Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Sound”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56Linked to original sources

Distance from an intrauterine hydrophone as a factor affecting intrauterine sound pressure levels produced by the vibroacoustic stimulation test.

OBJECTIVE: The purpose of this study was to determine whether intrauterine sound pressure levels produced by vibroacoustic stimulation were associated with distance from an intrauterine hydrophone in human parturients and to evaluate the effects of distance on the spectrum of the stimulus. STUDY DESIGN: Measurements of intrauterine sound were taken in eight volunteer parturients in normal active-phase labor by use of an intrauterine hydrophone. Vibroacoustic stimulation was performed on the maternal abdomen directly overlying the hydrophone; at distance of 5, 10, 15, 20, and 25 cm from the hydrophone; and at the maternal sternum. Intrauterine sound pressure levels were tape-recorded for later analysis. Fetal heart rate and fetal movement were assessed with each vibroacoustic stimulation. Spectral analyses were performed by taking the fast Fourier transform of the tape-recorded stimulation at each position. RESULTS: Analysis of variance with repeated measures indicated a statistically significant decrease (F = 4.1, p = 0.004) in the sound pressure levels as distance increased. Spectral analysis indicated large variability between and within subjects. CONCLUSION: Sound exposure of the fetal ear is on average decreased as the distance between the ear and the vibroacoustic stimulation is increased. The spectrum of the stimulus produced with vibroacoustic stimulation is highly variable.

Acoustic Stimulation↗

Evaluation of a technique for recording temporomandibular joint sounds.

Analysis of temporomandibular joints sounds may contribute to the differential diagnosis of temporomandibular joint disorders. In this article an advanced system for the recording of joint sounds is presented. The method proved to be reliable. The problem of filtering out artifacts has been solved to a great extent but not completely. Temporomandibular joint sounds measured with this technique vary considerably in energy, frequency spectrum, and peak-to-peak amplitude over 3 months, as well as within 1 day. These differences seem to reflect natural variations in joint sounds caused by the physical impossibility of performing identical jaw movements. The results indicate that joint sound characteristics do not yet offer a solid basis for inferences concerning the development of temporomandibular joint abnormalities in the clinical setting.

Adolescent↗

Acoustic analysis of pathological cries, stridors and coughing sounds in infancy.

In the examination of respiratory pathological sound phenomena in infancy (pathological crying, stridor and coughing sounds), besides the subjective-auditive observations and traditional examination methods (X-ray, endoscopy), acoustic analysis, as a new branch of bioacoustics, may be of much help. The various pathological infant vocalizations originating from the air passageways are merely symptoms, but they may furnish important diagnostic clues. Approximately 200 recordings of pathological sound signals derived from 180 infants suffering from 40 different diseases or anomalies were analyzed by means of sound spectrography, the fundamental frequency meter, and rarely, the minimal-time-interval spectra technique. The acoustical evaluation of the sound phenomena are not only of scientific and documentative value; they are also of great help in diagnostics and prophylaxis, in the suitable choice of diagnostic tools and in education and further training, i.e. in the everyday work of the pediatric otolaryngologist.

Acoustics↗

Electrosonographic characteristics of sounds from temporomandibular joint disc replacement.

The purpose of this study was to investigate the waveform and electrosonographic characteristics of sounds emanating from internal derangement of the temporomandibular joint (TMJ). TMJ sounds were recorded from 10 joints of normal people (NP), 10 joints from patients with anterior disc displacement with reduction (DDR) and 20 joints from patients with anterior disc displacement without reduction (DDNR). The sounds were analyzed through fast Fourier transfer methods to observe their waveforms and electrosonographic characteristics. The observations were then used in differentially diagnosing internal derangement. Wave pattern and electrosonography (ESG) differed among the NP, DDR and DDNR groups. There was very little difference in frequency between the sounds from DDR and DDNR, but the amplitude of the DDR sounds was higher than those of DDNR and NP. The sensitivity and specificity of ESG diagnosis for DDR were 77.2% and 93.3%, respectively, while for DDNR they were 81.6% and 64.7%, respectively.

Adolescent↗

Encoding of sound motion by binaural brainstem units in a Horseshoe bat.

