Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Motion”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57Linked to original sources

Binding of motion and colour is early and automatic.

At what stages of the human visual hierarchy different features are bound together, and whether this binding requires attention, is still highly debated. We used a colour-contingent motion after-effect (CCMAE) to study the binding of colour and motion signals. The logic of our approach was as follows: if CCMAEs can be evoked by targeted adaptation of early motion processing stages, without allowing for feedback from higher motion integration stages, then this would support our hypothesis that colour and motion are bound automatically on the basis of spatiotemporally local information. Our results show for the first time that CCMAE's can be evoked by adaptation to a locally paired opposite-motion dot display, a stimulus that, importantly, is known to trigger direction-specific responses in the primary visual cortex yet results in strong inhibition of the directional responses in area MT of macaques as well as in area MT+ in humans and, indeed, is perceived only as motionless flicker. The magnitude of the CCMAE in the locally paired condition was not significantly different from control conditions where the different directions were spatiotemporally separated (i.e. not locally paired) and therefore perceived as two moving fields. These findings provide evidence that adaptation at an early, local motion stage, and only adaptation at this stage, underlies this CCMAE, which in turn implies that spatiotemporally coincident colour and motion signals are bound automatically, most probably as early as cortical area V1, even when the association between colour and motion is perceptually inaccessible.

Afterimage↗

The contribution of otoliths and semicircular canals to the perception of two-dimensional passive whole-body motion in humans.

1. Perception of two-dimensional (2-D) whole-body passive motion in the horizontal plane was studied in twelve blindfolded healthy volunteers: pure rotation in place (180 deg), linear motion (4.5 m) and a semicircular trajectory (radius, 1.5 m; angular acceleration, 0.2 rad s-2) were applied in random sequence by means of a remote-controlled robot equipped with a racing-car seat. The seat orientation in the horizontal plane was controlled by the experimenter, independent of the robot trajectory. Thus different degrees of otolith-canal interaction were obtained. The maximal linear acceleration during the semicircular trajectory was 0.1 g; however, the linear acceleration vector was complex as it rotated relative to the subject's head. 2. In the first of two sessions, subjects were instructed to maintain an angular pointer oriented towards a remote (15 m) previously seen target during the passive movements. In the second session they had to make a drawing of the path of the perceived trajectory, after the movement was finished. 3. The results showed that, on average, the movement of the pointer matched the dynamics of the rotatory component of the 2-D motion well. This suggests that, in the range of linear accelerations used in this study, no appreciable influence of otolith input on canal-mediated perception of angular motion occurred. 4. The curvature of the drawn paths was mostly explained by the input to the semicircular canals. Subjects' reconstruction of motion did not account for the directional dynamics of the input to the otoliths occurring during passive motion. 5. This finding proves that reconstructing trajectory in space does not imply a mathematically perfect transformation of the linear and angular motion-related inputs into a Cartesian or polar 2-D representation. Physiological constraints on the interaction between motion direction and change of heading play an important role in motion perception.

Acceleration↗

Motion sickness severity and physiological correlates during repeated exposures to a rotating optokinetic drum.

Fifty-two subjects were exposed to a rotating optokinetic drum. Ten of these subjects who became motion sick during the first session completed two additional sessions. Subjects' symptoms of motion sickness, perception of self-motion, electrogastrograms (EGGs), heart rate, mean successive differences of R-R intervals (RRI), and skin conductance were recorded for each session. The results from the first session indicated that the development of motion sickness was accompanied by increased EGG 4-9 cpm activity (gastric tachyarrhythmia), decreased mean successive differences of RRI, increased skin conductance levels, and increased self-motion perception. The results from the subjects who had three repeated sessions showed that 4-9 cpm EGG activity, skin conductance levels, perception of self-motion, and symptoms of motion sickness all increased significantly during the drum rotation period of the first session, but increased significantly less during the following sessions. Mean successive differences of RRI decreased significantly during the drum rotation period for the first session, but decreased significantly less during the following sessions. In conclusion, we have demonstrated that the development of motion sickness is accompanied by an increase in gastric tachyarrhythmia, and an increase in sympathetic activity and a decrease in parasympathetic activity, and that adaptation to motion sickness is accompanied by the recovery of autonomic nervous system balance.

Adaptation, Physiological↗

Continuous passive motion after total knee arthroplasty. Analysis of cost and benefits.

