Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SPECIMEN HANDLING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

Sample collection guidelines for trace elements in blood and urine. IUPAC Commission of Toxicology.

This paper presents an organized system for element-specific sample collection and handling of human blood (whole blood, serum or plasma, packed cells or erythrocytes) and urine also indicating a proper definition of the subject and sample. Harmonized procedures for collection, preparation, analysis and quality control are suggested. The aim is to assist scientists worldwide to produce comparable data which will be useful on a regional, national and international scale. The guidelines are directed to the elements aluminium, arsenic, cadmium, chromium, cobalt, copper, lead, lithium, manganese, mercury, nickel, selenium and zinc. These include the most important elements measured for their occupational or clinical significance, and serve as examples of principles that will guide development of methods for other elements in the future.

Blood Specimen Collection↗

Nitric oxide prevents intestinal mitochondrial dysfunction induced by surgical stress.

BACKGROUND: The intestine is highly susceptible to free radical-induced damage and earlier work has shown that surgical stress induces generation of oxygen free radicals in enterocytes, resulting in intestinal damage along with changes in mitochondrial structure and function. Nitric oxide is an important mediator of gastrointestinal function and this study looked at the effect of nitric oxide on surgical stress-induced intestinal mitochondrial alterations. METHODS: Controls and rats pretreated with the nitric oxide donor L-arginine were subjected to surgical stress by opening the abdominal wall and handling the intestine. Enterocytes were isolated, mitochondria prepared and the protection offered by L-arginine against damage due to surgical stress was determined. Protection to structural as well as functional aspects of mitochondria was examined. RESULTS: Mild handling of the intestine affected the enterocyte mitochondrial structure as assessed by lipid composition and electron microscopy. Mitochondria were also functionally impaired with altered calcium flux and decreased respiratory control ratio. Pretreatment with the nitric oxide synthase substrate L-arginine prevented these damaging effects of surgical stress. Protection with arginine was abolished by the nitric oxide synthase inhibitor NG-nitro-L-arginine methyl ester, indicating the role of nitric oxide. CONCLUSION: Surgical stress in the small intestine can affect enterocyte mitochondrial structure and function. These damaging effects can be prevented by nitric oxide, an important modulator of cellular function.

Animals↗

The effect of sample preparation and storage on maternal triple-marker screening.

OBJECTIVE: To evaluate the effect of different sample collection, storage, and preparation techniques on serum alpha-fetoprotein (AFP), beta-hCG, and unconjugated estriol (E3) concentrations. METHODS: A solution containing known concentrations of AFP, hCG, and unconjugated E3 was diluted in blood samples obtained from seven healthy male volunteers. Serum from each blood sample was removed immediately, and either assayed or frozen at -70C. Portions of the remaining blood were handled as follows: centrifuged and refrigerated, centrifuged and left at room temperature, not centrifuged and refrigerated, or not centrifuged and left at room temperature. Serum was removed from these samples for triple-marker analysis at 24, 48, 96, and 168 hours after the initial sample collection. RESULTS: Immediate freezing of serum and subsequent thawing resulted in a significant increase in beta-hCG and unconjugated E3 levels, but no change in AFP levels. There was a significant effect over time on AFP, hCG, and unconjugated E3 concentrations. The change in AFP levels was influenced by centrifugation status, whereas all three analytes were influenced by refrigeration status. CONCLUSION: Different sample collection, storage, and preparation techniques may affect maternal triple-marker screening.

Chorionic Gonadotropin↗

Sample handling and storage for the quantitative analysis of volatile compounds in blood: the determination of toluene by headspace gas chromatography.

The problems associated with the handling and storage of blood samples for the analysis of toluene in toxicological casework using headspace gas chromatography have been investigated. Significant losses of toluene and the internal standard, ethylbenzene, from solution may be observed during handling. Toluene may be lost into the headspace above the blood in a storage container while such headspaces can also be detrimental, leading to the formation of n-hexanal, a possible interference with the assay. Large differences in the stability of toluene were seen for blood samples in different types of storage container. Storage containers in which the sample was only in contact with glass, teflon, or aluminum foil were most satisfactory. It is recommended that blood samples should be stored in appropriate containers with minimum headspace under cold conditions (4 degrees C). Transfers of blood should also be made at cold temperatures. The applicability of these guidelines to the analysis of other volatile compounds is discussed.