In order to study how and if single brainstem units respond to moving compared with stationary sounds, radially moving sound sources were presented to the bat, Rhinolophus ferrumequinum. This time-variant binaural stimulation was simulated dichotically through earphones (closed-acoustic-field for the virtual azimuth range of +/-40 degrees from the midline). Neurophysiologically recorded responses primarily showed a function of interaural intensity difference (IID) which is considered a direct correlate of the sound source's azimuth angle. However, this is only true for the stationary case. Unit's response did not remain unaffected by the dynamic stimulus cues of sound source movement (velocity and direction). Maximal discharge rate became a function of motion velocity as well as the slopes of the response profiles. Hence, coding of IID became ambiguous as, depending on the unit, the response profiles and therefore a unit's receptive field, became spatially shifted with respect to one another when the direction of the sound source movement was reversed. Shifts within the movement direction (hysteresis) as well as against it (termed here 'advance') were observed: hysteresis is typical for units with non-monotonic, stationary rate/intensity functions, whereas those units with monotonic functions predominantly show advances. Further dynamic response features in form of transient peaks and troughs, superimposed on the response profiles, were registered. It appears that the ongoing firing rate no longer represents azimuth position alone, but vigorously reproduces the dynamic cues (velocity and movement direction), too. With respect to the neural mechanisms leading to dynamic response features, it is proposed that, as long excitation and inhibition act with similar short time constants, neural activity can rapidly and faithfully follow changing IIDs. Different time constants for excitation, inhibition, facilitation, and depression may be responsible for the dynamic 'features' such as transient responses and hysteresis/advance. They may provide biologically relevant information for nocturnally hunting bats to efficiently guide their flight maneuvers.

Animals↗

Dynamics of working memory for moving sounds: an event-related potential and scalp current density study.

Human brain imaging studies have suggested that posterior temporo-parietal regions are involved in auditory spatial processing. We used electroencephalography to investigate the dynamics of temporo-parietal networks during working memory for moving sounds. A delayed matching-to-sample task required a decision on the identity of positions and trajectories of two moving sounds S1 and S2 presented with delays of 927 or 1427 ms. Moving sounds consisted of noise bursts positioned at successive angles to create the impression of one of six possible trajectories at variable spatial positions. Stimuli in the equally difficult control condition were identical to the memory task up to S2, which was replaced by a spatial displacement in the otherwise stationary background sound whose direction had to be detected. Event-related potentials were recorded from 31 scalp electrodes in 15 subjects. Scalp current density estimates allowed to identify the following components. The fronto-central negative variation preceding S2 did not differ between tasks. In contrast, the sustained negative current during the presentation of S1 originating from superior temporal cortex was more pronounced for the memory task, probably reflecting enhanced attention allocation and foreground-background discrimination. Most importantly, the memory task activated current sources over bilateral posterior parietal regions between the middle of S1 and the end of the delay phase. This component was completely absent in the control condition. In summary, the present study disclosed varying degrees of memorization-related, top-down driven influences on the processing of moving sounds at different stages of an auditory network involving temporal and parietal regions.

Acoustic Stimulation↗

A review of learning with normal and altered sound-localization cues in human adults.

Humans use several cues to determine the position of sound sources in space. Here we provide a review of the literature on how practice influences sound-localization performance in human adults. We divided this literature into two categories: adaptation to alterations in sound-localization cues and learning with normal, unaltered cues. For altered cues, partial adaptation has been reported with a variety of cue transformations, except in the extreme case in which the cues were reversed between the two ears. For normal cues, improvement has been observed in some but not all experiments, though the most recent data generally show learning. Thus, the reviewed data indicated that human adults can recalibrate, as well as refine the use of, sound-localization cues, and that training regimens can be developed to enhance sound-localization performance in individuals with normal and impaired localization abilities.

Adult↗

Accessing heart dynamics to estimate durations of heart sounds.

Segmentation of the phonocardiogram into its major sound components is the first step in the automated diagnosis of cardiac abnormalities. Almost all of the existing phonocardiogram segmentation algorithms utilize absolute amplitude or frequency characteristics of heart sounds, which vary from one cardiac cycle to the other and across different patients. The objective of this work is to provide an efficient phonocardiogram segmentation technique, under difficult recording situations, by utilizing the underlying complexity of the dynamical system (heart) giving rise to the heart sound. Complexity-based segmentation is invariant to amplitude and frequency variations of the heart sound and yields better time gates for heart sounds.

