Polyethylene insert dislocation in a screw-in acetabular cup. A case report.

An isolated case of prosthetic failure occurred in a total hip arthroplasty. This case involved dislocation of the polyethylene portion of a screw-in acetabular cup. The clinical and radiographic findings were subtle. The radiographic measurements that help to distinguish this complication are discussed. Successful treatment was provided with surgical replacement of the polyethylene insert.

Acetabulum↗

Dissociation of a metal-backed polyethylene acetabular component. A case report.

A case of early failure of a total hip arthroplasty presenting as a dislocation is discussed. After failed attempts at closed reduction, an open procedure revealed that the polyethylene insert of the acetabulum had separated from its metal backing. The increasing use of metal-backed acetabular components in total hip arthroplasty produces another mechanical interface that may fail: the metal-polyethylene interface. surgeons should consider this possibility in dislocations of total hip prostheses that cannot be reduced by closed means.

Acetabulum↗

Pelvic mass caused by polyethylene wear after uncemented total hip arthroplasty.

A 50-year-old man developed a pelvic mass following uncemented total hip arthroplasty. The mass communicated with the hip via an acetabular defect after loosening of the acetabular component. Operative and histologic findings revealed a foreign body reaction to polyethylene debris. Revision arthroplasty and excision of the pelvic mass were performed successfully through a single incision. A mass adjacent to a loose prosthesis may present as polyethylene failure following total hip arthroplasty. Revision arthroplasty and excision of the mass after an accurate diagnosis are recommended.

Granuloma, Foreign-Body↗

Fixation of ultrahigh-molecular-weight polyethylene liners to metal-backed acetabular cups.

Locking mechanisms and metal-liner interface surfaces of six modular acetabular systems were evaluated to determine their effect on micromotion and backside wear of the polyethylene liner. Rotational and axial motion between the metal shell and polyethylene liner was measured in the Duraloc (DePuy, Warsaw, IN), Harris-Galante (Zimmer, Warsaw, IN), Impact (Biomet, Warsaw, IN), Lip Loc (Biomet), Precision Osteoloc (Howmedica, Rutherford, NJ), and Reflection (Smith & Nephew Orthopaedics, Memphis, TN) designs at the start of each test, and at 1 million, 5 million, and 10 million cycles. At 10 million cycles, the Lip Loc and Reflection cups had significantly lower rim micromotion than the Duraloc and Harris-Galante cups (F < .0010). The Impact, Precision Osteoloc, and Reflection cups had significantly lower rim subsidence than the Harris-Galante cup (F < .0025). The Harris-Galante cup had significantly greater rotational micromotion than the Lip Loc cup (F < .0074), and had significantly greater interface slippage than the Impact and Reflection cups (F < .0070). The Lip Loc produced significantly lower dome micromotion than the Harris-Galante (F < .0300). The Lip Loc and Reflection cups had significantly less backside wear than the Duraloc and Harris-Galante cups (P < .0001), the Impact cup (P < .0243), and the Precision Osteoloc (P < .0027) cup.

Acetabulum↗

Polyethylene wear in cases using femoral stems of similar geometry, but different metals, porous layer, and modularity.

In this report, 83 total hip arthroplasties in 75 patients with femoral stems of similar geometry but different metals, porous surfaces, and femoral head-neck design were compared at a mean follow-up of 66 months (range, 40-104 months). One type of acetabular component and polyethylene were implanted in all hips. The femoral stem was monoblock in 25 hips, and in 58 it had a modular head-neck piece; 70 stems had chrome-cobalt heads, and 13 heads were titanium. Equally satisfactory clinical results were obtained with either type of femoral implant (i.e., modular and monoblock). The calculated average annual linear polyethylene wear was significantly higher for the titanium stems with a plasma-spray porous surface and chrome-cobalt head on a Morse taper than the chrome-cobalt, beaded, monoblock stems (0.22 mm/year vs 0.07 mm/year, P < .0001). The prevalence of periprosthetic osteolysis was higher for these modular stems ( 15.7% vs 0%), but this difference was not statistically significant (P = .09). Gross corrosion was present on the taper surfaces of an autopsy-retrieved femoral implant with a modular cobalt-chrome head on a titanium stem. Particles of chromium 3-orthophosphate were present at the taper rim and in the periarticular tissues.

