Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “quantification”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

Relative quantification of tau-related peptides using guanidino-labeling derivatization (GLaD) with online-LC on a hybrid ion trap (IT) time-of-flight (ToF) mass spectrometer.

Development of a quantification method based on isotopic variants of O-methyl isourea (OMIU) in conjunction with reversed-phase (RP) liquid chromatography (LC) electrospray mass spectrometry is described for determining the relative quantification of tau-related peptides Ac-VQIVXK-NH2. Extracted ion chromatograms of the mass spectrometric data derived from online microcapillary LC separation identifies the retention times of the isotopically derivatized peptides together with their ion abundances. Data-dependent MSMS analysis of both derivatized variants of the same peptide provides a complementary method for identification and resolution between isobaric species. In addition, with respect to offline LC MALDI a larger number of analogues are detected and formation of amyloid is also observed for the aspartic acid and histidine-containing peptides.

Amyloid↗

Quantification of free mycophenolic acid and its glucuronide metabolite in human plasma by liquid-chromatography using mass spectrometric and ultraviolet absorbance detection.

The immunosuppressant drug mycophenolic acid (MPA) and its major metabolite, mycophenolic acid glucuronide (MPAG), are highly bound to albumin. An HPLC-tandem-MS (HPLC/MS/MS) and an HPLC-UV assay were developed to measure free (unbound) concentrations of MPA and MPAG, respectively. Ultrafiltrate was prepared from plasma (500 microl) by ultrafiltration at 3000 x g for 20 min (20 degrees C). Both MPA and MPAG were isolated from ultrafiltrate (100 microl) by acidification and C18 solid-phase extraction. Free MPA was measured by electrospray tandem mass spectrometry using selected reactant monitoring (MPA: m/z 338.2--> 206.9) in positive ionisation mode. Chromatography was performed on a PFPP column (50 mm x 2 mm, 5 microm). Total analysis time was 7 min. The assay was linear over the range 1-200 microg/l with a limit of quantification of 1 microg/l. The inter-day accuracy and imprecision of quality controls (7.5, 40, 150 microg/l) were 94-99% and < 7%, respectively. Free MPAG was chromatographed on a C18 Nova-Pak column (150 mm x 3.9 mm, 5 microm) using a binary gradient over 20 min. The eluent was monitored at 254 nm. The assay was linear over the range 1-50 mg/l with the limit of quantification at 2.5 mg/l. The inter-day accuracy and imprecision of quality controls (5, 20, 45 mg/l) was 101-107% and < 8% (n = 4), respectively. For both methods no interfering substances were found in ultrafiltrate from patients not receiving MPA. The methods described have a suitable dynamic linear range to facilitate the investigation of free MPA and MPAG pharmacokinetics in transplant patients. Further, this is the first reported HPLC-UV method to determine free MPAG concentrations.

Chromatography, High Pressure Liquid↗

Development of a gas chromatographic test for the quantification of the biomarker 3-bromopropionic acid in human urine.

An accurate and precise method was developed for the detection and quantification of 3-bromopropionic acid (3-BPA), a metabolite and biomarker for exposure to 1-bromopropane (1-BP). 1-BP is used as an industrial solvent and exposure is a health concern for industrial workers due to its toxicity. It has been associated with neurological disorders in both animals and humans. Urine sample preparation for the determination of 3-BPA consisted of liquid-liquid extraction (LLE) with ethyl acetate and silylation with N-methyl-N-[tert-butyldimethylsilyl]trifluoroacetamide (MTBSTFA). Quantification was by means of a gas chromatograph (GC) equipped with a mass selective detector (MSD) using a dimethylpolysiloxane (HP-1) capillary column and 3-chloropropionic acid was used as an internal standard in the procedure. Demonstrated accuracy and precision during this method's validation was good; recovery varied between 93 and 98% with relative standard deviations (R.D.S.) of 5.7% or less. The limit of detection (LOD) for the procedure was approximately 0.01microg/ml 3-BPA in urine. These data and other factors of the development and validation of this test method will be discussed.

Biomarkers↗

Quantification of urinary 5-aminolevulinic acid by gas chromatography-mass spectrometry.

In this report, we describe a method for the specific quantification of urinary 5-aminolevulinic acid. It is based on gas chromatographic mass spectrometric measurement of the trimethylsilyl ester of the ethylacetoacetate pyrrole derivative of 5-aminolevulinic acid. Selected ion monitoring (SIM) was used for quantification using 3-hydroxymyristic acid as an internal standard. The detection limit of this method was 0.1 nmol/ml. This method was applied to the determination of urinary 5-aminolevulinic acid from a tyrosinemia type I patient and normal subjects, and 21.4 mmol/mol creatinine and 0.54+/- 0.49 mmol/mol creatinine (n = 7), respectively, were detected. Less than 0.2 ml urine was sufficient for the determination of 5-aminolevulinic acid in healthy subjects.

