Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “DUST”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57Linked to original sources

A comparison of two surface sample collection devices for use in polymerase chain reaction based detection of Pneumocystis carinii in house dust.

A polymerase chain reaction assay was optimized to detect P. carinii cysts in composite dust samples. The optimal assay was capable of detecting as few as 10(3) P. carinii cysts in 50 mg of dust. Two dust collection devices were evaluated for efficiency and precision of collection of bulk dust and compatibility with the optimized PCR protocol for P. carinii DNA detection. A handheld vacuum cleaner equipped with a high-retention bag was found to be superior to a 37-mm filter cassette attached to an electrically powered vacuum pump in terms of dust collection efficiency (87% [n = 37] versus 81% [n = 35]), although the precision of the two devices as assessed by the standard deviation was similar (6.2% versus 6.3%). However, the vacuum cleaner method was not as compatible with the PCR-based detection assay as the filter cassette method. The filter cassette appears to be a better device for use in conjunction with PCR-based detection of P. carinii DNA in bulk dust samples from both smooth and carpeted surfaces.

DNA, Fungal↗

The effectiveness of handheld ventilated sanders in reducing inhalable dust concentrations.

Ventilated sanders are commonly used during aircraft surface abrasion but there is limited data on their effectiveness in reducing worker exposures. This study compared two handheld ventilated sander brands, DCM and Dynabrade, in a laboratory glovebox. Both sanders collect particulates by drawing air through holes in the sanding pads; the dust subsequently passes into a vacuum collection system. Aluminum panels coated with aircraft epoxy primer and polyurethane paint were abraded and inhalable dust concentrations were measured inside the glovebox with IOM samplers. The results indicate that both sanders effectively control inhalable dust, with the DCM sander reducing mass concentrations by 93 percent, and the Dynabrade by 98 percent, when the ventilation system is used. The Dynabrade unit, however, was more aggressive and produced over four times as much dust per unit time as the DCM unit. In spite of this, the Dynabrade sander adequately collected this additional dust. Varying abrasive grit size did not significantly affect dust generation, although the differences between the grit sizes used (180 and 240 grit) were not great and may have influenced the results.

Air Pollutants, Occupational↗

Achieving dust lead clearance standards after lead hazard control projects: an evaluation of the HUD-recommended cleaning procedure and an abbreviated alternative.

The U.S. Department of Housing and Urban Development's (HUD's) Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing strongly recommend that after lead hazard control interventions all walls, ceilings, floors, and other horizontal surfaces be cleaned using a three-step process to reduce lead-contaminated dust and debris. The three steps are: an initial vacuuming using a machine equipped with a high-efficiency particulate air (HEPA) filter (HEPA vacuum), wet wash with a lead cleaner, and a final HEPA vacuum. This study evaluated the effectiveness of two cleaning protocols: (1) the HUD-recommended three-step procedure, and (2) an abbreviated two-step cleaning procedure that omits the final HEPA vacuum. Cleaning procedures were evaluated in 27 dwelling units that had undergone significant lead hazard control interventions likely to produce lead dust. Dust lead samples were collected on floors and in window sills and troughs prior to the lead control hazard intervention, after the wet wash step of the cleaning procedure, and after completion of the second HEPA vacuuming. The results of the study demonstrate that dust lead surface loading on smooth and cleanable surfaces following the three-step and two-step cleaning procedures can achieve 1995 federal guidance dust clearance levels and levels substantially lower. Although the dust lead clearance rates before and after the second HEPA vacuum were the same, the time saved by omitting the second HEPA is small relative to the other elements of the cleaning process.

Air Pollution, Indoor↗

Identification of selected hormonally active agents and animal mammary carcinogens in commercial and residential air and dust samples.

