Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “STETHOSCOPE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56Linked to original sources

[Anesthetic care for fibrobronchoscopy in patients with chronic terminal respiratory insufficiency undergoing evaluation for isolated lung transplantation].

During the first 18 month operation of the isolated lung transplantation program at or Institution, eight patients with terminal chronic respiratory failure underwent fiberoptic bronchoscopy and broncho-alveolar lavage as part of their evaluation for isolated lung transplantation. Four patients had severe obstructive, three restrictive, and one mixed, obstructive and restrictive, disease; all of them were on continuous supplemental oxygen. Procedures were performed under topical anaesthesia, with either light sedation or simple monitored anaesthesia care. Monitoring included non-invasive blood pressure measurement, pulse oximeter and precordial stethoscope. No adverse events were recorded, except in one case, when pulse oximeter reading precipitously dropped below 80%, to a minimum of 68-69%. The procedures was terminated short of its completion, and the patient was briefly assisted with manual bag ventilation on oxygen 100%. Pulse oximeter quickly returned to normal levels (above 90%), and the patient promptly recovered, without complications. The importance of monitored anaesthesia care during fiberoptic bronchoscopy (a usually benign procedure) in critically ill patients is greatly emphasized.

Adult↗

Chest tube stripping in pediatric oncology patients: an experimental study.

BACKGROUND: Stripping of chest tubes to promote drainage of the thorax of postthoracotomy patients has been routine practice, based on tradition. Recent published findings indicate that significant negative pressures are generated in the tube during stripping that could cause pain, bleeding and possible damage to the patient's lung tissue. OBJECTIVE: To determine whether pediatric oncology patients whose chest tubes were not stripped would differ in frequency of pain, fever or lung complications from patients who underwent routine tube stripping. METHODS: Data were collected at multiple points during the first 72-hour postoperative period from 16 patients assigned to the stripped or unstripped groups. Pain was measured by the Faces Pain Scale and the Visual Analogue Scale; temperature, by electronic thermometer; and lung complications, by stethoscope and radiographs. Both groups, which were comparable for age, primary diagnosis and prior history of lung problems, received identical supportive nursing and medical care, with the physicians blind to group assignment. RESULTS: The two groups did not differ significantly in frequency of pain, incidence of fever, breath sounds or radiographic findings across measurement points. A strong correlation was found between the pain scores using the two instruments. DISCUSSION: Patients whose tubes were not stripped did not have an increased risk of infection or lung complications. Study findings indicated that stripping did not increase the frequency of pain. CONCLUSIONS: Stripping of chest tubes as a routine postoperative measure is questioned.

Adolescent↗

[An innovative thoracoscopic surgery for patient ductus arteriosus--a Japanese first case report].

A five-year-old girl with patent ductus arteriosus (PDA) was successfully treated by thoracoscopic surgery, which was the first successful case in Japan. The operation was carried out under general anesthesia with usual endotracheal intubation. Short trocars were inserted through the left intercostal spaces to introduce a flexible video thoracoscope and adequate surgical instruments. After the ductus was carefully dissected and exposed, two titanium clips which were 11 mm in length were applied to interrupt the ductus completely. The continuous heart murmur of PDA was confirmed to disappear by an esophageal stethoscope. Postoperative course was uneventful and the patient was discharged on 6 postoperative day. No residual PDA shunt was revealed by doppler echocardiogram 8 months after surgery. The advantages of thoracoscopic surgery for PDA are: less postoperative pain and discomfort, early recovery and short hospital stay, and cosmetic preservation. Availability of smaller sized surgical instruments should allow this method indicated for smaller children or newborns with PDA.

Child, Preschool↗

Comparison of the effect of insulated and noninsulated head covers on heat loss during abdominal surgery.

Hypothermia is experienced by all patients undergoing major surgical procedures. Hypothermia can lead to postoperative complications affecting oxygenation with neurologic, immunologic, and metabolic consequences. Current methods of heat conservation used in the operating room include blanket warmers, fluid warmers, and anesthesia circuit warmers. These methods are often inadequate at maintaining a patient's body temperature. The current study used a post-test-only control group design. Subjects in the treatment group had an insulated head cover applied within 1 minute of arrival in the operating room, while those in the control group did not. All subjects had routine heat conservation measures (blanket warmers, fluid warmers, and anesthesia circuit humidifiers). Following induction of anesthesia, subjects' temperatures were measured using an esophageal stethoscope with thermistor probe at 10 and 70 minutes. Results showed no significant differences between groups at either time point.

Adult↗

A comparison of conventional versus electronic monitoring of sedated pediatric dental patients.