Aminolevulinic Acid↗

Simultaneous quantification of beclomethasone dipropionate and its metabolite, beclomethasone 17-monopropionate in rat and human plasma and different rat tissues by liquid chromatography-positive electrospray ionization tandem mass spectrometry.

A sensitive, rapid and selective liquid chromatography-positive electrospray ionization tandem mass spectrometry (LC-(ESI+)-MS-MS) method has been developed and validated for the simultaneous quantification of beclomethasone dipropionate (BDP) and its active metabolite, beclomethasone 17-monopropionate (17-BMP) in rat plasma and different tissues using fluticasone propionate (FP) as the internal standard. The method was validated over a linear range from 0.05 to 5 ng/ml for both analytes. A solid-phase extraction procedure was used for plasma samples and a liquid-liquid extraction procedure for tissues samples (lung, liver and kidney). The between-day and within-day coefficients of variation for all compounds were </= 20% at the concentrations of lower limit of quantification (LLOQ) and </= 15% at other quality control concentrations. The same method was also partially validated for human plasma. The utility of this assay was demonstrated by monitoring BDP and 17-BMP plasma and tissue concentrations in an animal study designed for evaluation of pulmonary targeting after intratracheal administration of BDP dry powder.

Animals↗

Quantification of phosphoproteins with global internal standard technology.

Global internal standard technology (GIST) is being developed for the quantification of all primary structure and post-translational variants of proteins in a proteome. This paper is directed at an analysis of phosphorylation, primarily of serine and threonine. Quantification was achieved by acylation of primary amino groups in peptide cleavage fragments of proteins with isotopically coded derivatizing agents. Peptides from controls were globally coded with an isotopically "light" form of the reagent while those from experimental samples were coded with a "heavy" form of the reagent. The two types coding reagents used in this work were N-hydroxyl succinimide derivatives of acetate and 4-trimethylammoniumbutyrate. Heavy isotope forms were produced by deuteration of methyl groups. Subsequent to coding and mixing, the two samples were passed through a Ga(III) immobilized metal affinity chromatography (IMAC) column and the selected peptide fraction was further resolved by reversed-phase chromatography (RPC) and analyzed by mass spectrometry (MS). Relative differences in phosphopeptide concentration between samples were derived from isotope ratio measurements of the peptide isoforms observed in mass spectra. The method was validated with model peptides.

Amino Acid Sequence↗

Quantification of a novel retinoic acid metabolism inhibitor, 4-(1H-imidazol-1-yl)retinoic acid (VN/14-1RA) and other retinoids in rat plasma by liquid chromatography with diode-array detection.

A simple reversed phase high performance liquid chromatographic (HPLC) method was developed for the separation and quantification of a novel retinoic acid metabolism inhibitor, 4-(1H-imidazol-1-yl)retinoic acid (VN/14-1RA), and other retinoids in rat plasma. VN/14-1RA, alone or in combination with ATRA, is effective at inhibiting the proliferation of prostate and breast cancer cell lines in vitro. Aliquots of rat plasma were spiked with the retinoids followed by addition of acetonitrile for precipitation of plasma proteins. The decanted supernatant was evaporated under a stream of nitrogen and reconstituted in acetonitrile. Analysis was accomplished by injection of an aliquot of the reconstituted sample into an HPLC system consisting of a Zorbax Rx-C18 column and a diode array detector. A mobile phase composed of ammonium acetate (0.1 M), acetic acid solution (2% (v/v)) and methanol at a flow rate of 1.0 mL/min was used for gradient elution. The recoveries for all compounds ranged from 65 to 85% regardless of the concentrations examined. The HPLC assay was linear over the range 0.10-5.0 microg/mL (CV < 10%) with a limit of quantification of 100 ng/mL for VN/14-1RA. A one-compartment model with apparent first-order elimination was used to describe the plasma concentration-time profile for VN/14-1RA after intravenous administration. The mean terminal elimination half-life (t(1/2)) was 19.0 +/- 3.2 min. This HPLC method is useful for the analysis and evaluation of the pharmacokinetics of VN/14-1RA in rats.

Animals↗

Simultaneous quantification of alprazolam, 4- and alpha-hydroxyalprazolam in plasma samples using liquid chromatography mass spectrometry.

