Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56Linked to original sources

Drug assays--the role of modern voltammetric techniques.

Modern voltammetric techniques, e.g. differential pulse polarography and voltammetry, anodic/cathodic stripping voltammetry and electrochemical detection for high performance liquid chromatography or flow injection analysis, are reviewed with respect to their basic theory, design and usage of available instrumentation and applications to drug assays in formulation and body fluid matrices.

Electrochemistry↗

Physiological stimulation increases nonoxidative glucose metabolism in the brain of the freely moving rat.

The effects of mild stress on nonoxidative glucose metabolism were studied in the brain of the freely moving rat. Extracellular lactate levels in the hippocampus and striatum were monitored at 2.5-min intervals with microdialysis coupled with an enzyme-based flow injection analysis system. Ten minutes of restraint stress led to a 235% increase in extracellular lactate levels in the striatum. A 5-min tail pinch caused an increase of 193% in the striatum and 170% in the hippocampus. Local application of tetrodotoxin in the striatum blocked the rise in lactate following tail pinch and inhibited the subsequent clearance of lactate from the extracellular fluid. Local application of the noncompetitive N-methyl-D-aspartate receptor antagonist MK-801 had no effect on the tail pinch-stimulated increase in lactate in the striatum. These results show that mild physiological stimulation can lead to a rapid increase in nonoxidative glucose metabolism in the brain.

Animals↗

ATP-sensitive potassium channels and local energy demands in the rat hippocampus: an in vivo study.

Microdialysis coupled with an enzyme-based flow injection analysis was used to monitor brain extracellular lactate and glucose in the freely moving rat. Glucose levels reflect the balance between supply from the blood and local utilisation, and lactate efflux indicates the degree of local nonoxidative glucose metabolism. Local application of tolbutamide, a blocker of the ATP-sensitive potassium channel, decreased extracellular glucose and lactate levels in the hippocampus but not in the striatum. The increase in glucose and lactate levels following mild behavioural stimulation was also reduced by tolbutamide in the hippocampus. Similar effects on both basal and stimulated lactate levels were obtained with local application of 10 mM glucose. These results indicate that ATP-sensitive potassium channels are active under physiological conditions in the hippocampus and that the effects of tolbutamide can be mimicked by physiological glucose levels.

Adenosine Triphosphate↗

A rapid test for heroin (3,6-diacetylmorphine) based on two chemiluminescence reactions.

A rapid method for screening drug seizure samples for 3,6-diacetylmorphine (heroin), which consists of a simple hydrolysis procedure and flow-injection analysis with two chemiluminescence reagents, is described. Before hydrolysis, 3,6-diacetylmorphine evokes an intense response with a tris(2,2'-bipyridyl)ruthenium(III) reagent (prepared by dissolving the perchlorate salt in acetonitrile), and a relatively weak chemiluminescence response with a second reagent: potassium permanganate in an aqueous acidic polyphosphate solution. However, the permanganate reagent is extremely sensitive toward the hydrolysis products of 3,6-diacetylmorphine (i.e., 6-monoacetylmorphine and morphine). Some compounds commonly found in drug laboratories may cause false positives with tris(2,2'-bipyridyl)ruthenium(III), but do not produce the markedly increased response with the permanganate reagent after the hydrolysis procedure. The combination of these two tests therefore provides an effective presumptive test for the presence of 3,6-diacetylmorphine, which we have verified with 14 samples obtained from a forensic science laboratory.

Journal Article↗

Melatonin and its precursors scavenge nitric oxide.

Nitric oxide (NO) scavenging activity of melatonin, N-acetyl-5-hydroxytryptamine, serotonin, 5-hydroxytryptophan and L-tryptophan was examined by the Griess reaction using flow injection analysis. 1-Hydroxy-2-oxo-3-(N-methyl-3-aminopropyl)-3-methyl-1-triazene (NOC-7) was used as NO generator. The Griess reagent stoichiometrically reacts with NO2-, which was converted by a cadmium-copper reduction column from the stable end products of NO oxidation. Except for tryptophan, all the compounds examined scavenged NO in a dose-dependent manner. Melatonin, which has a methoxy group in the 5-position and an acetyl side chain, exhibited the most potent scavenging activity among the compounds tested. Serotonin, N-acetyl-5-hydroxytryptamine, and 5-hydroxytryptophan, respectively, showed moderate scavenging activity compared to melatonin. Tryptophan, which has neither a methoxy nor a hydroxyl group in the 5-position, exhibited the least NO scavenging activity.

