Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RADIOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56Linked to original sources

Graded stress radiography of injured anterior cruciate ligaments.

Fifty-five patients with clinical suspicion of injury to their anterior cruciate ligament (ACL) were examined by graded stress radiography before arthroscopic verification in an effort to determine the loss of ACL function as a result of ligament tearing. Using a commercially available stress device capable of applying varying pressures to the mid-calf, anterior drawers were measured from lateral radiographs at 0-, 7-, 14-, and 21-kiloPascal pressures and used to calculate the equivalent elastic modulus of the remaining ACL fibers. According to viscoelastic theory, this modulus is proportional to the number of elastically active fibers in the ligament. To verify the validity of this concept, the stress-strain relationship of a freshly excised ACL ligament was examined in a tensile testing machine, and the procedure was repeated after the ligament had been partially transsected with a scalpel. Comparison with the elastic modulus of the (intact) ACL of the opposite knee permits an estimate of the percentage of rupture in cases of partial tears. Overstretched ligaments show essentially normal viscoelastic properties once the slack in the ligament has been taken up. Complete tears, on the other hand, show a complete breakdown in the viscoelastic properties of the ACL. The results show that partial tears can be diagnosed by graded stress radiography with a sensitivity of 20% and specificity of 90%. Diagnosis of overstretched ligaments had sensitivity of 50% and specificity of 94%. Complete tears were detected with sensitivity of 88% and specificity of 75% as diagnosed against all other ACL lesions and including normals.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Scatter compensation for digital chest radiography using maximum likelihood expectation maximization.

RATIONALE AND OBJECTIVES: An iterative maximum likelihood expectation maximization algorithm (MLEM) has been developed for scatter compensation in chest radiography. METHODS: The MLEM technique produces a scatter-reduced image which maximizes the probability of observing the measured image. We examined the scatter content and the low-contrast signal-to-noise ratio (SNR) in digital radiographs of anatomical phantoms before and after compensation. RESULTS: MLEM converged to an accurate (6.4% RMS residual scatter error) estimate within 12 iterations. Both contrast and noise were increased in the processed images as iteration progressed. In the lung, contrast was increased 108% and SNR was improved by 10%. In the retrocardiac region, contrast was increased 180% while SNR decreased by 6%. CONCLUSIONS: This is the first report of a post-acquisition scatter compensation technique which can increase SNR. These results suggest that statistical estimation techniques can enhance image quality and quantitative accuracy for digital chest radiography.

Algorithms↗

Effectiveness of antiscatter grids in digital radiography. A phantom study.

INTRODUCTION: With ever-increasing interest in bedside radiography using digital imaging techniques, one question often asked is whether and which antiscatter grid should be used to reduce the effects of scattered radiation. In this article, the authors quantitatively analyze and compare images obtained with a flexible circular hole (FCH) grid, a conventional 6:1 focused grid, or without a grid. METHODS: Scatter-to-primary ratios (SPRs), contrast signals, and contrast-to-noise ratios (CNRs) were measured for fixed patient exposure and were compared at various locations in the images of an anthropomorphic chest phantom. RESULTS: Although both grids resulted in greater contrast signals, a significant improvement of the CNR was achieved only in the upper and middle mediastinum regions when the conventional grid was used. With the FCH grid, the CNR is degraded at most locations in the chest image. DISCUSSION: Our results indicate that at fixed exposure level, the use of either grid yields only marginal improvement, at best, in bedside digital chest radiography.

Humans↗

Optimal beam quality for chest computed radiography.