A sensitive and specific method was developed for quantification of alprazolam and its two metabolites 4-hydroxyalprazolam and alpha-hydroxyalprazolam in plasma. The work up procedure was solid phase extraction. Liquid chromatography-mass spectrometry (LC-MS) was used for separation, detection and quantification of the analytes. The limit of quantitation (LOQ) was 0.05 ng/mL for alprazolam and the two metabolites. The extraction recovery was more than 82% for alprazolam and its metabolites. The within- and between-assay coefficients of variation were in the range of 1.9-17.9%. The method was used for determination of the pharmacokinetics parameters of alprazolam and its two metabolites in healthy Caucasian subjects who ingested 1mg of alprazolam.

Alprazolam↗

Determination and quantification of alpha,beta,gamma,delta-unsaturated aldehydes as pentafluorobenzyl-oxime derivates in diatom cultures and natural phytoplankton populations: application in marine field studies.

Reactive alpha,beta,gamma,delta-unsaturated aldehydes and oxo-acids produced by marine diatoms upon cell damage interfere negatively with the reproduction success of their grazers. A simple, sensitive and specific method based on gas-chromatography coupled to mass spectrometry (EI or CI/EC) was developed for the quantification of these deleterious substances in laboratory diatom cultures and in natural phytoplankton populations. For aldehyde quantification, diatom containing samples are damaged in the presence of O-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine hydrochloride (PFBHA.HCl) which leads to an in situ derivatisation without inhibition of the biosynthesis of the aldehydes. The oxime derivates of oxo-acids were in addition reacted with N-tert-butyldimethylsilyl-N-methyl-trifluoracetamide (MTBSTFA).

Aldehydes↗

Development of a headspace gas chromatographic test for the quantification of 1- and 2-bromopropane in human urine.

A test procedure was developed for the detection and quantification of 1- and 2-bromopropane in human urine. 1-Bromopropane (1-BP) is a commonly used industrial solvent, and 2-bromopropane (2-BP) is often found as an impurity component in industrial grade 1-BP. Both compounds are a health concern for exposed workers due to their chronic toxicity. Bromopropanes have been associated with neurological disorders in both animals and humans. Sample preparation consisted of diluting urine with water and fortification with 1-bromobutane (1-BB), which was used as an internal standard; then each sample was sealed in a headspace vial. A static-headspace sampler (Teledyne-Tekmar Model 7000) was used to heat each sample at 75 degrees C for a 35-min equilibrium time. Quantification was by means of a gas chromatograph (GC) equipped with an electron capture detector (ECD) and a dimethylpolysiloxane (DB-1) capillary column. A recovery study using fortified urine samples at multiple concentrations (0.5-8 microg/ml) demonstrated full recovery; 104-121% recovery was obtained. Precision ranged from 5 to 17% for the 15-20 spiked samples used at each concentration, which were analyzed over multiple experimental trial days. The limit of detection (LOD) for this test procedure was approximately 2 ng/ml 1-BP and 7 ng/ml 2-BP in urine. A recovery study of 1- and 2-BP from fortified urine stored in vials appropriate for field collection was also completed. These results and other factors of the development and validation of this test procedure will be discussed.

Chromatography, Gas↗

A sensitive liquid chromatography-tandem mass spectrometry method for the quantification of mometasone furoate in human plasma.

A robust, rapid, selective and sensitive liquid chromatography-negative atmospheric pressure chemical ionization (LC-(APCI(-))-MS-MS) method has been developed for the quantification of mometasone furoate (MF) in human plasma utilizing a solid-phase extraction clean-up step and 13C-fluticasone propionate as internal standard. The intra- and inter-day coefficients of variation were < or = 15% and the lower limit of quantification (LLOQ) was 15 pg/ml. This method is ideally suited for pharmacokinetic investigations of low MF levels following inhalation of MF.

Anti-Inflammatory Agents↗

Quantification of NC100668, a new tracer for imaging of venous thromboembolism, in human plasma using reversed-phase liquid chromatography coupled with electrospray ionization ion-trap mass spectrometry.

