Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Prosthesis Fitting”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

Risk-corrected impact of mechanical versus bioprosthetic valves on long-term mortality after aortic valve replacement.

OBJECTIVE: Choice of a mechanical or biologic valve in aortic valve replacement remains controversial and rotates around different complications with different time-related incidence rates. Because serious complications will always "spill over" into mortality, our aim was to perform a meta-analysis on overall mortality after aortic valve replacement from series with a maximum follow-up of at least 10 years to determine the age- and risk factor-corrected impact of currently available mechanical versus stented bioprosthetic valves. METHODS: Following a formal study protocol, we performed a dedicated literature search of publications during 1989 to 2004 and included articles on adult aortic valve replacement with a mechanical or stented bioprosthetic valve if age, mortality statistics, and prevalences of well-known risk factors could be extracted. We used standard and robust regression analyses of the case series data with valve type as a fixed variable. RESULTS: We could include 32 articles with 15 mechanical and 23 biologic valve series totaling 17,439 patients and 101,819 patient-years. The mechanical and biologic valve series differed in regard to mean age (58 vs 69 years), mean follow-up (6.4 vs 5.3 years), coronary artery bypass grafting (16% vs 34%), endocarditis (7% vs 2%), and overall death rate (3.99 vs 6.33 %/patient-year). Mean age of the valve series was directly related to death rate with no interaction with valve type. Death rate corrected for age, New York Heart Association classes III and IV, aortic regurgitation, and coronary artery bypass grafting left valve type with no effect. Included articles that abided by current guidelines and compared a mechanical and biologic valve found no differences in rates of thromboembolism. CONCLUSION: There was no difference in risk factor-corrected overall death rate between mechanical or bioprosthetic aortic valves irrespective of age. Choice of prosthetic valve should therefore not be rigorously based on age alone. Risk of bioprosthetic valve degeneration in young and middle-aged patients and in the elderly and old with a long life expectancy would be an important factor because risk of stroke may primarily be related to patient factors.

Age Factors↗

Dynamic magnetic resonance angiography of the aneurysm neck: conformational changes during the cardiac cycle with possible consequences for endograft sizing and future design.

OBJECTIVE: Proper proximal fixation and stent-graft sealing within the aneurysm neck are critical for endovascular aneurysm repair (EVAR) durability. Computed tomography angiography (CTA) is the gold standard for preoperative sizing of endograft diameters, but the accuracy of these measurements is uncertain because they rely on static images of a dynamic process. The aortic configuration and diameter may change during the cardiac cycle. We studied these phenomena using dynamic electrocardiograph-triggered magnetic resonance angiography (MRA). METHODS: Eleven consecutive EVAR patients were included. Dynamic MRA was used to perform preoperative and postoperative measurements. Changes were measured in transverse aortic sections 10 mm below the lowest renal artery (level A), at the level of the renal arteries (level B), and 3 cm above the lowest renal artery (level C). Data were analyzed using image segmentation software. Aortic area and diameter changes along 256 axes were determined. RESULTS: Dynamic MRA demonstrated significant aortic area changes during the cardiac cycle before and after EVAR at all three measured levels. Pre-EVAR aortic area significantly increased per cardiac cycle: 8.4% at level A; 9.3% at level B; and 13.3% at level C (P < .001 for all levels). Post-EVAR aortic area increased 9.7% at level A, 9.6% at level B, and 15.8% at level C per cardiac cycle (P < .001 for all levels). Significant diameter changes during cardiac cycles were also observed at all three levels. Pre-EVAR mean diameter changed up to 8.9% (P < .001) compared with post-EVAR aortic changes of up to 11.5% (P < .001). EVAR had no effect on change in aortic area and diameter. Dynamic MRA also demonstrated that pulsatile aortic distension was not equal in all axes, but rather occurred as an asymmetrical expansion and contraction. CONCLUSION: In patients with (atherosclerotic) aneurysm disease, the aortic dimensions at the level of and proximal to the aneurysm neck change during the cardiac cycle. This phenomenon is preserved after EVAR. Therefore, maximum diameter using dynamic MRA may not be similar to the maximum diameter with static CTA in all patients, and a standard regimen of 10% to 15% oversizing of an endograft based on static CTA images may be inadequate for some patients. Further studies using dynamic MRA to evaluate effects of different endografts are anticipated, with possible consequences for endograft designs.

Aged↗

Eversion or subluxation of patella in soft tissue balancing of total knee arthroplasty? Results of a cadaver experiment.

Correct postoperative leg alignment and stability of total knee prosthesis over the full range of movement are critical factors for successful TKA. This is achieved by correct implantation of prosthesis and soft tissue handling. However, the surgical approach and how to displace the patella are still controversial. We have carried out a cadaver study looking at the effect of patella eversion or subluxation on limb axis alignment during balancing of the knee in three different standard surgical approaches; subvastus, midvastus, or medial parapatellar. For each approach, five knees were studied. Leg alignment was visualised by the Ci CT-free DePuy/BrainLAB navigation system. Using a navigation system alignment was determined in the AP axis in both extension and 90 flexion, with the patella everted as well as subluxated. Eversion of the patella gave a more valgus axis reading than subluxation in both extension 0.58 (SD: 0.03, range 0.54 -0.60 ) and 90 flexion 0.48 (SD: 0.11, range 0.38 -0.60 ). The effect was greatest using the medial paraptellar approach. Surgeons should be aware that everting the patella influences the AP alignment when soft tissue balancing in total knee replacement.

