Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Accuracy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57Linked to original sources

Safety and accuracy of transarticular screw fixation C1-C2 using an aiming device. An anatomic study.

STUDY DESIGN: In this anatomic study, the safety and accuracy of C1-C2 transarticular screw placement was tested in a normal anatomic situation in cadaver specimens using a specially designed aiming device. OBJECTIVES: To assess the safety and accuracy of transarticular screw placement using the technique described by Magerl and a specially designed aiming device. SUMMARY OF BACKGROUND DATA: Transarticular C1-C2 screw fixation has been shown to be biomechanically superior to posterior C1-C2 wiring techniques. Several clinical series have been reported in the literature. However, no previous study assessing the accuracy or safety of this technique has been published. Structures at risk are the vertebral arteries, spinal canal, and the occiput-C1 joint. METHODS: Five frozen human cadaveric specimens were thawed and instrumented with 10 C1-C2 transarticular screws, according to the technique described by Magerl but using a specially designed aiming device described by the senior author (Jeanneret). After screw placement, the accuracy of screw positioning and the distance of the screws from the spinal canal, vertebral arteries, and atlanto-occipital joint were determined by anatomic dissection and radiographic analysis. RESULTS: The structure at greatest risk was the atlanto-occipital joint, with one screw found to be damaging the joint. Vertebral artery or spinal canal penetration was not observed in any of the specimens. Screw length averaged 45 mm and, with proper length, the screw tip was found to be located approximately 7.5 mm behind the anterior tubercle of C1 on lateral radiographs. CONCLUSIONS: This anatomic study demonstrates that C1-C2 transarticular screw fixation can be performed safely in a normal anatomic situation by surgeons who are familiar with the pertinent anatomy. The aiming device allowed safe instrumentation in all patients. In case of an irregular anatomic situation (e.g., congenital abnormalities or trauma), computed tomographic scan with sagittal reconstruction is recommended-in particular, to obtain information about the course of the vertebral artery.

Axis, Cervical Vertebra↗

The test of Lasègue: systematic review of the accuracy in diagnosing herniated discs.

STUDY DESIGN: A systematic review of the literature including statistical meta-analysis. OBJECTIVES: To evaluate published methods of the test of Lasègue or straight leg raising test and the cross straight leg raising test by using a recently developed criteria list and to summarize and explore reasons for variation in diagnostic accuracy. SUMMARY OF BACKGROUND DATA: Little evidence exists on the diagnostic accuracy of the widely used straight leg raising test and the cross straight leg raising test in diagnosing herniated discs in patients with low back pain. METHODS: MEDLINE and EMBASE searches up to 1997 showed 17 diagnostic publications evaluating the straight leg raising test with surgery as reference standard. Quality of methods was assessed with a specific checklist. Eleven studies were selected for statistical pooling. Sources of variation and heterogeneity were studied by meta-regression of the diagnostic odds ratio. RESULTS: All studies were surgical case-series at nonprimary care level. Verification-bias was obvious in one study. Pooled sensitivity for straight leg raising test was 0. 91 (95% CI 0.82-0.94), pooled specificity 0.26 (95% CI 0.16-0.38). Pooled diagnostic odds ratio was 3.74 (95% CI 1.2-11.4). Discriminative power was lower in recent studies, in studies with only inclusion of primary hernias, and with blind assessment of both the index-test (straight leg raising test) and the reference (surgery). For the cross straight leg raising test pooled sensitivity was 0.29 (95% CI 0.24-0.34), pooled specificity was 0.88 (95% CI 0.86-0.90), and the pooled diagnostic odds ratio 4.39 (95% CI 0.74-25.9). CONCLUSIONS: The diagnostic accuracy of the straight leg raising test is limited by its low specificity. Discriminative power decreased with a more valid design, a more homogenous case-mix, and year of publication. Although the studies may reflect everyday clinical practice, they do not enable a valid evaluation of the diagnostic accuracy of both tests. Diagnostic research should evaluate the validity of the complete diagnostic process and study the evidence of the added value of the different tests used. [Key words: sensitivity, specificity, diagnosis, meta-analysis, test of Lasègue, straight leg raising test]

Adult↗

Effects of drugs of abuse on response accuracy and bias under a delayed matching-to-sample procedure in squirrel monkeys.

