Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MICROWAVES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56Linked to original sources

Studies on the hematologic effects of long-term, low-dose microwave exposure.

Hematologic and morphologic investigations were carried out in order to discover changes during and after prolonged exposure to microwave radiation. A 12-cm wavelength CW microwave generator was used as a source of radiation and the mean power density was 5 mW/cm2. The rats were exposed to microwaves for a period of 90 d for 1 h/d. Before, during, and after the irradiation period, hematologic examinations were carried out. The histological examinations of various organs and tissues of irradiated rats were carried out after the experimental period. No significant difference in any of the observed biological parameters was detected in experimental animals in comparison with control. It was concluded that these results indicate that it is unlikely that prolonged microwave exposure to low-intensity (around 5 mW/cm2) will cause marked changes in the peripheral blood counts of the irradiated organism.

Animals↗

[Sterilization of catheters used for intermittent bladder emptying using a domestic microwave oven].

In contemporary urology it is increasingly frequent the indication of intermittent catheterization. Patients undergoing this type of therapy use several non-standardized methods to make catheterization as clean as possible. Microwave sterilization has been successfully used for certain materials and biological residues. For this reason and because it is a rather inexpensive system, we tried to demonstrate that sterilization of catheters used by our patients for intermittent catheterization using domestic microwave ovens at home is a convenient, inexpensive and clean alternative that should be taken into account. The catheters used were those employed in our hospitalized patients for a minimum of 4 days, which involves a high percentage of contamination. In 15 cases, the catheter was treated in a 800 W domestic microwave oven after having washed it with water so as to eliminate macroscopic organic residues, and in another 15 cases they were thoroughly washed before microwave treatment. In either case, the treatment was done for over 6 minutes at maximum power with the precautions described in the text. In all instances, the catheter's sterility was confirmed except for one case where contamination occurred during post-treatment handling.

Humans↗

Differences in acetylcholine but not choline in brain tissue fixed by freeze fixation or microwave heating.

Among the many rapidly metabolized compounds in the brain, acetylcholine is one of the most challenging to sample effectively due to its rapid synthesis, degradation and sequestration. To ascertain problems that invalidate sampling procedures two methods of tissue fixation, microwave heat inactivation and freeze fixation, were used for obtaining mice and rat brain samples, respectively. The data show that acetylcholine levels obtained by microwave fixation were much higher than those obtained by freeze fixation. Choline levels were not affected by the fixation method used. Microwave fixation results in more accurate assessment of acetylcholine levels than the freeze fixation method, even though the tissue fixation time was less than 1 s in both methods, because tissue integrity is maintained in the microwave fixation, but not during freeze fixation.

Acetylcholine↗

Surgical treatment of bone tumors in conjunction with microwave-induced hyperthermia and adjuvant immunotherapy. A preliminary report.

OBJECTIVE: To develop an alternative approach in conjunction with microwave-induced hyperthermia. PATIENTS AND METHODS: Thermotherapy with microwave intracorporeal irradiation was used to treat 73 patients with bone tumors. The series was composed of 58 patients with malignant tumors and 15 with benign tumors: most of tumors occurred about knee joints (53/73 = 72.6%). The surgical procedure included separating the tumor bearing segment from surrounding normal tissues with a safe margin, cooling the normal tissues including the neurovascular bundle and the intraarticular structures with a water circulation system, while heating the tumor with the antenna array of a microwave system and providing an adequate soft-tissue cover for the dead bone. Postoperatively, an immune therapy regimen was carried out regularly. The patients' immunologic functions were monitored by assay of the subpopulation of T cells, IL-2 and sIL-2 R (soluble IL-2 receptor). RESULTS: Follow-up varied from 3 to 38 months (mean 19 months). Excluding 3 patients with malignancy in the vertebrae treated for palliation, 70 were evaluated according to oncological and orthopedic criteria. Five patients had local recurrence and required amputation. The remaining 65 had excellent local control. In 6 of the 55 patients with malignancy of the extremities, lung metastasis occurred one to two years after surgery. The oncological results were similar to those obtained by other limb-saving procedures. Pathological fracture occurred at devitalized bone in 5 patients. In 72.5% of the patients (29 of 40 tumor-free cases followed more than one year), knee joints functioned well, being stable and painless with almost full range of motion. Single photon emission computered tomography (SPECT) for 16 patients revealed revascularization of the devitalized tumor bearing bone segment could accomplish in one year or more. The immune states were improved in various extends after thermotherapy plus immunotherapy in the majority of patients. CONCLUSION: These results show that the use of microwave hyperthermia and adjuvant immunotherapy in conjunction with the surgical treatment of bone tumors can be considered a definitive procedure, which is safe and well-tolerated. The oncological and orthopedic results are encouraging.

