Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Analytic Sample Preparation Methods”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57Linked to original sources

Automated in-tube solid-phase microextraction-high-performance liquid chromatography for carbamate pesticide analysis.

In-tube solid-phase microextraction (SPME) is an automated version of SPME that can be easily coupled to a conventional HPLC autosampler for on-line sample preparation, separation and quantitation. It has been termed "in-tube" SPME because the extraction phase is coated inside a section of fused-silica tubing rather than coated on the surface of a fused-silica rod as in the conventional syringe-like SPME device. The new in-tube SPME technique has been demonstrated as a very efficient extraction method for the analysis of polar and thermally labile analytes. The in-tube SPME-HPLC method used with the FAMOS autosampler from LC Packings was developed for detecting polar carbamate pesticides in clean water samples. The main parameters relating to the extraction and desorption processes of in-tube SPME (selection of coatings, aspirate/dispense steps, selection of the desorption solvents, and the efficiency of desorption solvent, etc.) were investigated. The method was evaluated according to the reproducibility, linear range and limit of detection. This method is simple, effective, reproducible and sensitive. The relative standard deviation for all the carbamates investigated was between 1.7 and 5.3%. The method showed good linearity between 5 and 10000 microg/l with correlation coefficients between 0.9824 and 0.9995. For the carbamates studied, the limits of detection observed are lower than or similar to that of US Environmental Protection Agency or National Pesticide Survey methods. Detection of carbaryl present in clean water samples at 1 microg/l is possible.

Carbamates↗

Determination of cefaclor in human plasma by a sensitive and specific liquid chromatographic-tandem mass spectrometric method.

A sensitive and specific liquid chromatographic-tandem mass spectrometric method is described for the determination of cefaclor in human plasma. The plasma samples were treated by two sample preparation procedures, i.e. protein precipitation (PPT) and solid-phase extraction (SPE). The pretreated samples were analyzed on a C(18) HPLC column interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization (ESI) was employed as the ionization source. The analyte and internal standard ampicillin (for PPT) or cefetamet (for SPE) were detected by use of selected reaction monitoring (SRM) mode. The lower limit of quantitation obtained as a result of the PPT procedure was 100 ng/ml. The intra- and inter-run precision, calculated from quality control (QC) samples was less than 12% for cefaclor. The accuracy as determined from QC samples was within +/-3% for the analyte. The SPE procedure could provide the lower limit of quantitation of 2 ng/ml. The precision and accuracy were measured to be below 7.1% and between -3.6% and 1.1%, respectively, for all QC samples. The method was applied for the evaluation of the pharmacokinetic profiles of cefaclor sustained-release formulation.

Anti-Bacterial Agents↗

Analysis of CL-20 in environmental matrices: water and soil.

Analytical techniques for the detection of 2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazatetracyclo(5.5.0.05,9.03,11)dodecane (CL-20) in water and soil are developed by adapting methods traditionally used for the analysis of nitroaromatics. CL-20 (a new explosives compound) is thermally labile, exhibits high polarity, and has low solubility in water. These constraints make the use of specialized sample handling, preparation, extraction, and analysis necessary. The ability to determine the concentrations of this new explosive compound in environmental matrices is helpful in understanding the environmental fate and effects of CL-20; understanding the physical, chemical, and biological fate of CL-20; and can be used in developing remediation technologies and determining their efficiency. The toxicity and mobility of new explosives in soil and groundwater are also of interest, and analytical techniques for quantitating CL-20 and its degradation products in soil and natural waters make these investigations possible.

Journal Article↗

Liquid chromatographic method for determination of arprinocid in feed: collaborative study.

An HPLC method for determining arprinocid [9-(2-chloro-6-fluorophenyl)methyl-9H-purin-6-amine] in feed was evaluated in an interlaboratory collaborative study. The samples were prepared in pairs from feeds obtained from 2 commercial feed manufacturers to cover the concentration range 0.0050-0.0070% arprinocid and were distributed to 14 laboratories. Each collaborator was requested to perform one determination on each of 6 samples. In this analytical procedure, the drug is extracted into CHCl3 and, after appropriate sample preparation by liquid-liquid partitioning, determined using a silica column and ultraviolet detection. The means of the analyses reported by the collaborators ranged from 97 to 104% of the true concentration of arprinocid and were not significantly different (P greater than 0.1) from the true values. The average coefficient of variation was 6.8%. The precision standard deviations of the 3 unit blocks (sr) were each less than 0.0004% arprinocid, and the F-test demonstrated that systematic error (sb) did not make a statistically significant contribution (P greater than 0.1) to the standard deviation of the data (sd). This method has been adopted official first action.

