At least 991 records · Page 55Linked to original sources

A disposable double-lumen tracheostomy tube--a prototype.

A prototype disposal double-lumen tracheostomy tube made of plastic has been developed and used successfully in two cases. It has definite advantages over a conventional double-lumen tube in facilitating suction and minimising the risk of kinking by virtue of its shorter length.

Disposable Equipment↗

Sport-specific performance factor profiling: fencing as a prototype.

A musculoskeletal profiling study was done on 24 members of the U. S. Pan American and Olympic fencing squads. This was presented as a methodological prototype for future, more comprehensive sport profiling studies. It is proposed that sport-specific profiling data have practical application in the following areas: 1. The identification of physical deficiencies in an athlete, using his or her sport profile as a comparative standard. This would apply to general pre- and postseason screening as well as to medical complaint-related examinations. 2. Providing objective, sport-specific criteria for determining when an injured athlete has recovered to the extent that he or she is adequately prepared to return to play. Rehabilitation goals for full recovery can also be defined. 3. Increasing the efficacy and efficiency of training techniques. 4. The prospective identification of superior performance potential in athletes at early competitive levels. If sport profiles were developed for the major participant sports at several competitive levels, the profiling system as described here could have significant application to a large number of athletes in a variety of playing situations.

Adult↗

Development of a hybrid (numerical-hydraulic) circulatory model: prototype testing and its response to IABP assistance.

Merging numerical and physical models of the circulation makes it possible to develop a new class of circulatory models defined as hybrid. This solution reduces the costs, enhances the flexibility and opens the way to many applications ranging from research to education and heart assist devices testing. In the prototype described in this paper, a hydraulic model of systemic arterial tree is connected to a lumped parameters numerical model including pulmonary circulation and the remaining parts of systemic circulation. The hydraulic model consists of a characteristic resistance, of a silicon rubber tube to allow the insertion of an Intra-Aortic Balloon Pump (IABP) and of a lumped parameters compliance. Two electro-hydraulic interfaces, realized by means of gear pumps driven by DC motors, connect the numerical section with both terminals of the hydraulic section. The lumped parameters numerical model and the control system (including analog to digital and digital to analog converters)are developed in LabVIEW environment. The behavior of the model is analyzed by means of the ventricular pressure-volume loops and the time courses of arterial and ventricular pressures and flows in different circulatory conditions. A simulated pathological condition was set to test the IABP and verify the response of the system to this type of mechanical circulatory assistance. The results show that the model can represent hemodynamic relationships in different ventricular and circulatory conditions and is able to react to the IABP assistance.

Analog-Digital Conversion↗

Conceptual models and integrative therapy: anorexia nervosa as a prototype.

OBJECTIVE: To demonstrate how an integrative approach to psychiatric treatment can confer specific advantages. METHOD: The impact of conceptual models on clinical information processing and therapeutic intervention, and the potential benefits resulting from the incorporation of multiple treatment modalities are outlined. These principles are applied using anorexia nervosa (AN) as a prototypical disorder. RESULTS: A brief, structured review of the broad range of models which have been applied to AN illustrates the impact of conceptualization on outcome. The opportunity for positive integrative effects in the treatment of AN are demonstrated. They are seen to be related to 6 factors: flexibility, patient-treatment matching, stage-treatment matching, facilitation, complementarity, and synergism. CONCLUSION: Integrative methods can address some limitations in clinical information processing associated with the exclusive application of a single conceptual model. Positive integrative effects are demonstrated in the context of AN; however, the approach is recommended for more general application.

Anorexia Nervosa↗

A preliminary evaluation of a prototype western blot confirmatory test kit for syphilis.

