Ballistocardiogram artifact removal from EEG signals using adaptive filtering of EOG signals.

We estimated ballistocardiogram (BCG) components in EEG signals recorded inside an MRI magnet using the electro-oculogram (EOG) signals recorded simultaneously with the EEG signals. Since the EOG signals are measured near the EEG measuring points, it is thought that the BCG components in the EOG signals resemble the BCG components in the EEG signals. To estimate the BCG components in the EEG signals, we applied the Kalman filter to the EOG and EEG signals recorded inside a 3.0 T MRI magnet. After removing the estimated BCG components from the EEG signals, we extracted the visual-evoked potentials (VEPs) from the BCG-removed EEG signals. To validate the efficacy of Kalman filtering in the BCG artifact removal, we have compared three types of VEPs of eight healthy subjects: one extracted from the raw EEG signals measured outside the magnet and the others extracted from the BCG-removed EEG signals measured inside the magnet. The BCG artifacts have been removed with Kalman filtering as well as with the conventional BCG template subtraction method for the sake of comparison. No significant difference in waveforms, latencies and amplitudes has been found between the two types of VEPs extracted from the two kinds of BCG-removed EEG signals.

Adult↗

Removal of ocular artifacts from EEG using adaptive thresholding of wavelet coefficients.

Electroencephalogram (EEG) gives researchers a non-invasive way to record cerebral activity. It is a valuable tool that helps clinicians to diagnose various neurological disorders and brain diseases. Blinking or moving the eyes produces large electrical potential around the eyes known as electrooculogram. It is a non-cortical activity which spreads across the scalp and contaminates the EEG recordings. These contaminating potentials are called ocular artifacts (OAs). Rejecting contaminated trials causes substantial data loss, and restricting eye movements/blinks limits the possible experimental designs and may affect the cognitive processes under investigation. In this paper, a nonlinear time-scale adaptive denoising system based on a wavelet shrinkage scheme has been used for removing OAs from EEG. The time-scale adaptive algorithm is based on Stein's unbiased risk estimate (SURE) and a soft-like thresholding function which searches for optimal thresholds using a gradient based adaptive algorithm is used. Denoising EEG with the proposed algorithm yields better results in terms of ocular artifact reduction and retention of background EEG activity compared to non-adaptive thresholding methods and the JADE algorithm.

Adaptation, Physiological↗

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Correction of sequence-based artifacts in serial analysis of gene expression.

MOTIVATION: Serial Analysis of Gene Expression (SAGE) is a powerful technology for measuring global gene expression, through rapid generation of large numbers of transcript tags. Beyond their intrinsic value in differential gene expression analysis, SAGE tag collections afford abundant information on the size and shape of the sample transcriptome and can accelerate novel gene discovery. These latter SAGE applications are facilitated by the enhanced method of Long SAGE. A characteristic of sequencing-based methods, such as SAGE and Long SAGE is the unavoidable occurrence of artifact sequences resulting from sequencing errors. By virtue of their low-random incidence, such tag errors have minimal impact on differential expression analysis. However, to fully exploit the value of large SAGE tag datasets, it is desirable to account for and correct tag artifacts. RESULTS: We present estimates for occurrences of tag errors, and an efficient error correction algorithm. Error rate estimates are based on a stochastic model that includes the Polymerase chain reaction and sequencing error contributions. The correction algorithm, SAGEScreen, is a multi-step procedure that addresses ditag processing, estimation of empirical error rates from highly abundant tags, grouping of similar-sequence tags and statistical testing of observed counts. We apply SAGEScreen to Long SAGE libraries and compare error rates for several processing scenarios. Results with simulated tag collections indicate that SAGEScreen corrects 78% of recoverable tag errors and reduces the occurrences of singleton tags. AVAILABILITY: The SAGEScreen software is available for academic users from the first author.

Algorithms↗

Alu-mediated PCR artifacts and the constitutional t(11;22) breakpoint.

