Use of plain radiography and computed tomography to identify fish bone foreign bodies.

INTRODUCTION: Fish bones are the most common aerodigestive foreign bodies in adults. Radiographic studies, often ordered for diagnosis, have questionable utility. METHODS: With a laryngoscope, bones from 10 fish species were placed in a variety of positions in a human head and neck cadaver specimen. Plain films and CT scans were obtained and evaluated by blinded readers. RESULTS: Plain radiography exhibited a sensitivity and specificity of 39% and 72%. Cooking did not grossly change radio-opacity. The species of fish affected visibility in soft tissue, without correlation to the characteristic optical density of each species. Bones placed orthogonal to the film in the vallecula were most readily identified. CT scanning correctly identified 9 of 10 bones. CONCLUSIONS: Plain radiography poorly visualizes fish bone foreign bodies in soft tissue; visibility varied with fish species, location, and orientation. CT is the test of choice to radiographically diagnose fish bone impactions.

Adult↗

A comparison of nasopharyngeal endoscopy and lateral cephalometric radiography in the diagnosis of nasopharyngeal airway obstruction.

Two auxiliary methods of diagnosing nasopharyngeal airway obstruction were compared. Cephalometric radiography and nasopharyngeal videoendoscopy were evaluated for efficacy in terms of reproducibility and validity. Thirty orthodontic patients (7 to 12 years of age) seeking otorhinolaryngologic treatment for mouth breathing, or mouth and nose breathing, had nasopharyngeal endoscopy and radiographic examinations performed on the same day. Two otorhinolaryngologists analyzed the results. Nasopharyngeal endoscopy was more reliable in identifying all the obstructive nasopharyngeal processes. Endoscopy obtained kappa index scores of almost perfect agreement for diagnosis of posterior nasal septum deviation, of substantial agreement for anterior nasal septum deviation and lower turbinate hypertrophy, and of moderate agreement for middle turbinate hypertrophy. Lateral cephalometric radiography obtained scores of perfect agreement for imaging hypertrophy of the middle turbinate, of almost perfect agreement for imaging hypertrophy of the posterior portion of the inferior turbinate, and of substantial agreement for imaging hypertrophy of the inferior turbinate. Radiographic diagnoses of hypertrophy of the middle and lower turbinates exhibited high sensitivity and low specificity when compared with diagnoses by nasopharyngeal endoscopy.

Cephalometry↗

Influence of developer exhaustion on accuracy of quantitative digital subtraction radiography: an in vitro study.

OBJECTIVE: The aim of the study was to evaluate the influence of developer exhaustion on accuracy of quantitative digital subtraction radiography. STUDY DESIGN: Six objects, each incorporating a section of dry human mandible, were radiographed with 4 exposure times. Baseline films were processed in fresh solutions, whereas follow-up films were processed in fresh and in increasingly exhausted solutions (ie, 1, 2, and 3 weeks old). Bone loss and bone gain were computer simulated in 17 regions of interest on baseline radiographs. Area and volume of changes in mineralization were measured in subtracted images, obtained by subtraction of baseline from their corresponding follow-up radiographs. Friedman's 2-way analysis of variance by ranks and Wilcoxon signed-rank test were used for statistical analysis. RESULTS: Because of exhausted developer, bone loss was relatively underestimated from 6.6% to 16.5% (P <.05), whereas bone gain was relatively overestimated from 9.7% to 16.7% (P <.05). CONCLUSIONS: This in vitro study demonstrates that films for quantitative digital subtraction radiography should be processed in fresh developer or error might be introduced.

Alveolar Bone Loss↗

Medial instability of the elbow: findings on valgus load radiography and MRI in 16 athletes.

Medial discomfort of the elbow in athletes can be due to valgus instability after acute ligament rupture or attenuation of the medial collateral ligament caused by repetitive microtrauma during overhead throwing. We studied 16 athletes with medial instability of the elbow due to insufficiency of the medial collateral ligament. 4 patients had sensory ulnar nerve symptoms, of whom 2 had abnormalities of the ulnar nerve on electromyography. 13 showed an increase in the ulno-humeral joint space on dynamic radiography under valgus load. MRI of 10 of these 13 elbows revealed rupture of the medial collateral ligament or avulsion of the medial collateral ligament. Dynamic radiography under valgus load seems to be of value for the diagnosis of chronic medial collateral ligament insufficiency.

Adult↗

Chest radiography in ambulatory children with acute lower respiratory infections: effective tuberculosis case-finding?

