Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “artifacts”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

Overestimation of NADH-driven vascular oxidase activity due to lucigenin artifacts.

Several limitations have recently been described for lucigenin, a probe frequently used to assess the activity of vascular NAD(P)H oxidase, a major superoxide source. The preferential reducing substrate of such oxidase remains unclear. We assessed whether lucigenin artifacts could affect detection of NAD(P)H oxidase activity. Initial chemiluminescence assays were performed with vascular rings or homogenates at 5, 50, or 250 microM concentrations. Results showed preferential signals with NADPH (vs. NADH) with 5 and 50 microM lucigenin, which were blocked by diphenylene iodonium (DPI), superoxide dismutase (SOD), or its cell-permeable mimetic MnTBAP. With 250 microM lucigenin, the relative signal with NADH became larger than with NADPH, and was poorly inhibited by all three antagonists above. All SOD/DPI-resistant signals were effectively blocked by the electron acceptor nitrobluetetrazolium. Spin trapping with DMPO showed an approximate doubling of DMPO-OH radical adduct signal upon addition of 5 microM lucigenin to homogenates incubated with either NADPH or NADH. With 50 or 250 microM lucigenin, much larger increases were observed with NADH, as opposed to NADPH. Furthermore, oxygen consumption measurements showed analogous results. In summary, our data suggest that: (i) Lucigenin redox-cycling is detectable in vascular tissue even at 5 microM concentrations, while at 250 microM redox-cycling becomes predominant and is markedly increased when NADH is the assayed substrate; and (ii) With 250 microM lucigenin, preferentially with NADH, signals are further overestimated by direct, oxidase-dependent, superoxide-independent two-electron transfer. Therefore, previous reports of preferential NADH affinity of the vascular oxidase may have been due to these artifacts.

Acridines↗

Another face of mirror-image artifact.

The physics of ultrasound and mechanisms of artifacts are well-known. In this report, an unusual manifestation of mirror-image artifact (MIA) that is completely different from the real image of the structure, demonstrated during a routine abdominal ultrasonographic examination, is described. There have hitherto been no reports on the ultrasonographic appearance of such a MIA.

Artifacts↗

Identification and resolution of artifacts in bisulfite sequencing.

Bisulfite sequencing has become the most widely used application to detect 5-methylcytosine (5-MeC) in DNA, and provides a reliable way of detecting any methylated cytosine at single-molecule resolution in any sequence context. The process of bisulfite treatment exploits the different sensitivity of cytosine and 5-MeC to deamination by bisulfite under acidic conditions, in which cytosine undergoes conversion to uracil while 5-MeC remains unreactive. In this article, we address the more commonly encountered experimental artifacts associated with bisulfite sequencing, and provide methods for the detection and elimination of these artifacts. In particular, we focus on conditions that inhibit complete bisulfite-mediated conversion of cytosines in a target sequence, and demonstrate the necessity of complete protein removal from DNA samples prior to bisulfite treatment. We also include a brief summary of the experimental protocol for bisulfite treatment and tips for designing polymerase chain reaction (PCR) primers to amplify from bisulfite-treated DNA.

5-Methylcytosine↗

Experimental study of the sampling artifact of chloride depletion from collected sea salt aerosols.