Arthroplasty, Replacement, Knee↗

The role of preoperative templating in total knee arthroplasty: comparison of three prostheses.

Templating of preoperative radiographs is routinely recommended prior to knee arthroplasty. We performed this study to assess the reproducibility and accuracy of the templates for three commonly used knee implants (PFC, Kinemax, Scorpio). Six lower limb surgeons templated 10 patients for each of the three designs. The inter- and intra-observer reliability and accuracy was calculated. There was marked variation in the reliability of the templating with the tibial insert scoring better than the femoral and the Kinemax being the most reproducible of the three. In general, the intra-observer scores (kappa=0.57-0.81) were better than the inter-observer ones (kappa=0.21-0.60). The Scorpio was the most accurately templated of the three implants, with the percentage correlating with what was actually implanted ranging from 55% to 62% for the femur and 72% to 75% for the tibia, with no templated sizes more than one size different from the actual implant. The other implants ranged from 38% to 42% for the femur and 53% to 58% for the tibia with both having up to 3% more than 1 size difference from the actual implant. We believe that the use of templating in total knee arthroplasty should be interpreted with caution and we urge the development of more accurate prosthesis sizing techniques.

Arthroplasty, Replacement, Knee↗

Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket.

Finite element method has been identified as a useful tool to understand the load transfer mechanics between a residual limb and its prosthetic socket. This paper proposed a new practical approach in modeling the contact interface with consideration of the friction/slip conditions and pre-stresses applied on the limb within a rectified socket. The residual limb and socket were modeled as two separate structures and their interactions were simulated using automated contact methods. Some regions of the limb penetrated into the socket because of socket modification. In the first step of the simulation, the penetrated limb surface was moved onto the inner surface of the socket and the pre-stresses were predicted. In the subsequent loading step, pre-stresses were kept and loadings were applied at the knee joint to simulate the loading during the stance phase of gait. Comparisons were made between the model using the proposed approach and the model having an assumption that the shape of the limb and the socket were the same which ignored pre-stress. It was found that peak normal and shear stresses over the regions where socket undercuts were made reduced and the stress values over other regions raised in the model having the simplifying assumption.

Algorithms↗

The kinematic importance of radial neck length in radial head replacement.

Comminuted radial head fractures can be treated with a radial head implant. The effects of lengthening (2.5 mm, 5 mm) and shortening (2.5 mm, 5 mm) of the radial neck, were compared to the nominal length in six human upper extremity cadavers. Total varus-valgus laxity and ulnar rotation were recorded. We hypothesized that restoring the exact length of the radius is important to maintain normal kinematics in the elbow joint. Lengthening or shortening of more than 2.5 mm significantly changed elbow kinematics. Lengthening caused a significant decrease (p < 0.001) in varus-valgus laxity, with the ulna tracking in varus and external rotation. Shortening caused a significant increase in varus-valgus laxity (p < 0.001) and ulnar rotation (p < 0.001), with the ulna tracking in valgus and internal rotation. Our study suggests that a restoration of radial length is important and that axial understuffing or overstuffing the radiohumeral joint by 2.5 mm or more, will alter elbow kinematics.

Aged↗

3D reconstruction of the structure of a residual limb for customising the design of a prosthetic socket.

Aiming at overcoming the limitations of the plaster-casting method in traditional prosthetic socket fabrication, the idea of reconstructing the 3D models for bones and skin of the residual limb is proposed. Given the two-dimensional obtained image through CT scanning, using image processing and reverse engineering techniques, the 3D solid model of the residual limb can be successfully reconstructed. The new approach can reproduce both the internal and the external structure of the residual limb. It can moreover avoid making a positive mould by the way of manual modifications. In addition to this, it can provide a scientific basis for the individualization of prosthetic socket design.

Artificial Limbs↗

Modular transcutaneous functional electrical stimulation system.

A new multipurpose programmable transcutaneous electric stimulator, Compex Motion, was developed to allow users to design various custom-made neuroprostheses, neurological assessment devices, muscle exercise systems, and experimental setups for physiological studies. Compex Motion can generate any arbitrary stimulation sequence, which can be controlled or regulated in real-time using any external sensor or laboratory equipment. Compex Motion originated from the existing Compex 2 electric stimulator, manufactured by a Swiss based company, Compex SA. The Compex Motion stimulator represents a further evolution and expansion of the ETHZ-ParaCare functional electrical stimulation system. This stimulator provides all the advanced functional electrical stimulation (FES) application and control features and can be easily incorporated into any standard rehabilitation program. Compex Motion has successfully been applied as a neuroprosthesis for walking, reaching and grasping in more than 100 stroke and spinal cord injured patients. This system has also been used to strengthen muscles and to investigate muscle properties in able-bodied subjects. Compex Motion is a multipurpose FES system specially designed to promote sharing and exchanging of stimulation protocols, sensors, and user interfaces. To the best of our knowledge an FES system that has similar capabilities does not exist yet.

