Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “TECHNETIUM”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56Linked to original sources

Gastric emptying in infants with gastroesophageal reflux. Measurement with a technetium-99m-labeled semisolid meal.

It is well established that liquid emptying occurs in the absence of motor activity of the stomach. In contrast, solid-phase emptying is controlled in part by antral peristalsis and is, therefore, a more precise indicator of gastric motility. We developed a semisolid, radionuclide gastric emptying test using rice cereal and technetium-99m-sulfur colloid to assess antral physiology in infants with vomiting. Computer-programmed mathematical models were used to determine the shape of a line that best fit our emptying data points. Linear, simple exponential [f = 2-(t/t1/2)], and power exponential [f = 2(t/t1/2)beta] patterns of emptying were calculated, where f is the fraction of the meal remaining in the stomach at time t, and t1/2 is the time when 50% of the meal has emptied and is a determinant of the shape of the curve. In infants with simple regurgitation (chalasia) and those with vomiting and failure to gain weight, we made statistical comparisons between gastric emptying patterns after analysis of the mean percentage of retained radionuclide at 120 min, calculated t1/2, and area under the curve. The coefficient of determination, R2, was calculated as an index of whether a curve provided goodness of fit to the data. Differences between groups of patients were statistically significant for all parameters of each mathematical model. However, higher coefficients of determination were noted in the power exponential model. The data suggest that the power exponential mathematical model provides the best analysis of the gastric emptying patterns for infants with chalasia and those with vomiting and failure to gain weight.(ABSTRACT TRUNCATED AT 250 WORDS)

Adsorption↗

Technetium-99m sestamibi and tetrofosmin myocardial single-photon emission tomography: can we use the same reference data base?

The aim of this study was to compare technetium-99m labelled tetrofosmin and sestamibi myocardial perfusion single-photon emission tomography (SPET) with one common sestamibi reference file for bull's eye imaging, with quantitation of the extent and severity of perfusion defects. Twenty patients suspected or known to have coronary artery disease participated in the study. Patients first underwent routine sestamibi myocardial SPET over 2 days, receiving doses of 400-600 MBq at stress and 600-800 MBq at rest. Then within the same week a 1-day tetrofosmin myocardial SPET study was performed, with a dose of 300 MBq at stress, followed 2.5 h later by a dose of 750 MBq at rest. Bull's eye images were generated for visual evaluation. Black-out defects according to the Cequal software analysis were only recorded if they comprised more than 10 pixels in men and 20 in women. According to the Cequal program, extent score and severity scores were expressed as number of pixels and deviations below reference limits. Five patients had normal myocardial SPET imaging with both radiotracers, while 15 had reversible, irreversible or partially reversible defects. The concordance of the results was high. The only two significant differences were that one patient had a reversible defect which appeared to be located in different myocardial regions (LAD vs RCA), and another patient had a defect that was partially reversible with sestamibi but irreversible with tetrofosmin. The results showed very high correlation coefficients for the extent and severity scores (linear correlation coefficient values of 0.99 and 0.94, respectively). In conclusion, it appears that changing between sestamibi and tetrofosmin has little influence on the interpretation of bull's eye images from the data file of a common reference population using one of the tracers.

Coronary Disease↗

Presurgical localization of abnormal parathyroid glands using a single injection of technetium-99m methoxyisobutylisonitrile: comparison of different techniques including factor analysis of dynamic structures.