The authors report the results of a prospective study examining the benefits of daily continuous passive motion combined with physical therapy, compared with physical therapy alone, in 103 consecutive osteoarthritic patients undergoing primary total knee arthroplasty. The first 51 patients received continuous passive motion initiated in the recovery room and the next 52 patients did not receive continuous passive motion. Both groups underwent an identical physical therapy protocol starting on the first postoperative day. At discharge, there was a significant increase in active flexion in the continuous passive motion group. There were no significant differences regarding pain, wound healing, knee swelling, wound drainage, pulmonary embolism, or length of hospital stay between the 2 groups. At 2 years, there were no clinical differences in the motion or knee scores. Knee manipulation was done for < 50 degrees flexion after the tenth postoperative day. There were 5 manipulations in the noncontinuous passive motion group and none in the continuous passive motion group. The entire costs associated with the 5 manipulations was $48,274 or $937 per patient not receiving continuous passive motion. The average daily inpatient rental of the machine was $60 per day. Continuous passive motion is efficacious in increasing short-term flexion and decreasing the need for knee manipulation without increasing costs.

Aged↗

Motion automated perimetry identifies early glaucomatous field defects.

OBJECTIVE: To determine if motion automated perimetry can identify early glaucomatous visual field defects in patients with suspected glaucoma (by disc), those with ocular hypertension, and those with primary open-angle glaucoma. METHODS: Motion automated perimetry, a foveally centered motion test, and standard visual field tests were conducted on one randomly selected eye of normal patients (n = 38), patients with suspected glaucoma (by disc) (n = 28), patients with ocular hypertension (n = 18), and patients with primary open-angle glaucoma (n = 21). Subjects' performance on both motion tests were compared with their performance on standard perimetry. RESULTS: Perimetric motion thresholds significantly distinguished the groups (P< or =.001), while the foveally centered motion test was unable to separate them (P< or =.32). Of the total patients, 90.5% of those with glaucoma, 39.3% of those with suspected glaucoma, 27.8% of those with ocular hypertension, and 5.3% of the normal subjects had abnormal results on motion automated perimetry testing. Perimetric motion thresholds were significantly correlated with standard visual field thresholds (P< or =.001). CONCLUSION: Motion automated perimetry identifies visual field defects in patients who already show standard visual field loss as well as in a moderate percentage of those with suspected glaucoma and ocular hypertension, indicating that the testing of discrete locations might be necessary for increased diagnostic utility.

Aged↗

The role of second-order motion signals in coherence and transparency.

Second-order or non-Fourier motion was originally demonstrated in the laboratory by the use of contrast-modulated stimuli of various types. As these stimuli seem somewhat artificial, it might be questioned whether they play a significant role in the processing of natural motion. An affirmative answer is provided by the key observation that the non-Fourier motion apparatus analyses the motion of texture boundaries in two-dimensional patterns. Given this, a wide range of motion phenomena can be explained by a neural model that combines both Fourier and non-Fourier motion signals in a neural network that computes the vector sum direction. The existence of a vector sum computation is supported by two observations: patterns composed of two cosine gratings ('plaids') appear to move in the vector sum direction during brief presentations and plaids composed solely of non-Fourier components always move in the vector sum direction. The neural model predicts these results and also agrees with much of area MT physiology. Within this context, many instances of motion transparency result when the angle between Fourier motion directions is large (> 90 degrees) and the non-Fourier motion signal is minimal or absent.

Animals↗

Direct monitoring of coronary artery motion with cardiac fat navigator echoes.

Navigator echoes (NAVs) provide an effective means of monitoring physiological motion in magnetic resonance imaging (MRI). Motion artifacts can be suppressed by adjusting the data acquisition accordingly. The standard pencil-beam NAV has been used to detect diaphragm motion; however, it does not monitor cardiac motion effectively. Here we report a navigator approach that directly measures coronary artery motion by exciting the surrounding epicardial fat and sampling the signal with a k-space trajectory sensitized to various motion parameters. The present preliminary human study demonstrates that superior-inferior (SI) respiratory motion of the coronary arteries detected by the cardiac fat NAV highly correlates with SI diaphragmatic motion detected by the pencil-beam NAV. In addition, the cardiac fat navigator gating is slightly more effective than the diaphragmatic navigator gating in suppressing motion artifacts in free-breathing 3D coronary MR angiography (MRA).

Adipose Tissue↗

Crystallographic dissection of the thermal motion of protein-sugar complex.

