Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ATMOSPHERIC PRESSURE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56Linked to original sources

Isolation and identification of process impurities in trimethoprim drug substance by high-performance liquid chromatography, atmospheric pressure chemical ionization liquid chromatography/mass spectrometry and nuclear magnetic resonance spectroscopy.

Twenty-two lots of recently synthesized trimethoprim drug substance, from five different manufacturers, in three different countries of origin, China, Israel and the United States, were investigated for the presence of impurities. A liquid chromatographic system, using gradient elution, and a mobile phase consisting of 0.25% TEA/0.1% formic acid (pH 5.8)--acetonitrile, was used to separate and detect two significant, recurring impurities in trimethoprim drug substance. The two impurities were isolated by preparative liquid chromatography and identified, using a combination of liquid chromatography/mass spectroscopy and nuclear magnetic resonance, as 2,4-diamino-5-(4-ethoxy-3,5-dimethoxybenzyl) pyrimidine and 2,4-diamino-5-(3-bromo-4,5-dimethoxybenzyl) pyrimidine. These impurities were not detected by the compendial method and were present at significant levels in 17 of the lots tested. Total impurity concentrations were in the range of 0.1-2.1%.

Atmospheric Pressure↗

On-line hyphenation of supercritical fluid extraction and two-dimensional high performance liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometer for the analysis of Ganoderma lucidum.

A novel on-line system combining supercritical fluid extraction (SFE) and two-dimensional high performance liquid chromatography (2D-HPLC) was developed. A trap column and two three-port valves were employed to couple SFE and 2D-HPLC system, which was composed of a CN column and a monolithic silica column, connected by a 10-port dual-position valve. The analytes extracted by supercritical CO2 were completely transferred to the 2D-HPLC system. After separation in two orthogonal modes, the eluents were delivered to APCI-tandem-MS for identification of the samples. In this way, sample preparation, separation, detection, and identification were integrated into an on-line system permitting analysis of the fruiting bodies of Ganoderma lucidum, and at least 73 components in the extract were resolved with calculated peak capacity of up to 1643.

Acetonitriles↗

Analysis of low-molecular-mass inorganic and organic anions by ion chromatography-atmospheric pressure ionization mass spectrometry.

Different nonvolatile mobile phases have been tested for the combination of ion-exchange chromatography combined with mass spectrometric detection of anions and organic acids. Buffer systems based on carbonate, sulfate, oxalate and citrate as the eluting species have been used. Among these, citrate proved to be the most versatile eluent allowing the separation of anions with absolute detection limits between 0.4 and 0.7 ng and of organic acids with detection limits between 0.4 and 4 ng in the non-suppressed mode. In the suppressed eluent mode iodate, bromate and chlorate could be separated using sodium carbonate as the mobile phase resulting in detection limits of 50 pg. The method was applied to the analysis of water samples containing oxyhalides originating from ozonization. Additionally, organic acids were separated by chromatographic separation techniques like reversed-phase, ion-pair or ion-exclusion chromatography and the compatibility with mass spectrometry was investigated with special respect to sensitivity of this detection mode.

Anions↗

Influence of the matrix on analyte fragmentation in atmospheric pressure MALDI.

In this paper, we report the measurement of the degree of analyte fragmentation in AP-MALDI as a function of the matrix and of the laser fluence. The analytes include p-OCH3-benzylpyridinium, three peptides containing the sequence EEPP (which cleave very efficiently at the E-P site), and three deoxynucleosides (dA, dG, and dC), which lose the neutral sugar to give the protonated base. We found that the matrix hardness/softness was consistent when comparing the analytes, with a consensus ranking from hardest to softest: CHCA >> DHB > SA approximately THAP > ATT > HPA. However, the exact ranking can be fluence-dependent, for example between ATT and HPA. Our goal here was to provide the scientific community with a detailed dataset that can be used to compare with theoretical predictions. We tried to correlate the consensus ranking with different matrix properties: sublimation or decomposition temperature (determined using thermogravimetry), analyte initial velocity, and matrix proton affinity. The best correlation was found with the matrix proton affinity.

Atmospheric Pressure↗

Simultaneous determination of thiabendazole and its major metabolite, 5-hydroxythiabendazole, in bovine tissues using gradient liquid chromatography with thermospray and atmospheric pressure chemical ionisation mass spectrometry.

