Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AIR CONDITIONING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,027 records · Page 57Linked to original sources

[Determination of subanesthetic concentrations of halothane in the environment of operating and recovery rooms].

Concentrations of halothane in parts per million (ppm) in the air were determined during 4 days in the operating rooms and the recovery room of pediatric surgery during the course of surgical anesthesia by inhalation. The operating rooms did not have an anesthetic gas scavenging system. Eighteen samples of air were taken by passive diffusion in sampling tubes of activated charcoal (mode Dräger Orsa 5). The samples were analysed by gas chromatography). We found concentrations between 4.7 ppm and 34.2 ppm that exceed those considered as admissible that range from 2 to 5 ppm. Our present recommendations to reduce the atmospheric contaminating anesthetic gases are the use of scavenging equipment, air-conditioned rooms and routine inspection and leak detection of apparatus and anesthetic circuits.

Air Pollutants, Occupational↗

[Epidemiology and prevention of pulmonary aspergillosis in patients with hematological malignancies].

Fungal pathogens are recognized as a major and increasing source of life-threatening infections in the immunocompromised host. Infections due to Aspergillus species are among the most common causes of nosocomial pneumonia in patients with hematological malignancies and are associated with an extremely high mortality rate. Aspergillus infections are often related to new building construction and reconstruction, road work, contaminated air conditioning systems,and contaminated potting soils. Endogenic sources include asymptomatic colonization of the respiratory tract and pulmonary aspergilloma. Suitable measures in the patient's environment to protect him from exposure to fungal spores may result in a marked reduction of infection risk. The use of high-efficiency particulate air (HEPA) filtration systems during hospitalization represents the current standard in prevention of invasive pulmonary aspergillosis. This article addresses epidemiological aspects, exposure factors, and preventive aspects with special attention to construction work in hospitals.

Aspergillosis↗

Percutaneous absorption of parathion in vitro in porcine skin: effects of dose, temperature, humidity, and perfusate composition on absorptive flux.

The effect of environmental factors on the percutaneous absorption of parathion in excised porcine skin was assessed in a flow-through diffusion cell system by varying the temperature (T), relative humidity (%RH), perfusate flow rate (F), and composition (porcine serum) at three parathion doses (4, 40, and 400 micrograms/cm2) compared to standard conditions (air temperature = 37 degrees C, perfusate temperature = 37 degrees C, %RH = 60, flow rate = 4 ml/hr, and standard bovine serum albumin medium). Parathion absorption was assessed by monitoring total radiolabeled activity appearing in the perfusate over time. High relative humidity significantly increased parathion penetration, as did two elevated temperature conditions. The effects of flow rate and perfusate composition were variable and dose dependent. In the present studies, lower applied doses appeared to be more sensitive to changes in the environmental conditions studied. These results suggest that these parameters have independent and different degrees of effect on parathion percutaneous absorption. Experimental conditions should be strictly controlled and dose-response studies need to be conducted when evaluating transdermal studies. Finally, if similar effects occur in vivo, the risk assessment calculations on percutaneous absorption should take these parameters into consideration.

Animals↗

[Effect of air pollutants on the organism of the child].

The Institute of Hygiene at Rostock initiated studies in 1980 on schoolchildren (1st to 4th form) in air-hygienically differently affected areas of the former GDR, as well as studies on probationers of the same age in non-polluted areas. The spectrum of methods included besides clinical, sensorial and psycho-diagnostical investigations, also haematological, immunological and pulmonary functions tests. The results indicate that the state of health of children living in industrial areas is impaired. After a recuperating for four weeks under clean air conditions the changed values were normalised and adapted to the values of the non-exposed control group. The long-term effect of the recuperating stay lasts for 9 months.

Air Pollutants, Occupational↗

[Atmospheric air pollution and population mortality in Russian Federation regions].

Regularly published national reports on population health in Russian Federation, based on the results of statistic analyses and the data from hygienic and epidemiological studies, demonstrate associations between exposure to hazardous environmental factors and population morbidity. Research into correlations between exposure to such factors and population health status using extensive databases, makes it possible to obtain statistically significant results and put forward hypotheses for epidemiological studies. The aim of this research was to study the levels and dynamics of population mortality, and atmospheric air condition, as well as correlations between them in regional centers of Russian Federation. The study covers the period from 1985 through 1998.

Adolescent↗

[A humidification system for CPAP therapy in obstructive sleep apnea--evaluation of the effectiveness in changing climatic environmental conditions].