Blood Preservation↗

[Stability of hepatitis C virus RNA in various processing and storage conditions].

The study was purposed to investigate whether processing and storage conditions might influence the stability of the HCV RNA in whole blood or in plasma. The samples obtained from seven patients known to be positive for HCV RNA were kept in different storage conditions with different anticoagulants, and at the end of processing the plasma samples were frozen at -80 degrees C until fluorescent quantitative PCR testing. The results showed that there was no significant loss of HCV RNA titers in whole blood anticoagulated with CPDA or ACD or EDTA or none (P > 0.05), while differences in comparison of the EDTA-anticoagulant storage condition with three other anticoagulants storage conditions at 4 degrees C after 48 hours were significant (P < 0.05). The HCV RNA level decreased to 53.8%, 72.5% and 29.8% after 48 hours of storage of whole blood anticoagulated with ACD at 4 degrees C, 25 degrees C and 37 degrees C respectively. The HCV RNA level of plasma samples stored at 4 degrees C and at 25 degrees C (room temperature) after 7 days decreased to 70.9% and 25.1% respectively. After four freeze-thaw cycles the HCV RNA level decreased 38.9% in plasma samples. It is concluded that the HCV RNA is stable relatively. The HCV RNA is resistant to degradation under routine laboratory handling and storage conditions or blood collection, transport and processing conditions. The influence of different anticoagulants on the stability of HCV RNA is different. Blood samples would better be stored at 4 degrees C after collection and plasma separated within 48 hours. And it is important for the stability of HCV RNA undergoing asepsis blood collection process. HCV RNA remains stable at 4 degrees C for at least 7 days or at room temperature for 3 days, allowing greater flexibility in samples collection and transport in transfusion practice nowadays. HCV RNA in plasma samples subject to up to three short-term freeze-thaw cycles is still stable.

Blood Donors↗

Sample preparation for biomedical analysis.

A review of sample preparation techniques for biomedical analysis is presented. Firstly, sample preparation techniques can be divided into unit operations which can be classified into four groups: release of the analyte from the matrix, removal of endogenous material, liquid handling procedures and the enhancement of selectivity and sensitivity. The concept of unit operations gives an analyst a tool with which to evaluate critically any method for preparing a sample for analysis. Secondly, the major techniques of sample preparation (protein precipitation, liquid-liquid extraction, liquid-solid extraction and high-performance liquid chromatography, HPLC) are discussed and their advantages and disadvantages presented. Thirdly, the rationale for the automation of sample preparation is reviewed; in general liquid-solid extraction and HPLC are the best techniques for automation. The means by which this can be effected (either flexible or dedicated automation) is discussed. Finally, techniques such as supercritical fluid extraction, micellar liquid chromatography, microwave energy and immunoextraction which may be applied to biomedical sample preparation are evaluated briefly.

Chemistry Techniques, Analytical↗

What criteria reliably distinguish melanoma from benign melanocytic lesions?

The differential diagnosis of melanocytic lesions is fraught with difficulty and a common source of litigation either if a lesion misreported as 'benign' recurs locally or re-presents with nodal metastases or if an atypical naevus is called 'malignant' leading to a cosmetically unsatisfactory wider resection, unwarranted anxiety about prognosis and adverse life insurance prospects. Several authors have claimed that there are valid morphological criteria which, alone or in combination, enable reliable distinction between benign and malignant melanocytic lesions. Others question these criteria and, doubting the extent to which unequivocal diagnoses can be rendered in all cases, believe that the diagnosis is purely subjective and that most diagnostic errors are non-negligent. To address these issues, expert opinions were commissioned from three sets of authors. Okun, Edelstein & Kasznica emphasize that a significant minority of melanocytic lesions are so borderline morphologically that diagnostic uncertainty is allowable and that such uncertainty can be handled responsibly. Kirkham, in favouring the methodical use of criteria, concedes that they are 'largely opinion-based rather than evidence-based, but do go beyond mere subjective pattern analysis'. In agreement with Okun and his colleagues. Slater emphasises that no single feature is reliable by itself and that all aspects, including clinical details, should be interpreted together; he has no hesitation in reporting the diagnosis as 'uncertain' in doubtful cases. In the absence of a specific marker pathognomonic of melanocytic malignancy, the diagnosis will continue to rely on the judicious application of morphological criteria with a small proportion of elusive cases in which diagnostic uncertainty should not be concealed.

