Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Accuracy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56Linked to original sources

Improving diagnostic accuracy: a comparison of interactive and Delphi consultations.

Consultation among physicians on difficult diagnostic problems is commonly used to improve the accuracy of medical decisions. Such consultation is most often informal and interactive. Nevertheless, behavioral studies suggest that non-interactive techniques may be more effective problem solving methods. Of these the Delphi approach, involving pooling and feedback of anonymously contributed information, has generated particular interest. To assess the relative effectiveness of independent decision making, interactive group consultation, and Delphi techniques in a clinical setting we compared the diagnostic accuracy of 17 radiologists interpreting radiologic examinations in these settings. Interactive consultation improved performance by 69% compared to radiologists interpreting the studies individually. In addition, two Delphi strategies each produced an additional 20% mean improvement in accuracy over interactive consultation. Whereas interactive consultation improved the accuracy of the best individual readers by only 6%, a Delphi model improved their performance by 25%. Thus, Delphi was an effective, easily applied method of clinical consultation whose usefulness in other clinical setting should be evaluated.

Decision Making↗

Accuracy of volume measurements of computed tomography and magnetic resonance imaging phantoms by three-dimensional reconstruction and preliminary clinical application.

RATIONALE AND OBJECTIVES: Using an independent three-dimensional workstation, the accuracy of volume measurements of phantoms was assessed using three-dimensional reconstruction of two-dimensional computed tomography (CT) and magnetic resonance (MR) images. METHODS: Round, cylindrical, and irregularly shaped high-contrast phantoms of known volume were imaged in a water bath. The effect of object contrast on volume estimation was tested using phantoms of known volume diluted serially with a contrast agent. The effect of changing field of view and slice thickness was assessed. A clinical application was performed, in which nine shoulders were injected with a known quantity of contrast material, to test the accuracy of the technique in vivo. RESULTS: A strong paired correlation (r = .99) between estimated and true volumes was obtained for high-contrast phantoms ranging from 17 to 128 mL. The weighted average absolute error was 1.42 mL (MR) and 3.50 mL (CT). Accuracy of the serially diluted 27-mL phantoms was essentially unaffected by contrast differences greater than 133 units (MR) and 102 units (CT). The weighted average absolute error was 1.33 mL (MR) and 1.56 mL (CT). Changing field of view had no effect on accuracy, but increasing the slice thickness resulted in over-estimation of volume. The mean error for the clinical application was 4.4% (range: 1.7%-8.3%). CONCLUSION: Under certain circumstances, three-dimensional reconstructive volume estimation can be a convenient and accurate method for volume determination.

Humans↗

Normal and high accuracy computed tomography of the brain: dose and imaging considerations.

The high accuracy scanning mode of the EMI CT1010 scanner generates scans with imaging characteristics superior to those produced in the normal accuracy mode. The comparative dosimetry of normal and high accuracy scans is presented, along with an analysis of the image quality of the two scanning modes. High accuracy scanning is an effective adjunct in patients with difficult lesions in the cerebral hemispheres.

Brain↗

Effect of geometrical distortion correction in MR on image registration accuracy.

In this article we investigate the effect of geometrical distortion correction in MR images on the accuracy of the registration of X-ray CT and MR head images for both a fiducial marker (extrinsic point) method and a surface-matching technique. We use CT and T2-weighted MR image volumes acquired from seven patients who underwent craniotomies in a stereotactic neurosurgical clinical trial. Each patient had four external markers attached to transcutaneous posts screwed into the outer table of the skull. The MR images are corrected for static field inhomogeneity by using an image rectification technique and corrected for scale distortion (gradient magnitude uncertainty) by using an attached stereotactic frame as an object of known shape and size. We define target registration error (TRE) as the distance between corresponding marker positions after registration and transformation. The accuracy of the fiducial marker method is determined by using each combination of three markers to estimate the transformation and the remaining marker to calculate registration error. Surface-based registration is accomplished by fitting MR contours corresponding to the CSF-dura interface to CT contours derived from the inner surface of the skull. The mean point-based TRE using three noncollinear fiducials improved 34%-from 1.15 to 0.76 mm-after correcting for both static field inhomogeneity and scale distortion. The mean surface-based TRE improved 46%-from 2.20 to 1.19 mm. Correction of geometrical distortion in MR images can significantly improve the accuracy of point-based and surface-based registration of CT and MR head images. Distortion correction can be important in clinical situations such as stereotactic and functional neurosurgery where 1 to 2 mm accuracy is required.

