Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Joint Instability”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57Linked to original sources

Effects of laterally wedged insoles on knee and subtalar joint moments.

OBJECTIVE: To assess the biomechanic effects of wearing a lateral wedge on the knee joint varus moment during gait in elders with and without knee osteoarthritis (OA). DESIGN: Crossover design whereby subjects walked under 2 different insole conditions: a 0 degrees control wedge and a 6 degrees lateral wedge. SETTING: A gait laboratory with 3-dimensional motion analysis and force platform equipment. PARTICIPANTS: Thirteen healthy subjects and 13 knee patients with OA. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Frontal plane angles and moments at the knee and subtalar joints, ground reaction forces, and center of pressure. Moments were derived by using a 3-dimensional inverse dynamics model of the lower extremity. RESULTS: The 6 degrees lateral wedge significantly reduced knee joint varus moment and increased subtalar joint valgus moment in both groups when compared with no wedge. All patients had a greater knee joint varus moment with a similar subtalar joint valgus moment compared with the people without OA. There were diverse, sometimes reversed effects with the insole among the patients. CONCLUSIONS: The 6 degrees lateral wedge did not consistently reduce the knee joint varus moment in patients with knee OA. The biomechanic indications and limitations of laterally wedged insoles should be confirmed by a larger study.

Biomechanical Phenomena↗

Function of the anterior cruciate ligament after unicompartmental knee arthroplasty: an in vitro robotic study.

The objective of this study was to investigate the role of the anterior cruciate ligament (ACL) in the anterior-posterior (AP) stability of the knee after unicompartmental knee arthroplasty (UKA). AP tibial loads were applied to human cadaveric knee specimens using a robotic testing system. After UKA, the knee exhibited tibial translations similar to that of the native knee, and the forces in the ACL were also similar to those seen in the native knee. The ACL-deficient knee after UKA exhibited significantly greater anterior tibial translations than the native knee and the knee after UKA with an intact ACL. These data suggest that medial UKA does not alter the anterior stability of the knee, but a functional ACL is necessary to ensure normal stability after UKA.

Aged↗

Lateral retinacular release as a function of femoral component rotation in total knee arthroplasty.

A consensus exists in the orthopaedic community that proper rotational placement of components may reduce the need for lateral release. This study compares the rates and results of lateral release before and after femoral component placement was defined by the transepicondylar axis (TEA). Between 1990 and 1991, 104 primary total knee arthroplasties (TKA) were reviewed during which equal amounts of bone from the posterior femoral condyles were removed. In this group, the lateral release incidence was 24% for varus deformities and 33% for valgus deformities. When the femoral component was externally rotated approximating the TEA, a review of 246 primary TKAs performed between 1998 and 1999 showed lateral release rates of 7% in varus deformities and 29% in valgus deformities. This study documents the statistically significant decline in the lateral release rate with external rotation of the femoral component during TKA in varus deformities (P<.0001), and a decreasing trend in valgus knees (P =.09).

Adult↗

Cemented posterior stabilized total knee arthroplasty.

In the development of modern cemented total knee arthroplasty, the posterior stabilized knee prosthesis was designed to substitute for the function of the posterior cruciate ligament. Implant designs include the Insall Burstein posterior stabilized knee and the Legacy posterior stabilized knee. The primary feature of these prostheses is the femoral cam and tibial spine mechanism, which prevents posterior tibial subluxation and enhances knee kinematics. Another important feature is the relatively conforming round on round articular geometry that mitigates edge loading and reduces polyethylene damage. In concert, these features have produced a lineage of implants with unsurpassed clinical results, predictable kinematics and durability, which have been reproducible and well documented.

Arthroplasty, Replacement, Knee↗

Posterior cruciate ligament substitution is not essential for excellent postoperative outcomes in total knee arthroplasty.

The study compared postoperative range of motion (ROM) and functional outcome of total knee arthroplasty (TKA) with a posterior cruciate ligament (PCL)-substituting knee prosthesis compared with an ultracongruent PCL-sacrificing design. Two hundred nine patients underwent primary TKA. Posterior stabilized design (121) and highly conforming, PCL-sacrificing, ultracongruent design (88) TKAs were reviewed. Surgeon, surgical approach, and a hyperflexion postoperative rehabilitation protocol were the same. Results showed significant improvement in knee flexion, ROM, Knee Score, and Function Score within each group. Postoperative mean total ROM was slightly higher with the posterior stabilized design. The 2 groups were the same postoperatively in the improvement in ROM, Knee Score, Function Score, satisfaction level, among other activity metrics. There was no clear evidence proving superiority and the need for posterior stabilization in PCL-sacrificing TKA.