In order to characterize typical indoor exposures to chemicals of interest for research on breast cancer and other hormonally mediated health outcomes, methods were developed to analyze air and dust for target compounds that have been identified as animal mammary carcinogens or hormonally active agents and that are used in commercial or consumer products or building materials. These methods were applied to a small number of residential and commercial environments to begin to characterize the extent of exposure to these classes of compounds. Phenolic compounds, including nonylphenol, octylphenol, bisphenol A, and the methoxychlor metabolite 2,2-bis(p-hydroxyphenyl)-1,1,1-trichloroethane (HPTE), were extracted, derivatized, and analyzed by gas chromatography/mass spectrometry (GC/MS)-selective ion monitoring (SIM). Selected phthalates, pesticides, polycyclic aromatic hydrocarbons (PAHs), and polychlorinated biphenyls (PCBs) were extracted and analyzed by GC/MS-SIM. Residential and workplace samples showed detectable levels of twelve pesticides in dust and seven in air samples. Phthalates were abundant in dust (0.3-524 micrograms/g) and air (0.005-2.8 micrograms/m3). Nonylphenol and its mono- and di-ethoxylates were prevalent in dust (0.82-14 micrograms/g) along with estrogenic phenols such as bisphenol A and o-phenyl phenol. In this 7-sample pilot study, 33 of 86 target compounds were detected in dust, and 24 of 57 target compounds were detected in air. In a single sample from one home, 27 of the target compounds were detected in dust and 15 in air, providing an indication of chemical mixtures to which humans are typically exposed.

Air Pollution, Indoor↗

An automatic sampler for measurement of dust-deposition rates around fugitive sources.

A wind-directional sampler for determination of dust-deposition rates has been developed, enabling the measurement of dust-deposition caused by a specific source and, at the same time, providing information on the dust-deposition rate for the background area. The sampler is called METDUST. This paper describes the results of a field evaluation of the METDUST sampler. The field evaluation was performed in a village in Southern Jutland, Denmark, where complaints of dust-deposition had occurred close to a power plant with large stockpiles of coal. The results showed that, out of a 9-month period, increased dust-deposition occurred downwind from the stockpiles during 4 months. Episodes were identified by comparison with the background deposition rate. The METDUST sampler offers an opportunity to measure the dust-deposition rate contributed by the source and the background simultaneously. It can, therefore, be used by environmental authorities to identify the "likelihood of complaint" and to define a suitable guideline for the case in question.

Air Pollutants↗

Enhancement of mite allergen-induced eosinophil infiltration in the murine airway and local cytokine/chemokine expression by Asian sand dust.

Data on the effects of sand dust toward allergic asthma produced by indoor allergens, such as house dust mites, are not currently available. This study was undertaken to clarify the role of Asian sand dust on mite allergen, Dermatophagoides farinae (D. farinae)-induced eosinophilic inflammation in the murine lung, using sand dusts from the Maowusu Desert (Inner Mongolia) (SD-1) and the Tengger Desert (China) (SD-2). ICR mice were intratracheally administered saline; SD-1 alone; SD-2 alone; D. farinae alone; D. farinae + SD-1; and D. farinae + SD-2, 4 times at 2-wk intervals. The two sand dusts enhanced infiltration of eosinophil in the airway, along with goblet-cell proliferation related to D. farinae. The degree of eosinophil infiltration induced with SD-2 was greater than with SD-1. The SD-1, which contained higher amounts of beta-glucan, increased the expression of interferon (IFN)-gamma in bronchoalveolar lavage fluids (BALF) with or without D. farinae, but SD-2 did not. Synergistically or cumulatively elevated levels of interleukin (IL)-5, eotaxin, and monocyte chemotactic protein in BALF related to D. farinae were higher with D. farinae + SD-2 than with D. farinae + SD-1. These results suggest that increased cytokine and chemokines in BALF play an important role in the enhancement of eosinophil infiltration in the airway induced by D. farinae + sand dusts. The reduced eosinophil infiltration in the SD-1-treated mice could be due to suppression of Th-2 cytokine and eotaxin via interferon-gamma induced by microbial materials, such as beta-glucan.

Animals↗

Effect of in vivo coal dust exposure on arachidonic acid metabolism in the rat alveolar macrophage.

