Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “FEMORAL FRACTURES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56Linked to original sources

[Locking compression plate fixation for periprosthetic femoral fracture].

OBJECTIVE: To introduce a method for fixation in periprosthetic fracture with locking compression plate (LCP). METHODS: During the surgery, a long 12-hole LCP was placed to the lateral side of the femur. Six holes of the plate were placed proximal to the main fracture line to make sure that there could be enough cortex units for rigid fixation of proximal fragments. Locking screws used except for the most proximal hole where a 4.5 mm screw was used instead. RESULTS: The patient was pain free at the fracture site one week after the surgery, and was able to walk with a cane 3 months after the surgery. Bone union was evident radiographically 3 months after the surgery. There was no loose signs around the stem. Six months after the surgery, the patient recovered full function without pain. CONCLUSION: In our experience from this case, LCP in treating periprosthetic fracture was easy and less time consuming, more over, extensive periosteal stripping could be avoided. LCP is a good choice in treating some periprosthetic fractures.

Aged↗