The first purpose of this study was to compare traditional monitoring methods to electronic instruments for monitoring physiologic parameters during conscious sedation of pediatric dental patients. Traditional methods included careful visual assessment of skin color, airway patency and chest movements, and auscultation of breath and heart sounds using a precordial stethoscope; electronic instruments included the capnograph and pulse oximeter. The second purpose of the study was to examine the potential of the capnograph to provide more advanced warning than the pulse oximeter for respiratory compromise. Thirty-nine children (mean age 39 months) received an oral sedative regimen of chloral hydrate, hydroxyzine pamoate, and meperidine and all were supplemented with 100% oxygen via nasal cannula throughout their sedations. One investigator used traditional monitoring and the other used electronic--both monitored simultaneously while being shielded (blinded) from each other. Electronic monitoring yielded a false alert rate of 88% compared with 73% for traditional monitoring. Ten confirmed episodes of respiratory compromise were identified electronically and only three were identified by traditional monitoring. All of the 10 confirmed respiratory compromise episodes were detected by capnography; none were detected by oximetry. During these 39 pediatric sedations using a narcotic drug regimen and 100% oxygen supplementation, there were no true desaturations.

Anesthesia, Dental↗

[Prevalence and sociocultural and economic aspects of hypertension in a health center of the northern area of Manaus].

PURPOSE: To verify the prevalence and the possible sociocultural and economic factors involved in high blood pressure (HBP), intending to contribute to the elaboration of public health programs. METHODS: The blood pressure of 1,766 individuals, aging 13 years old or more, was measured by the auscultatory method, using a stethoscope and a sfigmomanometer. It was included in the HBP group, the individual presenting blood pressure above 140 x 90 mmHg in two measurements on different occasions. These individuals answered a form searching for sociocultural and economic aspects. RESULTS: Among the individuals examined, 76 were considered to have HBP. There was an increase on the prevalence of HBP with an increase of age, being the greatest among the individuals aging 49 years or more. It was observed significant association between age and HBP (p < 0.05), but the same did not happen with sex or skin color. In most part of the individuals with HBP, it was observed low family income and low educational level. Half of the HBP patients were used to eat with salt and fat. CONCLUSION: The educational level, economic status, and sociocultural habits of a person constitute factors that must be considered in the development of public health programs for control and reduction of the prevalence of HBP.

Adolescent↗

Devices for blood pressure self measurement: tested in comparison.

OBJECTIVE: Comparative clinical evaluation of instruments designed for the self-measurement of blood pressure. METHOD: The usefulness of 27 different, exclusively oscillometric, automated devices were tested on a single group of 24 test persons without pressure-reducing arterial stenoses in the upper extremity. The cuff was to be put on the upper arm with 20 devices, on the wrist with five devices and on the left index finger with two devices. Per device and test person, six sequential comparative measurements were carried out using automated self-measurement and standard method with a double stethoscope in the same arm. RESULTS: On average, the devices measured the systolic pressure between 13.2 mmHg lower and 3.5 mmHg higher than the standard procedure; the diastolic pressure was measured between 17.4 and 0.2 mmHg lower. Using a scoring system, in which a device only got points for a comparative measurement if the differences to the control in systolic and diastolic measurement both were < or = 10 mmHg, the devices gained between 67 and 259 out of a maximum of 576 points. If each of the test persons had opted to buy just those devices which revealed a mean systolic and diastolic error of < or = 5 mmHg in his or her case, younger test persons would have found zero to five suitable devices older persons three to 13. The site of cuff application had no significant influence on results. CONCLUSIONS: Standard measurements and measurements with automated blood pressure self-measurement devices can differ considerably. In young test persons less suitable instruments are found than for older persons.

Adult↗

A new audiovisual technique for recording blood pressure in research: the Sphygmocorder.

OBJECTIVE: To devise a method of blood pressure measurement capable of being substituted for the fallible human observer in validation of blood pressure measuring devices. DESIGN: A number of components used to measure blood pressure have been combined innovatively with audiovisual recording technology to produce a system, named the Sphygmocorder, which consists of a mercury sphygmomanometer, an occluding cuff, an inflation source, a stethoscope, a microphone capable of detecting Korotkoff sounds, a camcorder and a display screen. METHODS: To determine the accuracy of the Sphygmocorder against the trained human observer, the Sphygmocorder has been validated in three separate studies in which three devices for self-measurement of blood pressure, the Omron HEM-705CP, the Phillips HP5332 and the Nissei DS-175, were being validated against two trained observers in 85 subjects with a wide range of blood pressure according to the protocol of the British Hypertension Society. RESULTS: The Sphygmocorder was as accurate as at least one of the observers in each of the validation studies and therefore allows replacement of trained observers by the new device. CONCLUSION: The Sphygmocorder, which retains the time-honoured technique of blood pressure measurement with a mercury sphygmomanometer and an auscultating observer, and provides, in addition, objective evidence of the measurement recorded, which can be stored and re-examined, can be used as a substitute for human observers in validation studies of blood pressure-measuring devices.