Adolescent↗

Thresholds of cat cochlear nucleus neurons to microwave pulses.

Action potentials of neurons in cat dorsal and posteroventral cochlear nuclei were recorded extracellularly with glass microelectrodes while the head of the cat was exposed to microwave pulses at 915 MHz using a diathermy applicator. Response thresholds to acoustic tones, acoustic clicks, and microwave pulses were determined for auditory units with characteristic frequencies (CFs) from 278 Hz to 39.2 kHz. Tests with pulsatile stimuli were performed for durations of 20-700 mus, principally 20, 70, and 200 mus. Brainstem midline specific absorption rate (SAR) threshold was as small as 11.1 mW/g per pulse, and specific absorption (SA) threshold was a small as 0.6 muJ/g per pulse. Microwave thresholds were generally lower for CF less than 9 kHz, as were most acoustic thresholds. However, microwave threshold was only weakly related to click threshold and CF-tone threshold of each unit.

Animals↗

Microwave digestion of "residual fuel oil" (NIST SRM 1634b) for the determination of trace elements by inductively coupled plasma-mass spectrometry.

A microwave procedure for the digestion of the NIST 1634b reference material "residual fuel oil" in closed pressurized vessels was developed in an attempt to facilitate routine analysis and obtain reproducible conditions or comparable results. The influence of sample size, reagent composition and volume, microwave power, and duration of heating on the digestion procedure was studied. Pressure and temperature inside the reaction vessels were monitored to determine the progression of the reaction and to develop optimal conditions. A nine-step heating program requiring 36.5 min with microwave power not exceeding 450 W in the pulsed mode was found suitable for the digestion of approximately 250 mg fuel oil with a mixture of nitric acid (5.0 mL) and hydrogen peroxide (2.0 mL). The reproducibility of microwave power was determined in terms of the relative standard deviations (n = 3) for temperature (2.7%) and pressure (4.9%) data. The vapor pressures obtained with 5.0 mL Milli-Q water (heated) in an 80-mL digestion vessel showed good agreement with literature data. The excess acid in the resulting digests was removed by evaporation and the concentrations of 24 elements (Ag, Al, As, Ba, Bi, Ca, Cd, Co, Cr, Cu, Fe, Hg, Mg, Mo, Ni, Pb, Sb, Sn, Sr, Ti, Tl, V, U, and Zn) were determined in the diluted digests by inductively coupled plasma mass spectrometry (ICP-MS). The experimental results were in good agreement with the certified and recommended concentrations for eight elements (Al, As, Co, Cr, Ni, Pb, V, Zn) in solutions obtained after one digestion step. An additional digestion step, consisting of intermediate cooling and venting stages, was required for the accurate determination of Fe. No agreement was reached for Ca and Ba even after two-step digestion. The proposed method of digestion provided precise results with relative standard deviations generally less than 5% for most of the elements determined.

Journal Article↗

The modification of specific absorption rates in interstitial microwave hyperthermia via tissue-equivalent material bolus.