The breakpoints of the recurrent t(11;22)(q23;q11) have recently been cloned. We identified palindromic AT-rich repeats (PATRRs) on 11q23 and 22q11 as the mechanism responsible for the rearrangement. Contradictory to our results, A.S. Hill et al. (Hum. Mol. Genet., 9, 1525-1532) suggested that Alu-mediated recombination is responsible. To clarify this discrepancy, the cloned 4.5 kb der(11) junction fragment has been completely sequenced. This sequence has been compared with that of an inverse PCR-generated der(11) junction fragment obtained by Hill et al. This reveals that the inverse PCR product has sustained a deletion between two Alu elements, such that the true breakpoint region is deleted from the PCR product. Utilizing PCR primers designed by Hill et al. to amplify across the der(11) breakpoint, we obtained a deleted PCR product even when our cloned der(11) junction fragment was used as template. Further, we find that the PCR primers that they utilized for amplification of the der(22) junction fragment are not located on the der(22). They are oriented in opposite directions within the region deleted from the der(11) PCR product, generating an artifact derived from the der(11) chromosome. Analysis of the truncated PCR products indicates a mixture of sequences from two distinct Alu elements, suggesting that the putative junction fragment described by Hill et al. is an Alu-mediated PCR artifact. These data suggest that caution should be exercised when analyzing PCR-based data, particularly when amplification is carried out in a region containing repeat structures with specific, difficult-to-amplify sequences.

Alu Elements↗

Brain SPECT artifact in multidetector SPECT system.

Stringent quality control cannot be overemphasized in performing SPECT. SPECT artifacts related to camera uniformity, center of rotation, and the patient's motion are well recognized. In this communication, another rare cause of a SPECT artifact related to a triad system is reported. A triple-headed SPECT system was accidentally equipped with two ultrahigh-resolution collimators and a general all-purpose collimator during a brain SPECT study, causing a false cerebral blood flow defect.

Aged↗

Reduction of artifacts from breathing and peristalsis in phase-contrast MRA of the chest and abdomen.

Strategies for the acquisition of temporally resolved phase-contrast angiography are described and demonstrated. Projections are acquired through the entire thickness of the subject permitting excitation geometries to be independent of image orientation. Minimal delays are used between the acquisition of oppositely flow-encoded data resulting in fewer artifacts from movement of nominally stationary tissue. A protocol that suppresses artifacts from both peristalsis and breathing is presented for the aortic arch and iliac arteries.

Abdomen↗

Evaluation of a FLAIR sequence designed to reduce CSF and blood flow artifacts by use of k-space reordered by inversion time at each slice position (KRISP) in high grade gliomas of the brain.

The objective of this study was to compare conventional and KRISP (k-space reordered by inversion time at each slice position) fluid-attenuated inversion recovery (FLAIR) sequences in high grade gliomas for artifact control, conspicuity of intracranial structures, and lesions as well as sensitivity to contrast enhancement. Artifacts were lower with the KRISP FLAIR sequence, and the conspicuity of all assessed structures and lesions was better. The degree of contrast enhancement was similar with T1-weighted and KRISP FLAIR sequences.

Adult↗

Laryngopharyngeal reflux identified using a new catheter design: defining normal values and excluding artifacts.

OBJECTIVE: To define normal values for laryngopharyngeal reflux using an improved catheter design with adjustable electrode placement for pH monitoring. STUDY DESIGN: Cohort study of normal volunteers. METHODS: The setting was an institutional-based gastroenterology practice. Subjects included 20 healthy volunteers with no history of laryngeal, pharyngeal, or reflux symptoms. These included 10 men and 10 women (mean age, 33 y; age range, 26-49 y). Ambulatory 24-hour triple-electrode monitoring of pH in distal esophagus, proximal esophagus, and pharynx using new bifurcated probe was performed. The distal electrode was placed 5 cm above the lower esophageal sphincter, with the proximal two electrodes straddling the upper sphincter. The main outcome measure was the number of true pharyngeal reflux episodes. RESULTS: Sixteen of 20 subjects had no episodes, and 2 subjects had only one episode of pharyngeal reflux. The two subjects exceeding this value (8 and 15 episodes, respectively) had abnormal distal and proximal esophageal reflux. Artifacts for pharyngeal reflux due to acidic meals or "pseudoreflux" were excluded. Subject tolerance of this new probe was excellent. CONCLUSION: The triple-electrode bifurcated adjustable pH probe provides a well-tolerated technique to identify true hypopharyngeal acid reflux episodes. When artifacts produced by meals and pseudoreflux are excluded, 90% of normal subjects show no episodes or a single episode over a 24-hour period.