Single-tracer methoxyisobutylisonitrile (MIBI) imaging is considered to be a sensitive method for the localization of abnormal parathyroid glands. The aims of this study were to determine which of the analytical techniques described for this method - visual comparison of early (15-min) and late (120-min) images, use of time-activity curves (TACs) generated on regions of interest and factor analysis of dynamic structures (FADS) - corresponds best with surgical findings, and to ascertain the potential overall contribution of presurgical scintigraphy. Fifty-five patients were studied, 34 of whom presented with primary hyperparathyroidism (HPT) and 21 with secondary HPT. After a 925 MBq injection of technetium-99m MIBI, a 40-min dynamic acquisition was performed and static images were acquired at 5, 20, 40 and 120 min using a gamma camera equipped with a pinhole collimator. The dynamic series were submitted to FADS, an attractive non-operator-dependent technique, and TACs were generated on regions of interest after the visual comparison of early and 120-minute images (15'-120'). The presumed localizations of abnormal glands were compared with a sketch drawn by the surgeon. Sensitivity was defined as the percentage of true-positive localizations and was 84.4%, 74% and 65% in adenoma and 76%, 66.6% and 45% in hyperplasia for 15'-120', FADS and TACs, respectively. Surgical accuracy, i.e. the percentage of patients accurately and completely described, was 72%, 56% and 59% in adenoma and 53%, 30% and 22% in hyperplasia for 15'-120', FADS and TACs, respectively. The visual comparison method scored best in all cases. FADS was found to be sensitive in cases of adenoma but was handicapped by more false-positive localizations. TACs were particular inefficient in hyperplasia. With respect to the detection of adenomas, we found a relationship between the gland weight and scintigraphic positivity. This dependence on gland weight was not found in hyperplasia. The poorer results obtained with all techniques for surgical accuracy can be explained by the need for a complete scintigraphic description of all pathological glands found by the surgeon in a patient. This study demonstrates that the 15'-120' visual comparison method is more efficient and less cumbersome than TAC or the attractive FADS technique. However, it was less efficient than neck exploration by an experienced surgeon. Therefore, in our institution, scintigraphic studies are now only requested in selected cases of HPT, usually primary HPT and cases undergoing re-operation.

Adenoma↗

Detection of radiation-induced myocardial damage by technetium-99m sestamibi scintigraphy.

A prospective study was initiated to assess the side-effects of postoperative adjuvant radiotherapy in patients with left-sided early breast cancer. Twelve patients with early breast cancer were examined before and a year after radiotherapy. Echocardiography, ECG and bicycle ergometry stress test with technetium-99m sestamibi myocardial perfusion scintigraphic were carried out to assess changes in regional myocardial blood flow. Six of the 12 patients had new fixed scintigraphic defects after radiotherapy (as compared with the preradiation examination). The localization of the defects corresponded well with the irradiated volume of the left ventricle. These defects were probably due to microvascular damage to the myocardium. Neither ECG changes nor left ventricular segmental wall motion abnormalities could be detected by echocardiography. To our knowledge this study is the first to show that radiation-induced micro-vascular damage to the myocardium may be detected by perfusion scintigraphy. This may limit the use of scintigraphy in diagnosing coronary artery disease in patients treated with thoracic radiotherapy. Long-term follow-up is necessary to assess whether the presence of microvascular damage is a prognostic sign for the development of radiation-induced coronary artery disease.

Breast Neoplasms↗

Structural modification of receptor-binding technetium-99m complexes in order to improve brain uptake.

Low brain uptake is a generally accepted problem in developing technetium-99m brain receptor imaging agents. For a class of potential 5-HT2A receptor-binding agents we tried to improve the original low brain uptake of 0.4% injected dose (ID) in rats 5 min p.i. by modifying the lipophilic properties of the molecules. Because of the presence of a protonable nitrogen, which according to the pKa value leads to ionization of the molecule at blood pH, the pKa value was considered to be the parameter most suitable for adjustment of lipophilicity. Insertion of ether-oxygen in the molecule of five candidates lowers the apparent pKa value from 10.0 to 8.3 and dramatically increases the brain uptake to 1.3% ID at 5 min. The direct relationship between brain uptake and apparent pKa cannot be simply explained by the increase in the pKa-governed proportion of the neutral species.

Animals↗

Parathyroid scintigraphy: first experiences with technetium (III)-99m-Q12.

