Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Sound”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

Temporal encoding for auditory computation: physiology of primary afferent neurons in sound-producing fish.

Many fish rely on sounds for communication, yet the peripheral structures containing the hair cells are simple, without the morphological specializations that facilitate frequency analysis in the mammalian cochlea. Despite this, neurons in the midbrain of sound-producing fish (Pollimyrus) have complex receptive fields, extracting features from courtship sounds. Here we present an analysis of the initial encoding of sounds by the primary afferents and demonstrate that the representation of sound undergoes a substantial transformation as it ascends to the midbrain. Afferents were isolated as they coursed from the sacculus through the medulla. Tones (100 Hz-1.2 kHz) elicited synchronized spikes [vector strength (VS) >0.9] on each stimulus cycle [coefficient of variation (CV) <1.1], with little spike rate adaptation. Most afferents (67%) were spontaneously active and began synchronizing 10 dB below rate threshold. Rate thresholds for the most sensitive afferents (65 dB) were close to behavioral thresholds. The distribution of characteristic frequencies and best sensitivities was matched to the spectrum of sounds of this species and to its audiogram. Three clusters of afferents were identified, one including afferents that generated spike bursts and had v-shaped response areas (bursters), and two others that included entrained afferents with broad response areas (entrained types I and II). All afferents encoded the timing of clicks within click trains with time-locked spikes, and none showed selectivity for interclick intervals. Understanding the computations that yield complex receptive fields is an essential goal for auditory neuroscience, and these data on primary encoding advance this goal, allowing a comparison of inputs with feature-extracting midbrain neurons.

Acoustic Stimulation↗

Accuracy and reliability of 'specialized' physical therapists in auscultating tape-recorded lung sounds.

This study investigated the accuracy and inter-rater reliability of 'specialized' physical therapists in the auscultation of tape-recorded lung sounds. In addition, a correlation was investigated between accuracy of interpretation and the number of years of specialization in the field of cardiorespiratory physical therapy. This research follows an earlier study which investigated the accuracy and inter-rater reliability of auscultating tape-recorded lung sounds in a 'non-specialized' cohort of physical therapists. The subjects were 26 'specialized' cardiorespiratory physical therapists working in acute urban teaching hospitals. These individuals were required to have been practising currently and exclusively for at least one year in the area of cardiorespiratory physical therapy. Participants listened with a stethoscope to five different sounds and identified them from a standardized list of terms. One of three tapes with the same lung sounds in different order was randomly selected for each physical therapist. The percentage of correct answers for all subjects was calculated. An accurate response in the detection of lung sounds was arbitrarily defined as a percentage of correct answers of 70% or greater. The difference between the pooled correct response rate of 50% and the arbitrarily set value of 70% was statistically significant (z = 2.23, p < 0.05), indicating that the 'specialized' physical therapists were not accurate in identifying lung sounds. There was no relationship evident between the accuracy and the number of years of cardiorespiratory 'specialization' (r = 0.08). Analysis of inter-rater reliability revealed 'fair agreement' (kappa = 0.26) among subjects. These results were similar to those found in the previous study.(ABSTRACT TRUNCATED AT 250 WORDS)

Auscultation↗

The influence of sound stimulation during hatching on the mortality of ducks.

In the work the influence of the artificial sound stimulation during incubation on the speed of the Pekin duck breed hatching as well as on their mortality during that period was observed. The set eggs were hatched in four hatcheries. The eggs of the first two hatcheries (control groups Ka and Kb) were not sound stimulated. In the other two groups the set eggs were, from the very first hour of hatching, stimulated by the "knocking" sound from an electronic sound generator (experimental groups "a" and "b"). For the stimulation, the acoustic signal with intensity of 25 dB and frequency 5.68 Hz was applied. The fastest hatching process was recorded in the groups with sound stimulation. The "a" experimental group was the fastest, the ducks were hatched after 640.75+/-10.15 hours, in the "b" experimental group the ducks were hatched after 656.50+/-1.70 hours of incubation. In both sound stimulated experimental groups (a, b) the increased embryonic mortality resulted in the decrease of the percentage of hatchability--to 68.09+/-1.77% and 76.44+/-2.68%, respectively. This is statistically evident (P<0.01) when compared with the respective control groups which reached the 88.81+/-1.86% and 89.35+/-0.81% hatchability.

Acoustic Stimulation↗

Teaching cardiac auscultation using simulated heart sounds and small-group discussion.