Oxygenated metabolites of arachidonic acid (AA) are produced by the alveolar macrophage (AM) and have been shown to mediate inflammatory reactions. We therefore assessed the production of eicosanoids by AM harvested from the lungs of rats exposed to a bituminous coal dust for 2 wk in an inhalation chamber in order to determine if AA metabolism was altered in a manner that may promote an inflammatory response in the lung. Exposure to coal dust resulted in a 66% increase in the number of AM harvested, an increase in thromboxane A2 (TxA2) and leukotriene B4 (LTB4) production to 222% and 181% of control values, respectively, and a decrease in prostaglandin E2 (PGE2) production to 62% of control values. In AM harvested from rats allowed to breath clean air for 2 wk following coal dust exposure, PGE2 production returned to control levels but TxA2 and LTB4 production remained elevated. The TxA2 synthesis inhibitor UK 38,485 reduced TxA2 production in dust-exposed AM both immediately and 2 wk following exposure. Thus, exposure of rats to coal dust significantly alters the metabolism of AA in AM, with potentially important aspects of AA metabolism remaining altered even after a 2-wk recovery period. Based on the established role of eicosanoids in inflammatory and fibrotic processes, these results suggest that the alteration of AM eicosanoid production as a result of the inhalation of coal mine dust may be an important factor in the pathophysiology of coal workers' pneumoconiosis.

Animals↗

Exposure to dust, resin acids, and monoterpenes in softwood lumber mills.

A study to assess exposure to potential respiratory hazards in a large lumber mill processing spruce (Picea engelmannii and glauca), pine (Pinus contorta), and fir (Abies lasiocarpa) used a random sampling strategy to assess exposures for all jobs in the sawmill, planer mills, and yard. Personal samples for inhalable particulate were collected to measure exposure to dust and resin acids (abietic acid and pimaric acid). To estimate wood dust exposure, rather than overall dust, the resin acid content within dust was used in combination with observations of job tasks and proximity to dust sources. Passive dosimeters were used to measure exposure to alpha-pinene, beta-pinene, delta3-carene, and other unidentified wood volatiles suspected to be monoterpenes. The GM of the 220 inhalable particulate samples was 1.0 mg/m3 whereas the mean abietic acid, pimaric acid, and estimated wood dust levels were 7.2 microg/m3, 0.6 microg/m3, and 0.5 mg/m3, respectively. The GMs of the 222 monoterpene samples were 0.1 mg/m3 for alpha-pinene, 0.3 mg/m3 for beta-pinene, 0.1 mg/m3 for delta3-carene, and 0.5 mg/m3 for the unidentified wood volatiles. Monoterpene exposures were much lower than those observed in other studies conducted in Sweden and Finland. The results of this exposure assessment highlight the importance of considering the content of airborne particulates in lumber mills as well as potential exposure to wood chemicals.

Abietanes↗

Malathion and diazinon levels in grain dust from New Orleans area grain elevators.

Insecticides applied to grain may be present in dust generated during grain handling and could expose workers to high insecticide concentrations, or be fed to animals in the form of pelleted grain dust. Residual levels of two organophosphate insecticides, malathion and diazinon, were measured in 31 samples of grain dust collected from six terminal grain elevators along the Mississippi River in the New Orleans area. These grain elevator samples and additional spiked samples were extracted and analyzed by gas chromatography. The lower limit of detection for malathion was 0.1 micrograms/g and for diazinon, 0.01 micrograms/g. Recovery of malathion from samples spiked with less than 1 micrograms/g was erratic. Mean recoveries of both malathion and diazinon from spiked samples ranged from 83 to 92% at levels of 1 to 50 micrograms/g of dust. Samples of grain dust from the elevators contained 0.17 to 32 micrograms of malathion/g of dust, but diazinon was not detectable at the 0.01 micrograms/g limit of detection.

Chromatography, Gas↗

Comparison of dust samplers: statistical analysis techniques.

Statistical analyses comparing pairs of dust samplers were carried out using five models, a straight line through the origin, linear with intercepts, logarithmic, a logarithmic (weight + constant), and a fifth forced through the origin. The fourth and fifth models combined the arithmetic portion of the error, associated with weighing and handling, with the geometric portion, associated with sampling and the dust cloud variations, into a unified geometric form. It was shown that some of the assumptions on which the least squares method of regression analysis are based were not met and that corrections had to be made. In most cases no significant difference was found between the corrected regression lines and the expected physical relation, a straight line through the origin. In the exceptions physical reasons were found to support the nonlinearity found in statistical analysis. It is suggested that the best estimate of the relation between two dust samplers can be obtained by a least squares determination of the straight line through the origin using transformed variables. A method is given for determining values of the constants. The application of this statistical method to comparisons between dust samplers not measuring the same parameter of the dust cloud is discussed with an example. The considerations in assessing historical dust measurements are outlined.