Sampling artifact of chloride depletion from collected sea salt particles was studied, based on simultaneous measurements of size distribution measurements by a 10-stage Micro-Orifice Uniform Deposit Impactor (MOUDI) and of PM2.5 measurements by a Compact Porous Metal Denuder Sampler (PMDS) at a coastal site in Hong Kong on May 7, 8, 9, 11, and 29, 1998. The ambient concentrations of SO2, HNO3, HNO2, and NH3 were also measured by the PMDS. PM2.5 measurements by the PMDS, which is equipped with denuders and nylon back filters, are compared with the PM1.8 and PM3.1 measurements by the MOUDI. The percentages of chloride depletion from sea salt aerosols in PM1.8 and PM3.1 were 4-45% higher than that in PM2.5. This suggests that chloride evaporation in PM1.8 and PM3.1 collected on Teflon filters of the MOUDI during sampling was present. From the sum of the contributions of particles on the Teflon and nylon filters of the PMDS, nitrate formation almost completely accounts for chloride depletion in PM2.5 prior to collection since the equivalent ratio of [Na+] to ([NO3-] + [Cl-]) is close to the seawater ratio of 0.85. However, it was found that 22-74% of nitrate and 45-86% of chloride in the collected particles on the Teflon filter of the PMDS evaporated during sampling. Excess chloride depletion unexplained by NO3- and nss-SO4(2-) was found in the collected particles on the Teflon filter of the PMDS. Similarly, an amount of 3.7-27.2 nequiv m-3 of excess depleted chloride (equivalent to 8-55% of total chloride depletion) was found in supermicron particles collected by the MOUDI. In the 1.8-3.1 microns particles, the excess depleted chloride is positively correlated to the chloride evaporated from the deposited particles. Particle--particle interactions are proposed to explain the evaporation of nitrates and chlorides in the PMDS and MOUDI measurements. The observed chloride depletion from seasalt aerosols was partially attributed to sampling artifact due to particle--particle interactions.

Aerosols↗

Filtration artifacts caused by overloading membrane filters.

The conventional practice of using 0.45 or 0.40 microm membranes to distinguish between the particulate and dissolved phases in natural waters neglects the importance of colloids. Many of the colloids in natural waters pass through 0.45 or 0.40 microm membranes, but a significant fraction at the upper end of the colloidal particle size range is retained. Membrane clogging during filtration decreases the effective pore size and can cause the retention of increasing amounts of colloids. This filtration artifact can cause serious errors in sampling and in assigning trace metals to various particle size classes. We evaluated the effect of membrane loading for two common membrane types (0.45 microm Millipore Durapore and 0.40 microm Nuclepore) on the retention of colloidal Fe, Al, Mn, and OM in three Connecticut rivers. In addition, we used a 1.0 microm Nuclepore membrane to estimate the amount of colloids in the 0.40-1.0 microm size fraction that are retained by membranes during conventional filtration. All samples were collected with clean techniques, and all filtrations were carried out in a class 100 clean room. A peristaltic pump, set at an initial flow rate of 120 mL/min, was used to pump samples through 47 mm diameter inline Teflon filter holders. Back pressure and flow rate were monitored during filtration, and both are good indicators for the onset of membrane clogging. The results show a consistent correlation between increasing back pressure and decreasing concentration of colloidal Fe and sometimes Al, Mn, and OM in the filtrate for all membrane types. Although the shape of the loading-retention curves varied dramatically by site and by membrane type, the essential relationship between back pressure, flow rate, and filtration artifacts during membrane clogging remained the same.

Artifacts↗

Electrostatic sampler for semivolatile aerosols: chemical artifacts.

Electrostatic precipitators (ESPs) show promise as an alternative sampling method for semivolatile aerosols because they are less susceptible to adsorptive and evaporative artifacts than filter based methods. However, the corona discharge may after the chemical composition of a sampled aerosol. Chemical artifacts associated with electrostatic precipitation of semivolatile aerosols were investigated in the laboratory. ESPs and filters sampled both particles and vapors of alkanes, polycyclic aromatic hydrocarbons, and alkenes across varying concentrations. Gravimetric measurements between the two sampling methods were well correlated. Ozone generated by the ESP corona was the primary cause of alkene reactions in the gas phase. Particles collected within the corona region were vulnerable to irradiation by corona ions overtime. Particles collected outside the corona region did not react. Vapors passing through the corona reacted to a lesser extent. Vapors captured after passing through the ESP reacted with ozone that was not removed by the vapor trap. Chemical speciation of highly reactive compounds (i.e., alkenes or other compounds with relatively short half-lives outdoors) is not appropriate with ESPs. Electrostatic precipitation of these compounds is appropriate, however, when total organic carbon is of interest as the ESP does not alter the amount of mass measured gravimetrically. ESPs can make accurate measurements of more persistent semivolatile compounds, such as alkanes and PAHs.

