Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Polyethylene”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57Linked to original sources

Total luminescence intensity as a tool to classify degradable polyethylene films by early degradation detection and changes in activation energy.

Total luminescence intensity (TLI) was shown to be a valuable tool to monitor early degradation and thereby classify degradable polyethylene. The photo oxidation and thermal oxidation of polyethylene films containing different prooxidant systems were monitored. The chemiluminescence results were compared with results from FTIR, DSC, and SEC measurements. TLI gave an earlier detection of degradation and offered complementary information regarding changes in activation energies during the course of the degradation. TLI measurements were more sensitive to relative differences in degradation between the materials than the carbonyl index and crystallinity measurements, especially in the case of the UV-aged samples.

Calorimetry, Differential Scanning↗

Novel route to fatigue-resistant fully sintered ultrahigh molecular weight polyethylene for knee prosthesis.

The role of entanglements in obtaining a homogeneous product of ultrahigh molecular weight polyethylene (UHMW-PE) has been explored. Studies performed in this report show that a disentangled state before melting is a prerequisite to obtain homogeneous products of an intractable polymer like UHMW-PE. The disentangled state is obtained directly from the reactor by controlling the polymerization conditions or in the solid state when there is enhanced chain mobility along the c axis of a unit cell. The disentangled state is maintained in the melt over a period of time, invoking implications in polymer rheology. This approach is applicable to polymers in general. The homogeneous fully sintered UHMW-PE, obtained for the first time, shows a considerable decrease in oxygen permeability and an increase in toughness and fatigue resistance. Such homogeneous products of UHMW-PE are beneficial in highly demanding applications, especially in knee prosthesis, where the polymer is used as an inlay between the human bone and a metal or ceramic part, which slides against the polyethylene component during normal gait.

Knee Prosthesis↗

Effect of environmental conditions on the permeability of high density polyethylene film to fumigant vapors.

Soil fumigation in greenhouses or agricultural fields often includes tarping the soil surface with polyethylene (PE) films to contain the fumigant in the soil and reduce emissions to the atmosphere. Previous research has demonstrated that PE films are permeable to methyl bromide and other fumigant compounds. In these experiments, the effect of temperature, fumigant mixtures, condensed water, and field aging on the permeability of high-density polyethylene (HDPE) was determined. Mass transfer coefficients (h, a measure of permeability) of the fumigants methyl bromide, 1,3-dichloropropene, propargyl bromide, and chloropicrin across HDPE films were determined. In these studies, temperature and HDPE film type had the largest impact on the h of fumigant compounds across HDPE films. Other factors investigated, including fumigant mixtures, condensed water on the film, and field aging of UV-stabilized film, did not have a significant impact on h. The results of these experiments suggest that the permeability of an intact piece of an agricultural film will increase with increasing temperature but is relatively constant despite changes in other environmental conditions.

Fumigation↗

Stabilization of oil-in-water emulsions by beta-lactoglobulin-polyethylene glycol conjugates.

The disulfide bonds of beta-lactoglobulin (beta-lg) were modified by oxidative sulfitolysis to generate beta-lgSO(3). The native protein (beta-lg) and the modified protein (beta-lgSO(3)) were conjugated to activated polyethylene glycol (PEG) to generate beta-lgPEG and beta-lgSO(3)PEG, respectively. Oil-in-water (o/w) emulsions containing 1% beta-lg or beta-lg conjugates were prepared at pH 2.8, 5.0, and 7.0. Emulsion droplet diameters and zeta potentials were measured. For the same emulsifier, emulsion droplet diameters decreased when emulsion pH increased. Zeta potentials of emulsion droplets increased with pH for beta-lg and beta-lgSO(3). Zeta potentials of beta-lgPEG and beta-lgSO(3)PEG approached zero, suggesting that the protein molecule was covered by PEG chains. Accelerated and 7-day storage stabilities at 21 degrees C of the emulsions were monitored. The emulsifying activity index (EAI) of beta-lgPEG was not significantly different from the EAI of beta-lg. The EAI of beta-lg was enhanced following sulfitolysis of beta-lactoglobulin. The emulsifying activity increased more when the oxidatively modified protein was conjugated to polyethylene glycol. Emulsions made with beta-lgSO(3)PEG were more stable than emulsions made with beta-lg, beta-lgPEG, or beta-lgSO(3) under accelerated stability study and for 7 days at 21 degrees C. The stability of o/w emulsions stabilized with beta-lgSO(3)PEG increased because individual droplets were better protected, against protein bridging or coalescence, by the thick adsorbed protein-PEG layer.