Head↗

The accuracy of CT staging of small bowel adenocarcinoma: CT/pathologic correlation.

PURPOSE: Several studies have documented the use of CT in the evaluation of small bowel neoplasms, but few have addressed the CT staging of adenocarcinoma. We retrospectively correlated CT and pathologic staging to evaluate the accuracy of CT for staging small bowel adenocarcinoma using American Joint Committee on Cancer criteria. METHOD: The preoperative CT scans of 15 patients with pathologically proven small bowel adenocarcinoma were analyzed. Two blinded readers separately interpreted extent of invasion, presence of lymphadenopathy, and distant metastases. Pathologic and CT staging were compared. RESULTS: The overall accuracy of CT staging was 47% (14/30). The sensitivity of detection of mesenteric infiltration was 88%. The sensitivity and specificity for detection of distant metastases were 58 and 63% and for lymphadenopathy 75 and 20%, respectively. Errors occurred in patients with Crohn disease, adenomas, Peutz-Jegher syndrome, small bowel obstruction, and perforation and on suboptimal studies. CONCLUSION: The accuracy of CT staging of small bowel adenocarcinoma is 47%. CT is highly sensitive but not specific for the detection of mesenteric infiltration and regional lymphadenopathy. Since spiral CT may offer improved detection of distant metastases and increased accuracy in the evaluation of patients with concomitant bowel disease, further research is needed to determine the maximal utility of CT in the staging of adenocarcinoma of the small bowel.

Adenocarcinoma↗

Diagnostic accuracy of multidetector row computed tomography in T- and N staging of gastric cancer with histopathologic correlation.

PURPOSE: To evaluate the diagnostic accuracy of multidetector row computed tomography (MDCT) for the preoperative T- and N staging of gastric cancer. MATERIALS AND METHODS: Eighty-four consecutive patients with gastric cancer underwent preoperative MDCT. Except for 15 patients who did not undergo surgery, 69 patients were included in our study. Two radiologists independently evaluated the T- and N staging on the axial CT images alone and in combination with the MPR images. For N staging, the new TNM and Japanese classifications were independently used. Differences in staging accuracy for T- and N staging were assessed using the McNemar test. RESULTS: The overall T staging accuracy of the axial and combined axial and MPR images was as follows: 67% (47 of 70 cancers) versus 77% (54 of 70 cancers) (P=0.039). The overall N staging accuracy of the axial and combined axial and MPR images was as follows: 59% (41 of 69 cancers) versus 67% (46 of 69 cancers) (P=0.180, Japanese classification) and 54% (37 of 69 cancers) versus 59% (41 of 69 cancers) (P=0.109, TNM classification). CONCLUSIONS: Using MPR images enables more accurate preoperative T staging of gastric cancer, but not for N staging in either classification system.

Adult↗

Accuracy of five electronic pedometers for measuring distance walked.