Biomarkers, Tumor↗

Environmental factors influencing the immune responses of the common European starfish (Asterias rubens).

The influence of handling, salinity, temperature, parasitism, and gender on the immune responses (reactive oxygen species (ROS) production and coelomic amoebocyte concentration (CAC) of the starfish Asterias rubens was investigated in experimental conditions. Additionally, a year-round monthly survey in two distant sites was conducted in order to understand which of these factors most influences the immunity of A. rubens in field conditions. All considered factors, except gender and handling stress, influenced the studied immune responses of A. rubens in experimental conditions. Amoebocyte ROS production was increased at low salinity and at the lowest temperature tested (6 degrees C). Amoebocyte concentration in the coelomic fluid was increased in starfish infested by the ciliate Orchitophrya stellarum. However, among all these factors, only temperature could be linked with the variability in ROS production measured in the field during the monthly survey. The variability in amoebocyte concentration in the field does not seem to be linked to any of the factors considered in this study; it appears to reflect mostly an inter-individual variation rather than seasonal fluctuations. Recommended periods and indicative values of immune responses are proposed for field studies using A. rubens.

Animals↗

Adequate sampling in cryoglobulinaemia: recommended warmly.

Propersample handling is important for the accurate and prompt diagnosis of cryoglobulinaemia as well as for obtaining correct results of other laboratory tests. In this case report, we present two patients for whom improper sampling delayed the diagnosis of cryoglobulinaemia. The routine sampling procedure was not sufficient for detecting these cryoglobulins and we demonstrated that the temperature dropped below 37 degrees C at different steps during the sample preparation. Adjusting the preanalytical procedure revealed that both patients possessed a cryoglobulin with high thermal insolubility. We conclude that in cryoglobulinaemia strict adherence to guidelines to keep the temperature >37 degrees C is crucial for sample collection and must be strongly recommended.

Clinical Laboratory Techniques↗

Parallel DNA template preparation using a vacuum filtration sample transfer device.

Solid-phase techniques have facilitated the handling of biochemical analytes. This has stimulated the development of systems by which large sample panels can be analyzed with high levels of security and quality. We describe a sample transfer device based on the principle of vacuum filtration, which enables parallel handling of 96 samples of analytes bound to Sepharose beads. The tool was employed for strand separation of DNA samples, by attracting the beads to filter probes while passing them between the reagent solutions. The samples were analyzed using Pyrosequencing technology and proved to yield genotyping results of high quality. The presented sample preparation procedure provides an important link in the development of integrated systems for rapid genetic analysis at a low cost. In addition, the same filter could be reused extensively with very low risk for detectable cross-contamination between assays and without any reduction in processing capacity, thus further reducing the cost per analyzed sample.

DNA↗

Screening for drugs of abuse: effect of heat-treating urine for safe handling of samples.

Heating urine samples from high-risk patients for 1 h at 56 degrees C is no longer believed to completely inactivate human immunodeficiency virus (HIV; AIDS virus). To protect staff who are handling infectious samples such as those from drug-addiction units, heating at a higher temperature may be necessary. We report the stability to heat treatment (at 60, 70, and 100 degrees C) at pH 5.1 and 7.6 of some commonly abused drugs, namely, methadone, pethidine, amphetamine, the cocaine metabolite, benzoylecgonine, and the dextropropoxyphene metabolite nordextropropoxyphene. Heat-treating urine at 60 degrees C for 1.5 h or 70 degrees C for 1 h did not significantly affect the measured concentrations of these drugs. However, heat treatment at 100 degrees C for 1 h reduced the recovery of all the drugs. Benzoylecgonine and amphetamine were most susceptible to the different forms of heat treatment.

Acquired Immunodeficiency Syndrome↗

Liver tissue characterization by in vitro NMR: tissue handling and biological variation.

