A clinical investigation of the fit of removable partial dental prosthesis clasp assemblies.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
BACKGROUND CONTEXT: Painful lumbar disc degeneration is one of the most common ailments treated by spine surgeons. Currently, early disc disease and herniation are often treated with microdiscectomy. Late disc degeneration is usually treated with arthrodesis. With the advent of new technology and techniques in lumbar disc arthroplasty, interest in preserving spinal motion at degenerated motion segments has increased. The goals of lumbar disc arthroplasty are to provide long-term pain relief at the degenerated disc level, to restore disc height to protect neural elements and to preserve motion to prevent posterior facet arthropathy and adjacent segment disease. PURPOSE: The purpose of this review is to examine the anatomy and biomechanics of the lumbar motion segment to determine the features that successful disc arthroplasty prosthesis must possess. In addition, the early clinical results of three prostheses currently being used in humans are reviewed. STUDY DESIGN/SETTING: Review of the literature. METHODS: A systematic review of Medline for articles related to lumbar disc arthroplasty was conducted up to and including journal articles published in August 2003. In addition, the abstracts from the annual meetings of the North American Spine Society and Scoliosis Research Society from 1998 to 2003 were searched. The literature was then reviewed and summarized. RESULTS/CONCLUSIONS: Short-term results of lumbar disc arthroplasty as measured by pain relief and disability are good in some studies. Implants are relatively safe in the short term, and with newer designs complications are usually related to the surgical approach rather than early implant failure. Recovery times appear to be shorter than arthrodesis. Despite the relatively good early clinical results of these devices, questions remain about the long-term efficacy in pain relief and maintenance of motion, the results of randomized comparative trials with fusion and the life span of the devices. In addition, late sequelae and revision options are unknown. Current indications for lumbar disc arthroplasty are in the setting of a Food and Drug Administration trial in young, nonosteoporotic patients with one or two level symptomatic disc degeneration without severe facet arthropathy, segmental instability or neural element compression requiring a posterior decompression.
A 31-year-old woman had an extruding ocular implant in her right orbit. After surgically removing the implant, we transferred an autogenous dermis-fat graft from the hip region to the freshly prepared socket. The graft was sutured to the conjunctiva, and a conformer was placed in the socket. Eight weeks postoperatively, the dermis-fat graft was covered with conjunctival epithelium and a prosthesis was fitted successfully. No evidence of infection has occurred. This technique of using composite dermis-fat grafts in enophthalmos avoids recurrent extrusions and corrects the cosmetic problems produced by migrating or extruding implants.
Explore the source record for details and available documents.
Accurate placement of tracheobronchial stents is essential, since little adjustment can be made once the stent is deployed. We describe the use of an inexpensive tool, a radio-opaque ruler, to aid in the proper positioning of tracheobronchial stents.
BACKGROUND: Valve replacement in small aortic root remains a surgical challenge. The objective of this study was to compare results of the 19-mm bioprosthesis with those of larger prostheses in the elderly. METHODS: The 443 patients, 70 years of age and older, who underwent aortic valve replacement with Carpentier-Edwards pericardial bioprostheses were reviewed. RESULTS: There were 93 patients with a mean age of 76+/-4 years with implantation of 19-mm prostheses and 350 patients with a mean age of 75+/-4 years with larger bioprostheses. Associated aortoplasty was performed in 10 patients (11%) with 19-mm bioprostheses and in 8 patients (2%) with larger bioprostheses (p = 0.001). There were 11 deaths (12%) within 30 days of surgery in patients with 19-mm prostheses and 22 deaths (6%) among those with larger prostheses (p = 0.1). The 7-year survival rate averaged 61%+/-7% in patients with 19-mm prostheses and 67%+/-4% in those with larger prostheses (p = 0.8). The 7-year freedom rates from all valve-related events averaged 96%+/-2% and 93%+/-2%, respectively (p = 0.6). CONCLUSIONS: Aortic valve replacement with the 19-mm Carpentier-Edwards pericardial bioprosthesis offers excellent midterm results in the elderly.