Adenine↗

Evaluation of the repeatability of a crude adult indirect Ostertagia ostertagi ELISA and methods of expressing test results.

An indirect enzyme-linked immunosorbent assay (ELISA) for the detection of antibodies against Ostertagia ostertagi using a crude adult worm antigen was evaluated using serum and milk samples from adult cows, as well as from bulk tank milk. Within and between plate repeatabilities were determined. In addition, the effects of factors such as antigen batch, freezing, preserving of the samples and somatic cell counts (SCCs) of the samples were evaluated. Raw optical densities (ODs) and normalized values were compared using the concordance correlation coefficient (CCC), the coefficient of variation (CV), Bland-Altman plots (BA). Based on raw OD values, there was a high repeatability within a plate (CCC approximately 0.96 and CV<10%). Repeatability between plates was evaluated following normalization of OD values by four methods. Computing normalized values as (OD-Nt)/(Pst-Nt), gave the most repeatable results, with the CCC being approximately 0.95 and the CV approximately 11%. When the OD values were higher than 1.2 and 0.3 for the positive and the negative controls, respectively, none of the normalization methods evaluated provided highly repeatable results and it was necessary to repeat the test. Two batches of the crude antigen preparation were evaluated for repeatability, and no difference was found (CCC=0.96). The use of preservative (bronopol) did not affect test results, nor did freezing the samples for up to 8 months. A significant positive relationship between ELISA OD for milk samples and SCC score was found. Therefore, the use of composite milk samples, which have less variable SCC than samples taken from each quarter, would be more suitable when the udder health status is unknown. The analytical methods used to evaluate repeatability provided a practical way to select among normalization procedures.

Animals↗

Ion chromatography characterization of polysaccharides in ancient wall paintings.

An analytical procedure for the characterisation of polysaccharides and the identification of plant gums in old polychrome samples is described. The procedure is based on hydrolysis with 2 M trifluoroacetic acid assisted by microwaves (20 min, 120 degrees C, 500 W), clean-up of the hydrolysate by an ion-exchange resin, and analysis by high-performance anion-exchange chromatography with pulsed amperometric detection. Using this method the hydrolysis time was reduced to 20 min and the chromatographic separation of seven monosaccharides (fucose, rhamnose, arabinose, galactose, glucose, mannose, xylose) and two uronic acids (galacturonic and glucuronic) was achieved in 40 min. The whole analytical procedure allows sugar determination in plant gums at picomole levels, with an average recovery of 72% with an RSD of 8% as tested on arabic gum. The analytical procedure was tested with several raw gums, watercolour samples and reference painting specimens prepared according to old recipes at the Opificio delle Pietre Dure of Florence (Italian Ministry of Cultural Heritage, Italy). All the data collected expressed in relative sugar percentage contents were submitted to principal components analysis for gum identification: five groups were spatially separated and this enabled the identification of arabic, tragacanth, karaya, cherry+ghatty, and guar+locust bean gum. Wall painting samples from Macedonian tombs (Greece) of the 4th-3rd Centuries B.C., processed by the suggested method, showed the presence of a complex paint media mainly consisting of tragacanth and fruit tree gums. Moreover, starch had probably been added to plaster as highlighted by the presence of a huge amount of glucose.

Art↗

[A new method for the continuous determination of ethrane in the blood and the expired air by means of gaschromatography as end-analytic system (author's transl)].

A method for continuous measurement of the anaesthetic Ethrane in blood and gas samples is described. Using the same GC-parameters for the analyses of gases and blood extracts, a short GC-column together with high oven temperature as well as shortening of preparation (extraction) time allows the analysis of two blood samples and one gas sample within 15 minutes' steps (the time for an additional gas sample analysis being max. 3 min). Thus a quasi simultaneous follow up of the course of anaesthesia in animals and in humans may be guaranteed.