A study was performed to determine the proportion of ambulatory children with acute lower respiratory infections in whom clinical management was changed by findings on routine chest radiography that suggested tuberculosis. The children studied were aged between 2 and 59 months and met the World Health Organization's case definition for pneumonia. They lived in an area with a very high prevalence of tuberculosis. Exclusion criteria included a cough of more than 14 days' duration and a history of a current household contact with active tuberculosis. Twelve (4.4%) of 273 children had radiological findings suggesting tuberculosis, nine of which were suspected mediastinal lymphadenopathy. Eight children were further investigated for tuberculosis: seven of them did not require treatment for tuberculosis and one was lost to follow-up. It is concluded that chest radiography in ambulatory children with acute lower respiratory infections of less than 14 days' duration and not in contact with active tuberculosis does not result in a meaningful increase in the diagnosis of tuberculosis.

Acute Disease↗

Computed radiography as a gamma ray detector--dose response and applications.

Computed radiography (CR) can be used for imaging the spatial distribution of photon emissions from radionuclides. Its wide dynamic range and good response to medium energy gamma rays reduces the need for long exposure times. Measurements of small doses can be performed without having to pre-sensitize the computed radiography plates via an x-ray exposure, as required with screen-film systems. Cassette-based Agfa MD30 and Kodak GP25 CR plates were used in applications involving the detection of gamma ray emissions from technetium-99m and iodine-131. Cassette entrance doses as small as 1 microGy (140 keV gamma rays) produce noisy images, but the images are suitable for applications such as the detection of breaks in radiation protection barriers. A consequence of the gamma ray sensitivity of CR plates is the possibility that some nuclear medicine patients may fog their x-rays if the x-ray is taken soon after their radiopharmaceutical injection. The investigation showed that such fogging is likely to be diffuse.

Contrast Media↗

Towards optimization in digital chest radiography using Monte Carlo modelling.

A Monte Carlo based computer model of the x-ray imaging system was used to investigate how various image quality parameters of interest in chest PA radiography and the effective dose E vary with tube voltage (90-150 kV), additional copper filtration (0-0.5 mm), anti-scatter method (grid ratios 8-16 and air gap lengths 20-40 cm) and patient thickness (20-28 cm) in a computed radiography (CR) system. Calculated quantities were normalized to a fixed value of air kerma (5.0 microGy) at the automatic exposure control chambers. Soft-tissue nodules were positioned at different locations in the anatomy and calcifications in the apical region. The signal-to-noise ratio, SNR, of the nodules and the nodule contrast relative to the contrast of bone (C/C(B)) as well as relative to the dynamic range in the image (C(rel)) were used as image quality measures. In all anatomical regions, except in the densest regions in the thickest patients, the air gap technique provides higher SNR and contrast ratios than the grid technique and at a lower effective dose E. Choice of tube voltage depends on whether quantum noise (SNR) or the contrast ratios are most relevant for the diagnostic task. SNR increases with decreasing tube voltage while C/C(B) increases with increasing tube voltage.

Humans↗

Quantitative assessment of computed radiography quality control parameters.

Quality controls for testing the performance of computed radiography (CR) systems have been recommended by manufacturers and medical physicists' organizations. The purpose of this work was to develop a set of image processing tools for quantitative assessment of computed radiography quality control parameters. Automatic image analysis consisted in detecting phantom details, defining regions of interest and acquiring measurements. The tested performance characteristics included dark noise, uniformity, exposure calibration, linearity, low-contrast and spatial resolution, spatial accuracy, laser beam function and erasure thoroughness. CR devices from two major manufacturers were evaluated. We investigated several approaches to quantify the detector response uniformity. We developed methods to characterize the spatial accuracy and resolution properties across the entire image area, based on the Fourier analysis of the image of a fine wire mesh. The implemented methods were sensitive to local blurring and allowed us to detect a local distortion of 4% or greater in any part of an imaging plate. The obtained results showed that the developed image processing tools allow us to implement a quality control program for CR with short processing time and with absence of subjectivity in the evaluation of the parameters.

Calibration↗

Correlation of ureteral stone measurements by CT and plain film radiography: utility of the KUB.