Aged↗

The effect of oblique femoral tunnel placement on rotational constraint of the knee reconstructed using patellar tendon autografts.

PURPOSE: Despite the high long-term success rates of anterior cruciate ligament (ACL) reconstructions, 8% of patients undergoing this primary procedure have recurrent disability and graft failure. Nonanatomic tunnel positioning (primarily of the femoral tunnel) accounts for most of all technical failures. We hypothesized that reconstructions that closely recreate the oblique femoral attachment of the ACL would result in more normal knee rotational stability than more vertical reconstruction. The purpose of this study was to determine whether obliquity of the femoral tunnel in the coronal (frontal) plane has an effect on rotational constraint after ACL reconstruction, as measured by anterior tibial translation, external rotation, and internal rotation. TYPE OF STUDY: Ex vivo biomechanical study. METHODS: Ten matched pairs of fresh-frozen cadaver knees were alternately assigned to a standard or an oblique tunnel position reconstruction. Each knee was tested at 30 degrees and 90 degrees of flexion on a materials testing machine in ACL-intact, ACL-sectioned, and ACL-reconstructed states. A 100-N load was applied at a rate of 10 N/second, and anterior tibial translation was measured. Then 6.5 Nm of torque were applied, and external tibial rotation and internal tibial rotation were measured. The effects of tunnel placement and ligament condition were analyzed with a repeated measures analysis of variance. Significance was set at P < or =.05 (Tukey's test). RESULTS: At 30 degrees of flexion, internal tibial rotation in oblique reconstruction was restored to intact values and was significantly less than the internal tibial rotation values in standard reconstruction. Internal tibial rotation in standard reconstruction was significantly greater than intact values. No significant differences were found between standard and oblique tunnel reconstructions and the respective intact values for the remaining internal tibial rotation and all external tibial rotation tests, regardless of flexion angle. CONCLUSIONS: In our biomechanical model, ACL reconstructions using oblique femoral tunnels restored normal knee kinematics.

Aged↗

Lateral retinacular release: a survey of the International Patellofemoral Study Group.

PURPOSE: The purpose of this investigation was to determine current views regarding lateral release among experienced knee surgeons with a specific interest in the patellofemoral joint. TYPE OF STUDY: Scientific survey. METHODS: A questionnaire was developed and mailed to all members of an international group with a specific interest in disorders of the patellofemoral joint. Frequencies and percentages of responses were calculated for each question to determine surgeon consensus. We measured agreement among responses using the kappa statistic. This provided an indication of consistency for each question as well as correlation among the responses to different questions. RESULTS: The survey response rate was 60%. Isolated lateral release was estimated to account for only 1 to 5 surgical cases per respondent per year, or 2% of cases performed annually. In the setting of arthroscopy or exploration, 74% of respondents believed that lateral release calls for specific informed consent. Strong consensus was found that objective evidence is needed to justify lateral release, but agreement was poor as to what clinical evidence provides the most appropriate indication for the procedure. CONCLUSIONS: Even among experienced knee surgeons with a special interest in diseases of the patellofemoral articulation, isolated lateral release is rarely performed. Strong consensus was found that isolated lateral release should not be undertaken without prior planning in the form of objective clinical indications and preoperative informed consent. LEVEL OF EVIDENCE: Level V.

Arthroscopy↗

Patellar dislocation: arthroscopic patellar stabilization with anchor sutures.

There are many procedures to treat recurrent patellar subluxations and dislocations. Most of these procedures are open repairs for acute conditions or open reconstructions for chronic conditions, and both surgeries need large skin incisions. Although there are many arthroscopic procedures for meniscal and ligament injuries, there are very few arthroscopic procedures described for patellofemoral instability. In this report, we describe a new arthroscopic method to stabilize the patella for acute dislocation. Our technique includes an arthroscopic lateral release and a medial structure repair. We suggest that this procedure is minimally invasive and easier than traditional open procedures. Moreover, this may prevent patients from developing chronic instability of the patellofemoral joint.

Acute Disease↗

A new soft transglenoidal suture anchor for arthroscopic labrum fixation.