A novel method is presented for the determination of thiabendazole and 5-hydroxythiabendazole in animal tissues. Samples are homogenised in buffer at pH=7.0, extracted with ethyl acetate and cleaned up using CN solid-phase extraction columns. Thiabendazole and 5-hydroxythiabendazole are separated chromatographically using gradient elution and analysed by liquid chromatography-mass spectrometry. Deuterated thiabendazole is employed as an internal standard for thiabendazole determination; 5-hydroxythiabendazole is quantified via external standards. Samples are screened by monitoring the protonated molecular ions at m/z=202 for thiabendazole, 206 for deuterated thiabendazole and 218 for 5-hydroxythiabendazole using thermospray LC-MS. Positives are confirmed by multiple ion monitoring using APCI LC-MS. Validation of the method was carried out at 50, 100 and 200 microg kg(-1). Recoveries for thiabendazole in bovine muscle, liver and kidney ranged from 96-103% with C.V.s between 0.7 and 4.8% and for 5-hydroxythiabendazole recoveries ranged from 70-85% with C.V.s between 3.1 and 11.5%.

Animals↗

Determination of heterocyclic aromatic amines in meat extracts by liquid chromatography-ion-trap atmospheric pressure chemical ionization mass spectrometry.

When protein-rich foods are processed under normal cooking conditions, heterocyclic aromatic amines (HAAs) can be generated at a few parts per billion level. In this work, we have analyzed the HAAs present in a lyophilized meat extract by means of a simplified solid-phase extraction procedure. All the analytes were collected in a single extract with recoveries in the range of 45.6-75.2%, so the analysis time has been greatly reduced. Problems derived from the less exhaustive purification of the extract have been solved by using MS(ion trap) detection. The RSD for quantification ranged from 2.1% to 5.1% for run-to-run precision and from 5.2% to 11% for day-to-day precision. The limits of detection for standard solutions ranged from 20 to 150 pg injected. For the meat extract analyzed limits of detection from 0.9 to 11.2 ng g(-1) were obtained. Results of the quantification are in agreement with those obtained using different clean-up procedures.

Amines↗

Comparison of the repeatability of quantitative data measured in high-performance liquid chromatography with UV and atmospheric pressure chemical ionization mass spectrometric detection.

A detailed comparison of the repeatability of the retention times, the peak efficiencies and the peak areas of a dozen probe compounds achieved in HPLC, using either HPLC-UV or HPLC-MS for detection purpose, is reported. Three groups of conventional analytes, each one separated under a different set of experimental conditions, were selected for this study. Most of the compounds are basic, the other ones being neutral. The repeatabilities of the retention times do not exhibit any influence of the mode of detection. However, the repeatabilities of the peak areas and the column efficiencies are generally (although not always) better in HPLC-UV than that in HPLC-MS. On average, the precision for the UV peak area detection was 2.5% versus 6.8% for MS detection. Experimental results show that the response factor of the UV detector is more constant than that of the MS detector, probably because the HPLC flow-rate was sufficiently stable. The results obtained in the different tests are discussed.

Atmospheric Pressure↗

Simultaneous determination of urinary cystathionine, lanthionine, S-(2-aminoethyl)-L-cysteine and their cyclic compounds using liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization.

A measurement system for cystathionine (Cysta) lanthionine (LT), and S-(2-aminoethyl)-L-cysteine (AEC), and reduced products of their ketimines, perhydro-1,4-thiazepine-3,5-dicarboxylic acid (PHTZDC), 1,4-thiomorpholine-3,5-dicarboxylic acid (TMDA) and 1,4-thiomorpholine-3-carboxylic acid (TMA) in the urine samples of a patient with cystathioninuria and normal human subjects has been developed, using column liquid chromatography-mass spectrometry. The recoveries were about 90-105% for Cysta, LT and AEC, and about 77-87% for PHTZDC, TMDA and TMA after ion-exchange treatment. The concentrations of Cysta and PHTZDC in the urine of a patient with cystathioninuria were much higher compared with those in the urine of normal human subjects. The concentrations of AEC and TMDA were almost the same. LT and TMA could not be detected in the urine samples by this method. This method proved useful for the determination of sulfur-containing amino acids and their cyclic compounds in biological samples.