We report the preliminary results of a prospective study demonstrating technetium(III)-99m furifosmin (Q12) uptake in histologically proven parathyroid adenomas. Scintigraphy was performed in 12 patients with hyperparathyroidism. Q12 correctly identified the parathyroid adenomas by focal prolonged tracer retention in ten of the 12 patients. In the two patients without localized tracer retention, no parathyroid adenoma could be identified surgically, either. The retention half-times ranged from 0.5 to 1.8 h (mean 1.27) in the parathyroid adenomas and from 0.3 to 1.2 h (mean 1.05) in the thyroid gland. Our preliminary results show that Q12 is a feasible, sensitive tracer for parathyroid scintigraphy. In comparison to sestamibi (MIBI) and tetrofosmin, Q12 displays short retention in the thyroid gland, which would seem rather advantageous. Further evaluation is needed to determine which among Q12, tetrofosmin and MIBI is most sensitive for the detection especially of small parathyroid adenomas, and which tracer properties will best reflect the degree of endocrine activity.

Adenoma↗

Technetium-99m hexamethylpropylene amine oxime single-photon emission tomography of regional cerebral blood flow in insulin-dependent diabetes.

The study was performed to investigate subclinical abnormalities in regional cerebral blood flow (rCBF) in patients with insulin-dependent diabetes mellitus (IDDM) and to correlate them with patients characteristics. After intravenous injection of technetium-99m hexamethylpropylene amine oxime (HMPAO), tracer uptake of the prefrontal, frontal and parieto-occipital zones was measured with a triple-head single-photon emission tomography (SPET) camera system in 35 IDDM patients outside an episode of hypoglycaemia. Tracer uptake values in 16 age- and sex-matched healthy volunteers served as reference values. Compared with healthy subjects, increased tracer uptake of both prefrontal regions and the left frontal region could be shown in diabetes. Tracer uptake was negatively correlated with the duration of diabetes in all investigated regions. In diabetic patients with a disease duration of more than 5 years (n=26), stepwise regression analysis revealed a significant positive correlation between their HbA1c levels and tracer uptake. Long-term diabetic patients with reduced (pre)frontal tracer uptake (n=8) had lower HbA1c levels than those without (8.4%+/-0.2% vs 9.3%+/-0.3%, P<0.05) and tended to have more frequently a history of hypoglycaemic coma (6/8 vs 6/18, P=0.06). It can be concluded that duration of diabetes contributes to subclinical changes in basal rCBF in IDDM as detected with HMPAO SPET of the brain. The positive correlation between the presence of regional hypoperfusion and lower HbA1c levels in long-term diabetic patients may be interpreted in the light of a presumed higher incidence of hypoglycaemia as metabolic control improves.

Adult↗

Reproducibility of technetium-99m mercaptoacetyltriglycine clearance.

The aim of this paper was to determine the reproducibility (precision) of technetium-99m mercaptoacetyltriglycine (MAG3) clearance and to compare it with that of chromium-51 ethylenediamine tetra-acetic acid (EDTA). Twelve young volunteers (aged between 21 and 34 years), without any history of medical problems, were enrolled in this study. The test was performed twice, at an interval of 8 days and under similar physiological conditions. After the intravenous injection of both tracers, 15 blood samples were taken between 3 and 240 min. A biexponential fit was adapted to the plasma disappearance curves (5- to 120-min samples for 99mTc-MAG3 and 10- to 240-min samples for 51Cr-EDTA); the clearances were calculated according to Sapirstein and corrected for body surface area. The mean clearance values were 110 (range 85-130) and 226 (range 109-319)ml/min/1.73 m2, respectively, for 51Cr-EDTA and 99mTc-MAG3. For 51Cr-EDTA clearance, the mean difference between the first and the second measurement was -2.1% of the mean of the two successive values (SD: 8.4%). In ten cases, the difference was less than 12%; in two cases, the differences were 15% and 18%, respectively. For 99mTc-MAG3 clearance, the mean difference between the first and the second measurement was -20% of the mean of the two successive values (SD: 25%). In six cases, the difference was less than 12%; in four cases, between 15% and 40%; and in two cases, more than 60%. Methodological factors (impurities contained in the commercial kit, variable protein binding) as well as physiological factors (pH of urine, sodium load, stress) may explain the lack of precision of the 99mTc-MAG3 clearance. It is concluded that changes in 99mTc-MAG3 plasma clearance should be interpreted with care in daily routine.