Cementation↗

A striated pattern of wear in ultrahigh-molecular-weight polyethylene components of Miller-Galante total knee arthroplasty.

Wear of the polyethylene tibial components is a potential cause of failure in total knee arthroplasty. In addition to pitting, burnishing, and scratching, subtle striations on the bearing portion of the tibial surface have been observed in components retrieved relatively early after implantation. The striated pattern most typically occurred in areas centrally located within the articulating surface. The striations were anteroposterior directed and were identified as local cold flow at the surface. There was a strong correlation between the medial and lateral striated areas, suggesting that these patterns are related to cyclic rolling of the knee. The general characteristics and alignment of the striations could be attributed to the compressive and tractive forces occurring during femoral rollback. For the clinician, these results suggest that kinematics, as well as contact stress, should be considered when evaluating wear of polyethylene components.

Adult↗

Catastrophic failure of the acetabular component in a ceramic-polyethylene bearing total hip arthroplasty.

Recent research in total hip arthroplasty has focused on attempts to decrease wear at the femoral head-acetabulum articulation, to limit the production of debris that is believed to lead to osteolysis and prosthetic loosening. The use of ceramic-on-polyethylene bearing surfaces has been reported to produce lower wear rates and therefore may increase the life expectancy of the joint arthroplasty. Problems with this bearing have been reported to be due to ceramic femoral head fracture. Reported here are 2 cases of catastrophic failure of total hip arthroplasties, involving a ceramic femoral head, caused by failure of the polyethylene acetabular liner, with subsequent penetration of the femoral head through the acetabular shell.

Acetabulum↗

Failure of the all-polyethylene patellar component after total knee arthroplasty.

From 1991 to 1996, 953 cases of porous-coated anatomic modular knee prostheses with all-polyethylene patellar components were implanted. Among them, 4 cases had breakage of the patellar component at the peg-button interfaces. One had loosening of the patellar component by cutting out the patellar bony bed. Heavy body weight, weakness of the pegs of the all-polyethylene patellar component, and osteonecrosis of the patella were conceived as the causes of failure.

Aged↗

Cytokine response of human macrophage-like cells after contact with polyethylene and pure titanium particles.

The aim of this study was to establish a human macrophage cell culture system to examine the effect of polyethylene (PE) and titanium particles on cytokine release by macrophage-like cells (MLC) and to quantify this response with respect to the nature and concentration of particles. Human monocytic leukemia cells were differentiated under standard conditions with vitamin D3 and granulocyte macrophage-colony-stimulating factor. Cells were characterized by fluorescence-activated cell-sorter Scan of CD 14 expression analysis as well as a phagocytosis test exploiting fluorescence-labeled particles of bacteria] walls. To achieve a relevant contact between the floating PE particles (approximately 1 microm in size) and MLC, a rotation device was used (15 rotations/min) during incubation. The same was done with the titanium particles. Cell culture supernatants were then analyzed for interleukin (IL)-1beta, IL-8, and tumor necrosis factor (TNF)-alpha using the enzyme-linked immunosorbent assay technique in the absence or presence of particles. Rotation of incubated MLC alone did not influence the secretion of TNF-alpha, but it enhanced secretion of IL-1beta and IL-8 about 30-fold compared to background levels. Both PE and titanium particles significantly enhanced MLC cytokine release, the amount of which depended on the concentration of particles. Using 40 X 10(8) PE particles (0.7 x 10(8) titanium particles) and 10(6) MLC, the maximal release of IL-1beta was about 20-fold (7-fold titanium particles) higher than that of the rotating control sample. The stimulation of IL-8 release was 4-fold (3-fold titanium particles) and of TNF-alpha. 300-fold (170-fold titanium particles) compared to controls. MLC were viable (>90% cell survival) at concentrations less than 108 x 10(8) polyethylene particles per 10(6) MLC and 16 x 10(8) titanium particles per 10(6) MLC. Rotation per se as well as exposure to increasing concentrations of PE and titanium particles stimulates cytokine release (TNF-alpha, IL-1beta, IL-8) by macrophages in vitro. This in vitro model resembles the in vivo situation near arthroplasties, where implant particles make contact with inflammatory cells, such as macrophages. Cytokine release by macrophages may impair osteoblast function as well as stimulate bone resorption by osteoclasts and macrophages, thereby causing aseptic loosening of arthroplasties. Our in vitro model provides a reproducible human cell system that might shed light on the pathogenesis of particle disease and might serve as a reproducible in vitro test system for the biocompatibility of foreign materials.