Drug Stability↗

Interactions between aroma and edible films. 1. Permeability Of methylcellulose and low-density polyethylene films to methyl ketones.

This work contributes to the study of aroma transfers through edible and plastic packaging films. Permeability, sorption, and diffusivity of three methyl ketones (2-heptanone, 2-octanone, and 2-nonanone) in and through low-density polyethylene and methylcellulose-based edible films have been determined. Permeability was measured using a dynamic method coupled with a gas chromatograph. The methyl ketone permeability of polyethylene films mainly depends on diffusivity of the penetrant in the polymer. In the case of 2-heptanone, a saturation of the polymer network is observed at high vapor concentrations. The formation of clusters could take place when concentrations are higher in the vapor phase. Physicochemical interactions between aroma compounds and components of the methylcellulose-based film induce structural changes such as plasticization. Therefore, the diffusion step depends on the aroma concentration differential, and permeability is essentially driven by the sorption.

Ketones↗

Partial dewetting of polyethylene thin films on rough silicon dioxide surfaces.

The effect of roughness on the dewetting behavior of polyethylene thin films on silicon dioxide substrates is presented. Smooth and rough silicon dioxide substrates of 0.3 and 3.2-3.9 nm root-mean-square roughness were prepared by thermal oxidation of silicon wafers and plasma-enhanced chemical vapor deposition on silicon wafers, respectively. Polymer thin films of approximately 80 nm thickness were deposited by spin-coating on these substrates. Subsequent dewetting and crystallization of the polyethylene were observed by hot-stage optical microscopy in reflection mode. During heating, the polymer films melt and dewet on both substrates. Further observations after cooling indicate that, whereas complete dewetting occurs on the smooth substrate surface, partial dewetting occurs for the polymer film on the rough surface. The average thickness of the residual film on the rough surface was determined by ellipsometry to be a few nanometers, and the spatial distribution of the polymer in the cavities of the rough surface could be obtained by X-ray reflectometry. The residual film originates from the impregnation of the porous surface by the polymer fluid, leading to the observed partial dewetting behavior. This new type of partial dewetting should have important practical consequences, as most real surfaces exhibit significant roughness.

Crystallization↗

Direct catalytic route to superhydrophobic polyethylene films.

Polyethylene films grow on a flat silica surface modified by the bis(imino)pyridyl iron(II) catalyst during ethylene polymerization in toluene solvent. The resulting films show superhydrophobic properties. Advancing water contact angle as high as 169 degrees and sliding angles as low as 2 degrees are obtained on these films. SEM images reveal special surface structures of these films containing micrometer-sized islands, submicrometer particles on the islands, and stress nanofibers between the islands, which render superhydrophobicity to the polyethylene surfaces. After the submicrometer particles and stress nanofibers are removed by annealing, the superhydrophobic properties of the polymer films disappear.

Catalysis↗

Functionalized hyperbranched polyethylene powder supports.

[reaction: see text] Polyethylene powders with useful loadings of functional groups are accessible by hyperbranched grafting chemistry. Using a 200 microm diameter high-density powder, loadings of up to 0.4 mmol/g of CO(2)H groups are attained. The carboxylic acid groups in the resulting powders can be further functionalized covalently or ionically and resulting powders have the physical durability and solvent resistance associated with polyethylene itself.

Alcohols↗

Compression shear strength and tableting behavior of microcrystalline cellulose agglomerates modulated by a solution binder (polyethylene glycol).

PURPOSE: To investigate the possibility of modulating the compression shear strength of agglomerates by the incorporation of a solution binder and to study the subsequent effect on the deformation behavior and tablet forming ability of the agglomerates. METHOD: Various concentrations (0.5 to 10%) of polyethylene glycol were incorporated as a solution binder into microcrystalline cellulose agglomerates of different porosity (10 and 20%) and the shear strength of the agglomerates, as evaluated by the 1/b value of the Kawakita equation, and the permeability to air and tensile strength of tablets formed from them were determined. RESULTS: Increased agglomerate porosity and concentration of polyethylene glycol reduced the 1/b values, which led to the formation of tablets with a lower permeability. A decreased tablet permeability corresponded to an increased tablet tensile strength except that the highest binder content was associated with a drop in the tablet tensile strength. CONCLUSIONS: The solution binder reduced the agglomerate shear strength, which was expressed as an increased degree of agglomerate deformation during compression. The latter seemed to be controlled by both agglomerate porosity and shear strength. The main role of the solution binder in improving the agglomerate compactability was to increase the degree of deformation of agglomerates during compression.