The effects on memory of drugs of abuse from several pharmacological classes were examined in four adult male squirrel monkeys responding under a delayed matching-to-sample schedule of food presentation. Subjects were required to emit 20 responses on a sample key transilluminated by either a constant white or a flashing blue light. The twentieth response initiated a 3-second delay followed by presentation of two comparison stimuli. If a response was made to the key that matched the sample stimulus (correct match), a single food pellet (97 mg) was delivered. Pentobarbital (0.32-10 mg/kg), diazepam (0.1-5.6 mg/kg), phencyclidine (0.01-0.32 mg/kg) and cocaine (0.1-3.2 mg/kg) dose-dependently reduced accuracy of matching performance towards chance levels. Amphetamine (0.01-1.0 mg/kg) resulted in a small, but statistically significant, reduction in accuracy at a dose of 0.56 mg/kg, while 1.0 mg/kg completely suppressed responding. Analyses indicated that pentobarbital, diazepam and cocaine produced either position or color biases in responding, and in some cases these biases in responding were associated with decreases in accuracy. No such response biases were observed with phencyclidine or D-amphetamine. These results suggest that drug effects on working memory performance can, in some cases, be the result of non-mnemonic processes. Thus, they illustrate the importance of examining behavioral endpoints in addition to task accuracy when interpreting drug effects on working memory in laboratory animals.

Animals↗

Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement.

Malposition of the acetabular component during hip arthroplasty increases the occurrence of impingement, reduces range of motion, and increases the risk of dislocation and long-term wear. To prevent malpositioned hip implants, an increasing number of computer-assisted orthopaedic systems have been described, but their accuracy is not well established. The purpose of this study was to determine the reproducibility and accuracy of conventional versus computer-assisted techniques for positioning the acetabular component in total hip arthroplasty. Using a lateral approach, 150 cups were placed by 10 surgeons in 10 identical plastic pelvis models (freehand, with a mechanical guide, using computer assistance). Conditions for cup implantations were made to mimic the operating room situation. Preoperative planning was done from a computed tomography scan. The accuracy of cup abduction and anteversion was assessed with an electromagnetic system. Freehand placement revealed a mean accuracy of cup anteversion and abduction of 10 degrees and 3.5 degrees, respectively (maximum error, 35 degrees). With the cup positioner, these angles measured 8 degrees and 4 degrees (maximum error, 29.8 degrees), respectively, and using computer assistance, 1.5 degrees and 2.5 degrees degrees (maximum error, 8 degrees), respectively. Computer-assisted cup placement was an accurate and reproducible technique for total hip arthroplasty. It was more accurate than traditional methods of cup positioning.

Arthroplasty, Replacement, Knee↗

Qualitative and quantitative accuracy of CAOS in a standardized in vitro spine model.

Pedicle breach with screw implantation is relatively common. For clinical application of computer-assisted orthopaedic surgery, it is important to quantitatively know the accuracy and localization of any guidance modality. We ascertained the accuracy of computed tomography and C-arm-based navigated drilling versus conventional fluoroscopy using an artificial thoracic and lumbar spine model. The 3.2-mm diameter transpedicle drilling target was the center of a 4-mm steel ball fixed in the anterior left pedicle axis. After drilling, we used computed tomography to verify the position of the steel ball and the canal and visually explored for cortex perforation. Quantitative vector calculation showed computed tomography-based navigation had the greatest accuracy (median, d(thoracic) = 1.4 mm; median, d(lumbar) = 1.8 mm) followed by C-arm navigation (median, d(thoracic) = 2.6 mm; median, d(lumbar) = 2 mm) and the conventional procedure (median, d(thoracic) = 2.2 mm; median, d(lumbar) = 2.7 mm). Visual examination showed a decreased perforation rate in navigated drillings. We found no correlation between pedicle breaches and inaccurate drilling. The data suggest computer-assisted orthopaedic surgery cannot provide sub-millimeter accuracy, and complete prevention of pedicle perforation is not realistic.