Aerosols↗

Stability of saponins in alcoholic solutions: ester formation as artifacts.

Saponins containing a free carboxylic group in the molecule give the corresponding esters as artifacts when stored for a long time in alcoholic solutions. Two saponins from Medicago sativa L., chosen on the basis of their different positions of the carboxylic group in the molecule, were refluxed with methanol and ethanol under neutral conditions. 3,28-di-O-glu medicagenic acid possesses a carboxylic group on the triterpenic moiety, whereas soyasaponin I, a glycoside of soyasapogenol B, has a glucuronic acid unit as the first sugar linked to the triterpene structure. Artifacts were quantified by HPLC. The peaks identified as the corresponding esters were examined during boiling from 1 h to 5 days. Quantitative results indicated that the carboxylic group on the sugar moiety, as for soyasaponin I, is more reactive than that on the triterpenic structure, as for 3,28-di-O-glu medicagenic acid. Saponins having the free carboxylic groups create enough acidity in their alcoholic solutions to catalyze the formation of the corresponding esters.

Artifacts↗

Recording of pacing stimulus artifacts by endovascular defibrillation lead systems: comparison of true and integrated bipolar circuits.

BACKGROUND: The occurrence ICD undersensing of ventricular fibrillation due to the presence of a pacing stimulus artifact (PSA) is in part related to the amplitude of the artifact recorded on the ICD rate sensing circuit. There is little comparative data regarding PSA amplitude recorded by commercial ICD rate-sensing circuits. PURPOSE: To compare PSA amplitude recorded by commercial endovascular defibrillation leads utilizing integrated or true bipolar sensing circuits. METHODS: Nineteen large (60-120 kg) pigs were utilized. Two different commercial endovascular defibrillation leads were evaluated, each with its distal tip located at the right ventricular apex: (1) Medtronic Transvene; and (2) CPI Endotak. Three different rate-sensing circuits were evaluated: (1) Transvene true bipolar (tip-ring); (2) Transvene integrated bipolar (tip-coil); and (3) Endotak integrated bipolar (tip-coil). Using a separate pacing lead located at the left ventricular apex (n = 19 animals) or right ventricular outflow tract (n = 10 animals), pacing was performed at a pulse width of 0.5 milliseconds at outputs of 1.5, 5 and 10 volts. PSA amplitude was recorded at each output by each circuit. RESULTS: During pacing from the left ventricular apex, at each pacing output voltage the PSA amplitude recorded by the true bipolar circuit (0.6 +/- 0.1 mV at 1.5 volts, 2.0 +/- 0.5 mV at 5 volts, 3.7 +/- 0.8 mV at 10 volts) was significantly smaller than recorded by the Transvene integrated circuit (1.4 +/- 0.3 mV at 1.5 volts, 3.8 +/- 0.7 mV at 5 volts, 4.1 +/- 0.8 mV at 10 volts) or the Endotak integrated circuit (1.8 +/- 0.4 mV at 1.5 volts, 4.2 +/- 1.0 mV at 5 volts, 6.3 +/- 1.8 mV at 10 volts). During pacing from the right ventricular outflow tract, at each pacing output voltage the PSA amplitude recorded by the true bipolar circuit (0.7 +/- 0.1 mV at 1.5 volts, 1.7 +/- 0.4 mV at 5 volts, 4.0 +/- 0.7 mV at 10 volts) was significantly smaller than recorded by the Transvene integrated circuit (1.1 +/- 0.4 mV at 1.5 volts, 3.9 +/- 1.2 mV at 5 volts, 7.5 +/- 1.8 mV at 10 volts) or the Endotak integrated circuit (1.6 +/- 0.7 mV at 1.5 volts, 4.3 +/- 1.7 mV at 5 volts, 7.5 +/- 2.6 mV at 10 volts). For both pacing sites, the PSA amplitude recorded by the two integrated circuits was not significantly different. CONCLUSIONS: For a given pacing output voltage, PSA amplitude recorded by commercial endovascular rate sensing/defibrillation leads is greater when the sensing circuit is integrated than when it is true bipolar. These data may be helpful in planning ICD implantation in patients with previously implanted permanent pacemakers.