Cellulose↗

In vitro human epidermal and polyethylene membrane penetration and retention of the sunscreen benzophenone-3 from a range of solvents.

PURPOSE: To study epidermal and polyethylene membrane penetration and retention of the sunscreen benzophenone-3 (BP) from a range of single solvent vehicles and evaluate solvent effects on permeability parameters. METHODS: The solubility of BP was measured in a number of solvents. Penetration of BP across human epidermis and high density polyethylene (HDPE) membranes was studied from 50% saturated solutions in each solvent. RESULTS: Maximal BP fluxes from the solvents across the two membranes varied widely. Highest fluxes were observed from 90% ethanol (EtOH) for epidermis and from isopropyl myristate (IPM) and C12-15 benzoate alcohols (C12-15 BA) for HDPE membrane. Both the flux and estimated permeability coefficient and skin-vehicle partitioning of BP appeared to be related to the vehicle solubility parameter (delta(v)). The major effects of solvents on BP flux appear to be via changes in BP diffusivity through the membranes. CONCLUSIONS: Minimal penetration of sunscreens such as BP is best achieved by choosing vehicles with a delta(v) substantially different to the solubility parameter of the membrane.

Administration, Topical↗

The effect of partially stabilized zirconia on the mechanical properties of the hydroxyapatite-polyethylene composites.

The effect of partially stabilized zirconia (PSZ) on the mechanical properties of the hydroxyapatite-high density polyethylene composites was studied by investigating the effect of hydroxyapatite and the simultaneous effect of hydroxyapatite and PSZ volume fractions on fracture strength, modulus of elasticity, and absorbed energy in the composite samples. The results showed a decrease in fracture strength, and absorbed energy with an increase in the volume fraction of hydroxyapatite content in the hydroxyapatite-polyethylene samples. Partial replacement of hydroxyapatite with PSZ particles was beneficial in the improvement of both the fracture strength and failure energy values in the composite samples. A transition from ductile to brittle behavior was observed as the volume fraction of ceramic filler particles increased in the samples.

Bone Substitutes↗

Naphthalene contamination of sterilized milk drinks contained in low-density polyethylene bottles. Part 1.

Naphthalene contamination was observed in sterilized milk drinks contained in low-density polyethylene bottles. The determination of naphthalene in the packaging material by gas chromatography showed levels of naphthalene ranging from 0.7 to 2.0 micrograms g-1. Analysis of the milk samples at the time of purchase by gas chromatography after extraction using a Dean and Stark apparatus showed levels of naphthalene in the range 0.01-0.03 microgram ml-1. The level of contamination in milk increased with storage time at room temperature (25 degrees C) and, depending on the concentration of naphthalene in the packaging material, values of 0.08-0.27 microgram ml-1 were found at the expiry date. Migration studies were carried out using peanut oil as a food stimulant. The amount of naphthalene extracted by milk from the polyethylene at 25 degrees C over a period of 60 d was related to the amount that could be extracted using peanut oil at 66 degrees C for 30 h. A mathematical model was established to describe the observed migration of naphthalene into milk, and proved valid for calculating the level of naphthalene in milk using the optimum determined values of K and Dp.

Animals↗

Comparison of efficacy and safety of two doses of two different polyethylene glycol-based laxatives in the treatment of constipation.

AIM: To compare standard and maximum daily doses of polyethylene glycol 3350 plus electrolytes (Transipeg) and polyethylene glycol 4000 (Forlax) in a multicentre, double-blind, randomized, parallel-group study. METHODS: Ambulatory patients with idiopathic chronic constipation were randomized to receive Forlax (10 or 20 g) or Transipeg (5.9 or 11.8 g) for 1 month. The primary efficacy end-point was stool frequency. Secondary efficacy parameters included stool consistency, date of occurrence of first motion, straining on defecation, rectal evacuation, abdominal pain and distension. Adverse events were recorded. RESULTS: Stool frequency was significantly increased compared with baseline in all treatment groups (P = 0.0001). Most patients (> or = 67.3%) had their first stool within 1 day of starting treatment. Stool consistency significantly improved compared with baseline in all treatment groups (P = 0.0001). The percentage of patients with normal stool consistency was significantly higher for standard-dose Transipeg vs. both maximum-dose treatments (P < 0.01). Other secondary parameters were also significantly improved compared with baseline in all treatment groups (P = 0.0001). All medications were well tolerated. CONCLUSIONS: Standard-dose Transipeg (5.9 g) normalized stool consistency with less semi-liquid or liquid stools than maximum-dose Transipeg and Forlax, with a non-significant trend towards less semi-liquid or liquid stools than standard-dose Forlax.