BACKGROUND AND OBJECTIVES: Several educators have reported poor identification of abnormal cardiac sounds by primary care residents. Practice and review with cardiology patient simulators and prerecorded heart sounds has been shown to increase the accuracy of diagnosis by medical students and residents. METHODS: The participants were 15 members of an urban family practice residency. The residents were presented with simulated heart sounds and were asked to identify them in a pretest and posttest. Between the tests, participants were invited to three separate teaching sessions that involved a discussion of cardiac auscultatory findings and a review of audiotaped similar heart sounds. Residents who were unable to attend the teaching sessions formed a control group. RESULTS: The pretest identification rate was 36% for the heart sounds. This improved to 62% for all residents after the intervention. Higher rates of improvement were demonstrated by the residents who attended one or more teaching sessions, compared with the residents who attended no teaching sessions. CONCLUSIONS: Small-group discussion and repetitive auscultation of simulated heart sounds can improve the cardiac auscultatory proficiency of family practice residents.

Education, Medical, Undergraduate↗

The intrusiveness of sound: Laboratory findings and their implications for noise abatement.

Environmental policy with regard to noise abatement has traditionally only considered whether the noise levels in a given setting are high enough to be deemed a source of annoyance, disturbance, or threat to well being. However, laboratory studies using both simple and more complex work-related tasks have shown that task-irrelevant sound, regardless of its intensity, intrudes upon cognitive processing and disrupts performance substantially; furthermore, its damaging effect does not diminish with repeated exposure to the sound over time. For tasks that require short-term memory processing (particularly the short-term maintenance of order information) sound assumes disruptive power if it is acoustically varying over its time course. However, other properties of sound (e.g., the semanticity of speech) can incur an additional cost if the primary task necessitates or tends to evoke the extraction of meaning. It will be argued that interference in each case is explained by reference to a conflict between two concurrent mental processes; that being demanded by the task and that being involuntarily applied to properties of the sound. Such harmful effects, as well as having direct consequences for the general well-being of those working in noisy environments, may have far reaching consequences for health insofar as extraneous sound is a feature of many safety-critical work settings. Implications for noise abatement policy are highlighted.

Journal Article↗

Disturbing effects of low frequency sound immissions and vibrations in residential buildings.

Noise immissions with predominant low frequency sound components may exert considerably disturbing effects in dwellings. This applies in particular to sounds which are excitated by transmission of structure-borne noise, and to low frequency sounds emitted by ventilators. Exposed persons usually declare such immissions as being "intolerable" even at very low A-weighted sound levels. If mechanical vibrations in the frequency range below 20 Hz (ground-borne vibrations) affect dwelling rooms, the annoying effects are perceived only by a small portion of exposed individuals as a physical effect. For the most part the immissions are observed as vibratory effects on the building and on objects inside the dwelling. The disturbing effects of vibration frequencies above 20 Hz (structure-borne sound) are determined by the airborne sound field generated inside a particular room and its given surface and extension.

Housing↗

Influence of the partial denture on the articulation of dental and postalveolar sounds.

Dental prosthesis is a foreign body in oral cavity and thus necessarily interferes with speech articulation. The purpose of this study was to examine influence of partial denture on speech quality and to show eventual differences in pronunciation of dental sounds c[ts], z [z], s [s] and postalveolar sounds c [t], z [3] and s [integral of]. We have examined differences in pronunciation between subjects with removable partial dentures, the same group without partial dentures and a control group. The study was performed on 30 subjects with removable partial dentures and 30 subjects with complete dental arch. All subjects were recorded while reading six Croatian words containing the examined sounds. Recordings were analyzed with Multispeech Program (Kay Elemetrics Inc.). Acoustic analysis--LPC (linear prediction coding) provided formant peaks (Hz) for each examined sound, its intensity (dB) and formant bandwidths (Hz). Results showed that subjects with partial dentures had 50% less distorted variables and that prostheses did not completely restore articulation of postalveolar sounds. Groups with and without prostheses had lower formant peaks intensities and wider formant bandwidths in comparison to the control group. Partial dentures have not significantly interfered with resonance frequency. At the same time, pronunciation of the examined sounds was significantly improved. However, precision of the articulation movements has deteriorated.

Denture, Partial↗

[A reliable symptom in differential diagnosis of cochlear and retrocochlear neurosensory hypoacusis (study of sound lateralization in Weber's test and ultrasound)].