Fluoroscopy↗

Accuracy of cut-off acetabular reamers for minimally invasive THA.

Cut-off reamers have been introduced for minimally invasive hip replacement to make reamer insertion through the small incision easier. However, the accuracy of cut-off reamers in comparison to traditional hemispherical reamers has not been documented. We reamed four human cadaveric hips using a cut-off reamer and three hips using a standard reamer. We started with smallest size reamer to remove subchondral bone, and the size was progressively increased until breaching the acetabular floor. We performed computed tomography scans for each reamer size to digitally determine the true dimensions and sphericity of the reamed acetabula. The cut-off reamers breached the acetabulum at a smaller size than with a standard reamer in two specimens, and at the same size as the standard reamer in one specimen. The accuracy of each reamer size was determined by quantifying the percentage of the reamed acetabular surface that was within 0.5 mm of the hemispherical reamer size. The average accuracy of the cut-off reamers was 70% compared with 81% for the standard reamers. The cut-off acetabular reamers showed a trend toward decreased accuracy that may be attributable to a tendency of the reamer to wobble in use.

Acetabulum↗

Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: a cadaver study.

STUDY DESIGN: A surgical simulation study in human cadaver spine specimens was conducted to evaluate the accuracy of thoracic vertebral body screw placement using four different intraoperative imaging techniques. OBJECTIVE: To compare standard fluoroscopy, fluoroscopy-based image guidance with two different referencing methods, and computed tomography-based image guidance by the measuring the time required for screw placement, the radiation exposure to specimen and surgeon, and the accuracy of screw position in the thoracic spine. SUMMARY OF BACKGROUND DATA: Image guidance provides additional anatomic information to the surgeon and may improve safety of technically difficult surgical procedures. The placement of screws in the thoracic spine is a technically demanding procedure in which inaccurate screw positioning places the spinal cord, nerve roots, and paraspinal structures such as the aorta and pleural space at risk for injury. Image-guided surgery may improve the accuracy of thoracic screw placement. METHODS: Using four different intraoperative imaging methods, two experienced surgeons placed 337 vertebral body screws through the pedicles of thoracic vertebrae in 20 human cadaver thoracic spine specimens. The specimens then were examined with radiographs, computed tomography, and anatomic dissection to determine screw position. Measurements included procedure setup and screw insertion time, radiation exposure to the specimen, the surgeon's hand, the surgeon's body, frequency, direction, and magnitude of screw perforation through the cortical margins of thoracic vertebrae. RESULTS: As compared with surgery using standard fluoroscopy, fluoroscopy-based image guidance that uses multiple reference marks and computed tomography-based image guidance improves the accuracy of thoracic vertebral body screws, but increases the time required for screw placement and the specimen radiation exposure. Exposure to radiation is minimal at the surgeon's body level and dependent on surgical technique at the surgeon's hand level. Screw perforation occurs most frequently in the lateral direction. CONCLUSIONS: Fluoroscopy-based image guidance that uses only a single reference marker for the entire thoracic spine is highly inaccurate and unsafe. Systems with registration based on the instrumented vertebrae provide more accurate placement of thoracic vertebral body screws than standard fluoroscopy, but expose the patient to more radiation and require more time for screw insertion.

Adult↗

Accuracy and efficacy of thoracic pedicle screws in curves more than 90 degrees.