Air Pollutants↗

Exposure to wood dust and heavy metals in workers using CCA pressure-treated wood.

Chemical pesticide treatment enables relatively nonresistant woods to be used in outdoor construction projects. The most prevalent procedure used to protect these woods is pressure treatment with chromium, copper, and arsenic (CCA). This pilot study examined the airborne concentration and particle size distribution of wood particles, chromium, copper, and arsenic at both outdoor (measured over the whole work day) and indoor (measured during the performance of specific tasks) work sites. At the outdoor residential deck construction sites, the arithmetic mean total dust concentration, measured using personal filter cassette samplers, was 0.57 mg/m3. The mass median aerodynamic diameter (da) of the outdoor wood dust was greater than 20 microm. Indoor wood dust concentrations were significantly greater than those measured outdoor and were job category-dependent. The highest mean breathing zone dust concentration, 49.0 mg/m3, was measured at the indoor sanding operation. Personal impactor sampling demonstrated that the mean total airborne concentration of arsenic, but not chromium or copper, was consistently above recommended occupational exposure levels at the indoor work site, and occasionally at the outdoor work sites. At the indoor sanding operation, the mean total chromium, copper, and arsenic concentrations were 345, 170, and 342 microg/m3, respectively. Thus, significant exposure to airborne heavy metals can occur as a result of indoor and outdoor exposure to CCA pressure-treated wood dust. Therefore, current standards for wood dust may not adequately protect workers from the heavy metals commonly used in CCA pressure-treated wood.

Air Pollutants↗

Clean-up of lead in household carpet and floor dust.

Methods to remove lead-containing dust were tested on carpets from homes of children with high blood lead and on new carpets artificially contaminated in the laboratory. The household carpets could not be cleaned effectively by repetitive vacuuming with HEPA-filtered cleaners. The lead concentration in the removed dust remained about the same from the initial cleaning (1 min/m2) to the final cleaning (total cleaning time of 10 min/m2). The lead loading on the surface of the carpets often increased during cleaning because vacuuming brought lead from deeper in the carpet to the surface. Over 95% of the total dust was removed from bare wooden floors by dry vacuuming (5 min/m2). For linoleum, more than 75% was removed by vacuuming for 5 min/m2. However, little was removed in vacuuming after the initial two minutes and about 20% was removed in a final wet-washing step. HEPA-vacuuming of the laboratory-contaminated carpets revealed that two of the commercially available vacuum cleaners tested were essentially equivalent and each removed significantly more dust than a third vacuum during a total cleaning time of 10 min/m2. Cleaning for 6 min/m2 was necessary to remove more than 70% of the embedded dust by the two more efficient vacuums. Cleaning efficiencies were about the same for short pile and sculptured carpets. It was concluded that it may be more practical to replace rather than clean carpets. HEPA-vacuum cleaning of carpets was shown to increase lead dust on the surface under some conditions.

Dust↗

Factors affecting the retention of dust mite allergen on carpet.

Carpeting is one of the most common and perhaps the most important reservoir of aeroallergens and other components of dust found in residential or commercial settings. This research evaluated factors that affect the retention of dust mite allergens on different types of tufted carpet commonly found in homes and offices. Twenty-six types of carpet were custom manufactured as part of a two-stage factorial experiment using 182 carpet samples. Carpets differed with respect to fiber denier, cross-sectional shape, presence of fluorocarbon treatment, carpet style, pile height, and pile density. The major hypothesis tested was that the amount of allergen-containing dust recovered from vacuum samples of tufted carpet sources was dependent on micro (fiber) or macro (construction) retention characteristics of the carpets. Carpet samples were doped in a uniform and reproducible manner using an allergen-containing reference dust. A standardized vacuum surface sampler was used to recover dust from samples. Allergen was assayed using a standard, monoclonal antibody ELISA. Carpet-surface area and presence of fluorocarbon were found to have the largest effects on retention and recovery of dust and allergen. Specifically, fluorocarbon treatment of fibers, square-hollow fiber shape, high-denier fiber, low-pile height in cut-pile carpets, and low-pile density in loop carpets were significantly associated with increased release and recovery of allergen. Results from this study suggest that carpet type be considered for both allergen avoidance and allergy and asthma risk assessment.