This is a three-part study that examined the accuracy of five brands of electronic pedometers (Freestyle Pacer, Eddie Bauer, L.L. Bean, Yamax, and Accusplit) under a variety of different conditions. In Part I, 20 subjects walked a 4.88-km sidewalk course while wearing two devices of the same brand (on the left and right side of the body) for each of five different trials. There were significant differences among pedometers (P < 0.05), with the Yamax, Pacer, and Accusplit approximating the actual distance more closely than the other models. The Yamax pedometers showed close agreement, but the left and right Pacer pedometers differed significantly (P = 0.0003) and the Accusplit displayed a similar trend (P = 0.0657). In Part II, the effects of walking surface on pedometer accuracy were examined. Ten of the original subjects completed an additional five trials around a 400-m rubberized outdoor track. The devices showed similar values for sidewalk and track surfaces. In Part III, the effects of walking speed on pedometer accuracy were examined. Ten different subjects walked on a treadmill at various speeds (54, 67, 80, 94, and 107 m.min-1). Pedometers that displayed both distance and number of steps were examined. The Yamax was more accurate than the Pacer and Eddie Bauer at slow-to-moderate speeds (P < 0.05), though no significant differences were seen at the fastest speed. While there are variations among brands in terms of accuracy, electronic pedometers may prove useful in recording walking activities in free-living populations.

Adolescent↗

Technical accuracy of a neuronavigation system measured with a high-precision mechanical micromanipulator.

OBJECTIVE: This study was designed to determine and evaluate the different system-inherent sources of erroneous target localization of a light-emitting diode (LED)-based neuronavigation system (StealthStation, Stealth Technologies, Boulder, CO). METHODS: The localization accuracy was estimated by applying a high-precision mechanical micromanipulator to move and exactly locate (+/- 0.1 micron) the pointer at multiple positions in the physical three-dimensional space. The localization error was evaluated by calculating the spatial distance between the (known) LED positions and the LED coordinates measured by the neuronavigator. The results are based on a study of approximately 280,000 independent coordinate measurements. RESULTS: The maximum localization error detected was 0.55 +/- 0.29 mm, with the z direction (distance to the camera array) being the most erroneous coordinate. Minimum localization error was found at a distance of 1400 mm from the central camera (optimal measurement position). Additional error due to 1) mechanical vibrations of the camera tripod (+/- 0.15 mm) and the reference frame (+/- 0.08 mm) and 2) extrapolation of the pointer tip position from the LED coordinates of at least +/- 0.12 mm were detected, leading to a total technical error of 0.55 +/- 0.64 mm. CONCLUSIONS: Based on this technical accuracy analysis, a set of handling recommendations is proposed, leading to an improved localization accuracy. The localization error could be reduced by 0.3 +/- 0.15 mm by correct camera positioning (1400 mm distance) plus 0.15 mm by vibration-eliminating fixation of the camera. Correct handling of the probe during the operation may improve the accuracy by up to 0.1 mm.

Evaluation Studies as Topic↗

Accuracy of a miniature intracranial pressure monitor, its function during magnetic resonance scanning, and assessment of image artifact generation.

OBJECTIVE: We examined the accuracy and repeatability of an intracranial pressure (ICP) monitor (Codman MicroSensor; Johnson & Johnson Professional, Inc., Raynham, MA) in a nonmagnetic environment and during magnetic resonance imaging (MRI). The resulting image artifact generation was calculated. ICP monitoring is essential in management of severe head injury, but few ICP monitoring devices are compatible with use in an MRI scanner. The use of MRI to assess head injury is increasing, and developing safe methods of continuously monitoring ICP may improve patient care. METHODS: A water manometer was used as the standard for comparison. We assessed pressure readings from the ICP monitor in a nonmagnetic environment using a standard and a long connector cable between the pressure transducer and display unit. This long cable permitted testing during MRI sequences because the display unit could be distanced from the magnet. Accuracy was determined during T2-weighted imaging, proton spectroscopy, and diffusion-weighted imaging, and artifact generation was assessed. RESULTS: We found a high degree of accuracy for repeated measurements over a clinical pressure range using both standard and long connector cables outside the MRI room. During MRI scanning, the ICP monitor was accurate during T2 and proton spectroscopy sequences. Accuracy during diffusion-weighted imaging, however, was clinically unacceptable. This ICP monitor creates a reduction in signal-to-noise ratio in the received signal during T2-weighted imaging and proton spectroscopic imaging, with the obtained images still radiologically interpretable. CONCLUSION: The Codman ICP monitor is sufficiently accurate and free of artifact generation to be used during most clinical MRI applications. This could enhance patient monitoring and safety.