Adult↗

Assessment of myocardial area at risk by technetium-99m sestamibi during coronary artery occlusion: comparison between three tomographic methods of quantification.

The aim of this study was to directly compare three currently used quantitative methods of analysis of technetium-99m sestamibi images in patients with selective balloon-induced transmural ischaemia. The area at risk (AR) was assessed in 19 patients undergoing single-vessel percutaneous transluminal coronary angioplasty by injecting the 99mTc-sestamibi at the time of coronary artery occlusion during balloon inflation. After imaging, the patients were classified according to localization of the perfusion defect as having anteroseptal (group I, 11 patients) or posterolateral defects (group II, eight patients). The planimetric technique based on polar maps, proposed by Verani et al. (J Am Coll Cardiol, 1988) (method A), the method described by Tamaki et al. (Circulation, 1982) (method B) and the technique validated by O Connor et al. (Eur J Nucl Med, 1990) (method C) were tested. Three threshold values of 45%, 50% and 60% of the maximum left ventricular count were used to define the limits of the perfusion defect. The mean values of the AR calculated by the three techniques with the original cut-off level (method A=16.5%+/-12.9; method B=10.4%+/-7.6%; method C=29.6%+/-15.7%) were statistically different (one-way analysis of variance: P<0.001; paired t test: method A vs B, P=0.003; method B vs C and method A vs C, P<0.0001). There was no significant difference between the mean values of the AR estimated by the three methods using the same cut-off levels. The use of 60% of the maximum left ventricular count provided the best correlation between the techniques (method A vs B, r=0.95; method B vs C, r=0.92; method A vs C, r=0.95). Nevertheless, a difference >10% between the values of AR assessed by the three methods was found in four subjects. There was no significant difference between the three methods in the evaluation of AR in the subjects of group I and group II. Reproducibility was good for all methods. It is concluded that the three methods of analysis of the AR by 99mTc-sestamibi SPET imaging showed comparable performance and good reproducibility using the same cut-off level. The location of perfusion defect does not affect the comparability of the three techniques. We suggest the use of a cut-off level of 60% for all three methods in the assessment of the AR by 99mTc-sestamibi SPET imaging.

Angioplasty, Balloon, Coronary↗

Positive thyroid cancer scintigraphy using technetium-99m methoxyisobutylisonitrile.

The aim of the study was to evaluate the possibility of detecting thyroid cancer recurrences without the need for withdrawal of thyroid suppressive treatment. Upper-body or whole-body scintigraphy was performed in a group of 200 patients evaluated for differentiated thyroid cancers in 1993 and 1994 using technetium-99m sestamibi. Scans were performed 20-30min following i.v. administration of 500MBq of 99mTc-methoxyisobutylisonitrile (MIBI). Bone and lung metastases were detected with very high sensitivity and specificity, with a very high predictive value of negative results and a somewhat lower predictive value of positive results. The sensitivity and specificity of findings in the neck were lower but the predictive value of negative results was high. Whole-body scans with 99mTc-MIBI are a useful tool in the follow-up of patients with differentiated thyroid cancer, for the detection of distant metastatic lesions.

Bone Neoplasms↗

Cardiac and pleuropulmonary AL amyloid imaging with technetium-99m labelled aprotinin.