Adult↗

The ratio of the apex/anterior wall: a marker of breast attenuation artifact in women.

BACKGROUND: Breast attenuation artifact is well known for reducing the accuracy of myocardial perfusion imaging in women. We have noticed the particular pattern of relative preservation of apical activity in women with breast attenuation and decreased anterior wall counts. This study was undertaken to see if this finding could be used to improve the accuracy of perfusion imaging in women. METHODS: We identified 295 women referred for exercise stress testing using (201)Tl single photon emission computed tomography (SPECT) of whom 193 had less than 5% probability of coronary disease and 102 had coronary artery disease documented by catheterization within 60 days of stress testing (mean of 1.8+/-0.8 vessels with=50% stenosis). Patients with documented myocardial infarction, pathologic Q waves, left bundle branch block, non-ischaemic cardiomyopathy or prior bypass grafting were excluded. Volume-weighted bullseye plots were generated and normalized to 100; next, regions of interest were drawn over the anterior wall and apex in all patients and the ratio of the mean counts of each region was calculated. The normals were further divided into those with breast attenuation (defined as mean anterior counts <70% maximum) and those without. Defect scores of all patients were calculated; a formula to adjust the score for patients with breast attenuation was developed. Accuracy was assessed by calculating the area under the receiver operating curve. RESULTS: The normals, overall, had a mean ratio of 1.0+/-0.08 vs. 0.9+/-0.16 for those with coronary disease (P<0.0001). In normals with breast attenuation the ratio was 1.1+/-0.08 compared to 0.99+/-0.07 (P<0.0001) without. By adjusting the anterior wall defect score in patients with apex/anterior ratio >1 we were able to improve the accuracy from 0.808+/-0.028 to 0.826+/-0.027 (P<0.01). CONCLUSIONS: A ratio of the apex to the anterior wall >1 is not physiological and suggests the presence of significant breast attenuation artifact. This finding can be used to produce a small but statistically significant improvement in the accuracy of quantitative thallium SPECT in women who have not undergone coronary bypass grafting.

Artifacts↗

Coronary artery stents in multislice computed tomography: in vitro artifact evaluation.

RATIONALE AND OBJECTIVE: The aim of this study was to systematically compare the ability to assess the coronary artery lumen in the presence of coronary artery stents in multislice spiral CT (MSCT). METHODS: Ten different coronary artery stents were examined with 4- and 16-detector row MSCT scanners. For image reconstruction, a standard and a dedicated convolution kernel for coronary artery stent visualization were used. Images were analyzed regarding lumen visibility, intraluminal attenuation, and artifacts outside the stent lumen. Results were compared using repeated-measure analysis of variance. RESULTS: Depending on stent type, scanner hardware, and convolution kernel, artificial lumen narrowing ranged from 20% to 100%. The convolution kernel had the most significant influence on the visibility of the stent lumen. Artificial lumen narrowing and intraluminal attenuation changes decreased significantly using the dedicated convolution kernel. In general, most severe artifacts were caused by gold or gold-coated stents. CONCLUSIONS: Independent of the scanner hardware or dedicated convolution kernels, routine evaluation of most coronary artery stents is not yet feasible using MSCT.

Analysis of Variance↗

Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed.