OBJECTIVE: Upper airway dryness is a frequent side-effect of nasal continuous positive airway pressure (nCPAP) therapy in obstructive sleep apnoea syndrome (OSA). In this situation, heated humidification is often used. Therefore, the present study aimed to investigate the humidification performance--defined as the maximum achievable humidity in the tube system of the CPAP device--of a heated humidifier (HH) offered as CPAP accessories, as a function of ambient air conditions (humidity and temperature). PATIENTS AND METHODS: In 30 patients (22 male, 8 female, mean age 56.4 +/- 11.7 years) with OSA undergoing CPAP treatment, temperature (T) and relative humidity (RH) in the CPAP tube system were measured, with and without the HH Somnowave, until a steady state was achieved. At the same time, ambient T and RH in the examination room were recorded. T and RH were used to calculate the absolute humidity (AH). RESULTS: The conditions of the examination room during the examination nights were as follows: T = 21.9 +/- 2.8 degrees C (15.2-26.9), RH 46.5 +/- 11.9% (21.7-69.1) and AH 9.2 +/- 3.2 g/m3 (3.7-16.7). The steady state AH without HH was 9.6 +/- 3.0 g/m3 (4.1-15.4), that with HH (humidification performance) 23.2 +/- 2.8 g/m3 (19.1-29.9) (p < 0.001). CONCLUSION: Under the ambient conditions of humidity and temperature, commonly found in European bedrooms, the HH demonstrate a high humidification performance. Thus, it would appear that the HH is suitable for the treatment of dry upper airways under nCPAP therapy.

Adult↗

Oxygen-induced retinopathy in the newborn rat: morphological and immunohistological findings in animals treated with topical timolol maleate.

Oxygen-induced retinopathy (OIR) similar to that seen in premature infants can be produced in newborn rats by exposure to 80% oxygen for the first 5 days of life, with subsequent recovery for 7 days in a room air environment. Previous studies have shown that the latter phase is associated with degeneration of retinal astrocytes. In the absence of astrocytes, the vascular endothelial growth factor (VEGF) is produced by the neurons of the inner retina. In this study, immunohistochemical methods were used to assess retinal expression of VEGF protein in ratlings exposed to the above protocol, with and without simultaneous treatment with topical timolol maleate. Intraocular pressure (IOP) and arterial pressure were measured. The severity of OIR was also evaluated in retinal flat mounts after India ink perfusion. The mean IOP was 8.25 +/- 0.32 mm Hg in untreated ratlings and 5.15 +/- 0.24 mm Hg in timolol-treated animals. OIR in retinas from the timolol group was less severe than that seen in untreated ratlings. VEGF protein expression was almost completely absent in the latter group. Retinas from timolol-treated animals expressed VEGF protein, though the level was inferior to that found in controls raised under room air conditions. In conclusion, these data seem to indicate that experimental OIR can be attenuated by a reduction of the IOP during and after oxygen supplementation. It is possible that these effects are due to improved ocular perfusion pressure, which would mitigate the hypoxic insult to the retina during the room air recovery period.

Administration, Topical↗

Indirect measurement of water content in an aseptic solid substrate cultivation pilot-scale bioreactor.

A lack of models and sensors for describing and monitoring large-scale solid substrate cultivation (SSC) bioreactors has hampered industrial development and application of this type of process. This study presents an indirect dynamic measurement model for a 200-kg-capacity fixed-bed SSC bioreactor under periodic agitation. Growth of the filamentous fungus Gibberella fujikuroi on wheat bran was used as a case study. Real data were preprocessed using previously reported methodology. The model uses CO2 production rate and inlet air conditions to estimate average bed water content and average bed temperature. The model adequately reproduces the evolution of the average bed water content and can therefore be used as an on-line estimator in pilot-scale SSC bioreactors. To obtain a reasonable fit of the bed temperature, however, inlet air humidity measurements will have to be adjusted with a data reconciliation algorithm. Good estimation of temperature is important for the future design of improved water content estimation using state observers. The model also provides insight into understanding the complex behavior of the dynamic system, which could prove useful when establishing advanced model-based operational and control strategies.

Bioreactors↗

Comparison of cascade impaction and laser diffraction for particle size distribution measurements.

