The influence of inserting a Fuji pressure sensitive film between the tibiofemoral joint of knee prosthesis on actual contact characteristics.

OBJECTIVE: To investigate the influence of inserting a Fuji pressure sensitive film between the tibiofemoral joint of knee prosthesis on actual contact characteristics. DESIGN: A finite element analysis was used to investigate the alteration of contact characteristics of the tibiofemoral joint due to inserting a pressure sensitive film between the contacting surfaces. BACKGROUND: The discrepancy between actual contact behaviors of tibiofemoral joint of knee prosthesis and the measurement using Fuji pressure sensitive film was not discussed extensively. The change of direct contact circumstance of the tibiofemoral joint due to inserting a pressure sensitive film was not well reported. METHOD: A two-dimensional finite element model of the tibiofemoral joint of knee prosthesis in the sagittal plane was constructed. Four different radii of the femoral component were used to investigate the conformity effect. Two-layers of plane strain element were used to model the pressure sensitive film. The influence of inserting a pressure sensitive film on the actual contact characteristics was analyzed by comparing the results of the change in contact radius. RESULTS: Inserting a pressure sensitive film between contacting surfaces would disturb the original contact behaviors, especially in the lowest conformity design. The maximum difference of contact radius between the model simulating actual contact circumstance and the model with inserting a pressure sensitive film between contacting surface was 77% in the lowest conformity condition at the smallest load. CONCLUSIONS: This study proposes a quantitative analysis of contact characteristics in the tibiofemoral joint of knee prosthesis between the models with and without inserting a pressure sensitive film into the contact surface. The measurement of contact area in artificial tibiofemoral joints by using Fuji pressure sensitive film is always overestimated its true contact area by 14-77%. RELEVANCE: This study revealed the measurement of contact characteristics of artificial tibiofemoral joints by using Fuji pressure sensitive film which depends on not only the applied load, but also the conformity and material properties of the contact surface. Therefore, the information of the conformity and material properties of the contact surface should be provided as well as the applied load wherever a measurement of contact characteristics using Fuji pressure sensitive film is analyzed and interpreted.

Biomechanical Phenomena↗

Finite-element modeling of the anthropoid mandible: the effects of altered boundary conditions.

Finite-element modeling provides a full-field method for describing the stress environment of the skull. The utility of finite-element models, however, remains uncertain given our ignorance of whether such models validly portray states of stress and strain. For example, the effects of boundary conditions that are chosen to represent the mechanical environment in vivo are largely unknown. We conducted an in vitro strain gauge experiment on a fresh, fully dentate adult mandible of Macaca fascicularis to model a simplified loading regime by finite-element analysis for purposes of model validation. Under various conditions of material and structural complexity, we constructed dentate and edentulous models to measure the effects of changing boundary conditions (force orientation and nodal constraints) on strain values predicted at the gauge location. Our results offer a prospective assessment of the difficulties encountered when attempting to validate finite-element models from in vivo strain data. Small errors in the direction of load application produce significant changes in predicted strains. An isotropic model, although convenient, shows poor agreement with experimental strains, while a heterogeneous orthotropic model predicts strains that are more congruent with these data. Most significantly, we find that an edentulous model performs better than a dentate one in recreating the experimental strains. While this result is undoubtedly tied to our failure to model the periodontal ligament, we interpret the finding to mean that in the absence of occlusal loads, teeth within alveoli do not contribute significantly to the structural stiffness of the mandible.

Animals↗

Nonlinear elastic material property estimation of lower extremity residual limb tissues.

The interface stresses between the residual limb and prosthetic socket have been studied to investigate prosthetic fit. Finite-element models of the residual limb-prosthetic socket interface facilitate investigation of the mechanical interface and may serve as a potential tool for future prosthetic socket design. However, the success of such residual limb models to date has been limited, in large part due to inadequate material formulations used to approximate the mechanical behavior of residual limb soft tissues. Nonlinear finite-element analysis was used to simulate force-displacement data obtained during in vivo rate-controlled (1, 5, and 10 mm/s) cyclic indentation of the residual limb soft tissues of seven individuals with transtibial amputation. The finite-element models facilitated determination of an appropriate set of nonlinear elastic material coefficients for bulk soft tissue at discrete clinically relevant test locations. Axisymmetric finite-element models of the residual limb bulk soft tissue in the vicinity of the test location, the socket wall and the indentor tip were developed incorporating contact analysis, large displacement, and large strain, and the James-Green-Simpson nonlinear elastic material formulation. Model dimensions were based on medical imaging studies of the residual limbs. The material coefficients were selected such that the normalized sum of square error (NSSE) between the experimental and finite-element model indentor tip reaction force was minimized. A total of 95% of the experimental data were simulated using the James-Green-Simpson material formulation with an NSSE less than 5%. The respective James-Green-Simpson material coefficients varied with subject, test location, and indentation rate. Therefore, these coefficients cannot be readily extrapolated to other sites or individuals, or to the same site and individual some time after testing.