A prototype Western blot kit was evaluated as a confirmatory test for syphilis using 131 sera characterized by other serological tests for syphilis. There were 114 treponemal sera (including 94 cases of early syphilis, 83 of which were untreated) and 17 non-treponemal problem sera (11 gave false positive reactions on screening with the TmpA recombinant antigen enzyme immunoassay (EIA), 3 gave false positive fluorescent treponemal antibody absorbed (FTA-abs) tests, and 3 false positive Captia Syphilis G EIA results). Based on the manufacturer's criteria of reactivity in multiple bands for designating a positive result the Western blot test gave a sensitivity of 99.1% (113/114) and a specificity of 88.2% (15/17) when indeterminate reactions were scored positive and 98.2% (112/114) and 100% (17/17) when indeterminate reactions were scored negative. Sensitivity was high in both treated and untreated infection. Corresponding sensitivities for the TPHA and FTA-abs when equivocal reactions were scored negative were 97.5% (111/114) and 99.1% (113/114). The high sensitivity of the FTA-abs in this study is probably due to the large number of untreated primary infections. Our results with the Western blot, confirm earlier studies using 'in-house' test systems and, support a role for a commercial Western blot test in the confirmatory diagnosis of syphilis. Further studies are required to confirm the high specificity and sensitivity of the kit in a larger series including a wider variety of non-treponemal cases as well as patients with untreated and treated infection.

Blotting, Western↗

Angiotensin II receptor antagonists: the prototype losartan.

OBJECTIVE: To describe a new class of antihypertensive agents, the angiotensin II receptor antagonists, with emphasis on the prototype losartan. Pharmacokinetic data and clinical trials are reviewed, as well as adverse reactions, drug interactions, and dosing guidelines. DATA SOURCES: A MEDLINE search of English-language literature published from 1966 through 1995 was performed. In addition, Merck and Co. provided bibliographic data on file for losartan. STUDY SELECTION: Emphasis was placed on clinical and pharmacokinetic studies in humans. Controlled, double-blind studies were evaluated to assess the efficacy and adverse effect profile of losartan. DATA SYNTHESIS: Losartan is a nonpeptide, competitive antagonist of the type I angiotensin II receptor. In comparative clinical trials, losartan appears to have antihypertensive efficacy similar to that of the angiotensin-converting enzyme (ACE) inhibitors. Losartan is well tolerated, with an adverse effect profile similar to that of placebo and a reduced incidence of cough versus that with ACE inhibitors. A combination product consisting of losartan 50 mg and hydrochlorothiazide 12.5 mg has also received approval for the treatment of hypertension. The combination product is not indicated for initial therapy, but is recommended for patients who do not respond adequately to losartan monotherapy. The angiotensin II receptor antagonists are also being investigated for beneficial effects in patients with ventricular hypertrophy, renal disease, and heart failure. CONCLUSIONS: Losartan, the first angiotensin II receptor antagonist to receive approval for use in the US, appears to be an effective new antihypertensive agent with an adverse effect profile similar to that of placebo. Losartan may be an alternative for patients who cannot tolerate ACE inhibitors. However, the effect of losartan on mortality remains to be evaluated. The role of the angiotensin II receptor antagonists in areas such as ventricular hypertrophy, renal function, and heart failure has yet to be determined.

Angiotensin II↗

Rett syndrome: a prototypical neurodevelopmental disorder.

Rett syndrome, one of the leading causes of mental retardation and developmental regression in girls, is the first pervasive developmental disorder with a known genetic cause. The majority of cases of sporadic Rett syndrome are caused by mutations in the gene encoding methyl-CpG-binding protein 2 (MeCP2). MeCP2 binds methylated DNA and likely regulates gene expression and chromatin structure. Genotype/phenotype analysis revealed that the phenotypic spectrum of MECP2 mutations in humans is broader than initially suspected: Mutations have been discovered in Rett syndrome variants, mentally retarded males, and autistic children. A variety of in vivo and in vitro models has been developed that allow analysis of MeCP2 function and pathogenic studies of Rett syndrome. Because the neuropathology of Rett syndrome shares certain features with other neurodevelopmental disorders, a common pathogenic process may underlie these disorders. Thus, Rett syndrome is a prototype for the genetic, molecular, and neurobiological analysis of neurodevelopmental disorders.