BACKGROUND: Patient-prosthesis mismatch is a frequent cause of high postoperative gradients in normally functioning prostheses. The objective of this study was to determine whether mismatch can be predicted at the time of operation. METHODS: Indices used to predict mismatch were valve size, indexed internal geometric area, and projected indexed effective orifice area (EOA) calculated at the time of operation, and results were compared with indexed EOA and mean gradients measured by Doppler echocardiography after operation in 396 patients. RESULTS: The sensitivity and specificity of these indices to detect mismatch, defined as a postoperative indexed EOA of 0.85 cm2/m2 or less, were respectively: 35% and 84% for valve size, 46% and 85% for indexed internal geometric area, and 73% and 80% for projected indexed EOA. Projected indexed EOA also correlated best with resting (r = 0.67) and exercise (r = 0.77) postoperative gradients. CONCLUSIONS: The projected indexed EOA calculated at the time of operation accurately predicts mismatch as well as resting and exercise postoperative gradients, whereas valve size and indexed internal geometric area cannot be used for this purpose.
BACKGROUND: The Cryolife O'Brien (CLOB) is a composite stentless bioprosthesis constructed from noncoronary leaflets of three porcine aortic valves. This study aimed to investigate early and midterm results after aortic valve replacement with CLOB xenograft. METHODS: Between 1993 and 2000, the CLOB was implanted in 125 patients (62 men; mean age 71.3+/-6.4 years). Mean prosthesis size was 23.6+/-2 mm. Mean follow-up time was 37.0+/-12.1 months. Patients underwent echocardiographic studies preoperatively, at discharge, at 6 and 12 months postoperatively, and yearly thereafter. RESULTS: Early (30-day) mortality rate was 2.4% (3 of 125 patients). Of the four late deaths, none was valve related. Actuarial 7-year survival was 93.6%+/-3%. Seven-year freedom from primary valve failure was 98.1%+/-1.8%. All patients showed an improvement of functional status (p < 0.001). ANOVA revealed a significant reduction over time in peak and mean systolic gradients (p < 0.001). Effective orifice area index increased (p < 0.001) and left ventricular mass index significantly reduced in all valve sizes (p < 0.001) during this time interval. CONCLUSIONS: Because the early and midterm results with CLOB xenograft have been satisfactory, we encourage its use as a valve substitute, particularly in patients with small aortic roots.
BACKGROUND: The hemodynamic performance of aortic replacement prostheses is of extreme importance. There is renewed interest in hemodynamics because of the influence of prosthesis-patient mismatch on left ventricular mass regression and the potential influence on survival. METHODS: The hemodynamic performance of the second-generation Carpentier-Edwards supraannular porcine and pericardial (Perimount) bioprostheses and the third-generation Medtronic Mosaic porcine bioprosthesis were compared for mean gradient and effective orifice area index. The effective orifice area index of at least 0.85 cm2/M2 was considered as lack of prosthesis-patient mismatch. The study group included included 53 patients with Carpentier-Edwards supraannular porcine, 48 with pericardial, and 98 with Medtronic Mosaic porcine bioprostheses. RESULTS: The mean gradients were not different between the prostheses by prosthesis size. The Medtronic Mosaic was not provided in size 19. The mean gradients for the prostheses, except in the very large sizes, were all double-digit values. The effective orifice area index was not different between the prostheses but there was a trend toward prosthesis-patient mismatch in smaller size prostheses. CONCLUSIONS: There was no apparent hemodynamic advantage between porcine and pericardial bioprostheses in the aortic position.
BACKGROUND: Presently no ideal prosthesis for mitral valve replacement exists. The quadrileaflet mitral valve (SJM-Quattro-MV; St. Jude Medical, Inc, St. Paul, MN) is a chordally supported stentless bioprosthesis. Due to its specific geometry it seems to be particularly suited for mitral valve replacement. METHODS: From March 1999 to October 2000, 12 patients (ages 71+/-2 years) received the SJM-Quattro-MV. Six patients suffered from valvular stenosis and 6 patients from incompetence. Preoperatively, all patients were in New York Heart Association functional class III, with left ventricular ejection fraction amounts of 54%+/-17%. RESULTS: Eleven patients received a medium size SJM-Quattro-MV and one patient received a large size SJM-Quattro-MV. Cross-clamp time was 99.8+/-4.9 minutes. Additional procedures were coronary artery bypass grafting (n = 3) and left atrial microwave ablation (n = 2). Postoperative mortality (n = 1) was procedure related. At follow-up of 11.6+/-5.4 months, all patients were well, the transvalvular pressure gradient was 5.0+/-1.4 mm Hg, and the effective orifice area 2.7+/-0.2 cm2. CONCLUSIONS: Our preliminary experiences with the SJM-Quattro-MV presented good clinical results and promoted an optimistic way of thinking about the further development of these valve prostheses.