The Andersen cascade impactor (ACI) and laser diffraction (LD) can be correlated at ambient temperature for aqueous drug formulations atomized by Soft Mist inhalers. A comparison of the two particle size determination methods at different conditions (flow rate, relative humidity) was performed. Under well-defined conditions, the faster LD can substitute the time consuming ACI at least for routine tests. The measurements were performed with three different drug formulations. The aerosol was generated by Soft Mist inhalers, and the droplet distributions were measured simultaneously using a laser diffraction analyzer together with the eight-stage Andersen cascade impactor. The simultaneous measurements ensure that aerosol and air conditions are identical for both LD and ACI. In order to measure the scattered laser light intensity of the aerosol passing the induction port, glass windows were fitted to the induction port. The evaporation effect of the aqueous aerosols on the PSD was investigated at ambient humidity and high humidity (RH > 90%). The simultaneous determination of the droplet size distribution leads to a good correlation between the ACI and LD method only if the measurements were performed at RH of >90%. The humidity of the ambient air had the strongest influence on PSD not only for ACI, but also for LD. In our set-up, the almost saturated air prevents aqueous droplets from drying. The influence of the flow rate on LD was negligible, whereas for ACI, a flow rate dependence is expected. The advantages of LD and the demonstrated compatibility to established EP/USP methods motivate the substitution of the ACI and the use of LD for routine measurements.

Aerosols↗

Effect of reducing conditions on sludge melting process.

The objective of this study was to compare the effects of CO/CO(2) reducing conditions with those of air oxidizing conditions on the pouring temperature of the sludge melting process and the heavy metal leachability of the resultant sludge slag. Synthetic sludge ash composed of SiO(2), CaO and Al(2)O(3), as well as sewage sludge ash generated from a laboratory incinerator was employed. The experimental results indicated that the pouring temperatures are significantly reduced under the reducing conditions of CO/CO(2), or 24 and 77 degrees C lower than under air conditions for synthetic and sludge ash, respectively. The heavy metal leaching tests further indicate lower heavy metal concentrations present in the leachate under the reducing conditions, notably an order of magnitude lower in Zn. However, X-ray diffractogram indicates similar peaks for these two slags produced under different conditions.

Carbon Dioxide↗

The application of ultraviolet germicidal irradiation to control transmission of airborne disease: bioterrorism countermeasure.

Bioterrorism is an area of increasing public health concern. The intent of this article is to review the air cleansing technologies available to protect building occupants from the intentional release of bioterror agents into congregate spaces (such as offices, schools, auditoriums, and transportation centers), as well as through outside air intakes and by way of recirculation air ducts. Current available technologies include increased ventilation, filtration, and ultraviolet germicidal irradiation (UVGI) UVGI is a common tool in laboratories and health care facilities, but is not familiar to the public, or to some heating, ventilation, and air conditioning engineers. Interest in UVGI is increasing as concern about a possible malicious release of bioterror agents mounts. Recent applications of UVGI have focused on control of tuberculosis transmission, but a wide range of airborne respiratory pathogens are susceptible to deactivation by UVGI. In this article, the authors provide an overview of air disinfection technologies, and an in-depth analysis of UVGI-its history, applications, and effectiveness.

Air Microbiology↗

Geothermal ground gas emissions and indoor air pollution in Rotorua, New Zealand.

The emission of toxic gases from the soil is a hazard in geothermal regions that are also urbanized because buildings constructed on geothermal ground may be subject to the ingress of gases from the soil directly into the structure. The Rotorua geothermal field, New Zealand, is extensively urbanized but to date no studies have evaluated the extent of the ground gas hazard. The main gases emitted are hydrogen sulphide (H2S) and carbon dioxide (CO2), both of which are highly toxic and denser than air. This paper reports preliminary findings from a study of selected buildings constructed in the gas anomaly area. Properties were investigated for evidence of ingress by H2S, CO2, and 222Rn, with a view to determine the means and rates of gas entry and the nature of any consequent hazard. H2S and CO2 were investigated using infrared active gas analysers and passive detector tubes left in place for 10-48 h. 222Rn was measured over a period of 3 months by poly-allyl diglycol carbonate sensors. Eight of the nine buildings studied were found to suffer problems with soil gases entering the indoor air through the structure. The primary means of gas entry was directly from the ground through the floors, walls, and subsurface pipes. Indoor vents were located and found emitting up to approximately 200 ppm H2S and approximately 15% CO2, concentrations high enough to present an acute respiratory hazard to persons close to the vent (e.g., children playing at floor level). In some properties, gas problems occurred despite preventative measures having been made during construction or during later renovations. Typically, these measures include the under-laying of concrete floors with a gas-proof butanol seal, under-floor ventilation systems or the installation of positive-pressure air conditioning. Recently constructed buildings (<10 years) with butanol seals were nevertheless affected by ground gas emissions, and we conclude that such measures are not always effective in the long term.

Air Pollution, Indoor↗

Variations in the severity of retinopathy seen in newborn rats supplemented with oxygen under different conditions of hyperbarism.