The extraction of reliable and useful relaxation time data for tissue characterization by NMR requires strict protocols, optimized for each type of biological tissue, which include parameters like storage duration and temperature as well as measurement parameters. Spin-lattice relaxation times in liver tissue vary not only with NMR frequency but also with their "time-after-excision characteristics," while spin-spin relaxation times are almost independent of most parameters which influence T1 at 20 MHz in normal liver tissue (e.g., species, sex, circadian rythm, starvation). T2, however, being more sensitive to water content and pH changes, is well suited for detecting nonspecific tissue alterations (e.g., due to ischemia, chemical toxins). Following the suggestions outlined herein, investigation of at least 120 min of time-after-excision (storage) effects allows the significant distinguishing of various physiological differences in normal liver tissue as well as improvement of early detection of liver pathologies.

Animals↗

The effect of handling methods on subsequent plasma progesterone levels in sheep.

The mean progesterone concentration in the plasma of 10 adult Ethiopian Highland sheep obtained immediately after slaughter was 10.56 +/- 3.98 ng/ml. Samples were subsequently incubated at 4 degrees C, room temperature (19-22 degrees C) or 26 degrees C as either plasma or intact but citrated blood. Failure to separate plasma affected the progesterone content at 2-72 h at room temperature or 26 degrees C (p less than 0.01 - p less than 0.0001). Incubation temperature affected the plasma concentration at 18 h (p less than 0.05) and 24 h (p less than 0.001). Although progesterone values were generally higher in separated plasma, disparity with the values from plasma separated from incubated citrated blood was small (r = 0.76-0.98). Progesterone concentration declined haphazardly after collection but sometimes exceeded the initial readings. This kept the average concentration of progesterone in plasma separated immediately after collection fairly constant and within 15% of zero time samples during the first 48 h.

Animals↗

Sample handling for mass spectrometric proteomic investigations of human sera.

Proteomic investigations of sera are potentially of value for diagnosis, prognosis, choice of therapy, and disease activity assessment by virtue of discovering new biomarkers and biomarker patterns. Much debate focuses on the biological relevance and the need for identification of such biomarkers while less effort has been invested in devising standard procedures for sample preparation and storage in relation to model building based on complex sets of mass spectrometric (MS) data. Thus, development of standardized methods for collection and storage of patient samples together with standards for transportation and handling of samples are needed. This requires knowledge about how sample processing affects MS-based proteome analyses and thereby how nonbiological biased classification errors are avoided. In this study, we characterize the effects of sample handling, including clotting conditions, storage temperature, storage time, and freeze/thaw cycles, on MS-based proteomics of human serum by using principal components analysis, support vector machine learning, and clustering methods based on genetic algorithms as class modeling and prediction methods. Using spiking to artificially create differentiable sample groups, this integrated approach yields data that--even when working with sample groups that differ more than may be expected in biological studies--clearly demonstrate the need for comparable sampling conditions for samples used for modeling and for the samples that are going into the test set group. Also, the study emphasizes the difference between class prediction and class comparison studies as well as the advantages and disadvantages of different modeling methods.

Humans↗

A hybrid poly(dimethylsiloxane) microsystem for on-chip whole blood filtration optimized for steroid screening.

Miniaturized biochemical devices in glass, silicon and polymer materials are starting to find their way from the academic laboratories to real-life applications. However, most attention has been given to miniaturize the downstream functions of various microfluidic systems, leaving the sample introduction and preparation steps to more conventional, bulkier solutions. For point-of-care diagnostics in particular, it becomes crucial to be able to handle complex human samples in a miniaturized format.In this work, we report on a microsystem for on-chip sample preparation that is able to remove blood cells from whole blood. The hybrid system consists of a commercially available membrane filter incorporated into a poly(dimethylsiloxane) (PDMS) casted device. Membrane materials were evaluated on the bases of low nonspecific adsorption of free and protein-bound testosterone as analyte substance. The hybrid system including a hydrophilic polypropylene filter successfully removed blood cells from diluted human whole blood. Surface oxidation was sufficient to make the plasma filtrate flow through the membrane filter and the channel system by capillary force alone and thus no external pumping source was needed.

Biocompatible Materials↗

Modified enzyme-based colorimetric assay of urinary and plasma oxalate with improved sensitivity and no ascorbate interference: reference values and sample handling procedures.