Animals↗

Automatic speech recognition in vitreo-retinal surgery. A project for a prototypal computer-based voice-controlled vitrectomy machine.

In the past half decade automatic speech recognition techniques, software and hardware technology have matured enough to support sophisticated medical applications. The project described aimed at introducing a computer-based, voice-controlled prototype system in a simulated vitreo-retinal surgery scenario. The aim was to provide the surgeon with a tool that could significantly improve the quality and ease of work and shorten the duration of intervention. The speech recognition system allows voice entry of simple commands to simulate surgical instrument control, including the infusion pump, vitreous cutter and diathermy. The project relies on a Markov-based, speaker-dependent, commercial isolated-word recognizer, and consists of a specific recognition vocabulary and application software, created and developed by the authors. Results have been encouraging. The system performed well under the test conditions, proving robust, simple to use and accurate (over 97% average word recognition rate). On the basis of their experience, the authors believe that automatic speech recognition technology, though suffering from some limitations such as the need for training, speaker dependence and a relatively small vocabulary, and requiring extensive testing under operating conditions, merits further development and opens new perspectives for a possible new generation of surgical instruments.

Artificial Intelligence↗

A new prototype of an electronic jet-ventilator and its humidification system.

BACKGROUND: Adequate humidification in long-term jet ventilation is a critical aspect in terms of clinical safety. AIM: To assess a prototype of an electronic jet-ventilator and its humidification system. METHODS: Forty patients with respiratory insufficiency were randomly allocated to one of four groups. The criterion for inclusion in this study was respiratory insufficiency exhibiting a Murray score above 2. The four groups of patients were ventilated with three different respirators and four different humidification systems. Patients in groups A and B received superimposed high-frequency jet ventilation (SHFJV) by an electronic jet-ventilator either with (group A) or without (group B) an additional humidification system. Patients in group C received high-frequency percussive ventilation (HFPV) by a pneumatic high-frequency respirator, using a hot water humidifier for warming and moistening the inspiration gas. Patients in group D received conventional mechanical ventilation using a standard intensive care unit respirator with a standard humidification system. SHFJV and HFPV were used for a period of 100 h (4days). RESULTS: A significantly low inspiration gas temperature was noted in patients in group B, initially (27.2 +/- 2.5 degrees C) and after 2 days (28.0 +/- 1.6 degrees C) (P < 0.05). The percentage of relative humidity of the inspiration gas in patients in group B was also initially significantly low (69.8 +/- 4.1%; P < 0.05) but rose to an average of 98 +/- 2.8% after 2 h. The average percentage across all four groups amounted to 98 +/- 0.4% after 2 h. Inflammation of the tracheal mucosa was found in patients in group B and the mucosal injury score (MIS) was significantly higher than in all the other groups. Patients in groups A, C and D showed no severe evidence of airway damage, exhibiting adequate values of relative humidity and temperature of the inspired gas. CONCLUSION: The problems of humidification associated with jet ventilation can be fully prevented by using this new jet-ventilator. These data were sustained by nondeteriorating MIS values at the end of the 4-day study period in groups A, C and D.

Journal Article↗

A user-centered model for web site design: needs assessment, user interface design, and rapid prototyping.

As the Internet continues to grow as a delivery medium for health information, the design of effective Web sites becomes increasingly important. In this paper, the authors provide an overview of one effective model for Web site design, a user-centered process that includes techniques for needs assessment, goal/task analysis, user interface design, and rapid prototyping. They detail how this approach was employed to design a family health history Web site, Health Heritage . This Web site helps patients record and maintain their family health histories in a secure, confidential manner. It also supports primary care physicians through analysis of health histories, identification of potential risks, and provision of health care recommendations. Visual examples of the design process are provided to show how the use of this model resulted in an easy-to-use Web site that is likely to meet user needs. The model is effective across diverse content arenas and is appropriate for applications in varied media.

Family Health↗

The MMPI, prototypal typology, and borderline personality disorder.