Alanine↗

A validated method for the determination of nicotine, cotinine, trans-3'-hydroxycotinine, and norcotinine in human plasma using solid-phase extraction and liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry.

A liquid chromatographic-mass spectrometric method for the simultaneous determination of nicotine, cotinine, trans-3'-hydroxycotinine, and norcotinine in human plasma was developed and validated. Analytes and deuterated internal standards were extracted from human plasma using solid-phase extraction and analyzed by liquid chromatography/atmospheric pressure chemical ionization-mass spectrometric detection with selected ion monitoring (SIM). Limits of detection and quantification were 1.0 and 2.5 ng/ml, respectively, for all analytes. Linearity ranged from 2.5 to 500 ng/ml of human plasma using a weighting factor of 1/x; correlation coefficients for the calibration curves were > 0.99. Intra- and inter-assay precision and accuracy were < 15.0%. Recoveries were 108.2-110.8% nicotine, 95.8-108.7% cotinine, 90.5-99.5% trans-3'-hydroxycotinine, and 99.5-109.5% norcotinine. The method was also partially validated in bovine serum, owing to the difficulty of obtaining nicotine-free human plasma for the preparation of calibrators and quality control (QC) samples. This method proved to be robust and accurate for the quantification of nicotine, cotinine, trans-3'-hydroxycotinine, and norcotinine in human plasma collected in clinical studies of acute nicotine effects on brain activity and on the development of neonates of maternal smokers.

Atmospheric Pressure↗

Analysis of olive and hazelnut oil mixtures by high-performance liquid chromatography-atmospheric pressure chemical ionisation mass spectrometry of triacylglycerols and gas-liquid chromatography of non-saponifiable compounds (tocopherols and sterols).

We analysed the triacylglycerol, tocopherol and sterol composition of hazelnut oil, olive oil and their mixtures (90% olive oil with 10% hazelnut oil, 70% olive with 30% hazelnut oil and 50% olive oil with 50% hazelnut oil). The main triacylglycerols were 1,2,3-trioleylglycerol, 2,3-dioleyl-1-palmitoylglycerol, 2,3-dioleyl-1-linoleylglycerol and 2,3-dioleyl-1-stearoylglycerol. Non-saponfiable compounds (tocopherols and sterols) were derivatised as O-trimethylsilyl ethers. Alpha-tocopherol was the main vitamin E isomer in all samples; however, small amounts of beta-tocopherol and gamma-tocopherol were also found. Beta-sitosterol and delta5-avenasterol were the principal sterols in all samples; campesterol and stigmasterol were minor sterol compounds in all samples. Obtusifoliol, which was a major sterol in olive oil and oil mixtures, was not found in hazelnut oil. The discriminant analysis showed that hazelnut oil, olive oil and oil mixtures were clearly separated according to their triacylglycerol composition.

Atmospheric Pressure↗

Effect of acute exposure to reduced atmospheric pressures on body weight, food intake and body composition of growing rats.

Growing male rats were exposed to simulated altitudes of 1850, 2900, 4100, 5450 or 7100 m in a hypobaric chamber to determine the effects of altitude on body weight gain and food intake as function of time of exposure. Female rats were exposed to a simulated altitude of 7100 m for 24 h to determine the effect of altitude on body composition. The results obtained indicate that in growing rats exposed to acute simulated altitude the initial body weight loss and the depressed growth rate, on one hand, and the reduced food intake, on the other hand, are related to the degree of the altitude; the parameters are not affected at altitudes below 1 850 m; the initial weight loss is not solely due to reduction in food intake, the additional loss being attributed to the added stress of hypoxia; the body weight loss occurs without marked alterations in body composition, although a tendency to dehydration exists; and the body compositional changes are the reflection of the altitude-induced hypophagia.