STUDY DESIGN: Retrospective study of large-magnitude thoracic curves (> or =90 degrees ) treated with pedicle screw constructs. OBJECTIVE: To evaluate the results of pedicle screw constructs for thoracic curves > or = 90 degrees in terms of sagittal and coronal correction/efficacy, as well as accuracy and safety of thoracic pedicle screw placement. SUMMARY OF BACKGROUND DATA: Thoracic pedicle screw constructs continue to become increasingly more common; however, the debate continues about the safety and efficacy of these constructs because of their perceived increased risk of neurologic injury and the increased cost of spinal instrumentation. METHODS: Since 1998, all patients with adolescent idiopathic scoliosis, or adult progression of adolescent idiopathic scoliosis, a thoracic curve > or = 90 degrees and a minimum 2-year follow-up who were treated with pedicle screw constructs were included in this study. Standing anteroposterior (or posteroanterior), lateral and bending preoperative radiographs, and anteroposterior (or posteroanterior) and lateral postoperative radiographs were evaluated for curve magnitude, flexibility, and postoperative correction to assess the efficacy of these constructs in the immediate postoperative period and at latest follow-up. Postoperative CT scans were evaluated for screw accuracy using established 2-mm increments (intrapedicular, 0-2 mm breach, 2-4 mm breach, > 4 mm breach). Preoperative plans were also reviewed to evaluate the ability to place a pedicle screw at each planned level in these large-magnitude curves. RESULTS: Twenty patients with thoracic curves > or = 90 degrees and an average follow-up of 3.3 years (range, 2.0-5.2 years) were included in the study. All patients underwent a posterior spinal fusion with a pedicle screw only construct. The average preoperative main thoracic curve measured 100.2 degrees (range, 90 degrees -133 degrees ), with an average side-bender of 71.6 degrees (29% flexibility). The average postoperative main thoracic curve was 32.3 degrees (68% correction). A total of 352 thoracic screws were placed in the 20 cases (17.6 screws/case). Screw accuracy (either intrapedicular or <2 mm breach) was 96.3% (339 of 352 screws) by postoperative CT scanning. Ten screws were considered to have a breach between 2 and 4 mm (3 medial, 7 lateral), while three screws were > 4 mm (2 medial, 1 lateral). The two medial screws were the only placed screws that were removed (0.57%). Overall, 94% of planned screws (352 of 374 screws) were placed according to the preoperative plan. There were no incidences of screw or instrumentation failure. Of note, there was a temporary decrease in motor-evoked potentials during curve correction in 2 cases; however, there were no identifiable neurologic complications. CONCLUSIONS: Thoracic pedicle screw constructs can be safely used for large-magnitude curves. Curve correction (68%) is powerful for these curves, which are stiff and difficult to manage. Correction should be performed carefully with consideration given to convex compression for cases with concomitant hyperkyphosis for these "at risk" spinal cords. Screw accuracy (96.3%) was excellent in this review. The authors found that screws can consistently be placed according to the preoperative plan even in these large-magnitude curves.

Adolescent↗

A prospective, randomized, multicenter Food and Drug Administration investigational device exemption study of lumbar total disc replacement with the CHARITE artificial disc versus lumbar fusion: part II: evaluation of radiographic outcomes and correlation of surgical technique accuracy with clinical outcomes.