Algorithms↗

Attracting attention to the illusory location of a sound: reflexive crossmodal orienting and ventriloquism.

Sound localization can be affected by vision; in the ventriloquism effect, sounds that are hard to localize within hearing become mislocalized toward the location of concurrent visual events. Here we tested whether spatial attention is drawn to the illusory location of a ventriloquized sound. The study exploited our previous finding that visual cues do not attract auditory attention. We report an important exception to this rule; auditory attention can be drawn to the location of a visual cue when it is paired with a concurrent unlocalizable sound, to produce ventriloquism. This demonstrates that crossmodal integration can precede reflexive shifts of attention, with such shifts taking place toward the crossmodally determined illusory location of a sound. It also shows that ventriloquism arises automatically, with objective as well as subjective consequences.

Adolescent↗

Interference cancellation in respiratory sounds via a multiresolution joint time-delay and signal-estimation scheme.

This paper is concerned with the problem of cancellation of heart sounds from the acquired respiratory sounds using a new joint time-delay and signal-estimation (JTDSE) procedure. Multiresolution discrete wavelet transform (DWT) is first applied to decompose the signals into several subbands. To accurately separate the heart sounds from the acquired respiratory sounds, time-delay estimation (TDE) is performed iteratively in each subband using two adaptation mechanisms that minimize the sum of squared errors between these signals. The time delay is updated using a nonlinear adaptation, namely the Levenberg-Marquardt (LM) algorithm, while the function of the other adaptive system-which uses the block fast transversal filter (BFTF)-is to minimize the mean squared error between the outputs of the delay estimator and the adaptive filter. The proposed methodology possesses a number of key benefits such as the incorporation of multiple complementary information at different subbands, robustness in presence of noise, and accuracy in TDE. The scheme is applied to several cases of simulated and actual respiratory sounds under different conditions and the results are compared with those of the standard adaptive filtering. The results showed the promise of the scheme for the TDE and subsequent interference cancellation.

Algorithms↗

Detection of respiratory sounds at the external ear.

Several clinical and ambulatory settings necessitate respiratory monitoring without a mouthpiece or facemask. Several studies have demonstrated the utility of breathing sound measurements performed on the chest or neck to detect airflow. However, there are limitations to skin surface measurements, including susceptibility to external noise and transducer motion. Thus, this two-part study investigated a novel location for breathing sound measurements: the external ear. The first study investigated characteristics of sound transmission from the oropharynx to the external ear in 19 adults (nine males). Broadband noise was directed into the oropharynx through a tube and mouthpiece and measured indirectly via an accelerometer affixed to the cheek. Resultant transmission to the external ear was measured with a microphone inserted into an earplug that provided acoustic isolation from ambient noise. Near-unity coherence estimates (> 0.9) between the sounds recorded at the external ear and the oropharynx were observed up to approximately 800 Hz, indicating a low-frequency region of preferred transmission. In the second study, each of 20 subjects (nine males) breathed through a pneumotachograph at targeted shallow (3.0 mL/s/kg) and tidal (7.5 mL/s/kg) flows normalized to body mass, and the resulting sounds were recorded at the external ear. Recordings during breath hold measured background noise. Shallow and tidal expiratory flows, respectively, produced signal-plus-noise-to-noise [(S + N)/N] ratios of 6.7 +/- 4.1 dB and 14.0 +/- 5.3 dB (mean +/- standard deviation) across all subjects between 150 and 300 Hz. Concurrent inspiration demonstrated (S + N)/N ratios of 6.6 +/- 3.9 dB and 14.9 +/- 6.3 dB. Thus, the external ear shows promise as an anatomic site to detect and monitor breathing in a relatively noninvasive and unobtrusive manner.

Adolescent↗

Spectral shape discrimination of narrow-band sounds.