This study demonstrates inherent features in the DSM-III diagnostic criteria for personality disorders (i.e., overlapping diagnoses and heterogeneous symptomatology) that limit efforts to identify a sensitive and specific MMPI profile for the borderline personality disorder. A sample of 71 inpatients was administered an MMPI and a semistructured interview that systematically evaluated each of 81 symptoms for the 11 DSM-III personality disorders. Interrater reliability was substantially higher than has been obtained with unstructured interviews. The effect on the borderline MMPI profile of variation in the number of borderline symptoms and overlap with the schizotypal, histrionic, and antisocial diagnoses was demonstrated. We discuss implications with respect to a prototypal model of classification.

Adult↗

Generalization of a prototype intelligent hybrid system for hard gelatin capsule formulation development.

The aim of this project was to expand a previously developed prototype expert network for use in the analysis of multiple biopharmaceutics classification system (BCS) class II drugs. The model drugs used were carbamazepine, chlorpropamide, diazepam, ibuprofen, ketoprofen, naproxen, and piroxicam. Recommended formulations were manufactured and tested for dissolution performance. A comprehensive training data set for the model drugs was developed and used to retrain the artificial neural network. The training and the system were validated based on the comparison of predicted and observed performance of the recommended formulations. The initial test of the system resulted in high error values, indicating poor prediction capabilities for drugs other than piroxicam. A new data set, containing 182 batches, was used for retraining. Ten percent of the test batches were used for cross-validation, resulting in models with R2 > or = 70%. The comparison of observed performance to the predicted performance found that the system predicted successfully. The hybrid network was generally able to predict the amount of drug dissolved within 5% for the model drugs. Through validation, the system was proven to be capable of designing formulations that met specific drug performance criteria. By including parameters to address wettability and the intrinsic dissolution characteristics of the drugs, the hybrid system was shown to be suitable for analysis of multiple BCS class II drugs.

Artificial Intelligence↗

Conservation of the hydroxysteroid sulfotransferase SULT2B1 gene structure in the mouse: pre- and postnatal expression, kinetic analysis of isoforms, and comparison with prototypical SULT2A1.

A novel mouse hydroxysteroid sulfotransferase cDNA has been cloned, and organization of its gene structure has been determined. The new mouse sulfotransferase, SULT2B1a, and its closely related isoform, SULT2B1b, are derived from a single SULT2B1 gene as a result of an alternative exon I and differential splicing. Thus, the only structural distinction between the two SULT2B1 isoforms is at their amino-terminal ends. Importantly, in contrast to the prototypical mouse hydroxysteroid sulfotransferase SULT2A1, the SULT2B1 isoforms have a predilection for cholesterol. Real-time RT-PCR reveals that the SULT2B1a isoform is most abundantly expressed in the brain and spinal cord, whereas SULT2B1b and SULT2A1 are weakly, if at all, expressed in the central nervous system. On the other hand, the SULT2B1b isoform is the most prominent hydroxysteroid sulfotransferase expressed in skin, whereas SULT2A1 is strikingly expressed in the liver. The substrate specificities and differential expression patterns of the three SULT2 isozymes strongly suggest that they have distinct biologic roles to play. Of further interest, the mouse SULT2B1 and SULT2A1 genes are differentially expressed during embryonic development, with the former being expressed at all stages from E8.5-E19, whereas the latter is not expressed until E19. It is speculated that, during embryonic development, SULT2B1b is required for production of cholesterol sulfate essential for normal skin development, whereas SULT2B1a produces pregnenolone sulfate, an essential neurosteroid during development of the central nervous system.

Amino Acid Sequence↗

An evaluation of a vibro-tactile display prototype for physiological monitoring.