STUDY DESIGN: A prospective, randomized, multicenter, Food and Drug Administration-regulated, investigational device exemption clinical trial. OBJECTIVES: To compare the safety and effectiveness of lumbar total disc replacement (TDR) with the CHARITE artificial disc (DePuy Spine, Raynham, MA) to anterior lumbar interbody fusion for the treatment of single-level degenerative disc disease from L4-S1 unresponsive to nonoperative treatment. In addition, to evaluate the radiographic outcomes of lumbar artificial disc replacement at either L4-L5 or L5-S1 with the CHARITE artificial disc as compared to anterior lumbar interbody fusion with cylindrical cages and iliac crest bone graft; and to determine if a correlation exists between clinical outcomes and surgical accuracy of TDR placement within the disc space. SUMMARY OF BACKGROUND DATA: Prior investigators have reported excellent radiographic results with the CHARITE artificial disc for the treatment of lumbar degenerative disc disease. These encouraging results are the product of retrospective reviews without a control. Very few studies have reported on the segmental motion of an intervertebral level implanted with an artificial disc, and no studies have reported a correlation of radiographic and clinical outcomes. METHODS: A prospective, randomized, multicenter, US Food and Drug Administration, investigational device exemption study with 24-month follow-up was performed at 14 centers throughout the United States. A total of 304 subjects were randomized in a 2:1 ratio, with 205 in the investigational group (TDR with the CHARITE artificial disc) and 99 in the control group (anterior lumbar interbody fusion with BAK cages and iliac crest bone graft). A total of 71 TDR training cases were performed (up to 5 at each site) before randomization beginning at each site. Plain radiographs were analyzed for each subject in both groups regarding range of motion (ROM) in flexion/extension, restoration of disc space height, and subsidence. Prosthesis placement in the coronal and midsagittal planes was analyzed for the 276 patients with TDR. Correlations were performed between prosthesis placement and clinical outcomes. RESULTS: Patients in the investigational group had a 13.6% mean increase, and those in the control group an 82.5% decrease in mean flexion/extension ROM at 24 months postoperatively compared to baseline. Patients in the investigational group had significantly better restoration of disc height than the control group (P < 0.05). There was significantly less subsidence in the investigational group compared to the control group (P < 0.05). The surgical technical accuracy of CHARITE artificial disc placement was divided into 3 groups: I, ideal (83%); II, suboptimal (11%); and III, poor (6%), and correlated with clinical outcomes. The flexion/extension ROM and prosthesis function improved with the surgical technical accuracy of radiographic placement (P = 0.003). CONCLUSIONS: Preoperative ROM in flexion/extension was restored and maintained in patients receiving a TDR. TDR with the CHARITE artificial disc resulted in significantly better restoration of disc space height, and significantly less subsidence than anterior interbody fusion with BAK cages. Clinical outcomes and flexion/extension ROM correlated with surgical technical accuracy of CHARITE artificial disc placement. In the majority of cases, placement of the CHARITE artificial disc was ideal.

Adult↗

Accuracy of computed tomography in assessing thoracic pedicle screw malposition.

OBJECTIVE: Transpedicular instrumentation of the thoracic spine is potentially dangerous because of the close proximity of vital structures and the morphologic variability seen. Computed tomography has become the gold standard in evaluating the position of thoracic pedicle screws in vivo. Unfortunately, despite its common use, the accuracy of computed tomography has not been adequately investigated. The objective of this work was to evaluate the accuracy of computed tomography in evaluating the position of thoracic pedicle screws. METHODS: One hundred ninety-four thoracic pedicles in nine cadaveric specimens were instrumented and evaluated postoperatively with computed tomography and open dissection. Computed tomography films were assessed by three blinded observers who noted the position of each pedicle screw on two separate occasions. These data were subsequently compared with the open dissection data. RESULTS: Computed tomography was found to be 76 +/- 16% sensitive and 75 +/- 13% specific when compared with open dissection. Overall accuracy was 76 +/- 8%. Intraobserver accuracy was 79 +/- 5% in assessing thoracic pedicle screws by computed tomography. Fair to moderate degree of agreement was demonstrated for both interobserver and intraobserver data using kappa values. CONCLUSIONS: Computed tomography was found to be relatively insensitive in assessing thoracic pedicle screw position. In the face of postoperative complications, surgical exploration and hardware removal may still be necessary despite negative computed tomography.

Bone Screws↗

Accuracy over space and time of computer-assisted fluoroscopic navigation in the lumbar spine in vivo.