Measurements are reported on the detectability of signals added to narrow-band sounds. The narrow-band sounds had a bandwidth of 20 Hz and were either Gaussian noise with flat amplitude spectra or sets of equal-amplitude sinusoidal components whose phases were chosen at random. Four different kinds of sinusoidal signals were used. Two signals produced symmetric changes in the audio spectrum adding a component either at the center of the spectrum or at both ends. The other two signals produced asymmetric changes adding a component at either end of the spectrum. The overall level of the sound was randomly varied on each presentation, so that the presence of a signal was largely unrelated to the absolute level of the signal component(s). A model is proposed that assumes the detection of the symmetric signals is based on changes in the shape of the power spectrum of the envelope. Such changes in the envelope power spectrum are probably heard as changes in the "roughness" or "smoothness" of the narrow-band sound. The predictions of this model were obtained from computer simulations. For the asymmetric signals, the most probable detection cues were changes in the pitch of the narrow-band sound. Results from a variety of different experiments using three listeners support these conjectures.

Adult↗

Locating animals from their sounds and tomography of the atmosphere: experimental demonstration.

Calling animals are located using widely distributed receivers, and the sounds from the animals are used to map the sound speed and wind fields by means of tomography. In particular, two Red-Winged Blackbirds Agelaius phoeniceus are correctly located within a meter using recordings from five receivers spread over a 20 by 30 m region. The demonstration hinges on two new developments. First, a new algorithm for blindly estimating the impulse response of the channel is shown capable of estimating the differences in the time of first arrivals at two receivers. Since it is known that the first arrivals travel along nearly straight paths, the difference in time constrains the animal's location to a hyperboloid, and the animal is located by intersecting hyperboloids from many pairs of receivers. Second, in order to accurately find the intersection point and map the sound speed and wind fields using tomography, a nonlinear equation is solved. The new algorithm for blindly estimating the impulse response of a channel offers a new way for locating sounds and making tomographic maps of the environment without any requirement for a model for the propagation of sound such as is needed for focalization and matched field processing.

Algorithms↗

Comparison of lung sound transducers using a bioacoustic transducer testing system.

Sensors used for lung sound research are generally designed by the investigators or adapted from devices used in related fields. Their relative characteristics have never been defined. We employed an artificial chest wall with a viscoelastic surface and a white noise signal generator as a stable source of sound to compare the frequency response and pulse waveform reproduction of a selection of devices used for lung sound research. We used spectral estimation techniques to determine frequency response and cross-correlation of pulses to determine pulse shape fidelity. The sensors evaluated were the Siemens EMT 25 C accelerometer (Siemens); PPG 201 accelerometer (PPG); Sony ECM-T150 electret condenser microphone with air coupler (air coupler; with cylindrical air chambers of 5-, 10-, and 15-mm diameter and conical air chamber of 10-mm diameter); Littman classic stethoscope head (Littman) connected to an electret condenser microphone; and the Andries Tek (Andries) electronic stethoscope. We found that the size and shape of the air coupler chamber to have no important effect on the detected sound. The Siemens, air coupler, and Littman performed similarly with relatively flat frequency responses from 200 to 1,200 Hz. The PPG had the broadest frequency response, with useful sensitivity extending to 4,000 Hz. The Andries' frequency response was the poorest above 1,000 Hz. Accuracy in reproducing pulses roughly corresponded with the high-frequency sensitivity of the sensors. We conclude that there are important differences among commonly used lung sound sensors that have to be defined to allow the comparison of data from different laboratories.

Acoustics↗

Sensitivity of auditory cortical neurons to the locations of leading and lagging sounds.

We recorded unit activity in the auditory cortex (fields A1, A2, and PAF) of anesthetized cats while presenting paired clicks with variable locations and interstimulus delays (ISDs). In human listeners, such sounds elicit the precedence effect, in which localization of the lagging sound is impaired at ISDs less, similar10 ms. In the present study, neurons typically responded to the leading stimulus with a brief burst of spikes, followed by suppression lasting 100-200 ms. At an ISD of 20 ms, at which listeners report a distinct lagging sound, only 12% of units showed discrete lagging responses. Long-lasting suppression was found in all sampled cortical fields, for all leading and lagging locations, and at all sound levels. Recordings from awake cats confirmed this long-lasting suppression in the absence of anesthesia, although recovery from suppression was faster in the awake state. Despite the lack of discrete lagging responses at delays of 1-20 ms, the spike patterns of 40% of units varied systematically with ISD, suggesting that many neurons represent lagging sounds implicitly in their temporal firing patterns rather than explicitly in discrete responses. We estimated the amount of location-related information transmitted by spike patterns at delays of 1-16 ms under conditions in which we varied only the leading location or only the lagging location. Consistent with human psychophysical results, transmission of information about the leading location was high at all ISDs. Unlike listeners, however, transmission of information about the lagging location remained low, even at ISDs of 12-16 ms.