The postoperative course of a patient with hypoplastic left heart syndrome after a first-stage Norwood operation is governed to a large extent by the balance between the systemic and pulmonary circulations. Here we describe a simple and convenient technique for establishing an optimally sized systemic-pulmonary shunt by the application of a hemostatic clip. The method has been used in 6 patients.
Explore the source record for details and available documents.
We have tested a new method to enlarge the aortic annulus using a double-patch technique after the Manouguian principle. Our study included 14 patients who had no operative mortality and no complications; long-term follow-up was 13 years. The method prevented mitral insufficiency and operative bleeding at the aortic root.
Explore the source record for details and available documents.
BACKGROUND: Mitral valve replacement with prosthetic valves in infants and children requires consideration of multiple variables. When we examined our late follow-up, the effect of the growth of the patient relative to the size of the prosthesis placed was the most important variable predicting late successful results. We reviewed our experience with mitral valve replacement using the Starr-Edwards ball valve in children aged 5 years or younger, focusing on the effect of valve prosthesis-patient mismatch on the long-term results in the growing patient. METHODS: From August 1974 to June 1986, 8 patients aged 5 years or younger underwent mitral valve replacements using the Starr-Edwards prosthesis size OM in 3 patients and 1M in 5 patients. Model 6320 was used in 1 patient and Model 6120 in the remaining 7 patients. RESULTS: Follow-up was 100% from 15 to 27 years (mean, 20 years). No valve-related complications of thromboembolism, anticoagulant-related hemorrhage, or prosthetic valve endocarditis were seen. All patients normally developed to adult size. The range of the valve area index of the 3 patients who received the smaller Starr-Edwards valve (size OM) was 0.97 to 1.24 cm2/m2. Although this size valve was adequate for patient growth to adolescence, in each case valve replacement with a larger valve was required. CONCLUSIONS: Our long-term review of Starr-Edwards ball valve mitral valve replacement in children aged 5 years or younger shows that the Starr-Edwards ball valve (Models 6320 [1 patient] and 6120 [7 patients]) showed excellent durability, no thromboembolism, and no anticoagulant-related complications. Size OM valves required replacement for hemodynamic reasons because of patient growth; larger size 1M valves remained hemodynamically satisfactory in spite of patient growth.
Explore the source record for details and available documents.
BACKGROUND: The sizes with which manufacturers label valves are nonuniform and haphazard. This has led to confusion and inappropriate comparisons of hemodynamics between valves with the same labeled size. Hemodynamic performance of valves is primarily determined by the internal diameter (ID) of their orifice. METHODS: The purpose of this study was to determine the ID and external diameter of aortic valves used at our institution and compare the measurements to manufacturers' labeled sizes. We also evaluated valve size (ID, manufacturers' labeled size) in 527 patients undergoing isolated aortic valve replacement between 1990 and 1996. RESULTS: We demonstrated that no two manufacturers' tissue or mechanical valves have the same ID or external diameter for a given labeled size. The labeled size of tissue valves was 1 to 4 mm larger than the measured ID. The labeled size of mechanical valves was 3 to 5 mm larger than the measured ID. The St. Jude HP mechanical valve has a greater ID than all other mechanical valves for each labeled size. Among 403 patients operated on for predominant aortic stenosis, those patients receiving the Toronto Stented Porcine Valve (n = 98) had a larger mean ID (22.3+/-1.9 mm) than 204 patients receiving stented tissue valves (ID = 20.9+/-1.9 mm) and the 101 patients receiving mechanical valves (ID = 19.3+/-1.9 mm, p < 0.0001). However, when the manufacturers' labeled size was used as a measure of the size, the results were greatly exaggerated in favor of the Toronto Stented Porcine Valve (ID = 26.3+/-1.9 mm) compared with stented tissue valves (ID = 23.1+/-2.1) or mechanical valves (ID = 23.6+/-1.9) (p < 0.0001). CONCLUSIONS: Manufacturers' labeling of valves is nonuniform and may lead to erroneous comparisons and conclusions of hemodynamic differences between valves. We therefore recommend a standardized nomenclature for the size of all valves based on the ID measurement.
Explore the source record for details and available documents.