5-Hydroxytryptophan↗

Quantitative examination of a perfusion microscope for the study of osmotic response of cells.

The perfusion microscope was developed for the study of the osmotic response of cells. In this microscope, the cells are immobilized in a transparent chamber mounted on the stage and exposed to a variety of milieus by perfusing the chamber with solutions of different concentrations. The concentration of the supplied solution is controlled using two variable-speed syringe pumps, which supply an isotonic solution and a hypertonic solution. Before using this system to characterize the osmotic response of cells, the change in the concentration of NaCl solution flowing through the chamber is examined quantitatively using a laser interferometer and an image processing technique. The NaCl concentration is increased from an isotonic condition to a hypertonic condition abruptly or gradually at a given constant rate, and decreased from a hypertonic condition to an isotonic condition. It is confirmed that the concentration is nearly uniform in the cross direction at the middle of the chamber, and the change in the NaCl concentration is reproducible. The average rate of increase or decrease in the measured concentration agrees fairly well with the given rate when the concentration is changed gradually at a constant rate. The rate of the abrupt change is also determined to be the highest limit achieved by the present method. As the first application of using the perfusion microscope for biological studies, the volume change of cells after exposure to a hypertonic solution is measured. Then, the hydraulic conductivity of the cell membrane is determinedfrom the comparison of the volume change between the experiment and the theoretical estimation for the measured change in the NaCl concentration of the perfused solution.

Adenocarcinoma↗

Mass transport and shear stress in a microchannel bioreactor: numerical simulation and dynamic similarity.

Microchannel bioreactors have been used in many studies to manipulate and investigate the fluid microenvironment around cells. In this study, substrate concentrations and shear stresses at the base were computed from a three-dimensional numerical flow-model incorporating mass transport. Combined dimensionless parameters were developed from a simplified analysis. The numerical results of substrate concentration were well correlated by the combined parameters. The generalized results may find applications in design analysis of microchannel bioreactors. The mass transport and shear stress were related in a generalized result. Based on the generalized results and the condition of dynamic similarity, various means to isolate their respective effects on cells were considered.

Animals↗

Nanoporous aluminum oxide as a novel support material for enzyme biosensors.

To construct novel amperometric sensors for the detection of hydrogen peroxide and pyruvate, peroxidase and pyruvate oxidase were immobilized in self-supporting nanoporous alumina membranes those made by anodic oxidation. Pyruvate oxidase and other enzymes were enclosed in poly(carbamoylsulfonate) hydrogel and sucked into the nanoporous alumina structure before polymerization. The alumina membranes were investigated by scanning electron microscopy before and after the enzyme immobilization. In an amperometric flow detector cell, pyruvate and hydrogen peroxide were detected under flow injection analysis conditions in concentration ranges from 1 microM to 100 microM and 5 microM to 500 microM, respectively. The achieved operational stability showed that alumina membranes can be used to construct enzyme-modified electrodes.

Aluminum Oxide↗

Zinc and copper determination in microsamples of serum by flow injection and atomic absorption spectroscopy.

A new approach to the direct determination of copper and zinc in serum and plasma is described. The sample is injected into a continuously pumped stream of water which is fed into the nebuliser of an atomic absorption spectrophotometer. Analytical results are obtained as a series of sharp peaks on a chart recorder. Analytical variables have been investigated, and the proposed method gave results comparable to those obtained using a conventional method based on precipitation of serum proteins with trichloroacetic acid. The proposed method takes less time to perform and was found to give more precise results than the conventional method. In addition, the flow injection analysis method can be performed using microsamples (10-100 microliters) and is thus ideally suited for use on children.

Copper↗

The effect of room-temperature storage on the stability of compounds in DMSO.

The stability of approximately 7200 compounds stored as 20-mM DMSO solutions under ambient conditions was monitored for 1 year. Compound integrity was measured by flow injection analysis using positive and negative electrospray ionization mass spectrometry. Each sample was assessed at the beginning of the study, after 12 months of storage, and at a randomized time point between the initial and final time points of the study. The relationship between length of storage and the probability of observing the compound was described by a repeated-measures logistic regression model. The probability of observing the compound was 92% after 3 months of storage at room temperature, 83% after 6 months, and 52% after 1 year in DMSO. An acceptable limit for compound loss and corresponding maximum storage time for samples in DMSO can be determined based on these results.

Dimethyl Sulfoxide↗

Development of a novel cytochrome p450 bioaffinity detection system coupled online to gradient reversed-phase high-performance liquid chromatography.