OBJECTIVES: We sought to evaluate the impact of patients' heart rate (HR) on coronary CTA image quality (IQ) and motion artifacts using a 64-slice scanner with 0.33/360 degrees rotation. MATERIALS AND METHODS: Coronary CTA data sets of 32 patients (HR 65 bpm to 75 bpm, n = 7) examined on a 64-slice scanner (Sensation 64, Siemens Medical Solutions, Forchheim, Germany) with 0.33s/360 degrees gantry rotation speed were analyzed. All patients had suspicion of coronary artery disease. Data acquisition was performed using 64 x 0.6-mm collimation, and contrast enhancement was provided by injection of 80 mL of iopromide (5 mL/s + NaCl). Images were reconstructed throughout the RR interval using half-scan and dual-segment reconstruction. IQ was rated by 2 observers using a 3-point scale from excellent (1) to nondiagnostic (3) for coronary segments. Quality was correlated to the HR, time point of optimal IQ analyzed, and the benefit of dual-segment reconstruction evaluated. RESULTS: Overall mean IQ was 1.31 +/- 0.32 for all HR, with IQ being 1.08 +/- 0.12 for HR 65 bpm 75 bpm (P = 0.0003). Dual-segment reconstruction did not significantly improve IQ in any HR group (P = NS). Mean IQ was significantly better for LAD than for RCA (P < 0.0001) and LCX (P < 0.01). A total of 3.5% (11/318) of coronary artery segments were rated nondiagnostic by at least one reader based on motion artifacts. Although in HR < 65 bpm, the best IQ was predominately in diastole (93%), in HR > 75 bpm, the best IQ shifted to systole in most cases (86%). CONCLUSIONS: Temporal resolution at 0.33-second rotation allows for diagnostic IQ within a wide range of HR using half-scan reconstruction. With increasing HR the time point of best IQ shifts from mid-diastole to systole.

Adult↗

Computing genetic similarity coefficients from RAPD data: correcting for the effects of PCR artifacts caused by variation in experimental conditions.

The production of informative random amplified polymorphic DNA (RAPD) markers using PCR and a single primer is often accompanied by the generation of artifactual (noninformative) bands as well. When RAPD data are used to compute genetic similarity coefficients, these artifacts (false positives, false negatives, or both) can cause large biases in the numerical values of the coefficients. As a result, some workers have been reluctant to use RAPD markers in the estimation of genetic similarities. Artifactual bands are of two types: those caused by variation in experimental conditions, and those caused by characteristics of the DNA to be amplified. A procedure is described that allows for correction of the bias caused by the first type of artifact, providing that replicate DNA samples have been extracted, amplified, and scored. The resulting data are used to obtain an estimate of the proportion of false-positive and false-negatives bands. These values are then used to correct the bias in the computed similarity coefficients. Two examples are given, one in which bias correction is critical to the results, and one in which it is less important. The maximum percent bias, computed from the estimated proportions of false positives and false negatives in the RAPD data set, is proposed as a criterion for determining whether bias correction of the similarity coefficients is required or not. Although all reasonable efforts should be made to optimize PCR protocols to eliminate artifactual bands, when this is not possible, the methods described allow RAPD markers to compute genetic similarities reliably and accurately, even when artifactual bands resulting from variation in experimental conditions are present.

Artifacts↗

Adaptive stimulus artifact reduction in noncortical somatosensory evoked potential studies.

Somatosensory evoked potentials (SEP's) are an important class of bioelectric signals which contain clinically valuable information. The surface measurements of these potentials are often contaminated by a stimulus evoked artifact. The stimulus artifact (SA), depending upon the stimulator and measurement system characteristics, may obscure some of the information carried by the SEP's. Conventional methods for SA reduction employ hardware-based circuits which attempt to eliminate the SA by blanking the input during SA period. However, there is a danger of losing some of the important SEP information, especially if the stimulating and recording electrodes are close together. In this paper, we apply both linear and nonlinear adaptive filtering techniques to the problem of SA reduction. Nonlinear adaptive filters (NAF's) based on truncated second-order Volterra series expansion are discussed and their applicability to SA cancellation is explored through processing both simulated and in vivo SEP data. The performances of the NAF and the finite impulse response (FIR) linear adaptive filter (LAF) are compared by processing experimental SEP data collected from different recording sites. Due to the inherent nonlinearities in the generation of the SA, the NAF is shown to achieve significantly better SA cancellation compared to the LAF.