Altitude↗

Determination of chiral sulfoxides in plasma by normal-phase liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

A sensitive and specific assay has been developed and validated for the separation of a chiral sulfoxide drug candidate with simultaneous determination of the corresponding sulfide and sulfone in plasma by normal-phase LC-MS-MS. Separation was achieved on a Chiralpak AD (100 x 2.1 mm) column with a 2-propanol-hexane (80:20) mobile phase within 7 min. Aqueous mobile phase (2-propanol-10 mM ammonium acetate, 75:25) was added post-column prior to introduction into the heated nebulizer interface of a Sciex API 3 plus mass spectrometer, to avoid the explosion hazard of hexane-containing mobile phases in the presence of a corona discharge. The linear range of this assay was 5-2500 ng/ml. The accuracy and precision of the chiral sulfoxides, the sulfide and the sulfone were within +/- 15% across the linear range. The limit of quantitation for each component was 5 ng/ml based on the extraction of 0.25 ml plasma. The recovery for each component was between 82 and 120%. This assay was sufficiently sensitive and specific to support pre-clinical development studies in rats, dogs and monkeys.

Animals↗

Quantification of isosorbide 5-mononitrate in human plasma by liquid chromatography-tandem mass spectrometry using atmospheric pressure photoionization.

Isosorbide 5-mononitrate (5-ISMN) is an organic nitrate widely used for its vasodilating properties in the treatment of angina pectoris. In the present study, an efficient, sensitive, robust method was developed for the determination and quantification of isosorbide 5-mononitrate, in human plasma, by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS), using photospray ionization. Isosorbide 5-mononitrate was extracted from 0.5 mL human plasma by liquid-liquid extraction (LLE). The method had a chromatographic run of 2.0 min using a C(8) analytical column (100 mm x 2.1 mm i.d.) and the linear calibration curve over the range was linear from 20 to 2000 ng mL(-1) (r(2)>0.995). The between-run precision, based on the relative standard deviation replicate quality controls, was 7.9% (60 ng mL(-1)), 5.2% (300 ng mL(-1)) and 7.0% (1800 ng mL(-1)). The between-run accuracy was 94.9%, 94.1% and 88.8% for the above-mentioned concentrations, respectively. The method herein described was employed in a bioequivalence study of two tablet formulations of isosorbide 5-mononitrate 40 mg.

Atmospheric Pressure↗

Atmospheric pressure photoionization applied to quantitation of cyproterone acetate in human plasma.

Cyproterone acetate [6-chloro-1beta,2beta-dihydro-17alpha-hydroxy- 3'H-cyclopropa(1,2)-pregna-1,4,6-triene-3,20-dione acetate] is a powerful antiandrogen used in the treatment of women suffering from disorders associated with androgenization such as hirsutism and acne. A fast, sensitive, and robustness method is developed for the determination and quantitation of cyproterone acetate in human blood plasma by liquid chromatography coupled with tandem mass spectrometry. Cyproterone acetate is extracted from 0.2 mL human plasma by liquid-liquid extraction. The method has a chromatographic run of 4.5 min, using a C18 analytical column (100- yen 2.1-mm i.d.), and the linear calibration curve over the range is linear from 1 to 500 ng/mL (r2 > 0.994). The between-run precision, based on the relative standard deviation replicate quality controls, is 96.2% (3 ng/mL), 97.5% (120 ng/mL), and 99.1% (400 ng/mL). The between-run accuracy was +/- 2.7%, 3.1%, and 4.8% for the previously mentioned concentrations, respectively. The method is employed in a bioequivalence study of two tablet formulations of cyproterone acetate (100 mg).

Androgen Antagonists↗

Method to determine 4-oxo-retinoic acids, retinoic acids and retinol in serum and cell extracts by liquid chromatography/diode-array detection atmospheric pressure chemical ionisation tandem mass spectrometry.

Retinoic acid isomers, 4-oxo-retinoic acid isomers and retinol are present in the serum of mammals. In this study a high-performance liquid chromatography (HPLC) separation, sample preparation and tandem mass spectrometry (MS/MS) method was established for quick and easy sample preparation and sensitive determination of retinoids such as all-trans-4-oxo-retinoic acid, 13-cis-4-oxo-retinoic acid, 13-cis-retinoic acid, 9-cis-retinoic acid, all-trans-retinoic acid and retinol in serum and cell extracts. Serum samples were simply treated with three times the volume of isopropanol, dried under vacuum, taken up in the HPLC solvent and immediately put into the autosampler for an automated single-run HPLC analysis. With this MS/MS method we were able to detect 7 pg and quantify 20 pg of all-trans-retinoic acid, 4-oxo-all-trans-retinoic acid and retinol directly on-column and were able to determine a concentration as low as 0.2 ng/mL in ethanolic standards and in biological samples. This method allows ultra-sensitive detection, excellent selectivity and a very simple sample preparation to determine retinoic acids, 4-oxo-retinoic acids and retinol in serum and cell extracts for the study of endogenous retinoids.