Blood Pressure Determination↗

Commentary on equipment recommendations.

The international standards for safe anaesthesia may all be satisfied with relatively limited resources. General standards deal with clinical and administrative autonomy, peer review, training, clinical practice and the role and working conditions of the anaesthetist. Additional recommendations deal with suggestions for the progressive acquisition of equipment and monitors as resources allow. These include: a light source, thermometer, sphygmomanometer and stethoscope, with an oxygen analyser if nitrous oxide is to be used, and a disconnect alarm if a ventilator is to be used (basic requirements); a low pressure oxygen supply failure alarm, devices mitigating against the supply of hypoxic gas mixtures, oximeter, capnograph, electrocardiograph and defibrillator (highly recommended); a spirometer, neuromuscular junction monitor and electronic thermometer (recommended); and finally devices such as volatile agent monitors and invasive blood pressure monitors for areas with ample resources.

Anesthesiology↗

Relationship between dyspnea, peak expiratory flow rate and wheeze in obstructive lung disease.

The relationship between dyspnea and airway obstruction is complex, and it is unclear to what extent measures of each correlate in patients with obstructive lung disease (OLD). Thus, the correlation between subjective assessment of dyspnea (dyspnea score using modified Borg scale) and objective assessment of dyspnea (peak expiratory flow rate using Mini Wright Peak Flow Meter and wheeze score using stethoscope) before and after bronchodilator (1 mg of turbutaline sulphate) were studied in 115 patients (62 males, 53 females) with OLD attending the chest clinic of Royal Irrigation Hospital, Nonthaburi, Thailand. The mean age of these patients was 47.4 +/- 16.4 years. Good correlations were found (r = 0.37 to 0.52; p < 0.001) but dyspnea scores were better correlated with wheeze scores than peak expiratory flow rates. The change in dyspnea scores after bronchodilator also correlated with the change in peak expiratory flow rates and the change in wheeze scores (r = 0.22; p < 0.02 and r = 0.28; p < 0.005 respectively). Analyzing a subgroup of 48 dyspneic patients (prebronchodilator dyspnea score of 2 or more) revealed the following response groups: those with either a bronchodilator or dyspnea response alone, both together, or neither. Twenty-three patients (47.92 per cent) responded both subjectively and objectively. One (2.08 per cent) had a bronchodilator response only. Twenty (41.66 per cent) had a dyspnea response only, while four (8.33 per cent) had neither measurable response. The present study suggests that the assessment of dyspnea by using dyspnea score is vital and may be specially helpful in a situation where the objective assessment cannot be performed. In some individuals the subjective assessment of response to bronchodilator may be at least as valuable as objective data.

Adolescent↗

[A new video-assisted thoracoscopic surgical interruption of patent ductus arteriosus].

A new video-assisted thoracoscopic surgery was applied to patients with patent ductus arteriosus (PDA). After the ductus was carefully dissected and exposed, two or one titanium clips which were 11 mm in length were used to interrupt the ductus completely. Eight patients with PDA were successfully treated by the new technique between July 1992 and September 1993, which was the first successful series in Japan. Mean age was 4.3 years (range 1.7 approximately 6.7 years) and mean weight was 15.6 kg (range 10.0 approximately 24.0 kg). All patients had immediate complete PDA closure after the procedure which was proved to be successful by an esophageal stethoscope and color doppler echocardiogram. One patient had mild left recurrent laryngeal nerve dysfunction which was completely cured on 7th postoperative day. There were no other complications and the usual hospital stay was 4 or 5 days. No residual PDA shunt in all cases was revealed by color doppler echocardiogram during follow-up periods (range 3 approximately 12 months). The advantages of thoracoscopic surgery for PDA are: less postoperative pain and discomfort, early recovery and short hospital stay, and cosmetic preservation. Availability of smaller sized surgical instruments should allow this technique indicated for smaller children and premature infants.

Child↗

Prevention, not just treatment.

A tragic burden of disease, disability, and death has resulted from smoking. The role of pulmonary rehabilitation is not only in treatment and rehabilitation of lung disease but in the prevention of lung disease. The skills of the pulmonary rehabilitation specialist should be used in the earlier detection and prevention of lung disease through primary and secondary prevention. The spirometer must gain acceptance in the medical community as the early tool to evaluate lung health, not the chest radiograph or the stethoscope. The lung age formula and sputum pap smears are just a few of the evaluation tools used to detect and motivate susceptible individuals. Prevention is the key to enhancing lung health.