Inherent in most transglenoidal suture stabilization techniques of unstable shoulders is the unreliable fixation of posterior knots on the fascia. The transglenoidal suture anchor (TSA) technique overcomes this disadvantage. The TSA is a 1.5-cm loop of a No. 3 braided polyester thread with 5 knots. The loop is loaded with 1 or 2 sutures. Using a transglenoidal shuttle suture, it is pulled into a transglenoidal drill hole from the back in a retrograde fashion. The anchor is stopped at the posterior cortex of the glenoid by the knot. Using an arthroscopic suture passer technique (Bird Beak; Arthrex, Naples, FL) sutures are applied in the anterior-inferior part of the capsule, tied with a self-locking sliding knot, and secured with 2 or 3 additional throws. Two or 3 TSAs with 1 or 2 threads per anchor are used in most cases. The ultimate failure load of 10 samples of the anchor was tested with porcine scapulae. It was more than 156 N in every case. This technique enables the surgeon to use up to 4 anchors in the unstable shoulder with 1 or 2 sutures per anchor. The anchors are inexpensive. No problems are encountered in case of revision. There is no abrasion in the eyelet of the anchor as with metallic anchors and no synovitis as with some absorbable anchors.

Arthroscopy↗

Arthroscopic capsular plication-shift.

We describe a technique of arthroscopic capsular plication and shift used to address both anterior and posterior capsular laxity. This technique is used when the labrum is intact or if laxity persists after labral repair.

Arthroscopy↗

A prospective randomized comparison of bioabsorbable and titanium anterior cruciate ligament interference screws.

PURPOSE: To compare the Phantom bioabsorbable polymer interference screw (DePuy, Warsaw, IN) with a titanium metal interference screw when used in fixation of femoral and tibial bone blocks in central third bone-patellar tendon-bone autograft anterior cruciate ligament (ACL) reconstructions. TYPE OF STUDY: Multicentered prospective randomized study. METHODS: Two surgeons performed primary ACL reconstructions at different locations. Preoperatively, the patients were randomly assigned. One group received a titanium cannulated interference screw. The second group received the cannulated poly-L-lactic bioabsorbable Phantom screw. Data included subjective evaluation of activity level and International Knee Documentation Committee scores. Objective measures were made using the KT-1000 arthrometer (MedMetric, San Diego, CA), range of motion, presence of effusions, and complications intraoperatively or postoperatively. Measurements were made at 1 year and 2 years. Radiographic evaluation was carried out at least 2 years from the initial surgical date and interpreted by 2 independent orthopaedic surgeons. RESULTS: At the 1-year follow-up (N = 97), pain was reported more during moderate activity in the Phantom screw group (6) compared with the titanium screw group (0) (P = .03). No statistical difference between range of motion (P = .45), activity level (P = .83), swelling with activity (P = .95), partial (P = .13) or full (P = .31) giving way, knee effusions (P = .33), or KT-1000 side-to-side difference (P = .53) were found. At the 2-year follow-up (N = 65), more subjects (18) in the Phantom interference screw group reported activity levels in the strenuous category compared with those in the titanium interference screws (7) group (P = .02). No differences were reported with respect to pain (P = .97), effusion (P = .17), partial (P = .28) or full (P = .27) giving way, swelling with activity (P = .21), range of motion ( P = .64), or KT-1000 side-to-side difference (P = .96). Radiographic inspection showed no change in bone plug position, osteolysis, adverse effect, or complication caused by the bioabsorbable material. Some evidence of tunnel widening was seen in both groups. CONCLUSIONS: Use of a poly-L-lactic bioabsorbable interference screw can provide clinical results equal to that of a metal interference screw for fixation of a central third bone-patellar tendon-bone graft in ACL reconstruction. LEVEL OF EVIDENCE: Level II, therapeutic.

Absorbable Implants↗

Variation in anterior cruciate ligament scar pattern: does the scar pattern affect anterior laxity in anterior cruciate ligament-deficient knees?