BACKGROUND AND PURPOSE: The practice of utilizing helical CT to evaluate patients suspected of renal colic is increasing. Little is known about the accuracy of CT in estimating stone size or the utility of an accompanying plain abdominal radiograph (KUB film). The purpose of our study was to compare ureteral stone size estimation by helical CT and plain film and determine whether a KUB film provides additional information useful in patient management. PATIENTS AND METHODS: Thirty consecutive patients (17 male, 13 female) having both a helical CT and a KUB study for evaluation of renal colic secondary to ureteral calculi comprised the study population. Calculus number, location, and dimensions were determined from these images. Stone dimensions were measured using electronic calipers on a picture archiving and communications system. Information found by KUB and CT was compared, and both sets of stone measurements were correlated with patient outcome. RESULTS: The mean maximal stone transverse diameter and length were similar on CT and plain film: 5.8 mm v 5.8 mm and 9.5 mm v 8.9 mm, respectively (P = 0.57 and 0.29, respectively). The mean anteroposterior stone diameter on CT of 6.8 mm was statistically greater than the transverse diameter as measured by both CT and KUB, which were 5.8 mm and 5.8 mm (P = 0.0002 and 0.0007, respectively). Eleven patients spontaneously passed their stones, while 19 patients required intervention. Patient outcome, as predicted by transverse stone width, was similar for CT and KUB data. CONCLUSIONS: The management of patients with ureteral calculi relies on estimated stone size and the stone's potential for spontaneous passage. Stone dimensions estimated by CT are similar to the size determined by plain film radiography. Although plain film radiography does not provide information on stone dimensions beyond that obtained with CT, it does reveal precise stone location and radiolucency, data helpful in following and treating patients.

Female↗

Radiography of the pelvis in a series of 200 elderly patients.

Review of the findings of routine radiography of the pelvis in a series of 200 elderly patients admitted to a geriatric department shows that a great number of abnormalities are detected. It is suggested that this procedure is of equal value to routine chest radiography.

Aged↗

AEC set-up optimisation with computed radiography imaging.

Phototimer set-up is a critical procedure for dose and image quality optimisation in computed radiography (CR) systems. While a conventional radiography automatic exposure control device (AEC) can be calibrated in order to gain a constant optical density on the film independent of beam quality and patient size, CR detectors present a high dynamic range which allows a much larger dose interval, but with different image quality levels. CR leads to a less frequent exam repetition, but may produce quite noisy images if the exposure level on the plate is not correct. The aim of this work is to evaluate the performance of a CR plate (Agfa MD40) in order to optimally calibrate an AEC device. The plate response has been characterised in terms of digital signal, exposure on the plate and signal-to-noise ratio for different beam qualities, in a patient of standard size.

Calibration↗

The quality of dental radiography in the Czech Republic--results of a TLD and film postal audit.

Since 2002, the postal audit in dental radiography has been supplementing standard quality control (QC) tools for dental intraoral X-ray machines. An aim of the audit is to check basic X-ray machine parameters (field size, exposure reproducibility), and a quality of the whole process of diagnostic imaging (entrance surface air-kerma measurement, a check of film processing and an image quality evaluation). The standard QC tests, performed by private companies, check mainly the X-ray unit. Conversely, the audit gives better information about the patient examination practices. During the period of January 2002 to May 2004 approximately 4000 audits were performed. The results confirmed that main problems in dental radiography are due to incorrect film processing, non-optimised setting of the exposure parameters and use of obsolete X-ray machines. Only approximately 30% of performed audits were satisfactory with respect to all checked parameters.

Czech Republic↗

Maternal chest radiography as supporting evidence for the diagnosis of tuberculosis in childhood.

Routine chest radiography of the mothers of 163 children investigated for possible tuberculosis accompanied by sputum culture from those mothers with suspicious chest radiographs identified active pulmonary tuberculosis in 12 (10 per cent) of the mothers of the 117 children with probable (49 cases) and confirmed (68 cases) tuberculosis. All but one of the cases of active maternal tuberculosis were identified in the mothers of children less than 1 1/2 years of age. Chest radiography of the mothers of children less than 1 1/2 years of age will aid the diagnosis of tuberculosis in the child and expedite the reduction of the infectious pool of active pulmonary tuberculosis cases in adults in the community.

Adult↗

Plain radiography in the evaluation of knee osteoarthritis.

The prospects for results of controlled studies of disease-modifying osteoarthritis drugs in humans have fostered interest in radiographic methods to detect early cartilage damage and to assess progressive cartilage changes in osteoarthritis of the knee. We summarize here the extent to which technical factors in plain knee radiography-ie, the degree of knee flexion, misalignment of the x-ray beam, magnification of the radiographic image of the joint-and mensural procedures can impact the reproducibility of quantitative measurements of tibiofemoral joint space width, the surrogate for thickness of articular cartilage. Failure to standardize crucial elements of conventional knee radiography and to computerize measurement of tibiofemoral joint space width will introduce significant (and probably insurmountable) error variation into radiographic outcome data. The level of precision achievable with fluoroscopically-assisted flexion of the knee and rotation of the foot with computerized, magnification-corrected measurement of joint space width greatly improves the feasibility of disease-modifying osteoarthritis drug trials as they relate to sample size and duration of treatment necessary to detect an effect from disease-modifying osteoarthritis drugs.