Amputation Stumps↗

[Applications of computer image processing and graph processing technologies in digital modelling of 3-D shapes of teeth, jaw and prosthesis].

In this paper, the images of sliced sections or CT sections of the specimen of teeth, jaw and prosthesis were processed by a computer image analysing system, and the plane shape of the 3-D objects of interest on the sections was converted into digital images using a special software module for contour analysing. Then the images were adjusted in scale, modified in coordinates and smoothed in shape, and the data format was transferred for finite-element analysis by a specially designed software. In such ways a method for the digital modelling of the 3-D shape of teeth, jaw and prosthesis was successfully established.

Computer Simulation↗

Road loads acting on manual wheelchairs.

A barrier to performing more in-depth analyzes during the wheelchair design process is a lack of dynamic reaction force and moment data, and the instrumentation to collect this data. Instrumentation was developed to collect the dynamic force and moment data. New data collections methodologies and analysis techniques were implemented to facilitate computer-aided-engineering for wheelchair designs. Data were collected during standardized wheelchair fatigue tests, while driving over a simulated road course within a laboratory, and while driving in the community. Seventeen subjects participated in this study. Based upon the three test conditions, a pseudo-statistical distribution of the force and moment data at both a caster and rear wheel was developed. The key parameters describing the distribution and the extremums of the data (minima and maxima) were compared using analysis of variance. The results showed that the force and moment distributions and extreme values were similar for the both sets of human trials (i.e., simulated road course and field trials). However, the standardized testing (i.e., wheelchair fatigue testing) differed from both human trials. The force/moment data gathered during this study are suitable for inputs in finite element analysis and dynamic modeling. Our results suggest that the fatigue tests should be modified to change the magnitude and increase the frequency of the forces and moments imparted on the wheelchair. The data reported from this study can be used to improve wheelchair standards and to facilitate computer-aided-engineer in wheelchair design.

Acceleration↗

Adaptive finite-element approach for analysis of bone/prosthesis interaction.

The study uses the finite-element method to analyse the stress field in a perfectly bonded hip prosthesis arising from loading through body weight. Special attention is paid to the accuracy of the numerical analysis, and adaptive mesh refinement is introduced to reduce the discretisation error. The finite-element procedure developed is especially well suited to analyse the behaviour of a bonded interface as it is capable of calculating accurately the stress at the nodal positions while satisfying the natural discontinuity in the stress field at this location. An orthotropic material model is used for the representation of the behaviour of the bone, and an axisymmetric geometry with non-symmetrical loading is adopted for the analysis. The results demonstrate the usefulness of adaptive mesh refinement and the significance of adopting anisotropic material modelling in the context of tissue/prosthesis interaction.

Anisotropy↗

Finite element model of antibody penetration in a prevascular tumor nodule embedded in normal tissue.

We have developed a pharmacokinetic model for monoclonal antibodies (mAb) to aid in investigating protocols for targeting small primary tumors or sites of metastatic disease. The model describes the uptake of systemically-administered antibody by a prevascular spherical tumor nodule embedded in normal tissue. The model incorporates plasma kinetics, transcapillary transport, interstitial diffusion, binding reactions, and lymphatic clearance. Antigen internalization can easily be incorporated. Simulations obtained from a three-dimensional finite element analysis are used to assess errors in predictions from earlier models in which the influence of the normal tissue was collapsed into a boundary condition at the tumor surface. The model employing a Dirichlet boundary condition substantially overpredicted the mean total tumor mAb concentration at all times. Although the model with a concentration-dependent flux (composite) boundary condition underpredicted mAb concentration, the discrepancy with finite element results is only notable at early times. Sensitivity analyses were performed on mAb dose and on the coefficients for mAb diffusion in the tissue regions, since reported antibody diffusivity values have varied over 30-fold. The results of the study suggest that mAb diffusivity and mAb binding site density in tumors should have major influences on optimizing doses and scheduling of mAb administration in tumor targeting protocols.