Cell Culture Techniques↗

Late failure of the polyethylene liner fixation in an uncemented total hip arthroplasty.

We report on the failure of fixation of a polyethylene liner of a Harris/Galante first-generation cementless acetabular component (Zimmer, Warsaw, IN). The failure was diagnosed 9 years after implantation. The polyethylene liner was partly dissociated in its metal shell, resulting in nearly complete wearing through of the metal caused by the femoral head. This wearing contributed to severe metallosis and osteolysis around both the femoral and the acetabular component. The possible failure mechanisms are described, and a complete review of the literature is given.

Arthroplasty, Replacement, Hip↗

Relationship between wear debris particles and polyethylene surface damage in primary total knee arthroplasty.

To study relationships between design and wear, particles were isolated from tissues around 75 failed primary total knee prostheses, and particle size and concentration were compared with the extent and distribution of wear on superior and inferior polyethylene surfaces of the corresponding implants. Twenty-four heat-pressed, posterior cruciate ligament (PCL)-retaining (group I: PCA knee), 19 non-heat-pressed, PCL-retaining with relatively flat surfaces (group II: AMK, Kinematic, Microloc, Ortholoc), 14 non-heat-pressed, PCL-retaining with relatively congruent surfaces (group III: Townley Arizona), and 18 PCL-resected implants (group IV: Insall-Burstein, Total Condylar) were evaluated. Groups III and IV had fewer particles, smaller particles, and less surface damage than groups I and II. Implants with third-body wear had relatively small debris particles; those with thinner polyethylene had more severe surface delamination and more wear between liner and metal base. Groups I and II had more rotationally asymmetric wear patterns than groups III and IV. The size and concentration of debris particles might reflect, in part, different dominant wear mechanisms among implants of different designs.

Adult↗

Solid-state variable-temperature 1H MAS NMR studies on deuterated polyethylene.

Solid-state variable-temperature/magic angle spinning (VT/MAS) 1H NMR measurements were carried out on deuterated polyethylene. From these experimental results it was found that the 1H chemical shift induced by conformational and morphological changes of the polyethylene sample is within the linewidth of approximately 0.5 ppm. Furthermore, from MAS/dipolar decoupling experiments it was found that the resonance frequency of the proton varies linearly with the inverse square of the deuterium decoupling power. This experimental finding is discussed theoretically.

Deuterium↗

Polyethylene-lead tissue compensators for megavoltage radiotherapy.

Tissue compensators afford one the opportunity of producing idealized dose distributions in radiotherapy. We have developed a technique which may be used to produce fast, accurate and inexpensive compensators within a few minutes and requires minimal patient involvement. Three dimensional contour data is acquired using a moire fringe photograph taken at the time of simulation. The photograph is projected to the size needed for the actual compensator and a sketch of the compensator is made. The sketch is placed in a specially designed small portable pantographic unit and the design is traced while the unit cuts the compensator from an indexed polyethylene-lead blank which is premounted on an acrylic tray. The polyethylene-lead material proves to have an ideal combination of properties for compensator construction including relatively high density, ease of machining, good handling characteristics and low cost.