Chromatography, Gas↗

Determination of steroid estrogens in wastewater by immunoaffinity extraction coupled with HPLC-electrospray-MS.

A new method, based on immunoaffinity extraction coupled with liquid chromatography/electrospray mass spectrometry (LC/ESI-MS) is described for the determination of the steroid estrogens beta-estradiol (E2), estrone (E1), and alpha-ethynylestradiol (E2) in wastewater. The use of highly selective immunosorbents in sample preparation prior to analysis allows the removal of interfering sample matrix compounds present in the wastewater extracts that would otherwise cause severe ionization suppression of the estrogens during the electrospray process. In addition, immunoextraction removes much of the isobaric noise from the selected ion monitoring chromatograms, increasing the signal-to-noise ratios for analytes, and contributing to the low detection limits (0.18 and 0.07 ng/L for E2 and E1, respectively) achieved by the current method. The method was applied to analysis of estrogens in two wastewater effluents. Recoveries of E2 and E1 were excellent (>90%), while the nonimmunogen (but structurally related) analyte EE2 was not retained (recovery <2%) from effluent extracts by the immunosorbent. This illustrates the extreme selectivity of the immunoextraction purification step. Precision of the method was high, with relative standard deviations below 5%. Concentrations of E2 in wastewater varied from 0.77 to 6.4 ng/L, while concentrations of E1 were greater (1.6-18 ng/L).

Chromatography, Affinity↗

Stabilization of ascorbic acid in human plasma, and its liquid-chromatographic measurement.

We describe two independent HPLC procedures for the rapid, accurate analysis for ascorbic acid in human plasma. No sample extraction or phase separation is required. We also describe a procedure for preparing a human plasma reference material for use in clinical laboratory analysis for ascorbic acid. The ascorbic acid in plasma can be determined in 15 min, with as little as 50 microL of sample. Analytical recoveries are near 100% with direct injection of deproteinized plasma. Extensive stability data under several conditions, with dithiothreitol as a preservative (antioxidant), indicate that ascorbic acid remains stable in stored plasma for as long as 57 weeks. CVs for round-robin analysis of 11 normal human blood samples by two independent methods were between 0.1% and 5.3%. These clinical samples appear to be stable for at least 50 days under the described conditions of stabilization and sample treatment. Finally, because ascorbic acid prepared by the described procedures is stable at room temperature for at least 18 h, these methods can be readily adapted to clinical laboratory automation at room temperature.

Ascorbic Acid↗

Simultaneous analysis of retinol, all-trans- and 13-cis-retinoic acid and 13-cis-4-oxoretinoic acid in plasma by liquid chromatography using on-column concentration after single-phase fluid extraction.

A reversed-phase high-performance liquid chromatographic method for the simultaneous analysis of retinol, all-trans-retinoic acid, 13-cis-retinoic acid and 13-cis-4-oxoretinoic acid in human plasma and cell culture medium is described. Sample preparation involves precipitation of proteins and extraction of retinoids with 60% acetonitrile. After centrifugation, the acetonitrile content of the supernatant is reduced to 45%, allowing on-column concentration of analytes. Injection volumes up to 2.0 ml (equivalent to 0.525 ml of sample) can be used without compromising chromatographic resolution of all-trans-retinoic acid and 13-cis-retinoic acid. Retinoids were stable in this extract and showed no isomerization when stored in the dark in a cooled autosampler, allowing automated analysis of large series of samples. Recoveries from spiked plasma samples were between 95 and 103%. Although no internal standard was used, the inter-assay precision for all retinoids was better than 6% and 4% at concentrations of 30 nM and 100 nM, respectively. The method is a valuable tool for the study of cellular metabolism of all-trans-retinoic acid, as polar metabolites of this compound can be detected with high sensitivity in cell culture media.

Chromatography, High Pressure Liquid↗

Comparative study of the GenePath group 4 reagent system and other CHEF systems for karyotype analysis of Candida spp.