Algorithms↗

How morphology predicts mechanical properties of trabecular structures depends on intra-specimen trabecular thickness variations.

Two observations underlie this work. First, that the architecture of trabecular bone can accurately predict the mechanical stiffness characteristics of bone specimens when considering the combination of volume fraction and fabric, which is a measure of architectural anisotropy. Second, that the same morphological measures could not accurately predict the mechanical properties of porous structures in general. We hypothesize that this discrepancy can be explained by the special nature of trabecular bone as a structure in remodeling equilibrium relative to the external loads. We tested this hypothesis using a generic model of trabecular bone. Five series of 153 different architectures were created with this model. Each architecture was subjected to morphological analysis, and four different fabric measures were calculated to evaluate their effectiveness in characterizing the architecture. Relationships were determined relating morphology to the elastic constants. The quality of these relationships was tested by correlating the predicted elastic constants with those determined from finite element analysis. We found that the four fabric measures used could estimate the mechanical properties almost equally well. So the suggestion that fabric measures based on trabecular bone volume better represent the architecture than mean intercept length could not be affirmed. We conclude that for structures with equally sized elliptical voids the mechanical properties can be predicted well only if trabecular thickness variations within each structure are limited. These structures closely resemble previously developed models of trabecular bone. Furthermore, they are stiff in the principal fabric direction, hence, according to Cowin (J. Biomech. Eng. (108) (1986) 83), they are in remodeling equilibrium. These structures are also stiff over a large range of loading orientations, hence, are relatively insensitive to deviations in direction of loading.

Bone and Bones↗

Modelling debonded stem-cement interface for hip implants: effect of residual stresses.

OBJECTIVE: To assess the effect of the residual stresses due to cement curing on the load transfer of cemented hip implants. DESIGN: The load transfer at the stem-cement interface of an idealized hip stem surrounded by cortical bone was investigated using a three-dimensional finite element analysis. A debonded stem-cement interface was considered to simulate a highly polished stem in contact with cement; Coulomb friction at the stem-cement interface was considered. BACKGROUND: Numerical analyses on the load transfer of cemented hip implants do not include residual stresses due to cement curing at the stem-cement interface. METHODS: The magnitude of the residual stresses was determined experimentally. In the finite element model, non-linear contact elements modelled the debonded stem-cement interface. In particular, the compressive radial residual stresses that are generated at the interface, due to the cement expansion during curing, were treated similar to a press-fit problem. RESULTS: The cement stress distributions were affected by the magnitude of the residual stresses. Failing to include residual stresses underestimated the cement stresses at the interface, mainly affecting the radial and hoop stresses. The load was transferred from the stem to the cement more uniformly along the interface once residual stresses were included. CONCLUSIONS: Because there is no chemical bond at the interface between the stem and cement, the interface resistance depends on friction thus radial residual compressive stresses developed by the cement curing play a direct role. RELEVANCE: Implant loosening of cemented hip implants is one of the major causes of late failure of the arthroplasty. The load is transferred from the stem to the bone primarily across the interfaces, consequently modelling accurately the interface is essential in predicting the load transfer.

Biomechanical Phenomena↗

Vibrational analysis of mandible trauma: experimental and numerical approaches.

The aim of this study was to evaluate the effectiveness of vibrational assessment of the mandible fracture patterns. Measurement of natural frequencies and associated vibrational mode shapes was performed to determine the relationship between the dynamic behavior of the human mandible and incidence of mandibular fractures using both in vitro modal testing and finite element analysis. Our results show that the natural frequencies of the human mandible in dry and wet conditions are 567 Hz and 501 Hz, respectively. The first vibrational mode of human mandible is a bending vibration with nodes located at the mandibular body where bone fracture is less likely to occur. By contrast, high vibration amplitudes were identified in the symphysis/parasymphysis and subcondyle regions where bone fractures tend occur. These findings indicate that the vibrational characteristics of the mandible are potential parameters for assessment of the mechanisms of injury.

Finite Element Analysis↗

The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study.

