Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Color Perception”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57Linked to original sources

Closure and acuity in pseudoisochromatic color tests.

While visual acuity was related to performance on several pseudoisochromatic color tests for 73 male college students, no evidence was found that perceptual closure also affected performance. No scores were correlated for the 69 undergraduate women.

Age Factors↗

Lüscher color preferences of Arctic Inuit and of southern Canadians.

A comparison of color preferences based on the Lüscher Color Test was made for 21 Inuit residing within the Arctic circle and those of 49 residents of Southern Canada. These two groups have been raised in radically different physical and cultural environments. We expected that such factors could influence color preferences; however, no statistically significant differences were found in relative preferences for blue, green, red, yellow, purple, brown, grey, and black for our data based on Lüscher's scoring and those on our own scoring system independent of Lüscher's theory and scoring.

Adult↗

The importance of controlled illumination in color vision testing in a pediatric ophthalmology clinical practice.

The AO-HRR pseudoisochromatic plates are commonly used for color vision testing in pediatric ophthalmology; however, the recommended procedure for obtaining proper illumination (a completely darkened room and standard illuminant) is typically not followed. To evaluate the role of the illuminant in clinical testing with the AO-HRR, 132 children, ages 3 to 16 years, were tested with and without the recommended illuminant (MacBeth Easel Lamp) and with the self-illuminated APT-5 Color Vision Tester. Twenty-two failed the AO-HRR with the recommended illuminant; 28 failed the AO-HRR without the illuminant. Only 13 failed the APT-5. The Cochran Q test for three related samples showed that the differences among the three groups were significant (Q = 17.1, P < .001). Diagnostic evaluation following clinical screening indicated that the differences among the tests were primarily due to false alarms, which were greatest without the recommended illuminant and least with the APT-5. These results demonstrate the importance of controlled illumination in color vision testing, either by using the recommended illumination with the AO-HRR or a self-illuminated test such as the APT-5.

Adolescent↗

Visual acuity and colour vision tests--a preliminary report.

Results are reported of a preliminary survey of colour vision changes in fifteen patients with central serous retinopathy. Colour vision was monitored with the HRR plates, 100-hue test and Nagel anomaloscope. In those patients revealing an acquired dyschromatopsia the defect had a tritan-like response. However, diagnosis is made difficult because of the positively correlated trend between 100-hue error score and visual acuity.

Adult↗

Aircrew visors and color vision performance: a comparative and preliminary pilot study analysis.

BACKGROUND: A very important aspect of visual performance to consider, for present and future recommendations regarding aircrew visors, concerns their impact on color vision. The literature has remained mostly inconclusive with respect to the human perceptual process of colors during actual mission employment. OBJECTIVE: This study uses active duty military aircrews to provide objective and valuable information on the effects of Short Wavelength Absorbing Filters (SWAFs), such as the High Contrast Visor (HCV), and some selected waveband type Laser Eye Protection (LEP) visors on color vision. It provides a direct comparison of several current and proposed aircrew eye protective visors with respect to their effects on color vision. The data analyzed in this study will also be used to support a recommendation regarding a new optimal visor for aircrew wear during air to air (and ground) engagements, for sun protection, and possible visual enhancement in order to improve user compliance. METHODS: Seven volunteers on active flying status each underwent comprehensive color vision testing with and without seven of the U. S. Air Force's (USAF's) current or proposed aircrew visors/filters. Spectral transmissions of these visors/filters were obtained to identify and determine their individual characteristics which included their ability to induce acquired color vision decrements in "color normal" individuals. RESULTS: The widely utilized USAF HCV significantly degraded color vision more than luminosity matched neutral density visors. Abrupt color vision decrements for specifically fielded LEP visors were also noted. Their objective data supported theoretical and speculated color vision effects. Even though low transmittance neutral density visors did have some effect on color vision, decrement severity was not considered significant enough to affect overall performance during color vision testing. CONCLUSIONS AND DISCUSSION: Because of their ability to significantly affect color vision, concerns regarding the use of HCV and LEP visors should entail age, baseline color vision, environmental, and mission factors. Further testing should be done to evaluate the definitive effects that these visors actually have on the recognition of color symbology of Multi Function and Electronic Flight Information Displays. Findings in this study also support theoretical opinions that encourage the fielding of a neutral density filter (mildly tinted) with an overall transmission of 25-49%. Its use by flyers during low and bright illuminant conditions may greatly enhance visual performance by encouraging wearer compliance while allowing colors to be perceived normally.

Adult↗

Cone-specific mediation of rod sensitivity in trichromatic observers.

PURPOSE: The slope of the rod threshold versus the illuminance (TVI) function changes with the wavelength of the background light. This study was conducted to determine whether the changes in slope are due to the stimulation of specific cone classes. METHODS: An eight-channel optical system was used to generate lights that differed in cone and rod photoreceptor illuminance. Rod flicker TVI functions were measured in normal trichromatic observers at mesopic light levels. The independent variables were (1) the relative contribution of the short (S)- and long (L)- wavelength cones to the background light (i.e., the background lights varied along S-only and L-only lines), and (2) the temporal frequency of the flickering lights (4, 7.5, and 15 Hz). RESULTS: The 4-Hz rod flicker TVI function had a slope of 0.87 when measured near W (MacLeod-Boynton chromaticity of 0.66, 1.0). At 4 and 7.5 Hz, an increase in the relative L-cone illuminance steepened the slope of the rod-only TVI curve, but an increase in the relative S-cone illuminance had no effect. The slope of the 7.5-Hz TVI function decreased at higher illuminance levels. At 15 Hz, the thresholds could be measured over only a limited range. CONCLUSIONS: The L-cone system contributes to the desensitization of the rod system at mesopic light levels, whereas, in the range of lights used in these experiments, the S-cone system apparently does not. The possibility that S-cone stimulation desensitizes the response to rod signals at higher levels of S-cone illumination cannot be eliminated.

Adult↗

Are ethnic differences in the F-M 100 scores related to macular pigmentation?

BACKGROUND: It is known that the macular pigment can significantly affect colour matching and other aspects of colour vision tests. The difference in macular pigmentation between Asians and Caucasians may lead to different colour discrimination. METHODS: This study compared chromatic discrimination between Asians and Caucasians using the Farnsworth-Munsell 100 Hue test. Fifty Asians who were ethnically Chinese and 50 Caucasians served as subjects, ranging in age from 30 to 59 years. RESULTS: The partial blue-yellow square root error score of the Asian subjects was significantly higher than that of the Caucasian subjects (p = 0.022) and the difference appeared to increase with age. DISCUSSION: There was a difference in the F-M 100 scores between the two groups. The difference was confined in the blue-yellow region, producing a tritan-like bias for the Asian group in the test.

Adult↗