A high-resolution screening platform, coupling online affinity detection for mammalian cytochrome P450s (Cyt P450s) to gradient reversed-phase high-performance liquid chromatography (HPLC), is described. To this end, the online Cyt P450 enzyme affinity detection (EAD) system was optimized for enzyme (beta-NF-induced rat liver microsomes), probe substrate (ethoxyresorufine), and organic modifier (methanol or acetonitrile). The optimized Cyt P450 EAD system has first been evaluated in a flow injection analysis (FIA) mode with 7 known ligands of Cyt P450 1A1/1A2 (alpha-naphthoflavone, beta-naphthoflavone, ellipticine, 9-hydroxy-ellipticine, fluvoxamine, caffein, and phenacetin). Subsequently, IC50 values were online in FIA-mode determined and compared with those obtained with standardmicrosomal assay conditions. The IC50 values obtained with the online Cyt P450 EAD system agreed well with the IC50 values obtained in the standard assays. For high affinity ligands of Cyt P450 1A1/1A2, detection limits of 1 to 3 pmol injected (n=3; signal to noise [S/N]=3) were obtained. The individual inhibitory properties of ligands in mixtures of the ligands were subsequently investigated using an optimized Cyt P450 EAD system online coupled to gradient HPLC. Using the integrated online gradient HPLC Cyt P450 EAD platform, detection limits of 10 to 25 pmol injected (n=1; S/N=3) were obtained for high-affinity ligands. It is concluded that this novel screening technology offers new perspectives for rapid and sensitive screening of individual compounds in mixtures exhibiting affinity for liver microsomal Cyt P450s.

Animals↗

Determination of aromatic and branched-chain amino acids in plasma by HPLC with electrogenerated Ru(bpy)3(3+) chemiluminescence detection.

An HPLC method is described for the electrochemiluminescence (ECL) detection of amino acids, following cycloaddition reaction of their amino groups with divinyl sulfone (DVS), using electrogenerated tris(bipyridine)ruthenium(III). The derivatization reaction conditions were examined, with the optimum conditions found to be 40 mM DVS (pH 8.0) at 50 degrees C for 15 min. Detection limits for the 15 amino acids examined varied greatly (0.04-8.0 pmol) using a standard solution by flow injection analysis (FIA). These optimized conditions were used for HPLC determination of the amino acids in human plasma. A linear relationship was obtained up to 100 pmol on a column for aromatic and branched-chain amino acids. Recoveries of Tyr, Met, Val, Leu, Ile, Phe and Trp when added to human plasma (1 micromol/10 ml plasma, n=5) were 101.5+/-1.1, 99.0+/-1.2, 98.0+/-1.4, 101.1+/-1.6, 95.1+/-1.6, 99.2+/-1.5 and 97.7+/-1.3 % (mean+/-S.D.) respectively. The concentrations of the amino acids in the plasma are in good agreement with other published data.

2,2'-Dipyridyl↗

Hydrostatic pressure/perfusion culture system designed and validated for engineering tissue.

Tissue engineering to replace or repair damaged tissues using three-dimensional cell constructs is a promising approach to promote tissue regeneration de novo. The production of cell constructs is a critical process for maintaining cell viability and phenotypes in vitro prior to surgical treatment. We have developed a novel hydrostatic pressure (HP)/perfusion culture system for three-dimensional cell constructs with application of mechanical stimuli with HP and continuous medium changes. In this study, we tested and validated the performance of this culture system. This systems' performance was stable at a constant HP up to 5 MPa and at a cyclic HP up to 0-5 MPa at 0.5-0.03 Hz. The performance of medium perfusion in the culture chamber showed laminar flow from an inlet into the chamber parallel to the inner walls. Air bubbles on all inner surfaces of the culture chamber caused unstable HP application because air can be compressed with greater ease than water, consequently impacting fluid compression. Air bubbles in a 3D agarose gel model disappeared due to HP over time and the spaces vacated by the air bubbles were replaced with water. Our validated HP/perfusion culture system allows for a well-regulated constant or cyclic HP application in culture medium and can be applied to other 3D tissue culture for engineering tissue.

Bioreactors↗

Airborne bacterial endospores detected by use of an impinger containing aqueous terbium chloride.

An experimental investigation is described of a terbium luminescence sensor for continuous collection and detection of bacterial endospores suspended in the atmosphere. A sensor is presented that continuously monitors and rapidly detects small concentrations of aerosolized bacterial endospores. The aerosol particles are collected by an impinger from which terbium dipicolinate photoluminescence is measured. A preliminary test of the sensor is described with Bacillus globigii endospores that were dispersed in an aerosol chamber. Another experiment is described showing that evaporation of water from the impinger limits operation time of the sensor to a few hours.