Assuming that high stress peaks in the bone can trigger bone resorption a screw-shaped bone implant should be given such a design that the peak stresses arising in the bone, as a result of a certain load, are minimized. Using idealized assumptions the aim of the study was to analyse the effect of variations of the size and the profile of the thread of an axially loaded, screw-shaped, bone implant upon the magnitude of the stress peaks in cortical bone. The investigation was performed by means of axisymmetric finite element analysis. It was found that the shape of the thread profile has a profound effect upon the magnitude of the stresses in the bone and that very small threads of a favourable profile can be quite effective.

Bone Screws↗

A transversally isotropic elasto-damage constitutive model for the periodontal ligament.

A numerical formulation of an elasto-damage constitutive model was developed and implemented in a finite element software to investigate the biomechanical response of the periodontal ligament (PDL). The mathematical framework accounts for the description of large strains, anisotropy and inelastic phenomena. The anisotropic mechanical response is caused by the spatial orientation of the sub-structures of the tissue, such as collagen fibres. Inelastic behaviour, induced by high level strains, is modelled by means of damage models. In vitro experimental testing on PDL samples from pigs was performed to obtain tensile stress-strain curves. A finite element analysis is presented in order to define a general numerical approach. A comparison of numerical and experimental data is provided in order to show the reliability and effectiveness of the formulation assumed.

Animals↗

[Studies on biomechanics of human foot: a review].

The plantar pressure and shear force measurement, the function and effect of joints, bones and ligaments of foot during running and walking, and the modeling and finite element analysis of human foot are three important aspects in biomechanical study of foot. They are also the basis of the study of rehabilitation. In this paper, studies on the three aspects are reviewed, and further promising developments are proposed.

Biomechanical Phenomena↗

Using the finite element method to model the biomechanics of the asymmetric mandible before, during and after skeletal correction by distraction osteogenesis.

An approach was developed to evaluate the load transfer mechanism in the temporomandibular joint (TMJ) area before, during and after mandibular ramus elongation by distraction osteogenesis (DO). In a concerted approach using computer tomography, magnetic resonance imaging (MRI), and finite element analysis, three-dimensional numerical models based on a young male patient, with a dento-facial deformity were generated. The magnitude and direction of the muscle forces acting on the mandible were assessed using both values derived from the muscles volume and cross-section as retrieved from the MRI-scan data-sets and taken from the literature. The resistance of the soft tissue envelope towards elongation during the DO-phase was also included. The finite element analyses showed that before skeletal correction by DO the load transfer was asymmetrical with high peak stresses in the affected joint. Following ramus elongation a more symmetrical loading in TMJs was predicted. The reaction forces in the TMJs during DO were low.

Arthritis, Juvenile↗

Biomechanical rationale for using polyetheretherketone (PEEK) spacers for lumbar interbody fusion-A finite element study.

STUDY DESIGN: To determine the effect of cage/spacer stiffness on the stresses in the bone graft and cage subsidence. OBJECTIVE: To investigate the effect of cage stiffness on the biomechanics of the fused segment in the lumbar region using finite element analysis. SUMMARY OF BACKGROUND DATA: There are a wide variety of cage/spacer designs available for lumbar interbody fusion surgery. These range from circular, tapered, rectangular with and without curvature, and were initially manufactured using titanium alloy. Recent advances in the medical implant industry have resulted in using medical grade polyetheretherketone (PEEK). The biomechanical advantages of using different cage material in terms of stability, subsidence, and stresses in bone graft are not fully understood. METHODS: A previously validated 3-dimensional, nonlinear finite element model of an intact L3-L5 segment was modified to simulate posterior interbody fusion spacers made of PEEK ("E" = 3.6 GPa) and titanium ("E" = 110 GPa) at the L4/5 disc with posterior instrumentation. Bone graft ("E" = 12 GPa) packed between the spacers in the intervertebral space was also simulated. The posterior lumbar interbody fusion spacer with instrumentation and graft represent a simulation of the condition present immediately after surgery. RESULTS: The peak centroidal Von Mises stresses in the graft bone increased by at least 9-fold with PEEK spacers as compared to titanium spacer. The peak centroidal Von Mises stresses in the endplates increased by at least 2.4-fold with titanium spacers over the PEEK spacers. These stresses were concentrated at places where the spacer interfaced with the endplate. The stiffness of the spacer did not affect the relative motion (stability) across the instrumented (L4/5) segment. CONCLUSIONS: Spacers less stiff than the graft will: (1) provide stability similar to titanium cages in the presence of posterior instrumentation, (2) reduce the stresses in endplates adjacent to the spacers, and (3) increase the load transfer through the graft, as evident from the increase in stresses in graft.

