[Resection of the knee reconstructed with a massive prosthesis. Results after a 5 to 9 years follow-up].

Since ten years, with the progress of the adjuvant chemotherapy we treated conservatively 170 osteosarcomas. We try to review the functional and mechanical results of the knee prosthesis with 5 years of follow-up or more. There were 64 resections, 51 of the lower femur and 13 of the upper tibia. The early postoperative complications are few (less than 2%). The functional results are satisfying with 90% of excellent and good results. We observed 3 local recurrences (2 femur, 1 tibia). The survey is really increased by the adjuvant chemotherapy with a rate of 70% at 5 years. However for us the problem is the evolution of our reconstitution prosthesis. 3 kinds of mechanical failures occurred: a wear of the hinge, a fracture of the stem and a loosening of the massive component. The Guepar hinge was finally a good solution when it was metallic, but all the hinges with metal plastic. Articulation needed reinterventions because of quick wearing. For the tibial reconstitution prosthesis we did not observed any problem but for the femoral massive prosthesis, the failures were more frequent, perhaps because the mechanical situation is different. We observed 4 fractures of the stem, 5 loosening of femoral stem (bipolar loosening in one case). In all except one, the reintervention gave a good result. Finally, the result seems to be encouraging, the progress of the implant (Titanium stem, modular prosthesis, semi-constrained knee) may again decrease the rate of mechanical failures.

Adolescent↗

[Indications of prosthesis in the treatment of knee diseases].

Hinge prostheses of the knee expose to so many local or even systemic complications that they should be used only for reconstruction of the knee after tumoral excision. In all other indications, prosthesis of the knee must be semi-constrained or non-constrained. Moreover, it seems that it would be useful to choose the prosthesis that preserves the ligaments to the best, in order to reduce as much as possible the stress imposed on bone/prosthesis interfaces and to limit the size of the prosthesis that preserves the ligaments to the best, in order to reduce as much as possible the stress imposed on bone/prosthesis interfaces and to limit the size of the prosthesis on which depends the amount of bone removed and the risk of septic complications. In rheumatic diseases prosthesis of the knee is the only sensible surgical treatment. Since the inflammatory process involves all three compartments of the knee, the prosthesis must be of the three-compartment type. In degenerative (gonarthrosis) and post-traumatic diseases of the knee, prosthesis is needed only when conservative surgery (osteotomy for realignment or malunion) is inadequate, with global femorotibial or femoropatellar involvement and major laxity of the ligaments. In global femorotibial diseases the prosthesis utilized can only be three-compartmental; in one-compartment femorotibial diseases, one-compartment prosthesis is rational if there is no lesion of the capsule and ligaments. When anatomical conditions are still compatible with conservative surgery, prosthetic surgery will be preferred only when the patient's general condition requires prompt resumption of walking.(ABSTRACT TRUNCATED AT 250 WORDS)

Arthritis, Rheumatoid↗

Performance assessment of the Terry Fox jogging prosthesis for above-knee amputees.

The Terry Fox jogging (TFJ) prosthesis was developed at Chedoke-McMaster Hospital to alleviate the asymmetric jogging pattern experienced by above-knee amputees when attempting to jog with conventional walking prostheses. This prosthesis features a spring-loaded, telescoping shank designed to eliminate any vaulting action and control the trunk motion during stance. The spring is intended to attenuate the impact forces and release its stored energy at push-off to provide momentum transfer to the jogger. This prosthesis was comprehensively assessed in the gait laboratory, by evaluating the kinematics, energy and power flow patterns of an above-knee amputee jogger wearing the TFJ prosthesis. Included in the assessment is the ability of the prosthesis to satisfy a set of relevant design criteria that have been established from non-amputee jogging patterns. An increased swing phase time for the prosthetic limb and the need to have the knee hyperextended throughout the stance phase contributed to an asymmetric jogging style. The telescoping action did lower the amputee's centre of mass, thereby reducing the vaulting effect. However, the spring only imparted a lifting action to the jogger and the ground reaction forces were double those of a non-amputee jogger. These findings clearly indicate a need to redesign the TFJ prosthesis and are being incorporated in the design of a new physiological jogging prosthesis.

Adult↗

[A study on knee joint geometry in Chinese: significance to prosthesis design].

This study for the first time provided the geometric parameters of knee joints in Chinese, which are indispensable for the design of domestic knee prosthesis. Thirty five items, including linear, radial and angular measurements, were taken from 105 cadaver knees and knee X-ray films of 100 subjects. The method and calculation for proper correction of the X-ray image magnification and joint cartilage space was established. Correlation between the X-ray correction coefficients and the body weight was found to exist, and it formed the basis for individualized correction of X ray measurements. Statistical analysis revealed that most of the linear and radial measurements were highly related while the angular measurements were independent of others. Principal component analysis showed that the width of femoral condyle might be taken as the leading index in determining the dimension of the knee, and regression functions were established. Multivariate discriminate functions could aid the selection of knee prosthesis.

Adolescent↗

Survivorship analysis of total knee arthroplasty with the kinematic prosthesis in patients who have rheumatoid arthritis.