RATIONALE AND OBJECTIVES: Optimal x-ray beam quality for chest computed radiography (CR) has not been determined. To investigate the optimal beam quality for chest CR, the authors measured the radiographic contrasts and compared the image quality of chest CR and screen-film (SF) radiographs using various x-ray tube voltages. METHODS: Chest CR and SF radiographs were obtained on a phantom lung and human volunteers with or without a variety of simulated lung opacities using various x-ray tube voltage levels. Exposures were set to maintain identical patient exposure doses for all images. The contrast between peripheral lung and rib or heart was measured on these images and the differences were compared. The quality of the images of each simulated opacity was evaluated by five radiologists using a five-point grading scale. RESULTS: Contrast between peripheral lung and rib or heart increased on CR images obtained by lowering the tube voltage from 140 to 80 kV, but the degree of increase was less than half the increase on SF images. The CR images of the simulated opacities obtained using a lower tube voltage were judged to be superior to those obtained with a higher tube voltage. Scattered radiation was reduced on CR images with a lower tube voltage. CONCLUSION: The image quality of chest CR was improved by using a lower tube voltage than that used for conventional SF chest radiography. Considering the problem of tube loading in clinical applications, a tube voltage of 100 kV is recommended for chest CR.

Evaluation Studies as Topic↗

Detection of simulated chest lesions with normal and reduced radiation dose: comparison of conventional screen-film radiography and a flat-panel x-ray detector based on amorphous silicon.

RATIONALE AND OBJECTIVES: The authors compared a solid-state amorphous silicon (a-Si) detector and screen-film radiography (SFR) with regard to the detection of simulated pulmonary lesions. Evaluation of the impact of a dose reduction of 50% with this digital flat-panel detector was of special interest. METHODS: A self-scanning flat-panel detector, based on a-Si technology with 143 x 143 microm pixel size, 1 k x 1 k matrix and 12-bit digital output was used. An asymmetric state-of-the-art screen-film system was compared with a-Si images taken at the same dose as SFR-images and at a dose reduced by 50%. An anthropomorphic chest phantom was superimposed by templates containing nodules, linear structures, reticular, and micronodular opacities in a random distribution. Receiver operating characteristic analysis was performed for 23,040 observations made by four independent observers. Student's t test (95% confidence-level) was used for statistical analysis. RESULTS: Receiver operating characteristic analysis showed that a-Si images taken at the same dose as SFR-images were significantly superior to SFR with respect to the detectability of lines (P = 0.01) and micronodular opacities (P < 0.01). For the other objects and the a-Si images taken at a reduced dose, it yielded no statistically significant differences between both imaging modalities. CONCLUSIONS: The results of this phantom study indicate that a-Si detector technology holds promise in terms of dose reduction in chest radiography without loss of diagnostic accuracy compared with SFR.

Humans↗

An observation of the healing process of periapical lesions by digital subtraction radiography.

The purpose of this study was to evaluate the efficacy of digital subtraction radiography using a direct digital imaging system in the follow-up study of endodontically treated teeth. The RVG-S was used as a direct digital imaging system. The intraimage variation of the original RVG-S image caused by dark current and sensitivity variations among pixels was corrected by pixel-to-pixel. The interimage variation was further corrected using a copper step-wedge attached to the sensor. Standardized images were obtained from the same geometrical setup during the follow-up. Pixel values at the regions of interest positioned on the periapical lesion increased after the endodontic treatment, and this change continued during the observation period up to 545 days. The subtraction method with direct digital radiography will be a useful tool to evaluate the healing process in endodontic treatments.

Adult↗

The value of plain radiography in establishing the diagnosis of gastric lesions.

Appreciation for the diagnostic value of plain (noncontrast) radiography of the gastrointestinal tract appears to have diminished with the advent of more sophisticated imaging techniques. A case in which scrutiny of the gastric air pattern on plain abdominal films suggested the underlying presence of Zollinger-Ellison syndrome emphasizes the potential diagnostic value of plain radiography of the abdomen for gastric disorders.

Female↗

Pelvic radiography in blunt trauma resuscitation: a diminishing role.