Animals↗

Artifact mistaken for electrical interference recorded from a pulmonary artery catheter.

Artifactual signals superimposed on the electrocardiogram have been well documented [1-5]. These signals can originate from infusion pumps [1, 2], occlusion heads from cardiopulmonary bypass machines [3,4], and dialysis apparatus [5]. Artifacts on a pulmonary artery tracing, such as those produced by "catheter whip," are well described [6], and rarely if ever confuse the clinician. Extraneous electrical signals are of major concern because they pose a hazard to susceptible patients. We report a case in which the blood pressure tracing from the pulmonary artery revealed an artifact that looked at first glance like 60 cycle alternating current (AC) electrical interference. The investigation as to its origin revealed important lessons in the analysis of human error.

Artifacts↗

Optically clear nuclei in papillary carcinoma of the thyroid: demonstration of one of the fixation artifacts and its practical usefulness.

To examine whether or not optically clear nuclei are one of the fixation artifacts in papillary carcinoma of the thyroid. Experiments using an optimal immersion fixation method by making thin-sliced specimens, 5 x 2 x 2 mm in size were adopted. Fixatives tested were 10% formalin, 10% buffered formalin, mixture of alcohol and formalin (4: 1), 95% alcohol, 4% phosphate-buffered paraformaldehyde, Carnoy's fixative, Bouin's fixative and various concentrations of formalin. Tested thyroid lesions in total were: cases with papillary carcinoma (38); follicular carcinoma (one); follicular adenoma (15); adenomatous goiter (11); Hashimoto's thyroiditis (two); Grave's disease (five); and normal thyroid tissue around tumor (five). Routinely processed papillary carcinoma showed a high occurrence (64.6%) of the optically clear nuclei contrasted by a low occurrence (almost 0%) in other lesions. However, this rate in papillary carcinoma decreased (< 35.3%) in all experimental groups irrespective of the choice of fixatives. Frequent occurrence (61.9-66.6%) of the optically clear nuclei was reproduced in papillary carcinoma fixed in a higher concentration of formalin (40-60%) in the experimental groups. These results demonstrated that the optically clear nuclei are one of the fixation artifacts, although still useful as a diagnostic criterion.

Adenocarcinoma, Follicular↗

Doppler mirror image artifacts mimicking mitral regurgitation in patients with mechanical bileaflet mitral valve prostheses.

AIMS: To characterize the origin and mechanisms of generation of Doppler mirror images in the left atrium observed in patients with mechanical bileaflet mitral valve prosthesis. We hypothesized that these systolic colour Doppler images are artifactual and generated by reflection of the left ventricular outflow tract flow at the leaflet of the mitral valve prosthesis. METHODS AND RESULTS: Fifty patients with mechanical bileaflet mitral valves were prospectively examined by means of transthoracic Doppler-echocardiography. From different apical views, the left atrium was carefully interrogated for systolic colour flow signals, which were further analysed by pulsed wave Doppler. In all patients, a systolic colour Doppler signal was detected in the left atrium. Pulsed wave Doppler analysis revealed a low velocity signal (= mirror image) corresponding to the shape and duration of the left ventricular outflow tract signal. The peak velocities of these mirror images, however, were consistently lower than the velocities obtained from the left ventricular outflow tract. In addition, if paravalvular mitral valve leakage was present, a high velocity signal identical to the duration of mitral regurgitation time was detected outside the ring of the prosthesis. CONCLUSIONS: Mirror image artifacts mimicking mitral regurgitation occur in patients with mechanical mitral valves prosthesis. As mirror image artifacts can be specifically identified by analysis of shape. velocity, and duration of pulsed wave Doppler spectra, their identification will help to avoid misinterpretation of both spectral and colour Doppler signals in patients with prosthetic mitral valves.