Patterns of specific absorption rates generated by interstitial, microwave antenna arrays must be experimentally ascertained and quantified to facilitate their clinical incorporation. Phantom studies involved the use of four single-gap, coaxial antennas oriented in a 2 cm square array. These dipoles were driven in phase by a microwave generator at a frequency of 915 MHz. The inherent limitations in modifying the specific absorption rate patterns were addressed with the addition of bolus to the phantom. These additions of Guy's muscle tissue-equivalent material were made either proximal or distal to the phantom proper. Experiments conducted in the presence and absence of tissue-equivalent material bolus showed the ability to achieve broader bands of 50% power deposition in certain bolus conditions. These heating patterns were sufficiently reproducible and predictable to warrant clinical application of the bolus addition. A through-and-through method of catheter implantation allowed for bolus addition when deemed necessary. Treatments with veterinary and human patients using the bolus method to modify heating patterns yielded augmented patterns of power deposition. The effective length of the antennas that would radiate efficiently was essentially broadened via introduction of a microwave-interacting medium. As a result of the tissue equivalent material's ability to absorb microwave power, it was necessary to interpose minimally-interactive styrofoam spacers to limit heat transfer effects at the tissue-bolus interfaces.

Aged↗

A theoretical model for input impedance of interstitial microwave antennas with choke.

PURPOSE: Two important characteristics for interstitial microwave antennas used in clinical hyperthermia are: (1) a good impedance match to minimize reflected power; and (2) a good power deposition pattern which is independent of insertion depth. A major problem of the miniature coaxial dipole antennas used for interstitial hyperthermia is the fact that the impedance and power deposition patterns of these antennas change with insertion depth. One possible solution is the addition of a coaxial choke. A theoretical model for calculating the input impedance of interstitial microwave antennas having a coaxial choke is presented, which may serve as the first step in the design of such antennas. METHODS AND MATERIALS: A theoretical model for calculating the input impedance of coaxial microwave antennas with and without a choke is presented using insulated antenna theory. The theoretical model was used to calculate the input impedance of several prototype antennas having various choke and feedline dimensions, and comparison was made with experimentally measured impedance measurements in tissue-equivalent phantom. RESULTS: The choke section of the antenna is not ideal if conventional plastic insulation is used as the choke dielectric, because the desired radiating length of the antenna is significantly shorter than the quarter-wavelength in the choke dielectric. Impedance calculations based on the theoretical model correlate reasonably well with experimentally measured impedance. Based on these calculations, the effect of parameters such as choke layer thickness and choke dielectric constant are discussed for a 915 MHz antenna with choke. CONCLUSION: The theoretical model can serve as a design aid for optimizing choked microwave antenna designs, as well as predicting the impedance match of a given antenna design at a given insertion depth. The model allows the effect of some variables not accessible experimentally such as termination impedance to be studied, which may also be useful in the understanding of these antennas. Calculations are easily performed on a desktop computer.

Humans↗

Transurethral microwave thermotherapy effectiveness in small prostates.

OBJECTIVES: To dispel the misconceptions that patients with small prostates react differently than patients with larger prostates to cooled transurethral microwave thermotherapy. Cooled transurethral microwave thermotherapy has developed into a valid alternative to treat men with lower urinary tract symptoms due to benign prostatic hyperplasia. However, doubts still remain regarding the ability of this office-based technique to treat smaller prostates. METHODS: A database of 713 men from six previous studies using cooled transurethral microwave thermotherapy devices developed by Urologix were combined for this analysis. The data were analyzed to determine whether the baseline prostate size had a significant effect on American Urological Association Symptom Index, peak flow rate, quality-of-life score, or symptom problem index. Follow-up intervals in this analysis include 6, 12, 24, 36, 48, and 60 months after therapy. Visual analog scale ratings during treatment were also assessed. General linear models and repeated measures analyses were performed. RESULTS: Statistical analysis showed no effect of baseline prostate size on treatment outcomes for more than 5 years. Visual analog scale measurements were also not affected by the baseline prostate size. CONCLUSIONS: Transurethral microwave thermotherapy appears to be as efficacious in treating patients with small prostates as those with large prostates and should be offered as a treatment modality to patients with prostates of all sizes.