BACKGROUND: An anteroposterior pelvic radiograph (PXR) continues to be recommended by Advanced Trauma Life Support protocol as an early diagnostic adjunct in the resuscitation of blunt trauma patients. At the same time, computed tomographic (CT) scanning has become a practice standard for diagnosis of most abdominal and pelvic injury. The objective of this study was to determine the necessity of obtaining an early PXR in stable trauma patients who will undergo CT scanning during the initial resuscitation. METHODS: A retrospective review of all blunt trauma patients undergoing immediate abdomen and pelvic CT scanning was performed from July 2000 until June 2001 at an urban Level I trauma center. These patients were divided into two groups depending on whether they also received a PXR (group I) or not (group II). At the time of the study, there was no formal protocol to determine which patients underwent pelvic radiography. Radiology reports of all PXRs and CT scans were reviewed. Patient demographics and Injury Severity Scores (ISSs) were abstracted from our trauma registry. The data were analyzed using Student's test. RESULTS: A total of 686 patients with blunt trauma underwent CT scanning of the abdomen and pelvis. Group I consisted of 311 (45%) patients with an average ISS of 12.3 +/- 0.7. In group I, 56 (10%) patients were found to have at least one pelvic fracture on CT scan, 38 of which were also identified on the PXR. Defining CT scanning as the definitive test, the sensitivity and specificity of the PXR in group I was 68% and 98%, respectively. The false-negative rate for pelvic radiography was 32%. In all patients with a positive PXR, the majority (55%) had either additional fractures or an increase in the Young and Burgess grade of fracture diagnosed on CT scan. Group II consisted of 375 patients, with 16 fractures noted in 13 (3%) patients, none of which required treatment. The mean ISS of group II was 8.0 +/- 0.5. CONCLUSION: The PXR has limited sensitivity for detecting pelvic fractures compared with CT scanning. Selected hemodynamically stable patients who undergo CT scanning during their immediate resuscitation do not need a routine PXR. The PXR may continue to be beneficial in unstable patients, those with positive physical findings, or those who cannot undergo CT scanning because of other clinical priorities.

Abdominal Injuries↗

Predicting the histology of anterior mediastinal masses: comparison of chest radiography and CT.

The objective of this study was to compare chest radiography with computed tomography (CT) in the prediction of a specific diagnosis in adult patients with anterior mediastinal masses. Chest radiographs and CT scans of 128 patients with anterior mediastinal masses were randomized and analyzed retrospectively by two independent observers. The observers listed the three most likely diagnoses in order of probability and recorded the degree of confidence in their first-choice diagnosis. Findings from chest radiographs and CT scans were recorded by each observer and used for a stepwise discriminant analysis between diagnoses. Results showed that the correct first-choice diagnosis, regardless of the degree of confidence, was made in 36% of chest radiographs and 48% of CT scans (p < 0.05). The correct diagnosis was included among top three diagnoses in 59% and 72% of the studies, respectively (p < 0.001). A high confidence diagnosis (level 1) was reached in 9% and 34% of each study, respectively, (p < 0.001), and was correct in 58% and 80% of the studies, respectively. Interobserver agreement (k statistics) on the correct first-choice diagnosis was 0.45 and 0.53, respectively. Interpretations of the CT scans were most often accurate in the confident diagnosis of benign germ cell tumors (n = 10, 100%), thymolipomas (n = 3, 100%), and omental hernia (n = 2, 100%). Seven of 15 radiographic findings and 11 of 22 CT findings were discriminant. We conclude that although CT is better then chest radiography in determining the pathologic diagnosis of an anterior mediastinal mass, CT is still poor at making that prediction with confidence. However, several anterior mediastinal masses could be diagnosed accurately by CT.

Adolescent↗

The utility of routine chest radiography following jet ventilation in elective laryngotracheal surgery.

OBJECTIVES/HYPOTHESIS: Jet ventilation is a useful mode of airway management for laryngotracheal surgery. The objective of this study is to evaluate the utility of routine chest radiography following jet ventilation for these cases. STUDY DESIGN: Retrospective chart review. METHODS: Thirty-four elective surgical procedures performed from 1998 to 2002 are reviewed for postoperative airway and pulmonary complications. Data were collected from clinical notes as well as from the results of chest radiographs. This included the need for tracheotomy, reintubation, pneumothorax, pneumomediastinum, and atelectasis. RESULTS: A retrospective chart examination revealed no major complications. Twenty-nine of the 34 cases had postoperative chest radiography (CXR) performed on a routine basis. Atelectasis was present in 12 of 29 CXR (41%); no intervention was required in these cases. CONCLUSIONS: Routine postoperative CXR may not be useful following jet ventilation for elective laryngotracheal surgery. The safety of jet ventilation is discussed.