Health Behavior↗

[Continuous intra-arterial blood gas monitoring during bronchopulmonary lavage for pulmonary alveolar proteinosis].

We report a clinical experience of continuous intra-arterial blood gas monitoring (PARATREND 7:P 7) during bronchopulmonary lavage. A 47-year-old, 86-kg male was suffering from myelodysplastic syndrome associated with alveolar proteinosis. Bronchopulmonary lavage was scheduled to alleviate the symptom. P 7 and a continuous cardiac output monitor were used with an EKG monitor, a pulse oximeter, and a esophageal stethoscope. Anesthesia was maintained using sevoflurane and fentanyl. The patient's trachea was intubated with a double-lumen endobronchial tube (39-F Broncho-cath; Mallinckrodt, Ireland). After denitrogenation and degassing, warmed isotonic saline was infused into his left lung. The volume chosen was 2,200 ml which approximated the sum of the patient's functional residual capacity and tidal volume. The lowest point of PO2 appeared at the point 'degassed'. P 7 showed a consecutive rise of PO2 associated with infusion of large volume of saline. Although the response to change in PO2 of P 7 is slower than pulse oximeter, frequent blood sampling can be avoided. We think that P 7 with pulse oximeter are useful for the safe management of pulmonary lung lavage.

Anesthesia, Intravenous↗

[Did pneumococcal endocarditis come back?].

Endocarditis caused by pneumococci represents 1-5% of all cases of endocarditis according to publications from different western countries. Necropsy studies show frequencies of up to 14% of all cases of endocarditis. It usually occurs as a complication to a pneumococcal pneumonia but other foci might be seen. Concomitant meningitis is seen in 20-85% of patients suffering from pneumococcal endocarditis. By knowing this disease entity there is a good possibility for treatment with antibiotics and valve replacement, but if overlooked the mortality is high. The frequency of pneumococcal endocarditis might be underestimated. Careful stethoscopic examination for heart murmurs should be a part of the clinical examination in case of invasive pneumococcal disease, especially with concomitant meningitis. Since bacteriaemia due to pneumococci is diagnosed with increasing frequency in many Northern European countries, special attention should be paid to pneumococcal endocarditis. The literature is reviewed with reference to pathology, pathogenesis, frequency, clinical presentation, diagnosis, treatment and prognosis.

Endocarditis, Bacterial↗

Challenging questions in treating bronchitis.

Whatever facts we gather and no matter how many we have, you and I must eventually put the journal down and pick up our stethoscope, pen, and prescription pad and go to work. Hopefully we can do better than, "Therapy is not uniform and specific antibiotic regimens are usually selected based on local tribal custom." We can discard an old paradigm, "The absence of data bears no relation to the strength of opinion." Personally, I have used these new scientific data before I reached my conclusion. I have developed 10 points to structure my new approach. I invite you to compare my conclusions to yours. 1. In acute bronchitis, in otherwise healthy adults, my preference is to not prescribe an antibiotic. If I do, it is not over the phone. You should want to see and examine the patient. If there are no helpful hints to etiology, I choose a newer macrolide for those under age 50 and use a short course, five-seven days. For patients over age 50, especially if they are "healthy smokers," consider a short course of cefuroxime. (You can see, even in these acute bronchitis patients, you want an antibiotic effective against today's pathogens.) 2. In all chronic bronchitis patients, prevention of further damage to the airways should be attempted by instituting a program of smoking cessation and appropriate immunizations against influenza and pneumococcus. 3. Treatment outcomes will also improve if we recognize that in some patients the progressing SOB, cough, and increasing sputum production are due to congestive heart failure and not due to infection. I try to think about congestive heart failure in all of my patients, but especially in those with known heart disease and cardiomegaly on their chest x-ray. 4. Routine pulmonary function testing is important in smoking patients. Physicians underestimate the degree of obstruction present when they rely on physical exam alone. Hopefully long before the patient's acute illness you have established whether or not obstruction is present. This information helps identify the high risk patient for not only recurrent bouts of infection but also those at increased risk for lung cancer. 5. We will have more success in treating AECB when we elect to use an antibiotic only for patients with at least two of the following three cardinal symptoms: increased dyspnea, increased sputum production, and increased purulent sputum. COPD patients have many days when they feel more SOB. To use this or any one sign as the sole indication for starting an antibiotic has been proven not to make a statistically significant difference in outcome in most patients. Also, the value of prophylactic antibiotic therapy has not been established. 6. When airflow obstruction is moderately severe or more pronounced, AECB should usually be treated with oral steroids. Other measures such as chronic bronchodilator therapy, supplemental and home oxygen use, and pulmonary rehabilitation have been extensively reviewed elsewhere.

Acute Disease↗

A new fetoscope.

Explore the source record for details and available documents.

Fetoscopes↗