Algorithms↗

Artifact reduction in magnetoneurography based on time-delayed second-order correlations.

Artifacts in magnetoneurography data due to endogenous biological noise sources, like the cardiac signal, can be four orders of magnitude higher than the signal of interest. Therefore, it is important to establish effective artifact reduction methods. We propose a blind source separation algorithm using only second-order temporal correlations for cleaning biomagnetic measurements of evoked responses in the peripheral nervous system. The algorithm showed its efficiency by eliminating disturbances originating from biological and technical noise sources and successfully extracting the signal of interest. This yields a significant improvement of the neuro-magnetic source analysis.

Algorithms↗

Artifact-resistant power-efficient design of finger-ring plethysmographic sensors.

A miniaturized, telemetric, photoplethysmograph (PPG) sensor for long-term, continuous monitoring is presented in this paper. The sensor, called a "ring sensor," is attached to a finger base for monitoring beat-to-beat pulsation, and the data is sent to a host computer via a radio-frequency transmitter. Two major design issues are addressed: one is to minimize motion artifact and the other is to minimize the consumption of battery power. An efficient double ring design is developed to lower the influence of external force, acceleration, and ambient light, and to hold the sensor gently and securely on the skin, so that the circulation at the finger may not be obstructed. Total power consumption is analyzed in relation to characteristics of individual components, sampling rate, and CPU clock speed. Optimal operating conditions are obtained for minimizing the power budget. A prototype ring sensor is designed and built based on the power budget analysis and the artifact-resistive attachment method. It is verified through experiments that the ring sensor is resistant to interfering forces and acceleration acting on the ring body. Benchmarking tests with FDA-approved PPG and electrocardiogram reveal that the ring sensor is comparable to those devices in detecting beat-to-beat pulsation despite disturbances.

Adult↗

Three-dimensional artifact induced by projection weighting and misalignment.

In recent years, the use of computer graphic techniques to produce three-dimensional (3-D) and reformatted images from a set of axial computed tomography (CT) images has gained significant interest. In most cases, the CT images are generated with the projection data set weighted prior to reconstruction, to combat motion artifacts, data inconsistency, or redundant data samples. In this paper, we investigate the potential bias introduced to the reconstruction as a result of the interaction of the projection weights and the isocenter misalignment (ISM). We demonstrate that when the weights applied to the conjugate rays are significantly different, bias will result which favors the sample with a higher weight. Although the error is not easily detected in axial CT images, it can be quite visible in 3-D or multiplanar reformatted (MPR) images. In this paper, we first present a theoretical framework to analyze and predict the bias. The theoretical prediction is validated by both computer simulations and phantom experiments. Several schemes to combat this artifact are subsequently presented; and their effectiveness is demonstrated.

Artifacts↗

A perspective on needle artifacts in MRI: an electromagnetic model for experimentally separating susceptibility effects.

A thorough understanding of artifacts caused by metallic instruments is essential for the guidance of interventional procedures by magnetic resonance imaging (MRI), because the accurate localization of each instrument is mandatory for this. In the past, this problem has been addressed by several groups, using theoretical, as well as experimental approaches. The artifacts associated with MRI are caused by geometry distortion and intravoxel dephasing. Usually, both effects mingle in the image, and depending on the pulse sequences and its parameters used for data acquisition, these effects are reflected in the image with different magnitude. In this paper we shortly present the well-known mathematical background of the two underlying effects. Mathematically, both can be treated separately. Here, we propose a new electromagnetic model which also allows to experimentally separate the effects better than by comparing spin-echo and gradient-echo images of the same object. With this new model, both effects-geometry distortion and intravoxel dephasing-are demonstrated separately using the same gradient-echo pulse sequence for all scans and adjusting the fields of the model properly. Furthermore, as this model allows to adjust both effects independently, it is used to study different weightings of both effects when they appear simultaneously in the image.

Artifacts↗