Acoustic Stimulation↗

Tracheal sound spectra depend on body height.

Tracheal sounds originate from turbulent flow in upper and central airways. Turbulent flow characteristics are influenced by conduit dimensions. Because tracheal dimensions are a function of body height, we hypothesized that there should be a correlation between sound spectra and body length. We recorded tracheal sounds at standardized airflows in 21 healthy children 9.1 +/- 0.6 yr of age (mean +/- SE) and in 24 healthy adults 30.2 +/- 0.8 yr of age. A contact sensor was attached at the suprasternal notch of the sitting subject, and airflow was measured at the mouth with a calibrated pneumotachograph. Tracheal sounds were low-pass-filtered at 2.4 kHz and digitized at 10 kHz. A 2048 point FFT was applied at a successive 100-ms intervals, using a Hanning data window. Resulting spectra were normalized to a reference power of 0.1 (mV)2/5 Hz. We applied a gating algorithm to extract sounds at inspiratory flows of 1 L/s (+/- 10% tolerance), and we computed average power spectra from the collected samples. We calculated the average spectral power (Pavg), the quartile frequencies below which 25% (Q1), 50% (Q2), and 75% (Q3) of the power in the range of 50 to 2,000 Hz was contained, the spectral edge frequency (SE95) below which 95% of the power was found, and the frequency where spectral power rolled off sharply (Fcut).(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Power spectral analysis of temporomandibular joint sounds in asymptomatic subjects.

Very little has been done to quantify temporomandibular joint (TMJ) sound amplitudes and background noise and to determine the spectrum from healthy TMJs. Thus, the aim of this study was to record acoustically the sounds emitted by healthy TMJs with and without mandibular movements, for determination of baseline spectra. TMJ sounds were recorded bilaterally from 40 subjects with healthy joints by means of a self-developed recording system using miniature capacitor microphones inserted into the earpieces of a medical stethoscope placed in the meatus of the auditory canal. The recordings were performed without mandibular movements and during three consecutive opening and closing movements. The signals were high-pass-filtered at 50 Hz, low-pass-filtered at 2 kHz, and analyzed by fast Fourier transform computation on a 1024-point window (fs = 5 kHz). The linearly weighted average baseline spectrum recorded without motion showed maximum values of 31 dBSPL (sound pressure level) with a standard error of +2 to -3 dB. The linearly weighted average movement spectrum had a peak of 66 dBSPL at 156 Hz and decreased almost linearly by about 40 dB/decade to 25 dBSPL at 2000 Hz with a standard error of +/- 2 dB. Thus, the TMJ sound spectrum of mandibular movements in asymptomatic subjects differed at low frequencies by up to 35 dB from the baseline spectrum in absence of motion.

Adolescent↗

Frequency spectra of normal breath sounds in childhood.

Clinicians who auscultate the chest of normal children note that the frequency content of their breath sounds appears to vary with age. Because these changes have not been systematically documented before, we recorded and analyzed inspiratory breath sounds in 35 children (0 to 13 years) and five adults (34 to 43 years). Our objective was to determine if the frequency content of normal breath sounds differed with age. Using a Fast Fourier Transform program, we calculated an average amplitude frequency spectrum from the inspiratory portion of the breath sounds of each subject (n = 10 breaths), and we compared the shape of the AFS and the values of selected frequency parameters. We found that the shape of the AFS of the youngest children differed most from the AFS of adults. Three of four selected frequency parameters (F25, F50, F95) differed significantly between children and adults (p less than 0.05), and one parameter (F75) did not (p = 0.11). The F25, F50, and F75 parameters of children (but not F95) were correlated (p less than 0.001) with increasing height and age. These results suggest that differences in the frequency content of the normal breath sounds of children and adults contribute to the differences that clinicians detect during clinical auscultation.

Adult↗