Adult↗

Lumbar instability: a dynamic approach by traction-compression radiography.

Translatory segmental instability was provoked by successive axial traction and compression of the lumbar spine in 117 patients with a known spondyl- or retro-olisthetic displacement. Lateral spot radiography showed an anteroposterior translatory movement of 5 mm or more in 24 of 45 patients with lytic spondylolisthesis of L5, in all of 7 patients with degenerative spondylolisthesis of L4, and in 37 of 65 patients with a retro-olisthetic displacement of L3, L4, or L5. In cases of spondyl- and retro-olisthetic instability the upper vertebra moved posteriorly during traction and anteriorly during compression. Severity of low-back pain (LBP) symptoms did not show any correlation with the degree of the maximal displacement but correlated significantly with the amount of instability both in the case of spondyl- and retro-olisthesis. Traction-compression radiography proved a simple and practical method to diagnose and measure translatory segmental instability even when conventional flexion-extension load failed to provoke any abnormal movement (eg, in the case of spondylolisthesis).

Adolescent↗

Compression-traction radiography of lumbar segmental instability.

Compression-traction radiography was used to assess movements in the sagittal plane of the lumbosacral joint in a control group of asymptomatic normal individuals and in a patient group with a symptomatic lytic spondylolisthesis. Sagittal translatory movements were found in both groups, but the amount of displacement was significantly larger (P less than 0.001) in the patient group as compared with the controls. The average displacement in the patient group, using a relative measurement technique, was 5.2%, ranging from 0.2 to 15.4%; and the corresponding values in the controls resulted in a mean of 0.8% and a range of -2.3% to 3.6%. Eighteen of the 29 patients (62%) exhibited translations of the lytic vertebra exceeding the largest displacement (greater than 3.6%) detected in the control group. The translatory movements in the patients were composed of a predominant anterior displacement in the compression view and a smaller posterior movement in the traction view. Analysis of sagittal rotation, ie, angulatory movements in the L5-S1 segment, resulted in no significant difference between the two groups. Compression-traction radiography may detect pathologic translatory movements, indicative of lumbar segmental instability.

Adult↗

False profile radiography for the evaluation of Legg-Calvé-Perthes disease.

False profile radiography (FPR), as proposed by Lequesne and de Sèze, depicts the pathology on the anterolateral acetabular wall and femoral head. A study was conducted to find out the differences between normal anteroposterior radiography and FPR. Twenty-seven patients with Legg-Calvé-Perthes disease who had not been operated on previously and 50 recruits without any pathology were studied for the acetabulum-head index of Heyman-Herndon (HHI) and center-edge angles (CEs) in antero-posterior radiographs and VCA angles in FPR. The VCA angle is most useful to detect anterolateral coverage of the femoral head in lateral pillar C hips. FPR is an easy, reliable and cheap technique to evaluate the anterolateral parts of the femoral head, and the acetabulum.

Acetabulum↗

The assessment of acetabular index: is there still a place for plain radiography?

This is a series of 7 children (14 hips) with a mean age of 7.3 years (range, 3.3-10.5 years) and an underlying diagnosis of developmental dysplasia of the hips and no previous open-hip surgery who underwent plain radiographic and magnetic resonance imaging (MRI) measures of bony acetabular index. There was a significant correlation between the measurement of acetabular index using plain radiography and MRI, with a Spearman correlation coefficient of 0.88 (95% confidence interval, 0.61-0.96; P<0.001) and a mean difference between the 2 measures of 0.36+/-6.5 degrees. Furthermore, the bony and cartilaginous acetabular indexes as measured by MRI had a significant correlation with a Spearman correlation coefficient of 0.88 (95% confidence interval, 0.80-0.98; P<0.001). We suggest that plain radiography is still an appropriate tool for follow-up for the nonoperated hip with developmental dysplasia and may be a good indicator of hip cartilaginous development.