Antiproteases are known to be present in amyloid deposits. We evaluated the possibility of using an anti-serine protease (aprotinin) labelled with technetium-99m (TcA), usually employed as a cortical renal tracer, for the imaging of amyloid deposits. Because of the known high uptake of TcA by the kidneys, we limited our analysis to extra-abdominal amyloid localizations. We report the scintigraphic findings observed in 24 patients with light chain amyloidosis (AL) and one with a hereditary form who were known or suspected to have extra-abdominal involvement. Planar scans obtained 100min after i.v. TcA administration showed myocardial accumulation in 11 patients, pleuropulmonary accumulation in nine, pericardial accumulation in two and localization in the neck region (thyroid, salivary glands and tongue) in eight. TcA scintigraphy was negative in five patients without clinical or laboratory evidence of extra-abdominal involvement, as well as in 12 control group patients with cardiac and renal diseases. These preliminary results indicate TcA to be a low-cost, readily available radiopharmaceutical for imaging of extra-abdominal involvement in AL type amyloidosis.

Adult↗

A miniaturized rapid paper chromatographic procedure for quality control of technetium-99m sestamibi.

A miniaturized rapid paper chromatographic technique (MRPC) for quality control of a technetium-99m sestamibi preparation was developed and compared with the manufacturer's and Hung et al. techniques. The MRPC system involves the use of 6.0x0.5cm Whatman 3MM paper strip developed in ethyl acetate. The procedure was completed within 3min while that of the manufacturer and Hung techniques took 30-35 and 4min respectively. The Rf range of 99mTc-sestamibi using MRPC was 0.55-0.75 while that of the other two techniques was 0.9-1.0. The results indicate that MRPC can be used to separate 99mTc-sestamibi from any 99mTc contaminant that migrates with the solvent front. The MRPC is a fast and effective chromatographic technique for routine quality control testing of 99mTc-sestamibi preparation.

Chromatography, Paper↗

Uptake of technetium-99m hexamethylpropylene amine oxime labelled white cells in lymph nodes involved in non-Hodgkin's lymphoma.

Radiolabelled white cell scanning is widely used to detect the presence of infection. We present a case of non-Hodgkin s lymphoma manifesting with signs and symptoms suggestive of infection, in which a technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) white cell scan demonstrated high uptake in lymph nodes involved by lymphoma. Differential cell analysis showed preferential lymphocyte labelling. The classification and management of the disease were changed accordingly. Our findings suggest that a future role for 99mTc-HMPAO labelled white cells in the assessment of disease activity of lymphoma should be investigated.

Diagnosis, Differential↗

Technetium-99m-labeled red blood cell scans in the investigation of gastrointestinal bleeding.

PURPOSE: Technetium-99m-labeled red blood cell scans (Tc99m RBC scan) are recommended to confirm gastrointestinal (GI) bleeding. It is controversial whether these scans are sufficient to localize the site of bleeding. This study evaluated the efficacy of RBC scans in confirming and localizing GI bleeding. Our hypothesis was that these scans were effective in localizing GI bleeding if positive within the continuous phase of imaging. METHOD: Tc99m RBC scans were performed on a total of 80 patients over a four-year period to localize GI bleeding (59 male, 21 female; age range 6-88 (mean, 48) years). Films of 75 of the 80 patients were reread by a nuclear medicine physician who was blinded to the original reading and identity and history of the patient. Results of scans were compared with confirmatory studies. RESULTS: A total of 21 patients had positive scans (28 percent). Of these, the site of bleeding in 16 of 21 patients (76 percent) was confirmed by angiography (4/16), endoscopy (10/16), surgery (10/16), or a combination of these. In 14 of the 16 confirmed studies (88 percent), RBC scan correctly localized site of bleeding by our rigid definition. In six patients (4 not confirmed, 2 erroneously localized), scans were positive only at greater than 15 hours. Ten of the 14 correctly localized studies and none of the incorrectly localized studies were positive in the continuous phase of imaging. CONCLUSION: Tc99m RBC scan is effective in localizing GI bleeding when positive within the continuous phase of imaging. In this population supplemental angiography or endoscopy for the purpose of localization would seem unnecessary.

Adolescent↗

Instant technetium 99m hexamethyl propylenamine oxime-labeled leukocyte scan compared with colonoscopy in early assessment of disease extent and activity in acute colitis.