The commercial GenePath Group 4 Reagent Candida kit (BioRad), designed to simplify the electrophoretic karyotyping of Candida spp. was evaluated against several other established contour-clamped homogeneous electric field (CHEF) systems for Candida. This comparison allowed assessment of both the GenePath system and the other CHEF systems regarding the sources of technical variability of the assays and variation in karyotypic analysis. The GenePath system appeared to be a simple, rapid and reliable tool for karyotyping of Candida spp. with a discriminatory power comparable with established CHEF systems. The evaluation showed that the variability of the CHEF systems for subtyping of Candida is largely a function of technical variabilities in the assay system (reagents, sample preparation, running conditions, and test performance), and of analytical variabilities due to imprecision or observers bias. Lack of standardization of these factors may contribute to variability among investigators and have an impact on the ultimate conclusions of an epidemiological study using CHEF methods.

Candida↗

Evaluation of denuder sampling for a mixture of three common gaseous diisocyanates.

A denuder sampler has been evaluated for a mixture of three gaseous diisocyanates, i.e. toluene diisocyanate (TDI), hexamethylene diisocyanate (HDI) and isophorone diisocyanate (IPDI). Sampling was performed at a total concentration of diisocyanates close to the Swedish occupational exposure limit (OEL), which is 10 ppbv (69-92 microg m(-3)), for a 5-min period. The denuder tube was coated with a chemosorptive stationary phase consisting of SE-30 (polydimethylsiloxane) and the derivatising reagent dibutylamine (DBA). It was shown that the denuder has a collection efficiency for HDI and IPDI comparable to that of an impinger method, while sampling of TDI resulted in an 8% lower concentration. Both short-term (15 min) and long-term (8 h) sampling periods were shown to yield reproducible results. For 8-h measurements, a sampling flow rate of 5 mL min(-1) was shown to be suitable for the investigated concentration range, i.e. 10-100 ppbv (69-921 microg m(-3)). A flow rate of 25 mL min(-1) or higher resulted in breakthrough after 8 h due to chromatography of the compounds in the adsorbent. The limit of detection (LOD) for the air sampling method is nearly 500 times lower than the OEL. The denuder tubes can be prepared at least 10 days prior to sampling without degradation of performance. Furthermore, they can be stored up to 6 days in a freezer after sampling without significant loss of analytes.

Journal Article↗

Determination of penconazole on personal protection equipment after field applications.

A simple analytical method, validated in-house and intra-laboratory, has been developed for the determination of penconazole on personal protection equipment (PPE) used by operators during field applications of Topas 20EW. The analytical determination of penconazole was performed by GC-ECD. Sample preparation was based on a liquid extraction procedure. The possible effect of different personal protection equipment matrices on the analytical determination of penconazole was studied and evaluated with regression analysis. No evidence of significant (at 95% CI level) effect was observed at several fortification levels. The percentage recovery of penconazole from the different PPE was in the range 59-100% with adequate correlation with the level of fortification (r2>0.99). The RSD% was in the range of 1-15% and the LOD and LOQ for penconazole were 0.84 and 2.5 ng mL(-1), respectively.

Calibration↗

Rapid and sensitive determination of pyrethroids indoors using active sampling followed by ultrasound-assisted solvent extraction and gas chromatography.

A fast and simple method to analyze pyrethroids as well as other components of frequently used domestic insecticide preparations in indoor air is presented. The proposed method, based on sampling with an adsorbent followed by ultrasound-assisted solvent extraction, was developed with the aim to simplify the traditional extraction methodologies applied up to date to determine pesticides in air. The analytes were retained on a very small amount of adsorbent, which allowed using solely 1 mL of solvent for desorption. The quantification was performed by gas chromatography with microelectron-capture detection (GC-muECD) and gas chromatography coupled to mass spectrometry (GC-MS). The influence of main factors involved in the ultrasound-assisted solvent extraction step (type of adsorbent and type of solvent, solvent volume and extraction time) was studied using an experimental design approach to account for possible factor interactions. The sampling step was studied for two adsorbents (Tenax TA and Florisil), finding that 1 m(3) air could be sampled without losses of analytes. In this way, the analysis of pyrethroids in air by the proposed method could be carried out within a total time shorter than an hour, including sampling. Linearity was demonstrated in a wide concentration range. Efficiency of the total sampling-extraction process was studied at several concentration levels (2, 10, 100 and 1000 ng/m(3)), obtaining quantitative recoveries for all compounds, with good precision (RSD < 10%). Method detection limits were below 1 ng/m(3) in air when GC-muECD was employed, and about one order of magnitude higher for GC-MS. In addition, the proposed method was applied to real samples collected in contaminated closed rooms, in which some of the target compounds were determined.