Antirheumatic Agents↗

Disc degeneration and angular movement of the lumbar spine: comparative study using plain and flexion-extension radiography and discography.

A study was made of the association between disc degeneration observed in plain radiographs, in discograms (Adams' classification), and instability expressed as abnormal angular movement of lumbar vertebrae. The series included 169 discs in 77 consecutive patients (42 men, 35 women) whose mean age was 34 (range 16-46) years. Discography was more sensitive than plain radiography in the diagnosis of disc degeneration was more common in men than in women (Chi square test, chi 2 = 9.88, p less than 0.05). An increase in disc degeneration was observed in lower lumbar segments (Chi square test, chi 2 = 48.63 p less than 0.001). However, no association between abnormal angular movement and discogram type was observed (Chi square test, chi 2 = 2.63, p less than 0.05). It seems that disc degeneration seldom results in abnormal angular movement and instability of the lumbar spine. Therefore, flexion-extension radiography may only have limited diagnostic value.

Adolescent↗

The potential impact of digital radiography (DR) on the speciality of nuclear medicine.

Digital radiography is a reasonably economical system that helps diagnostic imaging physicians to develop increasingly less-invasive procedures, obtain maximal information at a given dose and increase the flexibility and convenience involved with diagnostic workups. The range of applications of DR has not been fully established at this time. Comparison of its properties with those of conventional nuclear medicine may suggest areas of potential application. Compared to nuclear medicine techniques, DR in general provides improved anatomical resolution, improved contrast resolution, sometimes equivalent functional information, and decreased imaging time. On the other hand, some functional nuclear medicine studies provide information not available by DR; including the gallium scan, bone scan, hepatic-biliary scan, and lung scan. Therefore, nuclear medicine procedures will be complimentary in some instances to digital radiography procedures and competitive in others. The proper roles of each modality in various clinical settings await future detailed and comprehensive efficacy studies.

Animals↗

X-ray beam energy, scatter, and radiation risk in chest radiography.

Effective doses for patients undergoing chest radiography were computed utilizing updated weighting factors, published organ doses and measured entrance doses. The effective dose decreases with beam energy (kVp) and reaches a minimum value after 100 kVp, with values when a grid is used (6.90 microSv) being 145% higher at this energy than when no grid is used (2.82 microSv). The uncertainties associated with derivation of the tissue weighting factors are shown not to affect the point at which risk is minimized. Use of the effective dose as the measure of risk does not require special treatment of the remainder tissue as with use of effective dose equivalent. The effective dose required for radiographs of constant optical density was examined to incorporate the behavior of the detector's response to energy and compare results to previous work where exit dose was held constant. The effective dose at 120 kVp with a grid (6.84 microSv) is compared to an estimate of that associated with the current kVp distribution (14.55 microSv). Since image quality is enhanced by the grid, its use in conjunction with a beam energy of 120 kVp could maximize the benefit/risk ratio in chest radiography and should be considered for universal implementation. Such adoption could reduce the population risk compared to current practice.

Humans↗

High frequency edge enhancement in the detection of fine pulmonary lines. Parity between storage phosphor digital images and conventional chest radiography.

Fine linear structures represent a severe test of the minimum spatial resolution that is needed for digital chest imaging. We studied the comparative observer performance of storage phosphor digital imaging (1760 X 2140 pixel matrix, 10 bits deep), and conventional radiography (Lanex medium screen, Ortho C film) in the detection of simulated fine pulmonary lines superimposed on the normal chest when exposure factors were identical (20mR skin entrance dose at 141 kVp). Receiver operating characteristics analysis of 2160 observations by six readers found that high frequency edge-enhanced digital images (ROC area: 0.78 +/- 0.06) performed better than unenhanced digital images (ROC area: 0.70 +/- 0.07) (P less than 0.01 for paired t-test), and that edge enhanced digital images performed on a par with conventional radiography (ROC area: 0.78 +/- 0.09). We conclude that for the detection of fine linear structures, storage phosphor digital images can perform on a par with higher resolution conventional chest radiographs when a high frequency edge-enhancement algorithm is employed.

Adult↗