Allergens↗

House dust collection efficiency of the high volume small surface sampler on worn carpets.

The High Volume Small Surface Sampler (HVS3) is a dust-sampling vacuum that allows for set airflow and back pressure during sampling, increasing precision. Total dust collection efficiency of the HVS3 has been evaluated only on new carpets-not worn carpets. We performed a factorial study to assess the impact of carpet wear, dust deposition level, carpet type, and relative humidity during sampling on HVS3 collection efficiency. House dust was aerosolized in a 1-m3 exposure chamber and allowed to settle on test carpets and reference filters. Dust was embedded into the carpets and later extracted with the HVS3 under controlled environmental conditions according to established protocols. Overall collection efficiency was high, 88.3%. Collection efficiency was significantly higher at low relative humidity levels (30%) relative to high (75%) (p = < 0.0001), though differentially between cut-pile and closed-loop carpets. Collection efficiency of carpets with high wear was significantly lower than those with midlevel wear (p = 0.01). These results demonstrate that the design of the HVS3 partially corrects for differences in dust load and carpet type. However, collection efficiency of the HVS3 is affected by high levels of carpet wear and ambient humidity during sampling.

Analysis of Variance↗

Removal dynamics of airborne road dust in a ventilated airspace.

We derive a simple linear dynamic equation to describe the removal mechanisms of airborne road dust from a ventilated airspace. The dynamic equation is sufficiently to take into account the simultaneous removal effects of turbulent coagulation, turbulent diffusive deposition, gravitational sedimentation, and airflow pattern within a ventilated airspace. Three dimensionless parameters TC, TD, and GS that characterize the relative effects of turbulent coagulation, turbulent diffusive deposition and gravitational settling, respectively, in a ventilated airspace were introduced to generalize the removal dynamics of airborne road dust. An environmental chamber test was carried out not only to determine the particle size distributions but also to verify the removal dynamics of airborne road dust in a ventilated airspace. Our results demonstrate that there is no significant variation for particle size distributions of road dust obtained from urban and suburban areas in north Taiwan region and both followed a lognormal distribution with average geometric mean diameter of 1.08 +/- 0.02 microm and geometric standard deviation of 2.59+/-0.03. Measured values match the simulated values with an r2 value of 0.93, whereas the overall RMSE value of 2.36 +/- 1.05 mg m(-3) is low, indicating that the ability to predict the removal dynamics of airborne road dust within a ventilated airspace using an average particle size based linear equation. Effects of TC, TD, GS, and various ventilation systems on the time-dependent road dust concentrations are also justified.

Air Movements↗

Theoretical studies of the infrared emission from circumstellar dust shells: the infrared characteristics of circumstellar silicates and the mass-loss rate of oxygen-rich late-type giants.