The purposes of this experimental study were to evaluate the effects of oxygen supplementation delivered under hyperbaric conditions on the retinas of newborn rats and to determine the minimum and maximum levels of hyperbarism capable of protecting the retinal vessels from the toxic effects of oxygen without determining lethal effects in this experimental model. A control group of newborn rats were maintained with their mother for the first 12 days of life under room-air conditions. A second group of animals were exposed to a hyperbaric environment (+81 kPa) under normoxic conditions for the first 7 days of life and subsequently returned to normobaric conditions for the next 5 days. Examination of the retinal flat mounts from this latter group of animals revealed essentially normal vascular networks with only a modest degree of vasoconstriction. Two other litters of ratlings, with their mothers, were given supplemental oxygen at an FiO2 of 80% under a compression pressure of +101.25 kPa. In this group of animals, death of both of the mother rats from pulmonary edema occurred on the first day of treatment, and, in spite of immediate mother substitution, the newborn rats succumbed to the same complication. Five other groups, each containing two litters of newborn rats with their mothers, were exposed to FiO2s of 80% at hyperbaric levels ranging from +20.25- to +81.0 kPa for the first 7 days of life. On the eighth day, the FiO2s were reduced to 21%. After 5 days of room-air recovery, the animals were killed.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Equivalence of fast flush and square wave testing of blood pressure monitoring systems.

BACKGROUND: The accurate recording of intraarterial pressure depends upon an appropriate dynamic response of the monitoring system. Generation of a square wave (SW) at the catheter tip is the engineering and in vitro laboratory gold standard. Fast flush (FF) testing is the clinical test of choice. Results from these two test methods have been assumed equal but have not been empirically confirmed. METHODS: We studied three different 5.1 cm catheter sizes (16 G, 18 G, 20 G Becton Dickinson, Sandy, UT) attached to three different lengths of arterial pressure tubing (36 in, 91.4 cm; 72 in, 182.9 cm; 108 in, 274.3 cm). An arterial recording system was assembled in the standard fashion by attaching a catheter to arterial pressure tubing, which was attached to a transducer (TXX-R, Ohmeda, formerly Viggo-Spectramed, Oxnard, CA) whose signal was recorded by a strip chart recorder (Gould 2400, Rolling Meadows, IL). The system was attached to a pressurized saline flush. The catheter tip was inserted into one port of a pressure generator. With the other port of the pressure generator open to atmosphere, FF tests were performed by activating the flush device of the transducer. Subsequent step response signals from the FF tests were then recorded from which natural frequency (fn) and damping coefficient (zeta) were calculated. Next, square waves were generated by closing the port that was open to atmosphere and attaching a signal generator to a pressure generator. Square waves so generated were recorded as described above and natural frequency and damping coefficients calculated. These procedures were repeated after 0.05 cc of air was introduced in the transducer and repeated again in a system containing a damping device (R.O.S.E., Resonant OverShoot Eliminator, Viggo-Spectramed, Oxnard, CA). RESULTS: There was no significant difference between fn and zeta as calculated from the step response generated from the FF test versus fn and zeta as calculated from the square wave (SW) test in systems without air. However, in systems containing air, fn by FF testing was always less than fn by SW testing for all catheter sizes and extension tubing lengths (p < 0.05). Damping was also always greater by FF testing than by SW testing in systems with air for all catheter sizes and extension tubing lengths (p < 0.05). The R.O.S.E device created marked qualitative differences, although exact fn and zeta could not be quantified. CONCLUSIONS: For the characterization of dynamic response of invasive blood pressure monitoring systems, the FF test and SW test yield identical results. However, under certain conditions-air, R.O.S.E device-dynamic response as measured by FF testing was not equivalent to dynamic response as measured by the gold standard-the SW test. Specifically, small amounts of air in fluid-filled invasive blood pressure monitoring systems cause a slightly worse dynamic response as measured by FF testing versus the laboratory gold standard-the SW test.

Blood Pressure Monitors↗

Outdoor/Indoor/Personal ozone exposures of children in Nashville, Tennessee.