The crystal structure of turkey egg lysozyme (TEL) complexed with di-N-acetylchitobiose (NAG2) was refined at 1.19 A resolution by the full-matrix least-squares method with anisotropic temperature factors, and its thermal motion was evaluated by the TLS method. The average ESDs of atomic parameters of nonhydrogen atoms were 0.030 A for coordinates and 0.025 A(2) for anisotropic temperature factors. The active site cleft of TEL binds the alpha-anomer of NAG2 in a nonproductive binding mode with its pyranose rings parallel to a beta-sheet. The TEL structure was compared with the re-refined 1.12 A structure of native TEL. The RMS difference for equivalent Calpha atoms was 0.103 A and a relatively large difference was observed in the region of residues 104-125 rather than in the beta-sheet region where NAG2 was bound. In contrast, the temperature factor of the beta-sheet region was significantly decreased by the NAG2 binding. The TLS model that describes the rigid body motion in translation, libration, and screw motion was adopted for the evaluation of the molecular motion of TEL and NAG2, and the TLS parameters were determined by the least-squares fit to U(ij). The contribution of the external motion of TEL was estimated to be 55.8% of the observed temperature factor for the native structure and 45.9% for the NAG2 complex. The internal motion of TEL represented with atomic thermal ellipsoids was very similar between the native and complex structures except the NAG2 binding region. In the structure of NAG2, the rigid body motion dominates the thermal motion. The center of rotation of NAG2, 4.45A far from the center of gravity, is on the nitrogen atom of the acetylamino group that is hydrogen bonded to the main-chain peptide groups of Asn49 and Ala107. The rigid body motion of NAG2 indicates that the acetylamino group is most strongly bound to the active site, and the recognition of this group is a crucial step of the substrate binding.

Animals↗

Domain closure in lactoferrin. Two hinges produce a see-saw motion between alternative close-packed interfaces.

Lactoferrin is an iron transport protein. Upon binding iron, the two domains in the N-terminal half of the molecule move together. Previous work has shown that this domain closure involves two hinges. Using the newly refined structure of the open form, the structural mechanism underlying this motion is analyzed here in detail. Upon closure the domains rotate 54 degrees essentially as rigid bodies. The axis of rotation passes through the two beta-strands linking the domains. These strands contain hinges in the sense that three large torsion angle changes are responsible for the bulk of the motion while smaller torsion angle changes in neighboring residues are responsible for the remainder of the motion. The rotation axes of these three torsion angle changes are nearly parallel to the axis of the overall 54 degrees rotation, so the local motion in the hinges can be directly related to the overall motion. A crucial feature of the hinge residues is that they have very few packing constraints on their main-chain atoms. The domains make different packing contacts with each other in the open and closed forms. These contacts form two interdomain interfaces arranged on either side of the hinges. Pivoting about the hinges produces a see-saw motion between the two interfaces. That is, when the domains close down, residues in the interface on one side of the hinges become buried and close-packed and residues on the other side become exposed. The situation is reversed when the domains open up. Lactoferrin provides a particularly clear example of the general features of hinged domain motion. It is compared to other instances of hinged domain closure and contrasted with instances of shear domain closure, where the overall motion is a summation of many small sliding motions between close-packed segments of polypeptide.

Amino Acid Sequence↗

Motion and ballistocardiogram artifact removal for interleaved recording of EEG and EPs during MRI.

Artifacts generated by motion (e.g., ballistocardiac) of the head inside a high magnetic field corrupt recordings of EEG and EPs. This paper introduces a method for motion artifact cancellation. This method is based on adaptive filtering and takes advantage of piezoelectric motion sensor information to estimate the motion artifact noise. This filter estimates the mapping between motion sensor and EEG space, subtracting the motion-related noise from the raw EEG signal. Due to possible subject motion and changes in electrode impedance, a time-varying mapping of the motion versus EEG is required. We show that this filter is capable of removing both ballistocardiogram and gross motion artifacts, restoring EEG alpha waves (8-13 Hz), and visual evoked potentials (VEPs). This adaptive filter outperforms the simple band-pass filter for alpha detection because it is also capable of reducing noise within the frequency band of interest. In addition, this filter also removes the transient responses normally visible in the EEG window after echo planar image acquisition, observed during interleaved EEG/fMRI recordings. Our adaptive filter approach can be implemented in real-time to allow for continuous monitoring of EEG and fMRI during clinical and cognitive studies.

Adult↗

The interpretation of biological motion.

The term biological motion has been coined by Johansson (1973) to refer to the ambulatory patterns of terrestrial bipeds and quadripeds. In this paper a computational theory of the visual perception of biological motion is proposed. The specific problem addressed is how the three-dimensional structure and motions of animal limbs may be computed from the two dimensional motions of their projected images. It is noted that the limbs of animals typically do not move arbitrarily during ambulation. Rather, for anatomical reasons, they typically move in single planes for extended periods of time. This simple anatomical constraint is exploited as the basis for utilizing a "planarity assumption" in the interpretation of biological motion. The analysis proposed is: (1) divide the image into groups of two or three elements each; (2) test each group for pairwise-rigid planar motion; (3) combine the results from (2). Fundamental to the analysis are two "structure from planar motion" propositions. The first states that the structure and motion of two points rigidly linked and rotating in a plane is recoverable from three orthographic projections. The second states that the structure and motion of three points forming two hinged rods constrained to move in a plane is recoverable from two orthographic projections. The psychological relevance of the analysis and possible interactions with top down recognition processes are discussed.