Adult↗

Interstitial temperature mapping during Prolieve transurethral microwave treatment: imaging reveals thermotherapy temperatures resulting in tissue necrosis and patent prostatic urethra.

OBJECTIVES: Temperature mapping of the prostate during transurethral microwave thermotherapy and imaging of the resultant zones of tissue necrosis have been previously performed using several commercial systems. This study was performed using the Prolieve Thermodilatation System, which simultaneously compresses the prostate with a 46F balloon circulating heated fluid and delivering microwave energy into the prostate. METHODS: Interstitial temperature mapping during Prolieve treatment was performed on 10 patients with benign prostatic hyperplasia using 24 temperature sensors arrayed throughout the prostate. Voiding cystourethrograms were performed on 3 additional patients treated without temperature mapping to document the patency of the prostatic urethra 1 hour after treatment. Gadolinium-enhanced magnetic resonance imaging studies were performed on all patients 1 week after treatment to determine the extent and pattern of tissue necrosis resulting from transurethral microwave thermotherapy. RESULTS: Interstitial temperature mapping found that the heating pattern generated by the Prolieve system created average peak temperatures of 51.8 degrees C an average of 7 mm away from the prostatic urethra. These temperatures were greater near the bladder neck and mid-gland than toward the prostatic apex. Subtherapeutic temperatures were seen adjacent to the urethra, consistent with the viable tissue seen on gadolinium-enhanced magnetic resonance imaging sequences. Magnetic resonance imaging also revealed necrotic zones that were consistent with sustained temperatures greater than 45 degrees C. Voiding cystourethrograms showed widely patent prostatic urethras 1 hour after treatment. CONCLUSIONS: Transurethral microwave thermotherapy with the Prolieve Thermodilatation System produced sustained therapeutic temperatures that resulted in tissue necrosis while maintaining viable tissue surrounding a temporarily dilated prostatic urethra.

Body Temperature↗

Determination of dichlorvos by on-line microwave-assisted extraction coupled to headspace solid-phase microextraction and gas chromatography-electron-capture detection.

The pretreatment technique of microwave-assisted extraction on-line headspace solid-phase microextraction (MAE-HS-SPME) was designed and studied for one-step in-situ sample preparation prior to the chromatographic analysis of a pesticide on vegetables. The pesticide on chopped vegetables was extracted into an aqueous solution with the aid of microwave irradiation and then directly onto the SPME fiber in headspace. After being collected on to the SPME fiber and desorbed in the GC injection port, the pesticide (dichlorvos) was analyzed with a GC-electron-capture detection system. The optimum conditions for obtaining extraction efficiency, such as the pH, the polarity modifier, and the salt added in sample solution, the microwave irradiation, as well as the desorption parameters were investigated. Experimental results indicated that the proposed MAE-HS-SPME technique attained the best extraction efficiency of 106% recovery under the optimized conditions, i.e. irradiation of extraction solution (10% aqueous ethylene glycol) at pH 5.0 with medium microwave power for 10 min. Desorption at 220 degrees C for 3 min offered the best detection result. The detection was linear at 5-75 microg/l with correlation coefficient of 0.9985. Detection limit was obtained at approximately 1.0 microg/l level based on S/N=3. The proposed method provided a very simple, fast, and solvent-less procedure to collect pesticides directly from vegetables for GC determination. Its application was illustrated by the analysis of trace dichlorvos in vegetables.

Chromatography, Gas↗

Microwave excitation of ultrasound in graphite-fiber reinforced composite plates.