Adult↗

Factors affecting cardiolipin antibody assays: modification with polyethylene glycol compound.

Anti-cardiolipin antibody (aCL) measurement is only semi-reproducible, and current assays detect irrelevant as well as clinically significant antibodies. Factors found to influence results included the source of the enzyme-linked immunoabsorbent assay (ELISA) plate, and its pretreatment with solvents; the nature of the blocking solution; and the composition of the diluent used for reagents. Fetal calf serum (FCS) in the diluent appeared to reduce nonspecific (clinically irrelevant) binding and was not simply a source of beta2-glycoprotein-1 (beta2GP1). A polyethylene glycol compound was found to be an effective blocking agent, and its use enhanced the discrimination between positive and negative samples. A high level of variation may be inherent in aCL-ELISA methodology, but the use of polyethylene glycol compound appeared to be a helpful modification.

Antibodies, Anticardiolipin↗

Disintegration of porous polyethylene prostheses.

A Plastipore (porous polyethylene) Total Ossicular Replacement Prosthesis gave an excellent initial hearing result which was maintained for 14 years. Hearing then began to deteriorate and revision surgery showed disintegration of the prosthesis and a defect in the stapes footplate. Histological examination confirmed previous findings in porous polyethylene with multinucleated foreign body giant cells and breakdown of the material.

Adult↗

Platelet adhesion, contact phase coagulation activation, and C5a generation of polyethylene glycol acid-grafted high flux cellulosic membrane with varieties of grafting amounts.

Grafting of polyethylene glycol chains onto cellulosic membrane can be expected to reduce the interaction between blood (plasma protein and cells) and the membrane surface. Alkylether carboxylic acid (PEG acid) grafted high flux cellulosic membranes for hemodialysis, in which the polyethylene glycol chain bears an alkyl group at one side and a carboxyl group at the other side, have been developed and evaluated. PEG acid-grafted high flux cellulosic membranes with various grafting amounts have been compared with respect to platelet adhesion, the contact phase of blood coagulation, and complement activation in vitro. A new method of quantitating platelet adhesion on hollow-fiber membrane surfaces has been developed, which is based on the determination of lactate dehydrogenase (LDH) activity after lysis of the adhered platelets. PEG acid-grafted high flux cellulosic membranes showed reduced platelet adhesion and complement activation effects in grafting amounts of 200 ppm or higher without detecting adverse effects up to grafting amounts of 850 ppm. The platelet adhesion of a PEG acid-grafted cellulosic membrane depends on both the flux and grafting amounts of the membrane. It is concluded that the grafting of PEG acid onto a cellulosic membrane improves its biocompatibility as evaluated in terms of platelet adhesion, complement activation, and thrombogenicity.

Animals↗

A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award.

Increasing cross-linking has been shown in vitro and in vivo to improve markedly the wear resistance of ultra-high-molecular-weight polyethylene (UHMWPE). The reduction in the mechanical properties of polyethylene under certain methods used to produce cross-linking has been a concern, however. These reductions are known to result from the processes used to increase the cross-link density and could affect the device performance in vivo. We present a novel method of increasing the cross-link density of UHMWPE in which UHMWPE is irradiated in air at an elevated temperature with a high-dose-rate electron beam and subsequently is melt-annealed. This treatment improves markedly the wear resistance of the polymer as tested in a hip simulator, while maintaining the mechanical properties of the material within national and international standards. This method leads to the absence of detectable free radicals in the polymer and, as a result, excellent resistance to oxidation of the polymer.

Biocompatible Materials↗

A simple technique to remove well-fixed, all-polyethylene cemented acetabular component in revision hip arthroplasty.

Well-fixed, all-polyethylene acetabular components may have to be removed in cases of recurrent dislocations, infection, or fracture of ceramic femoral heads. We describe a simple technique using acetabular reamers that allow cup thinning. Through this technique, the polyethylene rigidity is diminished considerably, allowing its easy removal without any risk of fracture, particularly of the acetabulum walls.

Arthroplasty, Replacement, Hip↗