OBJECTIVE: The integration of digital image-guided surgical navigation with C-arm fluoroscopy, known as virtual fluoroscopy (VF), has been shown to enhance the safety of spine surgery in vitro. Few clinical studies have assessed the accuracy of VF during actual spinal surgery, and no studies have investigated variations in accuracy over the course of a series of measurements obtained during operative cases. We sought to study the intraoperative accuracy of VF over time and space during lumbar pedicle screw placement in human patients. METHODS: Fluoroscopic images of the lumbar spine were obtained, calibrated, and saved to the Stealth Station (FluoroNav) on seven patients undergoing lumbar fusion surgery. The tracking arc was attached to an exposed lumbar spinous process, which was designated the index level. With use of anatomic surface irregularities in the laminae and spinous processes, several points were identified and registered on three different vertebrae directly adjacent to the index level vertebra. Every 15 minutes, throughout the operative case, the probe was brought to each point and the apparent distance from the original location recorded (as measured by the FluoroNav system). Measurements were collected from three vertebral levels adjacent to the index level over a time course of 120 minutes during the operation. RESULTS: At the index, index +1, index +2, and index +3 levels, 89%, 81%, 92%, and 64% of measurements were within <2 mm, whereas 97%, 96%, 97%, and 91% were within <3 mm, respectively. At 15, 30, 45, 60, 75, 90, 105, and 120 minutes, 96%, 89%, 85%, 61%, 85%, 90%, 93%, and 50% of measurements were within <2 mm, whereas 100%, 93%, 100%, 83%, 100%, 90%, 100%, and 100% of measurements were within <3 mm, respectively. The error in millimeters tended to increase as the distance from the index level increased (R = 0.19, P < 0.05) and as operative time increased (R = 0.26, P < 0.01). Calibration studies of intraoperative VF (IoVF) in the lumbar spine documented a reasonable degree of accuracy. The majority of sequential measurements obtained during IoVF in the lumbar spine were within an error range of <3 mm. CONCLUSIONS: Our results suggest that the use of VF is a reliable method of verifying the use of anatomic and/or radiographic landmarks for guidance during lumbar pedicle screw placement.

Adult↗

Reliability and accuracy of Sequential Organ Failure Assessment (SOFA) scoring.

OBJECTIVE: The Sequential Organ Failure Assessment (SOFA) score was developed to quantify the severity of patients' illness, based on the degree of organ dysfunction. This study aimed to evaluate the accuracy and the reliability of SOFA scoring. DESIGN: Prospective study. SETTING: Adult intensive care unit (ICU) in a tertiary academic center. SUBJECTS: Thirty randomly selected patient cases and 20 ICU physicians. MEASUREMENTS AND MAIN RESULTS: Each physician scored 15 patient cases. The intraclass correlation coefficient was .889 for the total SOFA score. The weighted kappa values were moderate (0.552) for the central nervous system, good (0.634) for the respiratory system, and almost perfect (>0.8) for the other organ systems. To assess accuracy, the physicians' scores were compared with a gold standard based on consensus of two experts. The total SOFA score was correct in 53% (n = 158) of the cases. The mean of the absolute deviations of the recorded total SOFA scores from the gold standard total SOFA scores was 0.82. Common causes of errors were inattention, calculation errors, and misinterpretation of scoring rules. CONCLUSIONS: The results of this study indicate that the reliability and the accuracy of SOFA scoring among physicians are good. We advise implementation of additional measures to further improve reliability and accuracy of SOFA scoring.

Coma↗

Accuracy and precision of EyeSys and Orbscan systems on calibrated spherical test surfaces.