The measurement of oxalate in urine and plasma continues to be difficult, particularly in the presence of ascorbate. We have modified and validated a colorimetric assay involving the use of oxalate oxidase (EC 1.2.3.4). Modification of an HPLC spectrophotometric detector improved sensitivity (to as much as 1000-fold that of conventional spectrophotometers) and allowed measurement of oxalate concentrations less than 1 mumol/L. This provided more than enough sensitivity for measurement of normal concentrations of plasma oxalate. We established reference values for oxalate concentrations in urine and plasma, studied sample handling, and established conditions to avoid ascorbate interference in urine and plasma measurements. Mean analytical recovery of [14C]oxalate from plasma to the filtrate was 86 (SD 10)%; recovery of unlabeled oxalate from filtrate was 87 (SD 9)%. Urinary oxalate excretion rates in apparently healthy controls were 0.11-0.46 mmol/24 h. Plasma concentrations in control subjects were 2.5 (SD 0.7) mumol/L, similar to concentrations determined by recent gas chromatographic and isotope dilution methods. Frozen and acidified urine samples showed no interference from ascorbate when excess ascorbate was avoided. Ingestion of 2 g of ascorbate daily did not increase urinary oxalate in healthy control subjects, but during storage ascorbate was converted to oxalate in all conditions tested.

Adult↗

The extraction of aged polycyclic aromatic hydrocarbon (PAH) residues from a clay soil using sonication and a Soxhlet procedure: a comparative study.

A sonication method was compared with Soxhlet extraction for recovering polycyclic aromatic hydrocarbons (PAH) from a clay soil that had been contaminated with tar materials for several decades. Using sonication over an 8 h extraction period, maximum extraction of the 16 US EPA priority PAH was obtained with dichloromethane (DCM)-acetone (1 + 1). The same procedure using hexane-acetone (1 + 1) recovered 86% of that obtained using DCM-acetone (1 + 1). PAH recovery was dependent on time of extraction up to a period of 8 h. The sonication procedure showed that individual PAH are extracted at differing rates depending on the number of fused rings in the molecule. Soxhlet extraction [with DCM-acetone (1 + 1)] over an 8 h period recovered 95% of the PAH removed by the sonication procedure using DCM-acetone (1 + 1), indicating that rigorous sonication can achieve PAH recoveries similar to those obtained by Soxhlet extraction. The lower recovery with the Soxhlet extraction was explained by the observed losses of the volatile PAH components after 1-4 h of extraction. The type of solvent used, the length of time of extraction and extraction method influenced the quantification of PAH in the soil. Therefore, the study has implications for PAH analyses in soils and sediments, and particularly for contaminated site assessments where the data from commercial laboratories are being used. The study emphasizes the importance of establishing (and being consistent in the application of) a vigorous extraction, particularly for commercial laboratories that handle samples of soil in batches (at different times) from a single site investigation or remediation process. The strong binding of PAH to soil, forming aged residues, has significant implications for extraction efficiency. This paper illustrates the problem of the underestimation of PAH using the US EPA method 3550, specifically where a surrogate spike is routinely employed and the efficiency of the extraction procedure for aged residues is unknown. The implications of this study for environmental monitoring, particularly where numerous batches of samples from a single site assessment or remediation program are submitted to commercial laboratories, is that it would be advisable for these laboratories to check their existing method's extraction efficiencies by conducting a time course sonication extraction on their particular soil to determine the optimum extraction time.

Chemistry Techniques, Analytical↗

Disappearance of calcium and other electrolytes from microvolume samples.

Studies involving micropuncture and microperfusion of single nephrons require the handling of very small fluid samples. To facilitate handling, the tubule fluids are normally manipulated under paraffin oil. Calcium and, to a lesser extent, magnesium and phosphate concentrations may change significantly when placed in hydrated paraffin oil. Fluids of alkaline pH (about 7.4), either intrinsic or because of loss of CO2, may very quickly lose calcium in paraffin oil. Evidence suggests that this is due to a reversible binding of calcium and perhaps magnesium to the aqueous-oil interface that is dependent on the pH of the sample. It is recommended that tubule fluid samples be kept acidic to prevent calcium loss. A convenient method is by equilibrating the paraffin oil, prior to placement of aqueous samples, with a CO2 tension sufficient to lower the sample pH to below 7.0.

Animals↗