NC100668 is being developed as a new tracer for radiopharmaceutical imaging of venous thromboembolism. NC100668 consists of a targeting peptide of 13 amino acids with a (99m)Tc-binding chelator linked to the C-terminal amino acid. The present report describes a method for quantification of NC100668 in human citrated plasma. The method is based on solid-phase extraction followed by reversed-phase liquid chromatography using a gradient of water and acetonitrile with 0.1% formic acid. The chromatographic system was coupled on-line with an electrospray mass spectrometer. The analyses were performed by selective ion monitoring of the [M+2H]2+ and the [M+3H]3+ ions of NC100668 and an internal standard which was identical to NC100668 except for not being iodinated in the tyrosine residue. The limit of quantification of the method was 2ng NC100668/ml plasma. The calibration curve ranged from 2 to 250 ng NC100668/ml plasma and was fitted to a linear equation with a weighing factor of 1/y2 and found to be highly reproducible. The total precision of the method, expressed as the relative standard error of the mean, was 23.2, 8.8 and 14.7% for the low, medium and high control samples, respectively. The accuracy of the method was 108.5, 100.0 and 105.0% for the low, medium and high control samples, respectively. NC100668 was stable in human plasma during at least three freeze/thaw cycles, during 30 h on dry ice and up to 3 months when stored in a -20 degrees C freezer.

Chromatography, Liquid↗

Quantification of ACE inhibiting peptides in human plasma using high performance liquid chromatography-mass spectrometry.

An HPLC-MRM-MS method was developed for the quantification of 17 small ACE inhibiting (ACEI) peptides in plasma samples collected from human volunteers after the consumption of a peptide-enriched drink. The assay shows the high selectivity and sensitivity necessary to monitor small changes in the levels of the ACEI peptides after consumption of drinks developed to effect lowering of the blood pressure. Four different sample preparation methods were tested and evaluated. The final sample preparation method selected is simple and effective and consists mainly of the removal of proteins by acidification and heating, followed by a large volume injection. Additional sample preparation steps such as solid phase extraction and liquid/liquid partitioning were studied. Although they resulted in cleaner extracts, losses of specific peptides such as SAP were frequently seen. The isotope labeled form of one of the peptides to be quantified, [U(13)C]IPP, was used as an internal standard. The limit of detection of the assay is below 0.01 ng ml(-1). The limit of quantification is between 0.05 and 0.2 ng ml(-1), which is approximately 10% of the expected peptide concentration in plasma based on a normal diet. The intra- and inter-day relative standard deviations for all peptides have shown to be below 25% and the method has an accuracy of better than 75%. The long-term stability is good. At least 200 samples could be analysed before the system had to be cleaned. The assay has been successfully applied to blood samples collected from volunteers during a human trial.

Angiotensin-Converting Enzyme Inhibitors↗

Quantification of biotin in feed, food, tablets, and premixes using HPLC-MS/MS.

Two sensitive and specific methods for quantification of biotin in feed, food, tablets, and premixes based on HPLC-MS/MS have been developed and validated. Depending on sample matrix and biotin content different extraction procedures and HPLC conditions were applied. Key steps in sample preparation were an alkaline extraction or a hydrolysis with sulphuric acid followed by enzymatic digest with papain. For many samples with low biotin content the latter combination of extraction steps was shown to be necessary for an optimal release of biotin from the matrix. The first time synthesis of deuterated biotin for use as internal standard allowed the compensation of losses during sample work-up and ion suppression during HPLC-MS/MS analysis. The new methods are faster than the commonly used microbiological assay using Lactobacillus plantarum. Additionally, they have a higher specificity as results for biotin are based on determination of a chemically defined compound, and not of a biological activity. Quantification is applicable to samples with a biotin content >100 microg/kg. Results obtained with the new methods have been compared with those of the microbiological assay, and were in good agreement.

Animal Feed↗

Quantification of O6-methyl and O6-ethyl deoxyguanosine adducts in C57BL/6N/Tk+/- mice using LC/MS/MS.

The carcinogenicity of many alkylating agents is derived from their ability to form persistent DNA adducts that induce mutations. This paper presents and validates methodology, based on LC with tandem mass spectrometry, for the separate or concurrent quantification by isotope dilution of O(6)-methyl-2'-deoxyguanosine (O(6)Me-dG) and O(6)-ethyl-2'-deoxyguanosine (O(6)Et-dG) DNA adducts. The limits of quantification were estimated to be < or =0.2 adducts/10(8) nucleotides for either adduct. This sensitivity permitted evaluation of adduct levels in livers from separate groups of untreated adult C57BL/6N/Tk(+/-) and C57BL/6N X Sv129 mice (undetectable to 5.5+/-6.7 O(6)Me-dG/10(8) nucleotides; undetectable to 0.04 O(6)Et-dG/10(8) nucleotides). Treatment of adult C57BL/6N/Tk(+/-) mice with equimolar doses (342micromol/kg body weight) of N-methyl-N-nitrosourea and N-ethyl-N-nitrosourea produced adduct levels in liver of 1700+/-80 O(6)Me-dG/10(8) nucleotides and 260+/-60 O(6)Et-dG/10(8) nucleotides, respectively, when assessed 4h after dosing. These methods should be useful for evaluations of DNA adducts in relation to cellular processes that modify carcinogenic and toxicological responses in experimental animals and humans.