BACKGROUND: It is important to know how well the surface topography can be measured with current devices for corneal topographic analysis. There are several applications that need an accurate and precise method to measure corneal shape and variations, such as the effect of contact lens wear and the different refractive surgery techniques. PURPOSE: The aim of this study is to compare the accuracy and reproducibility of the measurement of the central curvature on calibrated steel balls using the EyeSys videokeratoscope and the Orbscan corneal topography system. METHODS: The videokeratoscope (EyeSys Corneal Analysis System 2000, version 3.1) and the Orbscan corneal topography system (Orbscan II version 3.0) were used by four trained investigators to measure a series of five uniform and calibrated test surfaces with known radius of curvature ranging from 6.13 to 9.00 mm. RESULT: No statistically significant difference was found between the videokeratoscope and Orbscan systems in relation to accuracy or precision. The 95% confidence limits showed a close agreement between both instruments. The mean bias was less than +/-0.05 mm for both devices. The precision of the instruments was found to be similar. CONCLUSION: The EyeSys seems to measure more accurately, but the accuracy of the Orbscan was also acceptable, suggesting that both instruments are accurate and precise enough for research and clinical purposes. However, further studies of accuracy and repeatability of topographical measurements on human eyes generated by different topographers are necessary.

Cornea↗

Diagnostic accuracy of 2-[fluorine-18]fluro-2-deoxy-D-glucose positron emission tomography imaging in nonsquamous tumors of the head and neck.

PURPOSE: To evaluate the diagnostic accuracy of 2-[fluorine-18]fluro-2-deoxy-D-glucose positron emission tomography (FDG-PET) for detecting nonsquamous tumors of the extracranial head and neck (NSTHN). MATERIALS AND METHODS: The records of all patients with suspected or proven NSTHN undergoing PET imaging in our institution over a 12-year period were reviewed. Forty-four patients (24 males and 20 females; age range, 6-81 years; mean age, 51.2 years) were classified into 3 main groups: thyroid tumors (n = 19), salivary gland tumors (n = 7), and miscellaneous lesions (n = 18). The PET findings for each individual group with respect to the primary site, cervical nodal and distant metastases, were correlated with histopathology or follow-up (2-year minimum) RESULTS: The overall diagnostic accuracy of FDG-PET for all NSTHN was 86%, However, the diagnostic accuracy varied for the histologic subtype (thyroid, salivary, miscellaneous) and the area being evaluated (primary site, nodal metastases, distant metastases). CONCLUSION: There is variable diagnostic accuracy of FDG-PET in detecting different histologic subtypes of NSTHN. This information should be taken into consideration when considering PET for evaluation of NSTHN.

Adolescent↗

Sentinel node biopsy for early-stage melanoma: accuracy and morbidity in MSLT-I, an international multicenter trial.

OBJECTIVE: The objective of this study was to evaluate, in an international multicenter phase III trial, the accuracy, use, and morbidity of intraoperative lymphatic mapping and sentinel node biopsy (LM/SNB) for staging the regional nodal basin of patients with early-stage melanoma. SUMMARY BACKGROUND DATA: Since our introduction of LM/SNB in 1990, this technique has been widely adopted and has become part of the American Joint Committee on Cancer (AJCC) staging system. Eleven years ago, the authors began the international Multicenter Selective Lymphadenectomy Trial (MSLT-I) to compare 2 treatment approaches: wide excision (WE) plus LM/SNB with immediate complete lymphadenectomy (CLND) for sentinel node (SN) metastases, and WE plus postoperative observation with CLND delayed until the subsequent development of clinically evident nodal metastases. METHODS: After each center achieved 85% accuracy of SN identification during a 30-case learning phase, patients with primary cutaneous melanoma (> or =1 mm with Clark level > or =III, or any thickness with Clark level > or =IV) were randomly assigned in a 4:6 ratio to WE plus observation (WEO) with delayed CLND for nodal recurrence, or to WE plus LM/SNB with immediate CLND for SN metastasis. The accuracy of LM/SNB was determined by comparing the rates of SN identification and the incidence of SN metastases in the LM/SNB group versus the subsequent development of nodal metastases in the regional nodal basin of those patients with tumor-negative SNs. Early morbidity of LM/SNB was evaluated by comparing complication rates between the 2 treatment groups. Trial accrual was completed on March 31, 2002, after enrollment of 2001 patients. RESULTS: Initial SN identification rate was 95.3% overall: 99.3% for the groin, 95.3% for the axilla, and 84.5% for the neck basins. The rate of false-negative LM/SNB during the trial phase, as measured by nodal recurrence in a tumor-negative dissected SN basin, decreased with increasing case volume at each center: 10.3% for the first 25 cases versus 5.2% after 25 cases. There were no operative mortalities. The low (10.1%) complication rate after LM/SNB increased to 37.2% with the addition of CLND; CLND also increased the severity of complications. CONCLUSIONS: LM/SNB is a safe, low-morbidity procedure for staging the regional nodal basin in early melanoma. Even after a 30-case learning phase and 25 additional LM/SNB cases, the accuracy of LM/SNB continues to increase with a center's experience. LM/SNB should become standard care for staging the regional lymph nodes of patients with primary cutaneous melanoma.