In this paper is demonstrated the effect of microwave beam polarization on the thermal generation of acoustic waves in continuous fiber-reinforced composite laminates. It is found that beam polarization strongly influences the dielectric interaction that leads to thermal losses, bulk expansion, and acoustic wave generation. The oriented graphite fibers in the composite laminate effectively short the microwave fields and reduce the generation efficiency nearly to zero. Ultrasonic waves at several hundred kHz generated in the composite are detected by air-coupled acoustic transducers located on the opposite side of the plate specimen from the 9.41 GHz incident microwave beam. With some averaging signal-to-noise ratios of better than 26 dB are obtained. Applying a conventional model of electromagnetic wave scattering in anisotropic media to this experiment yields good agreement between calculations and measured data. Implications for microwave-acoustic testing of graphite-reinforced composites are also discussed.

Journal Article↗

A microreactor for microwave-assisted capillary (continuous flow) organic synthesis.

A capillary-based flow system has been developed for conducting microscale organic synthesis with the aid of microwave irradiation. The capillary internal diameter investigated ranged from 200 to 1200 mum, while the flow rate was varied between 2 and 40 muL/min, which corresponds to the sample being irradiated approximately 4 min. Other parameters investigated include reaction concentration and power setting of the microwave. Excellent conversion was observed in a variety of cross coupling and ring-closing metathesis (RCM) reactions employing metal catalysts and in nucleophilic aromatic substitution and Wittig reactions that do not employ metals. Reactions that have solids in them do not seem to pose a significant concern for the method, such as blocked channels. It was shown that capillaries coated internally with thin films of Pd metal show tremendous rate accelerations and that the thin films themselves are capable of catalyzing Suzuki-Miyaura reactions with no exogenous catalyst added. Importantly, it has been demonstrated that reagents in separate syringes can be coinjected into the capillary, mix, and react with none of the laminar flow problems that plague microreactor (lab on a chip) technology. This paves the way to use microwave-assisted, flow capillary synthesis as a powerful and efficient means to replace "one-at-a-time" microwave synthesis to provide libraries of compounds in a scale suitable for biological screening purposes.

Journal Article↗

Solution-phase microwave-assisted synthesis of unsubstituted and modified alpha-quinque- and sexithiophenes.

The facile synthesis of poorly soluble unsubstituted and modified alpha-quinque- and sexithiophenes under microwave irradiation in the liquid phase is described. The use of microwave irradiation allowed these compounds to be prepared in a few minutes and at high yields by means of the Suzuki cross-coupling reaction. Unsubstituted sexithiophene was obtained in 10 min via the one-pot borylation/Suzuki reaction, purified according to a very simple procedure, and isolated in 84% yield. The efficient synthesis of two new methylated quinque- and sexithiophenes displaying liquid crystalline properties is reported. A new microwave-assisted methodology for the conversion of aldehyde-terminated quinque- and sexithiophenes into the corresponding cyano derivatives is also described. The use of microwaves was extended to the Sonogashira coupling reaction and found to be very effective in the preparation of a quinquethiophene containing acetylenic spacers. The electronic and optical characterization of this compound is reported and discussed in relation to that of unsubstituted quinquethiophene.

Journal Article↗

Microwave-assisted aqueous synthesis: a rapid approach to prepare highly luminescent ZnSe(S) alloyed quantum dots.

In this paper, we present a new procedure for the rapid synthesis of luminescent ZnSe nanocrystals in aqueous phase by microwave irradiation with controllable temperature. The effects of microwave irradiation and experimental conditions on the synthesis of nanocrystals were investigated systematically. It was found that there were significant effects of pH value of reaction solutions, molar ratio of precursors, and heating time of microwave irradiation on the optical properties of the ZnSe nanocrystals. A series of nanocrystals with different size was prepared in 1 h, and the photoluminescence quantum yield reached up to 17% at the optimal reaction condition. The results of HRTEM and XRD showed that the as-prepared nanocrystals had high crystallinity. The characterizations of EDS spectra and elemental analysis showed that the sulfur content of nanocrystals increased with the growth of nanocrystals. We speculated that the structure of nanocrystals was an alloy ZnSe(S) shell on the surface of the ZnSe particles core. Furthermore, we found that the oxygen from air in the reaction vessel played an important role in the decomposition of the thiol group under microwave irradiation.