An ozone (O3) exposure study was conducted in Nashville, TN, using passive O3 samplers to measure six weekly outdoor, indoor, and personal O3 exposure estimates for a group of 10- to 12-yr-old elementary school children. Thirty-six children from two Nashville area communities (Inglewood and Hendersonville) participated in the O3 sampling program, and 99 children provided additional time-activity information by telephone interview. By design, this study coincided with the 1994 Nashville/Middle Tennessee Ozone Study conducted by the Southern Oxidants Study, which provided enhanced continuous ambient O3 monitoring across the Nashville area. Passive sampling estimated weekly average outdoor O3 concentrations from 0.011 to 0.O30 ppm in the urban Inglewood community and from 0.015 to 0.042 ppm in suburban Hendersonville. The maximum 1- and 8-hr ambient concentrations encountered at the Hendersonville continuous monitor exceeded the levels of the 1- and 8-hr metrics for the O3 National Ambient Air Quality Standard. Weekly average personal O3 exposures ranged from 0.0013 to 0.0064 ppm (7-31% of outdoor levels). Personal O3 exposures reflected the proportional amount of time spent in indoor and outdoor environments. Air-conditioned homes displayed very low indoor O3 concentrations, and homes using open windows and fans for ventilation displayed much higher concentrations.

Air Pollutants↗

Nonpneumonic, short-incubation-period Legionellosis (Pontiac fever) in men who cleaned a steam turbine condenser.

Pontiac fever affected ten men who had cleaned a steam turbine condenser with compressed air. Previous epidemics of Pontiac fever and Legionnaires' disease--both caused by Legionella Pneumophila (proposed sp. nov.)--involved "airborne spread" from air-conditioning cooling towers or evaporative condensers. Aerosols of contaminated water in heat-rejection systems appear to be important sources of epidemic legionellosis.

Adolescent↗

Respiratory chemosensitivity during wake and sleep in harbour seal pups (Phoca vitulina richardsii).

In this study, we examined the cardiorespiratory patterns of harbour seal pups under normoxic/normocarbic (air), hypoxic/normocarbic (15%, 12%, and 9% O2 in air), and normoxic/hypercarbic (2%, 4%, and 6% CO2 in air) conditions while awake and sleeping on land. Animals were chronically instrumented to record electroencephalogram (EEG), electromyogram (EMG), and electrocardiogram (EKG) signals, which, along with respiration (whole-body plethysmography) and oxygen consumption (VO2), were recorded from animals breathing each gas mixture for 2-4 h on separate days. Our results show that for animals breathing air, VO2 was not significantly lower during slow-wave sleep (SWS; 7.71 +/- 0.39 mL O2 min(-1) kg(-1); all measurements are mean +/- SEM) than during wakefulness (WAKE; 8.80 +/- 0.25 mL O2 min(-1) kg(-1)) and was unaffected by changes in respiratory drive. Although there was no significant fall in VO2 associated with a decrease in arousal state, breathing frequency (f(R)) did decrease (from 18.80 +/- 1.50 breaths min(-1) in WAKE to 10.40 +/- 0.49 breaths min(-1) in SWS), while the incidence of long apneas (>20 s) increased (12.76 +/- 4.06 apneas h(-1) in WAKE and 31.95 +/- 2.37 apneas h(-1) in SWS). Breathing was rarely seen during rapid eye movement (REM) sleep. Tachypnea was present at all levels of increased respiratory drive; however, hypoxia induced a dramatic bradycardia regardless of arousal state, while hypercarbia produced a tachycardia in SWS only. The hypoxic and hypercarbic chemosensitivities of harbour seal pups were similar to those of terrestrial mammals; however, unlike terrestrial mammals, where hypoxic and hypercarbic sensitivities are often reduced during SWS, the sensitivity of harbour seal pups to hypoxia and hypercarbia remained unchanged during the decrease in arousal state from WAKE to SWS.

Analysis of Variance↗

Height and lung function in preadolescent children of Kuwaitis and European origin: a pilot survey on health effects of gas cooking in the Middle East.

Spirometric testing, including forced vital capacity (FVC), forced expiratory volume in .5 s (FEV0.5), FEF25-75%, and peak expiratory flow resistance (PEFR), was conducted among 130 10-y-old children (67 Kuwaitis, 63 Europeans) who lived with their parents in the same area in Kuwait city. Lung function of children who lived in houses with gas stoves were compared with those who lived in homes supplied with electric cookers. The FEV0.5 for children who lived in households with gas stoves was significantly lower (average difference, 94 ml; p = .05; corrected to height and sex). Other lung function indices, i.e., FVC, FEF25-75%, and PEFR, were also lower but, after accounting for confounders, were not statistically significant. Children from households that were equipped with gas cookers were approximately 3 cm shorter than children who lived in homes with electric cookers. These findings suggest that children who live in a very hot and dry climate--even with efficient air conditioning systems--are susceptible to the same environmental hazards to which children from other climatic zones are exposed. This susceptibility may be more pronounced before or at the onset of puberty.

Air Pollution, Indoor↗