Visual displays and auditory alarms are used to convey information on physiological variables in an operating room. However, the exponential growth in the number of physiological variables and the high probability of false alarms has amplified demands on the clinician's attention. We have extended existing tactile technology to improve situational awareness and produce a practical clinical advisory device. A vibro-tactile display, using two vibrating motors applied to the volar surface of the forearm, was compared to an auditory alarm in a simulated clinical environment. Compared with auditory alarms, the vibro-tactile alarm was as easy to learn and had a better identification rate when used alone or combined with the auditory alarm. Most users preferred the vibro-tactile alarm although the prototype caused some discomfort. Furthermore, a combined vibro-tactile and auditory alarm had reduced accuracy when compared with the vibro-tactile alarm alone. The vibro-tactile modality shows considerable promise for clinical practice but will require further clinical testing and refinement, especially with regard to user comfort.

Anesthesiology↗

The computer-aided design and rapid prototyping fabrication of removable partial denture frameworks.

This study explores the application of computer-aided design and manufacture (CAD/CAM) to the process of electronically surveying a scanned dental cast as a prior stage to producing a sacrificial pattern for a removable partial denture (RPD) metal alloy framework. These are designed to retain artificial replacement teeth in the oral cavity. A cast produced from an impression of a patient's mouth was digitally scanned and the data converted to a three-dimensional computer file that could be read by the computer-aided design (CAD) software. Analysis and preparation were carried out in the digital environment according to established dental principles. The CAD software was then used to design the framework and generate a standard triangulation language (STL) file in preparation for its manufacture using rapid prototyping (RP) methods. Several RP methods were subsequently used to produce sacrificial patterns, which were then cast in a chromium-cobalt alloy using conventional methods and assessed for accuracy of fit. This work demonstrates that CAD/CAM techniques can be used for electronic dental cast analysis, preparation, and design of RPD frameworks. It also demonstrates that RP-produced patterns may be successfully cast using conventional methods and that the resulting frameworks can provide a satisfactory fit.

Computer-Aided Design↗

Rapid prototyping for orthopaedic surgery.

The revision of an orthopaedic procedure can present surgeons with the challenge of a complex reconstructive process. Orthopaedic surgery can also face considerable challenges in cases presenting extensive primary injuries with multiple bone fragmentation, as well as in cases presenting bone deformities. Radiographs are used routinely for orthopaedic surgical planning, yet they provide inadequate information on the precise three-dimensional extent of bone defects. Three-dimensional reconstructions from X-ray computed tomography offer superior visualization but are not portable for consultation or readily available in the operating theatre for guidance during a procedure. A physical model manufactured from X-ray computed tomography data can offer surgeons a clear understanding of complex anatomical detail, by providing an intuitive physical relationship between patient and model. Rapid prototyping was used for the construction of an anatomical model in a case presenting with a complex shoulder injury. The model provided a definitive interpretation of joint pathology and enabled a full assessment of the degree of injury.

Adult↗

A prototype model for renal vasculature and its application in haemodialyser miniaturization.

At present, little information and few models are available to describe either renal haemodynamics or the structure of the kidney. By modelling renal haemodynamics, more information about flow behaviour and efficiency can be obtained, thus leading to the modelling of the human kidney and enabling comparisons with dialysis haemodynamics to be made. This paper examines a prototype model of renal vasculature and remarks upon comparisons drawn from data from human kidneys, as an introduction to those interested in replicating the functions of the kidney by using a miniature haemodialyser.

Equipment Design↗

Trial fitting of a removable partial denture framework made using computer-aided design and rapid prototyping techniques.

Previous studies of CAD/CAM-produced sacrificial patterns for removable partial denture frameworks have been documented but to date, no such restorations have been test-fitted to a patient. This paper provides details of the first trial fitting to a patient of an RPD framework, the sacrificial pattern of which was produced by CAD/CAM and RP technologies. A cast of the patient was scanned and the normal procedures of dental surveying and pattern build were undertaken with reference to the scanned model using computer-aided design. A sacrificial pattern of the design was produced by rapid prototyping technology. After spruing the pattern, investment-casting and finishing techniques were carried out according to conventional principles. The framework was successfully trial-fitted to the patient and clinically judged to be acceptable for the next stage of denture fabrication, that of adding acrylic bases and artificial teeth.

Computer-Aided Design↗