We have modeled the infrared emission of spherically symmetric, circumstellar dust shells with the aim of deriving the infrared absorption properties of circumstellar silicate grains and the mass-loss rates of the central stars. As a basis for our numerical studies, a simple semianalytical formula has been derived that illustrates the essential characteristics of the infrared emission of such dust shells. A numerical radiative transfer program has been developed and applied to dust shells around oxygen-rich late-type giants. Free parameters in such models include the absorption properties and density distribution of the dust. An approximate, analytical expression is derived for the density distribution of circumstellar dust driven outward by radiation pressure from a central source. A large grid of models has been calculated to study the influence of the free parameters on the emergent spectrum. These results form the basis for a comparison with near-infrared observations. Observational studies have revealed a correlation between the near-infrared color temperature, Tc, and the strength of the 10 micrometers emission or absorption feature, A10. This relationship, which essentially measures the near-infrared optical depth in terms of the 10 micrometers optical depth, is discussed. Theoretical A10-Tc relations have been calculated and compared to the observations. The results show that this relation is a sensitive way to determine the ratio of the near-infrared to 10 micrometers absorption efficiency of circumstellar silicates. These results as well as previous studies show that the near-infrared absorption efficiency of circumstellar silicate grains is much higher than expected from terrestrial minerals. We suggest that this enhanced absorption is due to the presence of ferrous iron (Fe2+) color centers dissolved in the circumstellar silicates. By using the derived value for the ratio of the near-infrared to 10 micrometers absorption efficiency, the observed A10-Tc relation can be calibrated in terms of the total dust column density of the circumstellar shell and thus the mass-loss rate of late-type giants can easily be derived. Detailed models have been made of the infrared emission of three well-studied Miras: R Cas, IRC 10011, and OH 26.5+0.6, with the emphasis on the shape of the 10 micrometers emission or absorption feature. The results show that the intrinsic shape of the 10 micrometers resonance varies from a very broad feature in R Cas to a relatively narrower feature in OH 26.5+0.6, with IRC 10011 somewhere in between. Possible origins of this variation are discussed. The mass-loss rates from these objects are calculated to be 3 x 10(-7), 2 x 10(-5), and 2 x 10(-4) M Sun yr-1 for R Cas, IRC 10011, and OH 26.5+0.6, respectively. These results are compared to other determinations in the literature.

Astronomical Phenomena↗

The albedo and scattering phase function of interstellar dust and the diffuse background at far-ultraviolet wavelengths.

We have determined the scattering parameters of dust in the interstellar medium at far-ultraviolet (FUV) wavelengths (1415-1835 angstroms). Our results are based on spectra of the diffuse background taken with the Berkeley UVX spectrometer. The unique design of this instrument makes possible for the first time accurate determination of the background both at high Galactic latitude, where the signal is intrinsically faint, and at low Galactic latitude, where direct starlight has heretofore compromised measurements of the diffuse emission. Because the data are spectroscopic, the continuum can be distinguished from the atomic and molecular transition features which also contribute to the background. We find the continuum intensity to be well correlated with the Galactic neutral hydrogen column density until saturation at about 1200 photons cm-2 s-1 sr-1 angstrom-1 is reached where tau FUV approximately 1. Our measurement of the intensity where tau FUV > or = 1 is crucial to the determination of the scattering properties of the grains. We interpret the data with a detailed radiative transfer model and conclude that the FUV albedo of the grains is low (<25%) and that the grains scatter fairly isotropically. We evaluate models of dust composition and grain-size distribution and compare their predictions with these new results. We present evidence that, as the Galactic neutral hydrogen column density approaches zero, the FUV continuum background arises primarily from scattering by dust, which implies that dust may be present in virtually all view directions. A non-dust-scattering continuum component has also been identified, with an intensity (external to the foreground Galactic dust) of about 115 photons cm-2 s-1 angstrom-1. With about half this intensity accounted for by two-photon emission from Galactic ionized gas, we identify roughly 50 photons cm-2 s-1 sr-1 angstrom-1 as a true extragalactic component.

Astronomy↗

Characterization of airborne dust in a soft paper mill.

The characteristics of airborne dust in a soft paper production plant have been characterized by scanning and transmission electron microscopy. A combination of X-ray diffraction, electron diffraction and energy-dispersive X-ray flouresence spectroscopy (EDX) was used to determine the structure and composition of the different components. Size distribution determination and phase identification were carried out. Besides the cellulose fibres, fibres of kaolinite, wollastonite, talc and other silicates were also identified. Gravimetric analysis and fibre counting by optical phase contrast microscopy were used to determine total dust and fibre concentrations. Total dust exposure at the plant was generally below 3 mg m-3. The respirable fraction of the total dust concentrations varied from 15 to 70%. The inorganic dust was 36 +/- 15% of the total dust. The ratio of inorganic fibres to total fibre concentration at the plant varied between 10 and 15%.

Air Pollutants, Occupational↗