Acetabulum↗

Contrast-detail phantom study for x-ray spectrum optimization regarding chest radiography using a cesium iodide-amorphous silicon flat-panel detector.

RATIONALE AND OBJECTIVES: The purpose of this study evaluating a cesium iodide-amorphous silicon-based flat-panel detector was to optimize the x-ray spectrum for chest radiography combining excellent contrast-detail visibility with reduced patient exposure. MATERIALS AND METHODS: A Lucite plate with 36 drilled holes of varying diameter and depth was used as contrast-detail phantom. For 3 scatter body thicknesses (7.5 cm, 12.5 cm, 21.5 cm Lucite) images were obtained at 113 kVp, 117 kVp, and 125 kVp with additional copper filter of 0.2 and 0.3 mm, respectively. For each setting, radiographs acquired with 125 kVp and no copper filter were taken as standard of reference. On soft-copy displays, 3 observers blinded to the exposure technique evaluated the detectability of each aperture in each image according to a 5-point scale. The number of points given to all 36 holes per image was added. The scores of images acquired with filtration were compared with the standard images by means of a multivariate analysis of variance. Radiation burden was approximated by referring to the entrance dose and calculated using Monte Carlo method. RESULTS: All 6 evaluated x-ray spectra resulted in a statistically equivalent contrast-detail performance when compared with the standard of reference. The combination 125 kVp with 0.3 mm copper was most favorable in terms of dose reduction (approximately 33%). CONCLUSION: Within the constraints of the presented contrast-detail phantom study simulating chest radiography, the CsI/a-Si system enables an addition of up to 0.3 mm copper filtration without the need for compensatory reduction of the tube voltage for providing constant image quality. Beam filtration reduces radiation burden by about 33%.

Cesium↗

Dual energy subtraction digital radiography: technical considerations, clinical applications, and imaging pitfalls.

Emerging applications in digital radiography offer exciting advances in the evaluation of lung disease. Dual energy subtraction techniques have been recognized as a promising technique in the detection and characterization of pulmonary nodules. This essay will demonstrate a significantly expanded diagnostic role in the assessment of cardiothoracic disease with dual energy subtraction and digital radiography.

Calcinosis↗

Comparison of thoracic ultrasound, clinical acumen, and radiography in patients with minor chest injury.

BACKGROUND: This study was designed to compare ultrasonography, clinical findings, and radiography in the detection of rib and sternal fractures. METHODS: In a prospective study, 88 patients presenting consecutively to an emergency department with isolated blunt chest injury of mild to moderate force were recruited. RESULTS: Ultrasonography yielded a sensitivity of 80.3 (95% confidence interval [CI], 69.5-88.5) for detecting chest wall fractures compared with sensitivities of 26.0 (95% CI, 15.8-36.3) for clinical acumen and 23.7 (95% CI, 14.7-34.8) for radiography. CONCLUSION: Early ultrasonography is more accurate than clinical and radiologic evaluation at detecting rib and sternal fractures.

Female↗

Measurement accuracy of proximal femoral geometry using biplanar radiography.

Experimental testing indicates that the neck-shaft angle of the proximal femur can be reliably measured from biplanar radiographs, but torsion cannot. Calculated torsion varies significantly from true torsion as a function of the error created by femoral rotation, while the calculated neck-shaft angle is invariant with respect to rotation even though the calculated neck-shaft angle is mathematically dependent on calculated torsion. Theoretical considerations support this finding and demonstrate for the first time why it is true. This study demonstrates that clinical measurements of frontal plane hip deformities using existing biplanar radiography are quite accurate, but clinical measurements of torsional abnormalities are unreliable. These errors can be minimized if investigators specify the angle of the lateral X-ray beam on the anteroposterior film using methods described in this paper and if patient position is radiographically verified. The magnitude and types of errors inherent in biplanar radiography should be considered in planning preoperative strategies and in postoperative assessments of hip geometry.

Femur↗