Humans↗

Clinical use of polyethylene glycols as marker substances and determination in urine by liquid chromatography.

Adulteration of samples is a serious problem in the analysis of drugs of abuse. One of the most frequent methods is substitution of urines by "clean" urines to gain false-negative results in laboratory tests for drugs of abuse. One way to approach this problem may be to label the patient's urine with marker substances which are given orally prior to the delivery of urine. This concept is based on methods for determining malabsorption in pediatric medicine. We report a protocol for evaluating low-molecular-mass polyethylene glycols as enteral labelling marker substances. For monitoring renal excretion of the ingested polyethylene glycols we have developed and optimised an isocratic reversed-phase high-performance liquid chromatographic method with automatic sample cleanup by column switching in the back-flush technique and with RI detection. The chromatographic procedure is simple, reliable and rapid, allowing a high sample throughput for routine screening.

Calibration↗

The adsorption of endotoxin molecule in a microporous polyethylene hollow fibre membrane.

The microporous polyethylene hollow fibre membrane is capable of adsorbing small-sized lipopolysaccharides (LPS) prepared by sonication dispersion, column chromatography on Sephadex G-75 and filtration through a filter membrane with a nominal pore size of 0.025 micron. Small-sized LPS had a one-thousandth of endotoxin activity as compared to intact LPS, when determined by the Synthetic Chromogenic Substrate method of LAL with a specific endotoxin activity of 73.7 ng/micrograms LPS. Fluorescent microscopy of fluorescein conjugated LPS on a microporous polyethylene hollow fibre showed that fluorescein-LPS was adsorbed through the entire depth of the membrane texture. Accordingly the adsorption capacity of the filter for small-sized LPS was determined as 1.65 mg LPS/3.68 m2 surface/116 mg fibre/module.

Adsorption↗

Polycationic diblock and random polyethylene glycol- or tris(hydroxymethyl)methyl-grafted (co)telomers for gene transfer: synthesis and evaluation of their in vitro transfection efficiency.

We report on the synthesis of a series of polycationic telomers, polycationic diblock and random polyethylene glycol (PEG)-grafted (co)telomers, and polycationic random tris(hydroxymethyl)methyl (THM) cotelomers, and on their in vitro gene transfer capability. These compounds were obtained by a telomerization process of various amino-, tetraethylene glycol-, or THM-acrylamide taxogens with thiols which might derive from PEG2000. For N/P ratios [N is the number of (co)telomer amine equivalents; P is the number of DNA phosphate equivalents] from 0.8 to 10, these (co)telomers condensed DNA, forming (co)teloplexes with mean sizes in the 85-330 nm range, even for an N/P ratio of 0.8 or 1.25. Some structure-transfection efficiency relationships were established. Among the new polycationic derivatives that were synthesized and investigated for their transfection efficiency, the (i)Bu-[NH](75) telomers and the diblock polyethylene glycol-conjugated PEG2000-[NH](n) telomers are very promising candidates for gene transfer purposes.

Humans↗

Characterization of oligodeoxyribonucleotide-polyethylene glycol conjugates by electrospray mass spectrometry.

Electrospray mass spectrometry (ESMS) was used to characterize a number of differently functionalized polyethylene glycol-oligodeoxyribonucleotide conjugates. Sample preparation was found to be crucial to obtaining quality data. The resolution and precision of ESMS allowed for the identification of individual conjugates differing in MW by a single ethylene glycol unit with an accuracy of < or = 1 (0.02% of the molecular weight). In addition, ESMS was shown to be valuable in identifying chromatographically unresolvable components of a derivatized polyethylene glycol-oligonucleotide conjugate mixture.

Amides↗