Benzophenones↗

Evaluation of patello-femoral alignment using MRI.

In evaluating patello-femoral alignment, it is not enough to assess the conformity of the joint two-dimensionally, the direction of the extensor mechanism must be examined three-dimensionally. Using magnetic resonance imaging (MRI), we adopted an ideal extensor mechanism plane intersecting the patellar facet of the femur centrally and perpendicularly. We evaluated the alignment according to the extent to which the patella and/or the tibial tuberosity deviated from the plane. The results suggested that our method is useful for indicating proximal and distal realignment. Furthermore, two-dimensional finite element analysis in the patello-femoral joint showed that peak stress was significantly higher in the dislocation group than in the no-dislocation group. This indicates that osteoarthritic change in the future is a risk in the dislocation group.

Adolescent↗

An inverse finite-element model of heel-pad indentation.

A numerical-experimental approach has been developed to characterize heel-pad deformation at the material level. Left and right heels of 20 diabetic subjects and 20 nondiabetic subjects matched for age, gender and body mass index were indented using force-controlled ultrasound. Initial tissue thickness and deformation were measured using M-mode ultrasound; indentation forces were recorded simultaneously. An inverse finite-element analysis of the indentation protocol using axisymmetric models adjusted to reflect individual heel thickness was used to extract nonlinear material properties describing the hyperelastic behavior of each heel. Student's t-tests revealed that heel pads of diabetic subjects were not significantly different in initial thickness nor were they stiffer than those from nondiabetic subjects. Another heel-pad model with anatomically realistic surface representations of the calcaneus and soft tissue was developed to estimate peak pressure prediction errors when average rather than individualized material properties were used. Root-mean-square errors of up to 7% were calculated, indicating the importance of subject-specific modeling of the nonlinear elastic behavior of the heel pad. Indentation systems combined with the presented numerical approach can provide this information for further analysis of patient-specific foot pathologies and therapeutic footwear designs.

Computer Simulation↗

Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty.

STUDY DESIGN: The biomechanical behavior of a single lumbar vertebral body after various surgical treatments with acrylic vertebroplasty was parametrically studied using finite-element analysis. OBJECTIVES: To provide a theoretical framework for understanding and optimizing the biomechanics of vertebroplasty. Specifically, to investigate the effects of volume and distribution of bone cement on stiffness recovery of the vertebral body. SUMMARY OF BACKGROUND DATA: Vertebroplasty is a treatment that stabilizes a fractured vertebra by addition of bone cement. However, there is currently no information available on the optimal volume and distribution of the filler material in terms of stiffness recovery of the damaged vertebral body. METHODS: An experimentally calibrated, anatomically accurate finite-element model of an elderly L1 vertebral body was developed. Damage was simulated in each element based on empirical measurements in response to a uniform compressive load. After virtual vertebroplasty (bone cement filling range of 1-7 cm3) on the damaged model, the resulting compressive stiffness of the vertebral body was computed for various spatial distributions of the filling material and different loading conditions. RESULTS: Vertebral stiffness recovery after vertebroplasty was strongly influenced by the volume fraction of the implanted cement. Only a small amount of bone cement (14% fill or 3.5 cm3) was necessary to restore stiffness of the damaged vertebral body to the predamaged value. Use of a 30% fill increased stiffness by more than 50% compared with the predamaged value. Whereas the unipedicular distributions exhibited a comparative stiffness to the bipedicular or posterolateral cases, it showed a medial-lateral bending motion ("toggle") toward the untreated side when a uniform compressive pressure load was applied. CONCLUSION: Only a small amount of bone cement ( approximately 15% volume fraction) is needed to restore stiffness to predamage levels, and greater filling can result in substantial increase in stiffness well beyond the intact level. Such overfilling also renders the system more sensitive to the placement of the cement because asymmetric distributions with large fills can promote single-sided load transfer and thus toggle. These results suggest that large fill volumes may not be the most biomechanically optimal configuration, and an improvement might be achieved by use of lower cement volume with symmetric placement.

Bone Cements↗