Aged↗

Pitfalls and artifacts in 18FDG PET and PET/CT oncologic imaging.

It is estimated that in excess of one million positron emission tomography (PET) scans are performed each year and PET can now truly be regarded as a routine imaging procedure in clinical management. Many potential pitfalls and artifacts have previously been described with (18)F-fluorodeoxyglucose PET imaging, but more continue to become apparent as worldwide experience increases. In addition, the advent of combined PET/CT scanners in clinical imaging practice has brought their own specific pitfalls and artifacts. It is essential that we learn these potential pitfalls so that patients can be optimally prepared for their scans and that accurate interpretation can be made.

Artifacts↗

[The influence of motion artifacts conditioned by reconstruction, on the coronary calcium score in multislice spiral CT].

UNLABELLED: The influence of motion artifacts conditioned by reconstruction, on the coronary calcium score in multislice spiral CT. PURPOSE: A major problem of the quantification of coronary calcifications is a high variability of the coronary calcium score between recurrent examinations and different observers. Aim of our study is to evaluate the influence of different RR-intervals on the coronary calcium score utilizing retrospectively gated Multislice Spiral CT (MSCT) data sets. MATERIALS AND METHOD: 50 consecutive patients underwent MSCT examination (Somatom Volume Zoom, Siemens, Forchheim, G) utilizing a standardized scan protocol (4 x 2.5 mm collimation, 3 mm increment, tube current 133 mAs, tube voltage 120 kV). Retrospectively gated image reconstruction was performed every 10 % of the RR interval. Coronary calcification was evaluated by the Agatston score. Coronary risk assessment was performed in all patients with image reconstruction beginning at 80 % of the RR interval. The reconstruction intervals with the least motion artifacts were identified and chosen as reference for a reevaluation of the coronary risk. The results of different reconstruction times were compared. RESULTS: The mean calcium score was 551.6. The calcium score varied between 512.2 (90 %) and 571.7 (70 %), depending on the image reconstruction interval. Compared to the mean calcium score a new classification of the coronary risk was necessary in 7/50 of the patients at 80 % reconstruction interval, and in 2/50 of the patients at 50 % of the RR interval, respectively. CONCLUSION: Movement of the coronary arteries at different image reconstruction intervals has an important influence on the coronary calcium score. Based on our data, we propose image reconstruction at 50 % of the RR interval for evaluation of the coronary calcium score by MSCT.

Adult↗

[Systematics of imaging artifacts in MRT caused by metallic vascular implants (stents)].

PURPOSE: Imaging artifacts in magnetic resonance tomography (MRT) caused by metallic vascular implants (stents) were characterized systematically in dependence on the material and the construction of the implants as well as with respect to different measurement protocols and for different static field strength B (0). METHODS: Twelve stents, different in material (stainless steel, nitinol, Co-alloy) and/or construction, were examined at B (0) = 0.2 T and 1.0 T with two 2D gradient echo (GE) sequences (TE = 4 and 10 ms), one 3D GE sequence and one spin echo (SE) sequence. The stents were put into water with Gd-DTPA contrast agent. The dependence on the orientation was analyzed for the 9 possibilities of an orthogonal alignment of the stent axis, the direction of B (0), the slice, the read out, and the phase encoding direction. Special interest was given to the visibility of the stent lumen at forced rf excitation, as well as to the influence of broken struts on the signal obtained. RESULTS: For the examined stents GE technique showed, due to spin dephasing regions a total signal loss ranging up to 8 mm away from the stent mashes. The value depends on the stent material, the stent orientation in the scanner and grows with voxel size, echo time and B (0). In SE technique dephasing artifacts vanish and wrong spatial encoding gets visible, rf shielding is more pronounced. The visibility of the stent lumen ranges from nearly unperturbed down to a complete signal loss. An improvement is possible using enlarged flip angles. Broken struts can not be imaged significantly. DISCUSSION: The MR representation of metallic stents commercially available at the time, especially of nitionol stents, can be optimized with a suitable adaptation of the imaging parameters. However, a profound improvement can only be expected from new stent material and design.