Air Microbiology↗

Stopped flow apparatus for time-resolved Fourier transform infrared difference spectroscopy of biological macromolecules in 1H2O.

Stopped flow spectroscopy is an established technique for acquiring kinetic data on dynamic processes in chemical and biochemical reactions, and Fourier transform infrared (FT-IR) techniques can provide particularly rich structural information on biological macromolecules. However, it is a considerable challenge to design an FT-IR stopped flow system with an optical path length low enough for work with aqueous (1H2O) solutions. The system presented here is designed for minimal sample volumes (approximately 5 microL) and allows simultaneous FT-IR rapid-scan and VIS measurements. The system employs a micro-structured diffusional mixer to achieve effective mixing on the millisecond time scale under moderate flow and pressure conditions, allowing measurements in a cell path length of less than 10 microns. This makes it possible to record spectra in 1H2O solutions over a wide spectral range. The system layout is also designed for a combination of kinetic and static measurements, in particular to obtain detailed information on the faster spectral changes occurring during the system dead time. A detailed characterization of the FT-IR stopped flow system is presented, including a demonstration of the alkaline conformational transition of cytochrome c as an example.

Biopolymers↗

Thermal desorption solid-phase microextraction inlet for differential mobility spectrometry.

A splitless thermal desorber unit that interfaces a differential mobility spectrometry (DMS) sensor has been devised. This device was characterized by the detection of benzene, toluene, and xylene (BTX) in water. The detection of BTX in water is important for environmental monitoring, and ion mobility measurements are traditionally difficult for hydrocarbons in water because water competes for charge and quenches the hydrocarbon signals. This paper reports the use of a DMS with a photoionization source that is directly coupled to a solid-phase microextraction (SPME) desorber. The separation and detection capabilities of the DMS were demonstrated using BTX components. Detection limits for benzene, toluene, and m-xylene were 75, 50, and 5 microg mL(-1), respectively.

Adsorption↗

Resonance-enhanced multiphoton ionization time-of-flight mass spectrometry for detection of nitrogen containing aliphatic and aromatic compounds: resonance-enhanced multiphoton ionization spectroscopic investigation and on-line analytical application.

Resonance-enhanced multiphoton ionization (REMPI) combined with time-of-flight mass spectrometry (TOFMS) is an analytical method capable of on-line monitoring of trace compounds in complex matrices. A necessary prerequisite for substance selective detection is spectroscopic investigation of the target molecules. Several organic nitrogen compounds comprising aliphatic and aromatic amines, nitrogen heterocyclic compounds, and aromatic nitriles are spectroscopically investigated with a tunable narrow bandwidth optical parametric oscillator (OPO) laser system providing a scannable wavelength range between 220 and 340 nm. These species are known as possible precursors in fuel-NO formation from combustion of solid fuels such as biomass and waste. A newly conceived double inlet system was used in this study, which allows rapid change between effusive and supersonic molecular beams. The resulting REMPI spectra of the compounds are discussed with respect to electronic transitions that could be utilized for a selective ionization of these compounds in complex mixtures such as combustion and process gases. The practicability of this approach is demonstrated by wavelength selected on-line REMPI-TOFMS detection of aniline and cyanonaphthalene in the burning chamber of a waste incineration plant. REMPI mass spectra recorded at different excitation wavelengths as well as variations in time show the utilization of species-selective REMPI-TOFMS detection for on-line monitoring of crucial substances in pollutant formation.

Air Pollutants↗

Investigation of the mixing efficiency of a chaotic micromixer using thermal lens spectrometry.

This work investigates the efficiency of a chaotic micromixer using thermal lens spectrometry. The outlet of the mixing device was connected to a thermal lens detection head integrating the probe beam optical fibers and the sample capillary. The chaotic micromixer consisted of a Y-shaped poly(dimethylsiloxane) (PDMS) microchip in which ribbed herringbone microstructures were etched on the floor of the main channel. Due to the solvent composition dependence of the thermal lens response, the photothermal method was shown to be highly sensitive to nonhomogeneous mixing compared to fluorescence detection. The apparatus was applied to the determination of Fe2+ with 1,10-phenanthroline using flow injection analysis; a limit of detection of 11 microg L(-1) of iron was obtained.

Journal Article↗