Sound laterality in Weber test occurs mainly in peripheral defects of the acoustic analyzer (lateral conduction or reception acoustic defects of the cochlea). In retrocochlear unilateral hypoacusis or loss of hearing, laterality in this test is absent in 80-90% of the cases (affection of the VIII nerve root, acoustic nuclei, stem and midbrain conductors). This symptom is most reliable in differentiation of cochlear with retrocochlear unilateral hypoacusis and deafness. In combination of retrocochlear hypoacusis of deafness with impaired sound conduction in the same ear, the sound in Weber test can show a paradoxical laterality in an absolutely deaf ear. This indicates that Weber test sound laterality definitely reflects changes in sound conduction. Ultrasound laterality occurs in the better hearing ear in any unilateral cochlear or retrocochlear lesions, thus complicating recognition of cochlear from retrocochlear affections. Laterality of ultrasound is a sensitive indicator of neurosensory abnormalities. Major trepanation bone defects of the parietotemporal skull did not influence sound laterality in Weber test.

Cochlea↗

[Degradation of reactive red X-3B by ultra sound synergized with zero-valent iron].

The synergistic effects of ultra sound and zero-valent iron were studied by measuring the degradation of X-3B in zero-valent reduction, ultra sound degradation and synergistic systems. The effects of pH, ultra sound power and irradiation time on the synergistic system were explored. The results show that the X-3B is degraded difficultly by ultra sound and the total removal rate is less than 7.75% after 25min ultrasonic irradiation. When pH is 5.0, 7.0 and 9.0, the degradation rate of X-3B in synergistic system is about 1.68, 1.76 and 1.67 times, respectively, than the total removal rate of zero-valent iron reduction plus ultrasound degradation. After 25min ultrasonic irradiation in synergistic system, 99.42% of X-3B is removed at pH7.0. However, the degradation rate of X-3B in zero-valent iron reduction system is much higher than that of synergistic system at pH3.0. The degradation mechanism of X-3B in zero-valent iron reduction system is different from that of synergistic system. The X-3B is degraded into intermediate pollutants in the former, but is degraded completely in the latter. Accordingly, the X-3B can be degraded effectively in the synergistic system of zero-valent iron and ultra sound, when pH is 5.0 approximately 7.0 and the power of ultra sound is 400 approximately 600W.

Azo Compounds↗

Evaluation of a treadmill with integrated force plates for kinetic gait analysis of sound and lame dogs at a trot.

The objective was to compare mean peak vertical force (PVF) obtained with a treadmill with two integrated force plates (TM) with the piezoelectric force platform (FP) for sound and lame dogs at a trot. The aim was also to report the inter-step variability (ISV) for both systems and the effect of lameness on these values. Six sound dogs (20.0-25.5 kg) and six dogs with a grade 2/5 forelimb lameness (17.0-36.1 kg) were used in the study. Dogs were acclimatized and assigned an individual target velocity (1.8-2.2 m/s). Mean PVF measurements were obtained for both TM and FP. Subject velocity was controlled by belt speed on TM and restricted to 0.25 M/s above or below the assigned target velocity for FP. Acceleration was limited to +/- 0.3 M/s2. For the sound dogs, concordance and correlation coefficients of the mean PVF for the front limbs was 0.79 and 0.76, respectively. Concordance and correlation for the rear limbs was 0.90 and 0.81, respectively. For the lame dogs, concordance and correlation for the front limbs was 0.73 and 0.59, respectively. Concordance and correlation for the rear limbs was 0.89 and 0.95, respectively. ISV was 0.94 with TM and 0.84 with FP for the sound dogs and 0.96 with TM and 0.87 with FP for the lame dogs. In conclusion, TM provided rapid PVF measurements, good concordance for the hind limbs, and substantial concordance for the forelimbs in both sound and lame dogs at a trot as compared to FP. Both systems demonstrated excellent ISV for both lame and sound dogs.

Animals↗

[Clinical-experimental examinations on phonetic function in edentulous patients and after insertion of total prostheses measured by the S-sound realization].

Lose of teeth and therapy by prosthesis interfering with the oral sectors that are necessary for S-sound articulation have an important influence on S-sound realization. Hitherto, the resulting S-sound changes used to be evaluated only from a subjective point of view. The application of a complex measuring technique for S-sound analysis permitted to determine the influence of the upper and lower jaw plates on S-sound formation by experiments. In another series of experiments, it was shown that edentulous patients are not able to pronounce the typical S-sound which, however, builds up again immediately after a total prosthesis is inserted. It then stabilizes further within a three-months period of adaptation.