Artifacts↗

A phantom study of the geometric accuracy of computed tomographic and magnetic resonance imaging stereotactic localization with the Leksell stereotactic system.

OBJECTIVE: To assess the spatial accuracy of magnetic resonance imaging (MRI) and computed tomographic stereotactic localization with the Leksell stereotactic system. METHODS: The phantom was constructed in the shape of a box, 164 mm in each dimension, with three perpendicular arrays of solid acrylic rod, 5 mm in diameter and spaced 30 mm apart within the phantom. In this study, images from two different MRI scanners and a computed tomographic scanner were obtained using the same Leksell (Elekta Instruments, Stockholm, Sweden) head frame placement. The coordinates of the rod images in the three principal planes were measured by using a tool provided with Leksell GammaPlan software (Elekta Instruments, Norcross, GA) and were compared with the physical phantom measurements. RESULTS: The greatest distortion was found around the periphery, and the least distortion (<1.5 mm) was present in the middle and most other areas of the phantom. In the phantom study using computed tomography, the mean values of the maximum errors for the x, y, and z axes were 1.0 mm (range, 0.2-1.3 mm), 0.4 mm (range, 0.1-0.8 mm), and 3.8 mm (range, 1.9-5.1 mm), respectively. The mean values of the maximum errors when using the Philips MRI scanner (Philips Medical Systems, Shelton, CT) were 0.9 mm (range, 0.4-1.7 mm), 0.2 mm (range, 0.0-0.7 mm), and 1.9 mm (range, 1.3-2.3 mm), respectively. Using the Siemens MRI scanner (Siemens Medical Systems, New York, NY), these values were 0.4 mm (range, 0.0-0.7 mm), 0.6 mm (range, 0.0-1.0 mm), and 1.6 mm (range, 0.8-2.0 mm), respectively. The geometric accuracy of the MRI scans when using the Siemens scanner was greatly improved after the implementation of a new software patch provided by the manufacturer. The accuracy also varied with the direction of phase encoding. CONCLUSION: The accuracy of target localization for most intracranial lesions during stereotactic radiosurgery can be achieved within the size of a voxel, especially by using the Siemens MRI scanner at current specifications and with a new software patch. However, caution is warranted when imaging peripheral lesions, where the distortion is greatest.

Humans↗

Computer-generated attenuation correction does not improve the accuracy of myocardial perfusion scintigraphy.

A short study was performed to determine if it is possible to increase the accuracy of thallium-201 (201T1) single photon emission tomographic myocardial perfusion imaging using computer-generated ('Chang') attenuation correction. The stress and rest myocardial perfusion studies from 22 patients with suspected or known ischaemic heart disease were reconstructed with and without "Chang' attenuation correction. For all patients, the scintigraphy results were compared with those of coronary angiography. Attenuation correction improved the accuracy of 201T1 myocardial perfusion imaging for defining myocardial ischaemia or infarction in 8% of coronary artery territories (23% of patients), but it was worse in 5% of coronary artery territories (14% of patients). These changes were not significant (McNemar's test). Therefore, computer-generated 'Chang' attenuation correction does not appear to improve the accuracy of myocardial perfusion scintigraphy. It is important that all techniques suggested to improve the accuracy of clinical images should be tested on patients before being widely used.

Coronary Angiography↗

Accuracy of a registration procedure for brain SPET and MRI: phantom and simulation studies.