Animals↗

Quantification of fluorotelomer-based chemicals in mammalian matrices by monitoring perfluoroalkyl chain fragments with GC/MS.

Perfluorocarboxylic acids (PFCAs), namely perfluorooctanoic acid (PFOA) and perfluorononanoic acid (PFNA), have been identified as persistent, bioaccumulative and potentially toxic compounds. The structural analog, 8-2 fluorotelomer alcohol (8-2 fTOH) is considered the probable precursor of these stable metabolites. Because simultaneous quantification is needed for volatile and non-volatile perfluorinated chemicals (PFCs) in complex matrices, a GC/MS method was developed and tested based on selected ion monitoring of perfluorinated alkyl parent chain fragment ions. Although the method requires a derivatization step, combined GC/MS analysis of PFCA-me's and FTOHs increases analytical efficiency and decreases sample analysis time. The method instrument detection limits are between 7.1 and 24.5 ng/mL extract (MTBE), and the method quantification limits are below 50 ng/mL serum or ng/g liver for all PFCs investigated. Recoveries from mouse serum and liver homogenates, which were spiked with FTOHs and PFCAs at levels of 25 and 200 ng/mL or ng/g, ranged from 81 to 101%. Finally, the utility of the method was demonstrated by dosing male CD-1 mice with 30 mg/kg-BW of 8-2 fTOH and quantifying PFCs 6h post-treatment. The advantages of this method are (1) the simultaneous detection of both volatile and non-volatile fluorotelomer-based chemicals in complex matrices, such as mammalian tissues, (2) as a confirmatory method to LC-MS/MS, and (3) as an alternative method of analysis for laboratories without access to LC-MS/MS.

Animals↗

A simple and rapid HPLC/UV method for the simultaneous quantification of theophylline and etofylline in human plasma.

A simple, sensitive and selective high performance liquid chromatography (HPLC) method with ultraviolet detection (272 nm) was developed and validated for the simultaneous quantification of theophylline and etofylline in human plasma. Following rapid sample preparation, the analytes and internal standard (hydrochlorothiazide) were separated using an isocratic mobile phase on a reverse phase C18 column. The lower limit of quantification was 100 ng/mL for both theophylline and etofylline with a relative standard deviation of less than 6%. A linear dynamic range of 100-10,000 ng/mL for both theophylline and etofylline was established. This HPLC method was validated with between-batch precision of 2.2-6.0 and 1.4-3.7% for theophylline and etofylline, respectively. The between-batch accuracy was 94.3-98.0 and 95.4-98.2%, respectively. Stability of theophylline and etofylline in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 30 days storage in a freezer. This validated method is simple and rugged enough to be used in pharmacokinetic studies.

Chromatography, High Pressure Liquid↗

Quantification of free and total sialic acid excretion by LC-MS/MS.

BACKGROUND: The main purpose for measuring urinary free sialic acid (FSA) is to diagnose sialic acid (SA) storage diseases. Elevated amounts of conjugated sialic acid (CSA) are observed in several diseases indicating the need to quantify CSA as well. A LC-MS/MS method for quantification of FSA and total sialic acid (TSA) in urine is developed and validated. METHODS: FSA is analyzed directly after filtration of urine samples. For determination of TSA an enzymatic (neuraminidase) and a chemical (acid) hydrolysis were compared. 13C3-sialic acid was used as internal standard. LC-MS/MS was performed in negative electrospray ionisation mode with multiple reaction monitoring of transitions m/z 308.2-->87.0 (SA) and m/z 311.2-->90.0 (13C3-SA). CSA was calculated by subtracting FSA from TSA. RESULTS: Limit of detection for FSA and TSA was 0.3 and 1.7 micromol/L, respectively. Limit of quantification for FSA and TSA was 1.0 and 5.0 micromol/L. Intra- and inter-assay variations of FSA were 4.6% and 6.6% (n=10) for FSA and 6.5% and 3.6% (n=10) for TSA. Linearity was tested till 7800 micromol/L (r2=0.9998). Values of SA analyzed after neuraminidase- or acid hydrolysis treatment were comparable. Urine samples from patients with inborn errors of SA (related) metabolism were analyzed and compared with age-related reference values. CONCLUSION: A method has been developed for routine determination of urinary FSA and TSA. The method is rapid, specific, robust and sensitive. Age-related reference values for FSA, TSA and CSA were determined and improved diagnostic efficacy.

Adolescent↗