Adult↗

Temporomandibular joint sounds: a critique of techniques for recording and analysis.

Sonography, or the graphic recording of sounds, has been proposed as an objective measure of various pathological conditions in the temporomandibular joint. Various electronic devices have been developed to enhance our ability to auscultate the joint, monitor the timing of the sounds with jaw movement, and analyze the characteristics of the sound; the intent of these devices is to diagnose the intracapsular condition "objectively." This review paper critically evaluates the advantages and limitations of this technique. Based on the existing literature, these instruments can record sounds; however, the origin of these sounds is uncertain, since room noise, skin and hair sounds, respiration, arterial blood flow, and cross-over noises from the opposite TMJ have not been excluded as possible artifacts of the recording. More important, the diagnostic specificity, as an indicator of each type of TMJ disease, has not been clearly and consistently demonstrated with the sonographic technique.

Auscultation↗

[Acoustical analysis of joint-sound through passive motion--with special reference to degenerative osteoarthrosis of the knee joints].

Sounds from the joints are still in the mysterious zone. It seems to be important to study the sound which occurs on motions. Here, a new analysing method and its clinical application are presented and discussed. The joint which is studied, is moved in some ranges for four seconds in the unechoic chamber, and a special microphone is kept to touch on the pan-articular skin manually throughout the motion. These collected sounds are analyzed with a narrow band spectrum analyzer (Br uel & Kjaer Co., 2031 Type) and a computer. In the unechoic chamber, it may diminished the background noises. The narrow band spectrum analyzer made it possible not to use the magnetic tape which usually induced much noise. Furthermore, as the computer system is utilized, it become easy to compile the data of each frequency analysis and to obtain over all value, with which the sound volume can be compared with each other. The over all value means an integrated volume of each joint sound. In this paper, joint sound were obtained from normal and pathological human joints. In the normal cases, the frequency analysis data showed almost flat spectrum curves, and the total over all values (0.5 kHz to 5 kHz) were usually less than 80 dB. On the other hand, in the pathological joints which had bony changes affected by rheumatoid arthritis, degenerative osteoarthritis, fracture, and others, the frequency analysis showed elevated curves in range from 0.5 kHz to 4.0 kHz, and the total over all value increased in each pathological joint. In 85 cases of osteoarthrosis of the knee joints, the total over all values were a wide dispersion from 76 to 104 dB. And these values and radiological grading (by Swanson) correlated to each other. The over all values at each 0.5 kHz interval, especially from 0.5 to 1.5 kHz, were maximum ones in each radiological gradings. It is concluded that these results in osteoarthrosis cases, are related to with radiological gradings.

Acoustics↗

Physical analysis of the Björk-Shiley prosthetic valve sound.

The closing sound of an implanted Björk-Shiley heart valve prosthesis can be heard clearly in the proximity of the patient. A clinical interrogation of 35 patients showed that 16 (46%) were disturbed by the clicking noise and 10 (29%) reported disturbance of those nearby. A silent prosthesis would be preferred by 15 (43%) patients, eight (23%) declined such a valve for reasons of their own security, and 12 (34%) patients were undecided. The frequency spectrum of the metallic closing sound and its loudness were measured by noninvasive techniques in 20 patients. In the aortic as well as in the mitral position, a high peak of the sound pressure level was registered at 9.8 kHz. In 20 patients the average value of the sound pressure level was 35 dbA measured at a distance of 10 cm from the patient's chest. In vitro studies demonstrated a high peak of the sound pressure level at 9.5 kHz for the Björk-Shiley valve when recorded in free air and at 7 kHz in a standardized valve chamber of a mock circulatory system filled with blood or water. A decrease of the sound pressure level could be achieved by a textile wrap around the chest which damps frequencies around 10 kHz. This protects those nearby but not the patient, who hears the clicking mainly through internal conduction. This unpleasant valve noise can be eliminated only during construction of a new prosthesis provided that such "minor" side effects are measured and taken into consideration.

Acoustics↗

Cortical activation during sound stimulation in cochlear implant users demonstrated by positron emission tomography.