Phantom experiments and simulations were performed to evaluate the significance of different error sources in a clinical registration procedure for brain SPET and MRI based on external markers. The results from the phantom experiments were used to adjust the error model for simulations. In the phantom experiments, 13-14 external markers were attached to the surface of a three-dimensional brain phantom for computing registration. Three internal test markers were used to estimate the accuracy of registration. The phantom was imaged with two different SPET and MRI devices. The mean root-mean-squared (RMS) residual of the locations of the test markers after registration using different combinations of four external markers varied from 3.5 +/- 1.0 to 5.2 +/- 1.3 mm depending on the imaging equipment and parameters used. The accuracy improved with an increasing number of external markers, from 3.2 +/- 0.5 to 4.9 +/- 0.5 mm for 6 markers and from 3.1 +/- 0.1 to 4.7 +/- 0.1 mm for 13 markers. In simulations, the external markers had an error comparable to the corresponding error in the phantom experiments. The error in the test markers was varied independently of that of the external markers. When the locating error of the test markers was removed, about 2 mm of the residuals of the test markers were found to come from this source. When an error comparable to the resolution of the original images (7-10 mm for SPET, 2 mm for MRI) was included in the test markers, the largest mean RMS residual after registration was smaller than the resolution error (8.8 +/- 1.1 mm). This was due to the accuracy of localization of the external markers and the fact that the direction of the error was random for each marker. The size of the registration error of an image volume was site-dependent, being minimal near the centre of mass of the external markers. When comparing the error with the spatial resolution of SPET, it was concluded that the accuracy of registration is not the limiting factor in region-of-interest analysis of registered images, provided that the design and attachment of the marker system are appropriate.

Brain↗

Does inadequate exercise lower the accuracy of myocardial perfusion scintigraphy?

The predictive accuracy of exercise myocardial perfusion scintigraphy (EMPS) in detecting coronary artery disease (CAD) in patients who fail to achieve an adequate level of exercise is not clear. This investigation was carried out in order to compare the sensitivity, specificity and accuracy of EMPS in adequate exercise patients with those in inadequate exercise patients. We have retrospectively compared the results of EMPS with coronary angiography (CAG). One hundred and forty-eight patients with both tests within 6 weeks were included. Adequate exercise was defined as > or = 85% maximally predicted heart rate for age. The overall sensitivity and specificity of EMPS to detect CAD were 92.5% (74/80) and 75%, (51/68), respectively. The sensitivity and specificity in adequate exercise patients were 94.1% (32/34) and 67.6% (23/34), whereas those in inadequate exercise patients were 91.3% (42/46) and 82.4% (28/34). The accuracy was 80.9% (55/68) and 87.5% (70/80), respectively. Patients with inadequate exercise had lower sensitivity but higher specificity of EMPS for detecting CAD, and achieved a higher accuracy than those with adequate exercise.

Adult↗

Diagnostic accuracy of radionuclide imaging using 131I nor-cholesterol or meta-iodobenzylguanidine in patients with hypersecreting or non-hypersecreting adrenal tumours.