Journal Article↗

Modification of TiO2 for enhanced surface properties: finite Ostwald ripening by a microwave hydrothermal process.

The effect of microwave modification of colloidal TiO2 suspensions under extended periods of treatment is presented. The nanoparticulate TiO2 is compared and contrasted to similar convection hydrothermally treated TiO2 and a commercial titania product, namely Degussa P25. Microwave-treated samples were analyzed by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and Raman spectroscopy to determine their physicochemical characteristics. Comparative surface area analyses were performed by N2 adsorption and calculated from a Brunauer-Emmett-Teller (BET) isotherm. The complementary techniques of XRD and TEM showed good correlation between observed and calculated particle sizes (by application of the Scherrer equation), with the material being highly crystalline anatase TiO2, as identified by XRD and Raman. This investigation identified that extended periods of microwave hydrothermal treatment do not greatly enhance the crystallinity and primary grain size. Treatment of >180 min has a negative effect on crystallite growth; however, treatment up to this time had a significant effect on the material's surface area. The limiting regime of Ostwald ripening for hydrothermal treatment is discussed in relation to the mechanism of microwave treatment, that is, rapid heating to temperature and extremely rapid rates of crystallization. The effect of these property modifications are further discussed in relation to photocatalytic and photoelectrochemical applications of TiO2 nanoparticles.

Journal Article↗

Effect of filler content and size to properties of composite resins on microwave curing.

The effect of filler content and size to property of composite resin using high purity spherical silica particles on microwave curing was examined by mechanical means and electron microscope observation to develop microwave-curing composite resin inlay. Increasing filler content in three kinds of filler particles (0.45, 0.96 and 1.46 microm) resulted in increasing compressive strength, diametral tensile strength and knoop hardness and indicated the highest values at the operative mixing limit. The effect of particle size was that the mechanical property of the 0.96 microm filled resin was highest, followed by 1.46 microm and 0.45 microm on the same filler content. The 0.96 microm filled resin had about the same knoop hardness on both surfaces of the cured sample, which means that uniform polymerization occurred in the cured sample. With electron microscope observation, the bubbles of about 1.0 microm and the cracks between the fillers and the matrix were observed in each cured resin. This is caused by the excessive absorption of microwave energy in fillers and surface treatment materials of fillers. Therefore, improvement of the composition of filler and surface treatment material of filler are needed, which makes it harder to absorb the microwave energy.

Journal Article↗

Laparoscopic microwave coagulation therapy for hepatocellular carcinoma.

BACKGROUND AND STUDY AIMS: Several different effective forms of treatment are available, singly or in combination, for patients with hepatocellular carcinoma (HCC). These include surgical resection, transcatheter arterial embolization, percutaneous ethanol injection, and percutaneous microwave coagulation therapy. In this study, we carried out laparoscopic microwave coagulation therapy (LMCT), using laparoscopic microwave electrodes to treat HCC. PATIENTS AND METHODS: Under local anesthesia, 24 patients with HCCs located on or near the liver surface underwent LMCT under direct laparoscopic vision, with ultrasound guidance. LMCT was performed using microwave electrodes with tips ranging from 15-45 mm in length, and the effectiveness of the treatment was confirmed using contrast-enhanced computed tomography (CT) within two weeks of the LMCT procedure. RESULTS: The mean longest axis of the 26 HCC nodules in 24 patients was 20 mm, and that of the coagulated areas including the nodules was 40 mm, with additional therapy being required in two patients. Complete efficacy of the treatment was observed in 21 patients (87.5%), but local recurrences were seen in three of them one year after LMCT. The three-year survival rate was 92%, but the number of patients included in the study was small. Hemostasis was complete, but mild pneumothorax occurred in three patients. CONCLUSIONS: LMCT under local anesthesia is a minimally invasive and effective therapy when carried out on a single occasion to treat HCCs located near the liver surface, and it can be safely performed under direct visual guidance.

Aged↗