Air Pollution, Indoor↗

Improved high-performance liquid chromatographic analysis with double detection system for L-dopa, its metabolites and carbidopa in plasma of parkinsonian patients under L-dopa therapy.

An analytical method is described for measuring L-3,4-dihydroxyphenylalanine (L-DOPA), 3-O-methyl-DOPA, dihydroxyphenylacetic acid, free catecholamines and the peripheral DOPA decarboxylase inhibitor, carbidopa, in plasma samples of Parkinsonian patients by using high-performance liquid chromatography. A sample preparation method is presented for the isolation of the catecholamines and L-DOPA with its metabolites. Catecholamines are extracted by weak cation exchange on small columns and subsequent adsorption on alumina. L-DOPA, 3-O-methyl-DOPA, dihydroxyphenylacetic acid and carbidopa contained in the column effluents are directly injected in the chromatographic system. The eluates are separated on a reversed-phase column, monitored by both a coulometric electrochemical detector and a fluorescence detector, connected in series. Chromatographic peaks were identified on the basis of their retentions and response ratios of the two detectors. Two examples are presented of therapeutic drug monitoring in Parkinsonian patients treated with oral doses and continuous intravenous infusion of L-DOPA.

Carbidopa↗

Programmed temperature vaporiser-based injection in capillary gas chromatography.

The application of programmed temperature vaporisation (PTV) in capillary gas chromatographic analysis is reviewed. The development of the different strategies as well as the state of the art are described. As the analytes are normally enriched in the PTV insert, the quoted papers are subdivided depending on whether the enrichment was carried out from organic solvents, from water or from gaseous media. Furthermore, the possibilities of PTVs for on-line coupling with sample preparation methods or other separation techniques and their use as thermoreactors are mentioned.

Chromatography, Gas↗

Indirect monitoring of internal exposure in the decommissioning of a nuclear power plant in Spain.

The experimental procedure used for the indirect measurement of internal exposure of workers involved in the first step of the decontamination of a nuclear power plant which is being decommissioned is presented. The establishment of decontamination and decommissioning programs is currently in progress at the nuclear power plant and monitoring procedures to assess workers' exposure have also been implemented. Due to the presence of transuranics, the monitoring program includes the analysis of excreta samples. An analytical method for the determination of plutonium (Pu) and americum (Am) in urine samples was developed. The radiochemical separation is based on the coprecipitation of transuranics and sequential isolation of Pu and Am by anion exchange and extraction chromatography. Finally, electrodeposited sources are prepared and counted by alpha-spectrometry.

Americium↗

Sensitive and specific liquid chromatographic-tandem mass spectrometric assay for dihydroergotamine and its major metabolite in human plasma.

A sensitive and specific procedure for the simultaneous determination of dihydroergotamine (DHE) and its 8'-hydroxylated metabolite (8'-OH-DHE) in human plasma was developed and validated. The analytes were extracted from plasma samples by liquid-liquid extraction, separated through a Zorbax C18 column (50x2.1 mm I.D.) and detected by tandem mass spectrometry with an electrospray ionization interface. Caroverine was used as the internal standard. The method has a lower limit of quantitation (LOQ) of 10.0 and 11.0 pg/ml for DHE and 8'-OH-DHE, respectively. The intra- and inter-run precision was measured to be below 9.1% for both DHE and 8'-OH-DHE. The inter-run accuracy was within 4% for the analytes. The overall extraction recoveries of DHE and 8'-OH-DHE were determined to be about 58 and 52% on average, respectively. The chromatographic run time was approximately 2.5 min. More than 120 samples could be assayed daily with this method, including sample preparation, data acquisition and processing. The method developed was successfully used to investigate plasma concentrations of DHE and 8'-OH-DHE in a pharmacokinetic study of volunteers who received DHE orally.

Chromatography, Liquid↗