Gait↗

The Simon effect and visual motion.

S-R compatibility and Simon effects were studied for real visual motion. In Experiment 1, two small stimulus lights were constantly visible, 5 degrees to the left and right of fixation; after a random delay, one began to move at 2 degrees/s. In Experiment 2, a single stimulus light moving at 2 degrees/s suddenly appeared 5 degrees to the left or right of fixation, i.e., motion onset and stimulus onset coincided. In both experiments, subjects responded by a key press with their left or right index finger as soon as they detected motion. In Condition A responses were made to the position (left or right) from which the motion started, irrespective of its direction (position compatibility); in Condition B responses were made to the direction of motion (leftward or rightward) irrespective of whether motion started to the left or to the right of fixation (direction compatibility). The results show strong compatibility effects for both position and direction of motion in both experiments. A Simon effect, however, occurred only when position was task irrelevant in Experiment 1; no Simon effect was found in Experiment 2. The data only partly confirm previous results obtained with apparent motion. The selective lack of a Simon effect supports the integrated model of Umiltà and Nicoletti (1992), which requires orienting of attention for the Simon effect to occur. It is specifically assumed that this attention-orienting is triggered only by the saccade program and does not extend to the pursuit program that is initiated by smooth stimulus motion.

Adolescent↗

The effect of motion on pattern-onset visual evoked potentials in adults and children.

Visual evoked potentials can be elicited by a variety of visual stimuli, including pattern-onset and motion-onset. It may be desirable to combine pattern-onset with motion-onset stimuli, for example, to make a direct comparison between optokinetic nystagmus and visual evoked potential acuity thresholds. Both procedures employ grating stimuli; however, the gratings must be moving to produce optokinetic nystagmus. We compared pattern-onset visual evoked potentials with both a static and a moving pattern to investigate the effect of motion on the pattern-onset visual evoked potential waveform. Visual evoked potential recordings were made from 10 adults (aged 20-37 years) and 10 children (aged 5-7 years) with the active electrode at Oz. Stimuli consisted of onset of high-contrast vertical bars of three sizes (12', 30' and 60') both with and without motion (3 cycles/s). In a subgroup of subjects, visual evoked potentials were recorded to motion onset of constantly present gratings. Motion of the pattern had no significant effect on any of the latency components of the visual evoked potential waveform in adults or children. The amplitude of the C2-C3 component was significantly increased (p < 0.001) in adults. The motion appears to add a late negative component to the visual evoked potential similar to that produced by the motion-only stimulus. The latency of the early components of the pattern-onset visual evoked potential was unaffected by the presence of motion. Therefore, pattern-onset visual evoked potentials with moving gratings could be used to estimate visual acuity, and direct comparisons could be made between visual evoked potential and optokinetic nystagmus acuity thresholds with the use of the same stimulus parameters.

Adult↗

A coordinate system for visual motion perception.

The purpose of this research was to determine the reference axes used by the visual system to specify direction of motion of objects by the visual system at the perceptual level. Ten young adults aligned motion of a moving luminous dot on a computer display to body-fixed and external vertical and horizontal plane axes while operating in a dark room. Accuracy of aligning dot motion to earth-fixed vertical, a displayed luminous line (external visual axis) of varied orientations, and head and trunk longitudinal axes was tested in one experiment with the display in the vertical frontal plane. In a second experiment, dot motion was aligned to head and trunk anterior/posterior (A-P) axes and to an external visual axis presented on a horizontal computer screen. Head and trunk orientations were varied in the frontal plane (left/right tilt) when testing vertical plane axes and by rotation of the head and/or trunk about a vertical axis when testing horizontal plane axes. Perceptual errors were lowest when aligning to earth-fixed vertical in the vertical plane and to an external oblique line in the horizontal plane when head and trunk orientations were varied. Perceptions of horizontal plane motion direction were accurate relative to the trunk-fixed A-P axis when only head orientation was varied, but large errors were made when trunk orientation was varied. Proprioceptive influences on visual perceptions of motion direction were shown by a dependence of perceptual errors on trunk and neck orientations when aligning to all axes. Furthermore, when aligning motion to an external line, the errors depended on orientation of the line in addition to trunk and neck orientations, but not when aligning to intrinsic axes or earth-fixed vertical in the presence of an external line. We conclude that the visual motion system defines direction relative to earth-fixed vertical and an external horizontal reference axis when available. The trunk-fixed A-P axis can be used to accurately define motion direction when operating without an external reference if a neutral trunk orientation is maintained.