The aim of this retrospective study was to evaluate the diagnostic accuracy of nor-cholesterol and meta-iodobenzylguanidine radionuclide imaging in two separate groups of patients with adrenal tumours to characterize lesions as adenoma or pheochromocytoma. We studied 75 patients (22 male and 53 female, mean age 47 +/- 15 years) with hypersecreting (n = 32) or non-hypersecreting (n = 43) unilateral adrenal tumours detected by computerized tomography or magnetic resonance scans. 131I nor-cholesterol adrenal scintigraphy was performed in 41 patients. Meta-[131I]iodobenzylguanidine (131I-MIBG) imaging was acquired in the other 34 patients. Pathology examinations (n = 58) or computerized tomography follow-up studies (n = 17) were obtained. Adrenal lesions were represented by 44 adenomas, four cysts, one myelolipoma, one pseudotumour, one ganglioneuroma, 16 pheochromocytomas, three carcinomas, four metastases and one sarcoma. Radionuclide studies were qualitatively evaluated and the corresponding results were classified as true positive, true negative, false positive and false negative. Diagnostic sensitivity, specificity and accuracy as well as positive and negative predictive values were calculated. The diagnostic values of nor-cholesterol scintigraphy in identifying adrenal adenomas were sensitivity 100%, specificity 71%, accuracy 95%, positive predictive value 94% and negative predictive value 100%; of note, two false positive cases were observed represented by a pheochromocytoma and a myelolipoma. The diagnostic values of MIBG scintigraphy in recognizing pheochromocytoma were sensitivity 100%, specificity 95%, accuracy 97%, positive predictive value 94% and negative predictive value 100%; only one false positive case occurred consisting of a carcinoma. It is concluded that, in the large majority of cases, adrenal scintigraphy using nor-cholesterol or MIBG is able to characterize specific lesions such as adenoma and pheochromocytoma, respectively. These findings show relevant clinical impact, particularly in patients with non-hypersecreting adrenal lasions. Radiotracer selection depends on clinical patient history and department availability; since benign adenomas are the most common cause of non-hypersecreting tumours, nor-cholesterol should be the first choice followed by MIBG if nor-cholesterol shows normal images. However, rare as well as unusual findings may be observed; nor-cholesterol uptake may occasionally be also found in non-adenoma tumours such as myelolipoma and pheochromocytoma. Similarly, MIBG accumulation may occur not only in lesions arising from medullary chromaffin tissue, but also rarely in cortical adrenal carcinoma.

19-Iodocholesterol↗

Sensitivity, specificity and accuracy of stress SPECT myocardial perfusion imaging for detection of coronary artery disease in the distribution of first-order branch vessels, using an anatomical matching of angiographic and perfusion data.

We sought to investigate the utility of stress single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) for the identification of coronary artery disease (CAD) in the distribution of first-order branch vessels. We evaluated 135 consecutive patients with coronary angiography and stress SPECT MPI. We anatomically matched angiography and SPECT to assess the sensitivity, specificity and accuracy of SPECT MPI for the detection of CAD in the distribution of first-order branches. Subgroup analysis for stress test performance and previous coronary artery bypass grafting (CABG) was also performed. The sensitivity, specificity and accuracy of stress SPECT MPI for the detection of CAD in the distribution of first-order branch vessels were all 67%. For isolated branch vessel CAD, stress SPECT MPI had a sensitivity of 44%. In patients without CABG, the sensitivity, specificity and accuracy for the detection of CAD in the distribution of first-order branch vessels were 71%, 67% and 68%, compared with 60%, 67% and 64% for patients with CABG. The sensitivity for isolated branch vessel CAD was 50% for patients without CABG, but only 29% for patients with CABG. The sensitivity and specificity for CAD in the distribution of branch vessels were similar for all patients for all stress test modalities and heart rate response (sensitivity, 64-69%; specificity, 61-69%). Stress SPECT MPI offers intermediate sensitivity, specificity and accuracy for the detection of CAD in the distribution of first-order coronary artery branch vessels. However, for isolated branch vessel CAD, stress SPECT has a lower sensitivity, particularly in patients with previous CABG.

Coronary Angiography↗

Comparison of repeat videokeratography: repeatability and accuracy.