Adolescent↗

Noise, cost and speed-accuracy trade-offs: decision-making in a decentralized system.

Many natural and artificial decision-making systems face decision problems where there is an inherent compromise between two or more objectives. One such common compromise is between the speed and accuracy of a decision. The ability to exploit the characteristics of a decision problem in order to vary between the extremes of making maximally rapid, or maximally accurate decisions, is a useful property of such systems. Colonies of the ant Temnothorax albipennis (formerly Leptothorax albipennis) are a paradigmatic decentralized decision-making system, and have been shown flexibly to compromise accuracy for speed when making decisions during house-hunting. During emigration, a colony must typically evaluate and choose between several possible alternative new nest sites of differing quality. In this paper, we examine this speed-accuracy trade-off through modelling, and conclude that noise and time-cost of assessing alternative choices are likely to be significant for T. albipennis. Noise and cost of such assessments are likely to mean that T. albipennis' decision-making mechanism is Pareto-optimal in one crucial regard; increasing the willingness of individuals to change their decisions cannot improve collective accuracy overall without impairing speed. We propose that a decentralized control algorithm based on this emigration behaviour may be derived for applications in engineering domains and specify the characteristics of the problems to which it should be suited, based on our new results.

Algorithms↗

The unexplained accuracy of the Lagrange-mesh method.

The Lagrange-mesh method is an approximate variational calculation which resembles a mesh calculation because of the use of a Gauss quadrature. In order to analyze its accuracy, four different Lagrange-mesh calculations based on the zeros of Laguerre polynomials are compared with exact variational calculations based on the corresponding Laguerre basis. The comparison is performed for three solvable radial potentials: the Morse, harmonic-oscillator, and Coulomb potentials. The results show that the accuracies of the energies obtained for different partial waves with the different mesh approximations are very close to the variational accuracy, even in the presence of the centrifugal singularity. The same property holds for the approximate wave functions. This striking accuracy remains unexplained.

Journal Article↗

Accuracy of drug infusion pumps under computer control.

Prototype systems implementing algorithms for automated drug infusions are typically constructed by coupling a microcomputer to a drug infusion pump through a serial communications interface. Infusion rates demanded of the infusion pump in many computed-controlled drug delivery applications are made to change at intervals much shorter than those encountered under routine clinical use. Because the ability of infusion pumps to maintain accurate flow rates during high frequency rate changes has not been documented, the purpose of this study was to validate the volumetric accuracy of three commercially available infusion pumps operating in a demanding computer-controlled application. In independent 2-h evaluations, the infusion rate demanded of each pump changed as often as every 5, 10, or 15 s using an algorithm for computer-controlled pharmacokinetic model-driven intravenous infusion. Accuracy of the infusion devices was determined gravimetrically. At all measurement times, each of the infusion pumps was accurate to within approximately +/- 5% of the expected volumetric output under each of the infusion rate intervals tested. Flow rate accuracy of +/- 5% is equal to the nominal expected accuracy of these infusion pumps in conventional clinical use.

Algorithms↗