and systolic wall stress were significantly reduced after valve replacement compared with before valve replacement. The QT interval significantly decreased from 425+/-38 ms to 398+/-32 ms after replacement (P<0.0001). The QTc dispersion significantly decreased from 62+/-25 ms to 32+/-13 ms after replacement (P<0.0001). The value of QT or QTc dispersion after replacement was similar to that in controls. Univariate analysis revealed that QTc dispersion was significantly only correlated with left ventricular mass index (r=0.236, P=0.05). Multivariate analysis revealed that the best predictor of QTc dispersion was sex and left ventricular mass index (P=0.008 and 0.005, respectively). CONCLUSIONS: Our study demonstrated a favorable consequence of aortic valve replacement distinct from hemodynamic improvement. Patients with aortic stenosis before valve replacement have abnormal prolonged QT or QTc intervals and increased QT or QTc dispersions. After successful valve replacement left ventricular mass index regressed and QT or QTc intervals and QT or QTc dispersions were normalized. These findings warrant further investigation in a large trial and long-term follow-up for clinical implications.

Aortic Valve↗

Up to seven years of experience with the Ross procedure in patients >60 years of age.

OBJECTIVES: The objective of this study was to compare the outcome of patients >60 years of age with younger patients after the Ross procedure. BACKGROUND: Currently, the Ross procedure is performed predominantly in young patients. Main arguments against the Ross procedure in the elderly are the complexity of the operation and related risks. Experience with the Ross procedure in patients >60 years of age is scarce. METHODS: Between February 1990 and August 1998, the Ross procedure was performed in 27 patients (15 men and 12 women) >60 years of age (mean 64.2 +/- 3.1 years, range 60.5 to 70.6; group A) and in 84 patients (68 men, 12 women) <60 years of age (mean 43.8 +/- 12.4 years, range 15.2 to 59.4; group B). Echocardiography was applied at a mean follow-up of 28.4 +/- 21.0 and 25.2 +/- 21.4 months, respectively, to determine hemodynamic variables (ejection fraction, fractional shortening, stroke volume, cardiac output), cardiac dimensions and autograft and homograft valve function. RESULTS: There was one early and one late (esophageal bleeding) death in group B; the mortality rate was 0% in group A. One autograft was replaced because of a subvalvular aneurysm, and one patient was lost to follow-up (group B). There were no significant differences in cardiac dimensions, grade of insufficiencies across homografts and autografts and hemodynamic variables, except for a higher pressure gradient across the homograft in group B (maximal pressure gradient 11.3 +/- 5.6 vs. 7.7 +/- 4.6 mm Hg in group A). The median New York Heart Association functional class was I in both groups. CONCLUSIONS: Our seven years of experiences (mean follow-up 28 months) indicate that the Ross procedure may be performed in selected patients >60 years of age without increased risk for mortality or complications in experienced centers.

Adolescent↗

Fibrotic aortic stenosis in a patient with dwarfism.

In this report, we present an adult patient with dwarfism who had severe aortic stenosis with markedly thickened fibrotic valve leaflets without calcification. These findings were well demonstrated by both two- and three-dimensional transesophageal echocardiography and confirmed at surgery and by pathological examination.

Adult↗

Leakage of interim post and cores used during laboratory fabrication of custom posts.

The aim of this study was to compare coronal microleakage in two conditions. Twenty-eight extracted upper molars were endodontically treated and divided into two groups and controls: group A: prefabricated post and core permanently cemented; and group B: prepared for a post and restored with a temporary post crown cemented with a temporary cement. The teeth were thermocycled, immersed in black India ink for 1 week, and made transparent. Results indicated that the permanently cemented, prefabricated post and core produced the best seal (p < 0.01); leakage was significantly greater with the temporary post crown and was similar to that of a positive control group.

Acrylic Resins↗

Treating with spectacle lenses: a novel idea!?

A design approach to low-vision device development-vision multiplexing-was introduced recently. This approach has been applied successfully to the design of novel electronic and optical low-vision aids. This paper discusses the application of the vision-multiplexing concept to spectacle lens design to address issues of low vision and to resolve problems of color discrimination and glare in driving. Because spectacles are considered a fashion accessory as much as they are a vision aid, cosmetic considerations are critical to the design of such aids. Spectacle-borne devices that are not concealed or attractive are unlikely to be used widely. Efforts to combine the functionality of vision multiplexing with improved appearance are illustrated.

Biomedical Engineering↗

St. Jude SPV versus Medtronic Freestyle: a single institution comparison of two stentless aortic valves.

BACKGROUND: Improved hemodynamics with the SPV and Freestyle bioprostheses compared to stented valves have been reported. It has been suggested that there is more aortic insufficiency (Al) with the Freestyle than with the SPV valve. This study was designed to assess the hemodynamic performance of these two valves implanted at a single institution with all echocardiograms reviewed by one echocardiographer. METHODS: From 1993 to 1997 112 patients underwent aortic valve replacement with stentless aortic valves (69 SPV, 43 Freestyle). There were no major preoperative differences in patient age, gender, NYHA class, or ejection fraction between groups. Echocardiographic assessment was obtained at discharge, 3 to 6 months following surgery, and yearly thereafter. RESULTS: Mean follow-up was 15.9 months for the SPV and 28.6 months for the Freestyle. Both valves have excellent valve areas and low transvalvar mean gradients. There is a trend for more Al in the SPV group. At 1 year, 1+ or greater Al was present in 11 of 42 SPV patients compared to 2 of 34 Freestyle patients (p = 0.030). Al has tended to remain stable over time, has not progressed, and is not clinically evident. DISCUSSION: Differences in the previously reported incidence of aortic insufficiency with these valves may have more to do with the method of reporting Al than its actual frequency. Within our institution, there has been slightly more mild Al with the SPV valve than with Freestyle. Long-term follow-up of these valves is needed to determine if the Al progresses or becomes clinically important. To date there is no such trend with either valve.

Adult↗

Monitoring of the extracranial and intracranial course of single emboli of cardiac origin: a preliminary report.

Simultaneous monitoring of emboli in extracranial and intracranial arteries recorded with identical probes, in a patient with an artificial cardiac valve, allowed the identification and characterization of pairs of signals, which most likely represent single emboli flowing through the common carotid artery into the middle cerebral artery. This technique offers new insight into emboligenesis with obvious therapeutic implications.

Carotid Artery Diseases↗

Using a modified subopaquing technique to treat highly discolored dentition.

BACKGROUND: The objective of esthetic dentistry is to treat diverse problems and achieve natural-appearing results. The author reviews the issues involved in the discoloration of human dentition and the concerns associated with current treatment for this problem. Understanding the proper use of materials in esthetic dentistry can result in a conservative, natural-appearing restoration. OVERVIEW: Dentition discoloration due to intrinsic staining can be a severe esthetic problem. Current treatment using crowns and highly opaque porcelain veneers has inherent disadvantages in regard to the final restorations. The author explores a subopaquing technique that allows for progressive lightening of highly stained teeth to create natural color depth in a conservative porcelain veneer procedure. CLINICAL IMPLICATIONS: In treating dental problems, the clinical practitioner looks for solutions that conserve tooth structure. To achieve natural-appearing esthetic results, it is important for the practitioner to be aware of technological advances in materials science as well as the proper use of esthetic dental techniques. Understanding the problems associated with dental discoloration and ways of correcting them will allow the practitioner to solve these moderate-to-severe esthetic problems on a consistent basis.

Adult↗