Alloys↗

[Artifacts in MRT caused by instruments and implants].

Metallic instruments and implants can cause severe image artifacts in magnetic resonance imaging (MRI). Besides the properties of the materials and the geometrical arrangement of the devices, the applied MRI sequence type and its parameters (echo time, voxel size, read-out bandwidth, orientations of encoding directions, etc.) play also an important role. These interactions are presented in a systematic survey. A detailed description of the basic physical mechanisms underlying the generation of artifacts is also provided.

Artifacts↗

Immunohistochemical artifact for nitrotyrosine in eosinophils or eosinophil containing tissue.

Immunohistochemical artifacts for nitrotyrosine were investigated in eosinophils with regard to fixatives. Immunoreactivity for nitrotyrosine was revealed in separated eosinophils and in gastric mucosa fixed with periodate, lysine-paraformaldehyde (PLP). The increase in immunoreactivity by PLP was due to periodate itself, a component of PLP. Nitrotyrosine formed by peroxidase using NO2- and H2O2 or by peroxynitrite was not completely inhibited by 100 mM dithionite but the immunoreactivity for nitrotyrosine antibodies by PLP was completely inhibited by 5.7 mM dithionite. Although untreated eosinophils or ovalbumin (OVA) did not show protein tyrosine nitration in a standard Western blot, the treatment of the blotted membrane with PLP increased the reactivities of proteins from eosinophils with anti-nitrotyrosine antibodies. The increase in immunoreactivity of OVA with anti-nitrotyrosine antibodies by PLP did not change with pre-treatment with dithionite but was abolished by treatment with dithionite after PLP fixation. In HPLC assays, periodate did not generate nitrotyrosine from L-tyrosine and aminotyrosine. These results suggest that the treatment of eosinophils or eosinophil-containing tissues with PLP fixative augments the immunoreactivity of nitrotyrosine antibodies with eosinophils due to the formation of epitopes similar to nitrotyrosine by an oxidation reaction of periodate, which evokes an artifact in nitrotyrosine immunohistochemistry.

Artifacts↗

On artifacts appearing in the histochemical fixation of glycogen.

1. Fixation artifacts associated with glycogen translocation are prevalent in tissues of parenchymatous type and scarce or non-existent in tissues of loose type. 2. Liver tissue treated with M/3 NaOH solution before fixation did not show an uneven distribution of glycogen. This was interpreted as indicating that the liver, a tissue of parenchymatous type, was changed, so to speak, into a loose type of tissue by alkali treatment. 3. The so called Alkohol-flucht of glycogen was produced in Yoshida's ascites tumor cells by a procedure which changed a loose type of tissue into a parenchymatous one, that is, by packing the tumor cells tightly. 4. The translocation of glycogen in cells appeared to occur when the fixatives penetrated the cells rapidly from a single direction, but failed to occur when the cells were attacked by the fixative from all directions. 5. In dried smears of Yoshida's ascites tumor cells and bone marrow cells, the glycogen particles are translocated to the peripheral regions of the cells, and coalesce there. The production of these artifacts is related in some way to the physicochemical properties of the protoplasm and plasma membrane of the cells.

Artifacts↗