Three patients with prelingual deafness and six patients with postlingual deafness using multichannel cochlear implants were examined by positron emission tomography using 15O-labeled water. Changes in regional cerebral blood flow (rCBF) were measured during three different sound stimuli: 1) with no sound stimulation, with the speech processor of the cochlear implant system switched off, 2) hearing white noise, and 3) hearing sequential Japanese sentences. In postlingually deaf patients, speech stimulation caused a significantly greater rCBF increase compared with noise stimulation in the left immediate auditory association area and the bilateral auditory association areas. In these patients, speech sound is thought to be processed by means of auditory cortices analogous to those in normal subjects. In contrast, in prelingually deaf patients, speech sound induced much less rCBF increase in auditory association cortices; this finding suggested underdevelopment of the neural network for complex sound analysis and speech sound recognition.

Acoustic Stimulation↗

Relationship of eggshell ultrastructure and shell strength to the soundness of shell eggs.

Factors affecting the soundness of shell eggs are of primary concern to egg processors due to substantial financial losses from cracked and leaker eggs. Ultrastructural analyses were used to examine the palisade layer width and mammillary knob layer thickness of sound, cracked, and leaker eggshells. Subjective observations were also made. There was no significant difference (P > 0.05) in the width of the palisade layer or the mammillary knob layer among sound, cracked, and leaker eggshells. The eggshell strengths of sound, cracked, and leaker eggs were evaluated using puncture force and shell thickness measurements. Sound eggshells were found to have a significantly (P < 0.05) higher mean puncture force (35.3 N) than cracked (30.4 N) and leaker (28.4 N) eggshells. The mean puncture force values for cracked and leaker eggshells were not significantly different from each other (P > 0.05). Regression and correlation analyses indicated a significant correlation (P < 0.01; r = 0.61) between palisade layer width and puncture force. The mean shell thickness values for cracked (0.36 mm) and leaker (0.35 mm) eggs were significantly lower (P < 0.05) than those of sound eggs (0.38 mm), although cracked and leaker eggshell thickness did not differ significantly (P > 0.05). The correlation coefficient between puncture force and shell thickness was significant (P < 0.01; r = 0.56), indicating a possible relationship.

Animals↗

Sound-evoked activity in primary afferent neurons of a mammalian vestibular system.

HYPOTHESIS: Some primary vestibular afferents in the cat respond to sound at moderately intense sound levels. BACKGROUND: In fish and amphibians, parts of the vestibular apparatus are involved in audition. The possibility was explored that the vestibular system in mammals is also acoustically responsive. METHODS: Microelectrodes were used to record from single afferent fibers in the inferior vestibular nerve of the cat; some acoustically responsive fibers were labeled intracellularly with biocytin. RESULTS: Vestibular afferents with regular spontaneous activity were unresponsive to sound, whereas a sizable fraction of vestibular afferents with irregular activity were acoustically responsive. Labeling experiments demonstrated that acoustically responsive afferents innervate the saccule, have cell bodies in Scarpa's ganglion, and project to central regions both inside and outside the traditional boundaries of the vestibular nuclei. Acoustically responsive vestibular afferents responded to sound with shorter latencies than cochlear afferents but had higher thresholds (> 90 dB sound pressure level) and responded only in the range 0.1-3.0 kHz. In contrast to cochlear afferents, efferent stimulation excited background activity and proportionately increased sound-evoked responses in these vestibular afferents, that is, there was centrally mediated enhancement of gain (gain = spike-rate/motion). CONCLUSIONS: The evolutionary conservation of a saccular auditory pathway in mammals suggests that it confers survival advantages. Recent evidence suggests that acoustically responsive saccular afferents trigger acoustic reflexes of the sternocleidomastoid muscle, and hence measurement of such reflexes may provide a relatively simple test for saccular dysfunction.

Acoustic Stimulation↗

[Plasticity of reactions of the sensomotor cortex to sound combined with electrophoretic application of acetylcholine].

Reactivity to sound and electrophoretic application of acetylcholine-chloride (ACH) was studied in 170 sensorimotor units of non-anaesthetized rats. Reactivity to sound was found in 60 per cent of the cells, and to ACH, in 83 per cent. Plasticity of the reaction to sound ("conditioned stimulus") was studied in 44 units, when it was presented jointly with ACH ("unconditioned stimulus"). After pairing, the reaction to sound changed in 14 units out of 36 (40%). In the control procedures of pseudoconditioning, reactivity to sound changed in four units out of 15 (27%). Pseudoconditioning and stimuli pairing was successively carried out in seven units: four units manifested plasticity of their reactivity, two of them changed the response to sound both during pseudoconditioning and subsequent pairing of stimuli. It is assumed that the plastic properties of the examined neurones are determined by the integrative activity of the cell micropool with a radius of 70 to 150 mu.

Acetylcholine↗