Eighty-eight primary total knee arthroplasty procedures in 61 patients with rheumatoid arthritis were performed using the Kinematic total knee prosthesis (Howmedica, Rutherford, NJ) with cement between 1980 and 1985. No patients were lost to follow-up evaluation. Thirty-one of 61 patients died during the study period. Survivorship for all patients by life-table method was estimated as 56% at 10 years. This was shorter than the expected survival rate of a sex- and age-matched control group. Fifty procedure outcomes in 34 patients (27 women, 7 men) who were followed for more than 10 years were available for clinical evaluation. Complications occurred in 11 cases; in 4 of these, revision surgery was required. With revision as the endpoint, the survival rate of the prostheses was estimated as 93% at 10 years.

Adult↗

Total knee arthroplasty using the kinematic rotating hinge prosthesis.

Patients receiving a Kinematic Rotating Hinge total knee prosthesis with a 25-month minimum follow up were reviewed. A total of 46 patients and 54 knees were included in the study. A detailed clinical assessment was available on 38 knees. Twenty of these knees had primary arthroplasties performed with the Kinematic Rotating Hinge prosthesis and 18 knees had revision arthroplasty. Ninety-five percent of primary knees and 83% of revision knees caused no or mild pain postoperatively. Using the Brigham and Women's Hospital and Harvard Medical School knee rating system, 80% of primary knees and 61% of revision knees were rated as good to excellent. Using the criteria defined in this article, 90% of primary knees and 83% of revision knees were labeled as having a satisfactory result. Forty-five percent of primary components and 52% of revision components demonstrated lucent lines on radiographic review. Seven percent of primary knees and 20% of revision knees showed evidence of aseptic lucency progression in one or more zones. No radiographic evidence of aseptic loosening was noted in this review. Documented sepsis occurred in one primary knee and two revision knees. Patellar instability occurred in 21% of primary knees and 36% of revision knees, representing the major complication. The Kinematic Rotating Hinge prosthesis is intended for use in arthroplasty cases where there is functional absence of collateral ligament stability. This review suggests that a high percentage of satisfactory clinical results can be achieved with this prosthesis with long-term radiographic stability.

Activities of Daily Living↗

Femoral component sizing in total knee arthroplasty: size matched resection versus flexion space balancing.

Generally, 2 different methods are used to select femoral size. These can be termed "size-matched resection" and "flexion-space balancing." The purpose of this paper is to compare these 2 methods during 50 sequential total knee arthroplasty surgeries. The flexion-space-balancing method led to a smaller size selection than the size-matched-resection method in 28 (56%) knees. In the remaining 22 knees, the measurement methods led to the selection of the same size femoral component. The difference in measurement methods was significant (P<.05). The preoperative varus knees were more sensitive to the differences in measurement methods than the valgus knees (P<.05). A flexion space that is too small may adversely affect the clinical outcome of knee arthroplasty.

Arthroplasty, Replacement, Knee↗

A convex lateral tibial plateau for knee replacement.

Unicompartmental knee replacements have not performed as well in the lateral compartment as in the medial. This may be because the tibial components have flat or slightly concave surfaces which match the medial plateau but not the convex lateral plateau. The aim of this study was to find the optimal radius for a convex lateral tibial component. Twelve normal lateral tibial plateau were retrieved at knee replacement, and their surface contour in their mid sagittal plane was determined. The optimal circle was fitted and its radius measured. A series of different shaped tibial components were superimposed. From published information about the position of the femoral condyle relative to the tibia in different degrees of flexion, the flexion gap at these angles was determined. The average radius of the lateral tibial plateau was 40 mm. However, as the surface was polyradial it was not clear if this average radius would be optimal. In full flexion, a flat tibial plateau distracted the knee by 8 mm (p<0.001). A 75 mm radius spherical tibial plateau did not alter the knee kinematics significantly and gave rise to a change in joint distraction of 1.5 mm. Spherical tibial plateau of 50 mm and 25 mm radii significantly altered knee kinematics (p<0.001) and resulted in changes in distraction of 3 mm and 4 mm respectively. The optimal shape for a unicompartmental lateral tibial plateau is likely to be a spherical dome with radius of about 75 mm. The incorporation of this shape in the lateral side of a total knee replacement might improve its flexion.

Femur↗

Evolution of the rotating hinge for complex total knee arthroplasty.

Initial rotating hinge total knee designs were associated with a high failure rate. More recent designs have improved the patellofemoral articulation and the rotating hinge mechanism, added modular canal filling slotted fluted stems and metaphyseal sleeves, and improved the articulation between the mobile-bearing element and the tibial component. A series of patients with complex problems was studied. They underwent knee arthroplasty using a second generation rotating hinge component incorporating the design features listed above. Indications for surgery included medial collateral ligament disruption, revision of a previous hinged component with a massive bone loss, comminuted distal femur fracture or distal femoral nonunion in elderly patients, extensor mechanism disruption requiring reconstruction in an unstable knee, and ankylosis requiring femoral peel exposure with moderate residual flexion extension gap imbalance. A series of 23 knees in 22 patients was evaluated at the 2- to 9-year followup. The clinical results, range of motion, and satisfaction were comparable with that of a standard condylar revision knee arthroplasty despite the fact that the cases were more complex. These results warrant continued investigation of the role of rotating hinge in complex total knee arthroplasty.

Arthritis, Rheumatoid↗