AIM: This study was undertaken to evaluate technetium 99m (Tc 99m) hexamethyl propylenamine oxime (HMPAO)-labeled leukocyte scintigraphy for assessment of disease extent and activity in acute colitis. PATIENTS AND METHODS: Twenty-seven patients, hospitalized because of acute watery and/or bloody diarrhea, were investigated using both total colonoscopy and Tc 99m HMPAO-labeled leukocyte scintigraphy within 48 hours after admittance. RESULTS: Final diagnoses were ulcerative colitis in 14 patients, Crohn's disease in 7 patients, and infectious colitis in 6 patients. Using colonoscopy as the reference method, the maximum extent of colitis was correctly assessed by the leukocyte scan in 18 patients (67 percent), although rectal engagement was not visualized in 5 (19 percent). In six additional patients, there was almost complete agreement between the two methods. One other patient, with leftsided ulcerative colitis, was erroneously assessed as having total extent. Two other patients (one with Crohn's colitis and one with infectious colitis) had different segments incorrectly assessed. Sensitivity, specificity, and diagnostic accuracy of scintigraphy in detecting active inflammatory segments were 0.85, 0.83, and 0.85, respectively. Intensity of inflammatory activity assessed by the leukocyte scan correlated significantly with colonoscopic assessment (r = 0.719; P < 0.0001). CONCLUSION: Information regarding extent, localization, and disease activity in patients with acute colitis of inflammatory or infectious origin may be satisfactorily obtained using Tc 99m HMPAO-labeled leukocyte scanning. The noninvasive nature of the method makes it an attractive early alternative to other investigational procedures such as total colonoscopy or barium examination, particularly in cases with an established diagnosis of inflammatory bowel disease.

Acute Disease↗

Radioimmunoscintigraphy of recurrent, metastatic, or occult colorectal cancer with technetium Tc 99m 88BV59H21-2V67-66 (HumaSPECT-Tc), a totally human monoclonal antibody. Patient management benefit from a phase III multicenter study.

PURPOSE: The study contained herein was undertaken to evaluate the accuracy of radiolabeled human monoclonal antibody, 88BV59H21-2V67-66 (88BV59 or HumaSPECT-Tc), in predicting disease resectability in presurgical subjects with recurrent, metastatic, or occult colorectal carcinoma. METHODS: A total of 219 patients with disease visualized on computed tomographic scan (recurrent or metastatic disease) or with negative or equivocal computed tomographic scan and rising carcinoembryonic antigen serum levels (occult group) received technetium Tc99m-labeled 88BV59 intravenously. Planar and single photon emission computed tomograhic images were obtained 14 to 20 hours postinfusion, before surgery. The ability of computed tomographic and HumaSPECT-Tc imaging to define the extent of disease and to predict resectability was evaluated based on surgical and histopathologic results. RESULTS: In patients with recurrent or metastatic disease (170 evaluable patients), the accuracy of predicting nonresectability of disease was significantly greater (P < 0.001) for HumaSPECT-Tc than for computed tomography (60 vs 29 percent). Computed tomography understaged 41 percent of patients believed to have resectable disease compared with 27 percent for HumaSPECT-Tc (P < 0.001). In occult disease patients (29 computed tomographic and 28 HumaSPECT-Tc evaluable patients), the overall accuracy of predicting resectability/nonresectability was 6 percent for HumaSPECT-Tc compared with 24 percent from computed tomography. Administration of HumaSPECT-Tc had no effect on monoclonal antibody-based in vitro diagnostic assays. Only a single patient demonstrated an anti-antibody response (90 ng/ml) at nine weeks postinfusion. CONCLUSION: HumaSPECT-Tc was more accurate than computed tomography in determining disease resectability in patients with metastatic, recurrent, or occult cancer. The addition of HumaSPECT-Tc imaging can play a significant role in patient management decisions.

Adult↗