PURPOSE: We compared the repeatability and accuracy of four commercially available videokeratography instruments and a manual keratometer. METHODS: Ten optometry students and two university employees who had no history of rigid contact lens wear and no soft contact lens wear within 6 months of the study were measured. Two independent measurements were taken on the right eyes only using the Alcon EyeMap EH-290 topography system (both manual and automatic focus), the EyeSys System 2000 corneal topography system, the Humphrey Mastervue topography system, the Humphrey Atlas topography system, and a Marco manual keratometer. A three-factor repeated measures analysis of variance with all factors repeated was performed using SAS and BMDP statistical software. Separate analyses were conducted for paracentral and peripheral data. To test accuracy, measurements were taken with the Alcon EyeMap automatic focus system, the EyeSys System 2000, the Humphrey Atlas system, and the Humphrey Mastervue system using four calibration spheres. RESULTS: There were no statistically significant differences in the repeatability of the instruments. The EyeSys corneal topography system had the most narrow 95% limits of agreement around the mean difference. The two Humphrey instruments performed similarly to the EyeSys. Although the Alcon EyeMap EH-290 had the widest 95% limits of agreement around the mean difference, it showed better repeatability when the manual focus was used compared with the automatic focus. The instruments varied in their level of accuracy, but the highest percentage of data points within +/- 0.37 D of the known values of the calibration spheres was found with the Humphrey Atlas. CONCLUSIONS: Although there were no statistically significant differences in repeatability, the EyeSys System 2000 had the highest repeatability, which may have clinical relevance. The accuracy measured in this study varied tremendously; however, the Humphrey Atlas was found to be the most accurate of the instruments tested.

Cornea↗

The accuracy and precision performance of four videokeratoscopes in measuring test surfaces.

In this study we evaluated the accuracy and precision of three placido-disk videokeratoscopes (the Keratron, Medmont and TMS) and one videokeratoscope that uses the raster-stereogrammetry technique (PAR-CTS) in elevation topography with six test surfaces. The test surfaces were a sphere, an asphere, a multicurve, and three bicurve surfaces. Each instrument performed well on certain test surfaces, but none of the instruments excelled on all of the surfaces. The results showed high accuracy of the Keratron and Medmont instruments in measuring the sphere, asphere, and multicurve surfaces, but not the bicurve surfaces. The precision of the Keratron and Medmont instruments were high. The TMS and PAR-CTS instruments showed poorer accuracy than the Keratron and Medmont instruments for the multicurve test surface but showed better performance for the bicurve surfaces. The PAR-CTS had the poorest performance in precision of the four instruments. The use of the Noryl spherical test surface instead of polymethyl methacrylate (PMMA) resulted in small differences in the accuracy performance of the placido-disk videokeratoscopes only.

Cornea↗

Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine.

STUDY DESIGN: Utility of using computed tomography to predict pedicle screw misplacement. OBJECTIVE: This study defines the sensitivity and specificity of predicting pedicle screw placement by experienced clinicians using a CT scan image. SUMMARY OF BACKGROUND DATA: In clinical and research settings, the method most commonly used to evaluate pedicle screws placement has been computed tomography. However, no current literature describes the accuracy of this method of evaluating screw placement. METHOD: Cobalt-chrome and titanium alloy pedicle screws of identical size were placed in six cadaveric human lumbar spine. Wide laminectomy was performed to allow complete visualization of the pedicles. Three consecutive lumbar levels were instrumented in each spine, giving 36 pedicle screw placements to identify. The instrumented spines were imaged, and four orthopaedic spine surgeons and a musculoskeletal radiologist were asked to read the images to identify the accuracy of screw placement within the pedicles. RESULTS: The sensitivity rate of identifying a misplaced screw was 67 +/- 6% for cobalt-chrome screws compared with 86 +/- 5% for titanium screws (P < 0.005). The specificity rates of radiographic diagnosis of misplaced pedicle screws were 66 +/- 10% for cobalt-chrome screws and 88 +/- 8% for titanium screws (P < 0.005). Similarly, a statistically significant difference was found in the sensitivity rates of identifying screws placed correctly in the pedicle: 70 +/- 10% for cobalt-chrome screws versus 89 +/- 8% for titanium screws (P < 0.005). Overall accuracy rates were 68 +/- 7% for cobalt chrome screws versus 87 +/- 3% for titanium screws (P < 0.002). CONCLUSION: Reliance on the computed tomography scan data alone in determining accuracy of pedicle screws can lead to inaccuracies in both clinical and research conditions.

Artifacts↗