Adult↗

Factors influencing the susceptibility of anurans to motion sickness.

We examined the propensity for motion sickness in five anuran species, concentrating our efforts on the treefrog Rhacophorus schlegelii, because it had shown the greatest susceptibility to motion sickness in a previous study. We used parabolic flight as our provocative stimulus and fed all specimens a known volume of food 1.5-3 h before flight. The presence of vomitus in a frog's cage was our indicator of motion sickness. Significantly more emesis was observed in flight-exposed than in control R. schlegelii (P < 0.05). There was no sex difference in susceptibility to motion sickness (P > 0.5). Individuals that vomited were significantly larger (P < 0.02) than those that did not. Among microgravity-treated frogs, those that vomited spent on average 85% more time airborne and tumbling in microgravity than those that did not vomit (P=0.031). Our data support the view that postural instability and sensory conflict are elements of motion sickness in anurans. Specifically, conflicts between tactile, vestibular and visual input seem essential for producing motion-induced emesis in anurans. Since the factors that induce motion sickness in R. schlegelii are the same ones that produce motion sickness in humans, arboreal frogs may be useful alternative models to mammals in motion sickness research.

Animals↗

Cervical range of motion in the elderly.

This study was conducted to establish normative cervical range of motion values for the elderly and to compare those values to standard young adult cervical range of motion values. Differences in range of motion between men and women were also assessed. A gravity goniometer was used to measure six cervical motions in 42 subjects aged 70 to 90 years and 31 subjects aged 20 to 30 years. The elderly group had significantly less motion than the younger group for all six motions measured (p < .001). A comparison of the mean range of motion values between the two groups found that the elderly group had approximately 12% less flexion, 32% less extension, 22% less lateral flexion, and 25% less rotation. The elderly group also had a wider variation of cervical range of motion values as compared to the younger group. Women had greater cervical range of motion values than men in both age groups.

Adult↗

A computer-based biomechanical analysis of the three-dimensional motion of cementless hip prostheses.

A computer-based mathematical technique was developed to measure and completely describe the migration and micromotion of a femoral hip prosthesis relative to the femur. This technique utilized the mechanics of rigid-body motion analysis and apparatus of seven linear displacement transducers to measure and describe the complete three-dimensional motion of the prosthesis during cyclic loading. Computer acquisition of the data and custom analysis software allowed one to calculate the magnitude and direction of the motion of any point of interest on the prostheses from information about the motion of two points on the device. The data were also used to replay the tests using a computer animation technique, which allowed a magnified view of the three-dimensional motion of the prosthesis. This paper describes the mathematical development of the rigid-body motion analysis, the experimental method and apparatus for data collection, the technique used to animate the motion, the sources of error and the effect of the assumptions (rigid bodies) on the results. Selected results of individual test runs of uncemented and cemented prostheses are presented to demonstrate the efficacy of the method. The combined effect of the vibration and electrical noise resulted in a resolution of the system of about 3-5 microns motion for each transducer. Deformation effects appear to contribute about 3-15 microns to the measurement error. This measurement and analysis technique is a very sensitive and powerful means of assessing the effects of different design parameters on the migration and micromotion of total joint prostheses and can be applied to any other case (knee, dental implant) where three-dimensional relative motion between two bodies is important.

Biomechanical Phenomena↗

Cerebrospinal fluid constituents of cat vary with susceptibility to motion sickness.

Six female cats, varying in susceptibility to motion sickness, were implanted with chronic cannulae in the rostral portion of the fourth ventricle. The cats were then challenged with a motion sickness-inducing stimulus. Samples of cerebrospinal fluid were withdrawn before and after emesis or 30 min of motion if emesis did not occur and again on control (no motion) days. The samples were analyzed by HPLC with an array of 16 coulometric detectors. Thirty-six compounds were identified in the samples. Baseline levels of DOPAC, MHPGSO4, uric acid, DA, 5-HIAA and HVA were lower on motion and control days in cats which became motion sick when compared with cats which did not become motion sick. None of the identified compounds varied as a function of either exposure to motion or provocation of emesis. It is concluded that susceptibility to motion sickness is a manifestation of individual differences related to fundamental neurochemical composition.

Animals↗