Atmospheric Pressure↗

A direct technique for the simultaneous determination of 10 drug candidates in plasma by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry interfaced to a Prospekt solid-phase extraction system.

New drug candidates are being synthesized at an ever increasing rate and, until recently, the pharmacokinetics of only a few of these could be evaluated. Our laboratory is taking a novel approach to rapid multiple pharmacokinetic screening of potential drug candidates in which mixtures of new substances are co-administered to animals and analyzed simultaneously in plasma using liquid chromatography with tandem MS/MS detection in conjunction with a Prospekt automated on-line solid-phase extraction system. Plasma is sampled via an autosampler and extracted by the Prospekt with the eluent being introduced directly via a reverse phase HPLC column and a heated nebulizer interface to the mass spectrometer. Generic extraction and chromatographic conditions generally give good recoveries. The chromatographic run-times are less than 8 min. The accuracy and precision of these assays are carefully controlled with recoveries generally in the range 80-120% and coefficients of variation less than 20%. Lower quantifiable limits range from 2.5 to 5 ng ml-1. This approach considerably reduces the number of animals needed to screen drug candidates and its power is illustrated by determination of the pharmacokinetics of 10 substances after their simultaneous administration to dogs.

Animals↗

Determination of aniline derivatives in oils related to the toxic oil syndrome by atmospheric pressure ionization-tandem mass spectrometry.

In 1981, an unknown disease appeared in Spain, the Spanish Toxic Oil Syndrome. Nowadays and despite all efforts, the etiological agent is still unknown. Early studies showed a link between this illness and the consumption of denatured rapeseed oil fraudulently processed and marketed as edible oil. Two families of aniline derivatives present in these oils (fatty acid anilides and acylated phenyl amino propanediol derivatives or PAPs) were found to be good chemical markers of toxic oils. In this work, a new method has been developed to analyze these aniline derivatives in oil samples by HPLC-MS and HPLC-MS/MS with an API source. For their quantification, three different internal standards were used, one for anilides and two for PAPs. Quantification limits were 8 ppm for anilides and 0.2 ppm for PAPs. Anilides and PAPs were found in marker-positive samples at levels up to 50,000 and 330 ppm, respectively. The relative abundance of the different fatty acid anilides and PAPs correlates with the fatty acid composition of the oils. More than 2,600 different samples were analyzed by this method in the most exhaustive screening of suspected toxic oils carried out to date.

Aniline Compounds↗

Simultaneous determination of heroin 6-monoacetylmorphine, morphine, and its glucuronides by liquid chromatography--atmospheric pressure ionspray-mass spectrometry.

A new analytical technique has been developed for the simultaneous determination of heroin, 6-monoacetylmorphine, morphine, morphine-6- and 3-glucuronides, and codeine in serum using liquid chromatography coupled with ionspray mass spectrometry. The analytes and the internal standard, nalorphine, were subjected to solid-phase extraction (SPE) using ethyl SPE columns before chromatography. The chromatographic separation of the analytes was achieved using a normal phase column and a water-methanol-acetonitrile-formic acid mobile phase at a flow rate of 230 microL/min. The mass spectrometer was operated in selected-ion monitoring mode. Under these conditions, the limit of quantitation was 0.5 ng/ml for heroin, 4 ng/ml for 6-monoacetylmorphine, 4 ng/ml for morphine, 1 ng/ml for morphine-3-glucuronide, 4 ng/ml for morphine-6-glucuronide, and 4 ng/mL for codeine. Serum levels of heroin metabolites were determined in C57BL/6 inbred mice after a dose of 20 mg/kg heroin administered subcutaneously. 6-monoacetylmorphine showed a peak concentration of 0.93 micrograms/mL serum at 3 min, whereas morphine and morphine-3-glucuronide achieved their peak concentrations of 9.6 and 2.9 micrograms/mL serum at 10 and 20 min, respectively. Finally, the absence of morphine-6-glucuronide and codeine excluded the possibility of their formation from morphine in this animal model.

Animals↗