PURPOSE: This prospective study documented patterns of scar formation after anterior cruciate ligament (ACL) rupture in order to test the hypothesis that ACL remnants can contribute to anterior knee passive motion limits tested with a ligament arthrometer. TYPE OF STUDY: Prospective cohort study. METHODS: Forty-eight consecutive patients undergoing ACL reconstructions had intra-operative ligament arthrometry testing before and immediately after preparation of the notch and debridement of the ACL remnant. Patterns of scar formation were compared with changes in knee laxity after debridement of the ACL remnant. RESULTS: Eighteen patients (38%) had ligament scarring to the posterior cruciate ligament (group 1). Four patients (8%) had scar tissue that appeared to extend from the ACL fibers to the roof of the notch (group 2). Six ACL remnants (12%) appeared to have healed to the lateral wall of the notch or the medial aspect of the lateral femoral condyle in a position anterior and distal to the ACL anatomic footprint (group 3). In 20 patients (42%), there was no identifiable ligament tissue remaining (group 4). Changes in anterior laxity were associated with the specific pattern of scar formation within the notch. The greatest increase in anterior laxity after debridement was observed in knees in which the injured ACL had an aberrant reattachment to the femur: group 1 (mean, -1.3 mm; P < .01), group 2 (mean, -3.4 mm; P < .05), and group 3 (mean, -4.3 mm; P < .05). In group 4, the change in knee laxity was not significant (mean, 0.2 mm; 95% CI, -0.29 to 0.74 mm). Overall, 14 of 48 knees (29%) loosened more than 2 mm after ACL resection ( P < .01). CONCLUSIONS: Resection of the ACL scar resulted in a measurable increase in passive anterior laxity in a subset of ACL-deficient knees. This increase in anterior laxity occurred in patients whose ligament healed to the femur, effectively crossing the joint. When performing arthroscopy without reconstruction in ACL-injured knees, we recommend caution in resecting the torn ACL or scar tissue because removal of this tissue contributed to increased anterior laxity in some ACL-deficient knees. LEVEL OF EVIDENCE: Level II, diagnostic study of consecutive patients.

Adult↗

Reconstruction of the medial patellofemoral ligament with autologous quadriceps tendon.

In knees with insufficient or previously disrupted medial retinacular and patellofemoral ligaments caused by subluxation or dislocation, anatomic reconstruction of the medial patellofemoral ligament may be performed. This procedure involves harvesting of an 8 x 70-mm medial quadriceps tendon graft, which leaves the quadriceps tendon retinacular attachment intact and avoids patellar and femoral drill holes. This graft is passed beneath the retinaculum adjacent to the femoral epicondyle and is sutured to the medial intermuscular septum-a procedure that reproduces the medial patellofemoral ligament and is supported by imbrication of the remaining medial retinaculum. The tension of the graft and of the medial retinaculum is set at closure with the knee in 30 degrees to 45 degrees of flexion; this allows the patella to be moved a distance equal to 25% of its width. Avoidance of drill holes allows the procedure to be used regardless of skeletal maturity and reduces fracture complications, inadequate graft placement, and failure of fixation. Postoperative rehabilitation includes immediate knee motion from 0 degrees to 90 degrees and partial weight bearing.

Arthroscopy↗

Volume analysis of arthroscopic capsular shift.

PURPOSE: To determine how much volume reduction can be obtained with varying amounts of arthroscopic capsular plication. METHODS: Six fresh-frozen, cadaveric specimens were used. Specimens were rejected if a rotator cuff tear was present. The volume of each shoulder joint was measured under 3 conditions: no capsular shift, 5-mm capsular shift, and 10-mm capsular shift. For each shift, 4 sutures were placed arthroscopically, 2 anteriorly and 2 posteriorly. Repeated measures were used to confirm the validity of the measurements. Data were analyzed with parametric and nonparametric tests. RESULTS: The average percentage of volume reduction at 5 mm of capsular plication from control was 16.2% (range, 9.7% to 21.5%). The percentage of volume reduction from control to 10 mm of capsular plication averaged 33.7% (range, 25.3% to 44.6%). Statistical significance was found with both parametric (P < .0001) and nonparametric tests (P < .0313). CONCLUSIONS: The current study found that capsular volume reduction was related to the amount of capsular plication with reproducible results. Capsular plication can produce volume reduction comparable to other techniques. CLINICAL RELEVANCE: The data could be used to determine the potential number of sutures and amount of tissue plication needed for the amount of laxity found at surgery.

Anthropometry↗

The influence of surface porosity on gap-healing around intra-articular implants in the presence of migrating particles.

The aim of the present study was to compare the effect of two different porous coatings on bone ongrowth and on the peri-implant migration of polyethylene (PE) particles. Porous-coated cylindrical implants with an either plasma-sprayed closed-pore coating (Pl) or titanium fiber metal open-pore coating (Fi) were inserted intra-articular in exact fit or with a 0.75 mm peri-implant gap. A weight-loaded implant device in the distal femur was used. We used a randomized paired design in eight dogs. PE particles were injected repeatedly intra-articular in the knee until the dogs were killed after 8 weeks. Fi implants had significantly more bone ongrowth 8 (0-21)% compared with Pl implants 0 (0-0)% in gap situations and reduced the number of peri-implant PE particles significantly. Among exact-fitted implants we found that peri-implant tissue around Pl implants consisted of significantly more fibrous tissue than around Fi implants. A sealing effect against the migration of PE particles was found for both Fi and Pl implants in exact fit.

Alloys↗