Adult↗

Reverse engineering in CAD model reconstruction of customized artificial joint.

In order to meet the requirements of customized artificial joint design, and to reduce the production cycle and cost, we present a method to generate the complex surface of an artificial knee joint by co-ordinate measuring machine (CMM) from the normative prosthesis, and form the model data base. First, this paper describes how to plan the measure method to get the better data points and how to deal with the point cloud data. Then, the free-form surfaces are constructed from the point cloud data using the reverse engineering software-Surfacer. Lastly, the solid CAD model of the artificial knee joint is created from the surfaces by extension, intersection and so on. These models formed the data base of the prosthesis, in which we can select a suitable kind of artificial knee joint model to customize for the patient. That is, we only need to change the local data of the corresponding CAD model to meet the different requirements of the patient.

Computer Simulation↗

Anatomic considerations for the choice of surgical approach for hip resurfacing arthroplasty.

A number of surgical exposures have been advocated over the past 20 years by the pioneers of resurfacing hip arthroplasty and include the anterior, anterolateral, lateral, and posterolateral approaches. Not all of these approaches, however, appear to provide adequate exposure while respecting the local biology that seems to be imperative for the procedure. Based on an anatomic study, the most "bio-logical" surgical approach for hip resurfacing arthroplasty appears to be through a lateral or posterolateral approach using a digastric trochanteric osteotomy combined with an anterior hip dislocation. These exposures avoid injury to the medial femoral circumflex artery supplying the femoral head and allow access and treatment to the commonly observed hip pathologies that are frequently located anteriorly.

Adult↗

Revision ossiculoplasty.

Although ossiculoplasty, also known as ossicular chain reconstruction (OCR), was attempted initially in the early 1900s, it was not until the 1950s that it became commonplace and relatively well understood. Since then, there have been numerous technologic advances and a gain in the understanding of ossiculoplasty. However, successful OCR with resulting long-term stability can be a daunting task. Typically, the most common condition requiring revision OCR is chronic suppurative otitis media (COM) with or without cholesteatoma. Primary and revision OCR are performed also for blunt and penetrating trauma-induced conductive hearing loss, congenital defects (eg, atresia), and benign and malignant tumors. Typically, reconstruction in ears with COM is more difficult than in ears without infection. This article discusses the key factors involved in successful revision OCR.

Ear Diseases↗

Postoperative management of lower extremity amputations.

Postoperative management of the lower extremity amputation continues to evolve as a crucial first step in amputee rehabilitation. Although the major goals of early rehabilitation remain fairly constant, external forces continually pressure the rehabilitation team to complete these goals within shorter time frames. The atmosphere of rapid rehabilitation for amputees stresses return to normal function as quickly as possible. Early ambulation is the obvious goal for most new amputees.

Amputation, Surgical↗

Effect of multi-adhesive layering on retention of extraoral maxillofacial silicone prostheses in vivo.

STATEMENT OF PROBLEM: Loss of retention of maxillofacial prostheses often makes the margin visible or the prosthesis dislodge. Using several medical adhesives in combination may improve retention. PURPOSE: The purpose of this study was to investigate the effect of single- and multi-adhesive layering of 2 adhesives on the retention of maxillofacial silicone elastomer strips adhered to the skin of human forearms using a peel test. MATERIAL AND METHODS: Power analysis from a previous study and a pilot trial specified at least 20 subjects. Eight Silastic Adhesive A/MDX4-4210 silicone rubber strips (N=240) were applied in a predetermined random order to the left and right ventral forearms of 30 IRB-approved human subjects. Skin-Prep Protective Dressing was applied. Secure 2 Medical Adhesive (SMA) and Epithane-3 (E3) adhesive were used alone or as SMA/E3 or E3/SMA sandwiches (from skin to prosthesis) to adhere strips. Strips were peeled 6 hours later in a universal testing machine at 10 cm/min and data reported in N/m. Paired t tests were used to evaluate left and right arm differences. A Friedman test for nonparametric correlated data with within-subject design was performed, determining differences between both adhesives singly and in combination (alpha=.05). RESULTS: Tests of left-right differences were insignificant ( P =0.43), so the data from both arms were combined. Many strips with E3 did not adhere before testing and were counted as 0 adhesion. Median peel strengths (and 25th and 75th percentiles) in N/m were: SMA = 76.1 (47.1-107), E3 = 6.75 (0.0-25.9), SMA/E3 = 107 (78.0-132), and E3/SMA= 19.6 (6.99-42.4). All 4 variables were significantly different ( P <.0005). CONCLUSION: The multi-adhesive combination of SMA/E3 had the highest adhesion, followed, in order, by SMA alone, E3/ SMA, and E3 alone. Both E3 groups left a difficult-to-remove residue on the skin. SMA/E3 left a halo-like residue on the skin at the periphery of the strips from the E3 leaking around the SMA. SMA remained adherent to the prosthetic material.

Adhesives↗