Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Porosity”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

Compression shear strength and tableting behavior of microcrystalline cellulose agglomerates modulated by a solution binder (polyethylene glycol).

PURPOSE: To investigate the possibility of modulating the compression shear strength of agglomerates by the incorporation of a solution binder and to study the subsequent effect on the deformation behavior and tablet forming ability of the agglomerates. METHOD: Various concentrations (0.5 to 10%) of polyethylene glycol were incorporated as a solution binder into microcrystalline cellulose agglomerates of different porosity (10 and 20%) and the shear strength of the agglomerates, as evaluated by the 1/b value of the Kawakita equation, and the permeability to air and tensile strength of tablets formed from them were determined. RESULTS: Increased agglomerate porosity and concentration of polyethylene glycol reduced the 1/b values, which led to the formation of tablets with a lower permeability. A decreased tablet permeability corresponded to an increased tablet tensile strength except that the highest binder content was associated with a drop in the tablet tensile strength. CONCLUSIONS: The solution binder reduced the agglomerate shear strength, which was expressed as an increased degree of agglomerate deformation during compression. The latter seemed to be controlled by both agglomerate porosity and shear strength. The main role of the solution binder in improving the agglomerate compactability was to increase the degree of deformation of agglomerates during compression.

Cellulose↗

Nonstoichiometric hydroxyapatite granules for orthopaedic applications.

A new method for the preparation of nonstoichiometric hydroxyapatite (HA) "dense" and porous granules, round in form and up to 8 mm in sizes designed for application in orthopaedic surgery has been developed. The "dense" granules' porosity was up to 32% and they only contained micropores. They differed from that kind of granules by increased values of compression strength (up to 48 MPa). The porous granules contained a system of interconnected micro- and macropores. The porosity value (up to 70%) and the porosity structure were similar to those in the mineral framework of a spongy bone. The compression strength of the porous granules (up to 25 MPa) was high enough for various kinds of application. Granules of both sorts were used in performing 42 operations on the locomotor system. Depending upon localization and supposed level of the injured area loading, "dense" or porous granules were used. The postoperative observations (up to four years in length) have attested to the high quality of the granules.

Adolescent↗

Toughening of nanoporous glasses using porogen residuals.

Nanoporous glasses are inherently brittle materials that become increasingly fragile with increasing porosity. We show that remarkable increases in fracture energy can be obtained from remnants of the porogen molecules used to create the nanoscale pores. The interfacial fracture energy of approximately 2.6 J m(-2) for dense methylsilsesquioxane glass films is shown to increase by over one order of magnitude to >30 J m(-2) for glasses containing 50 vol.% porosity. The increased fracture resistance is related to a powerful molecular-bridging mechanism that was modelled using bridging mechanics. The study demonstrates that significant increases in interfacial fracture energy may be obtained using strategies involving controlled decomposition of the porogen molecule during processing of nanoporous glasses. The implications are important for a range of emerging optical, electronic and biological technologies that use nanoporous thin films, but are limited by the degradation of mechanical properties with increasing porosity.

Biotechnology↗

Effect of process parameters on the characteristics of porous calcium phosphate ceramics for bone tissue scaffolds.

Porous hydroxyapatite (HA) has already been widely used as a bone substitute due to its similarity with the mineral part of the bone. In this work, cylindrical tablets with micro and macro porosity were produced from stoichiometric and deficient hydroxyapatites by using naphthalene as porosifier agent. The influence of the processing parameters such as Ca/P ratio of start material, calcination temperature, and naphthalene content on the characteristics of porous calcium phosphate tablets was evaluated. Three mineral phases-HA, alpha-TCP (alpha tri-calcium phosphate), and beta-TCP (beta tricalcium phos-phate)-with variable contents were identified by x-ray diffraction (XRD) and Fourier-transformed infrared spectroscopy (FT-IR). Image analysis and density measurements were used to characterize sample porosity. As expected, the total porosity of the calcinated material is not dependent on the stoichiometry of the precursor hydroxyapatite. For calcium-deficient hydroxyapatite, the increase in naphthalene content contributes to stabilize alpha-TCP phase, altering the relative phases content.

Calcium Phosphates↗

Comparison of the substrate effect on VOC emissions from water based varnish and latex paint.

BACKGROUND, AIMS AND SCOPE: The building materials are recognised to be major contributors to indoor air contamination by volatile organic compounds (VOCs). The improvement of the quality of the environment within buildings is a topic of increasing research and public interest. Legislation in preparation by the European Commission may induce, in the near future, European Union Member States to solicit the industries of paints, varnishes and flooring materials for taking measures, in order to reduce the VOC emissions resulting from the use of their products. Therefore, product characterisation and information about the influence of environmental parameters on the VOC emissions are fundamental for providing the basic scientific information required to allow architects, engineers, builders, and building owners to provide a healthy environment for building occupants. On the other hand, the producers of coating building materials require this information to introduce technological alterations, when necessary, in order to improve the ecological quality of their products, and to make them more competitive. Studies of VOC emissions from wet materials, like paints and varnishes, have usually been conducted after applying the material on inert substrates, due to its non-adsorption and non-porosity properties. However, in real indoor environments, these materials are applied on substrates of a different nature. One aim of this work was to study, for the first time, the VOC emissions from a latex paint applied on concrete. The influence of the substrate (uncoated cork parquet, eucalyptus parquet without finishing and pine parquet with finishing) on the emissions of VOC from a water-based varnish was also studied. For comparison purposes, polyester film (an inert substrate) was used for both wet materials. METHODS: The specific emission rates of the major VOCs were monitored for the first 72 h of material exposure in the atmosphere of a standardized test chamber. The air samples were collected on Tenax TA and analysed using thermal desorption online with gas chromatography provided with both mass selective detection and flame ionisation detection. A double exponential model was applied to the VOC concentrations as a function of time to facilitate the interpretation of the results. RESULTS AND DISCUSSION: The varnish, which was introduced in the test chamber 23 h after the application of the last layer of material, emitted mainly glycolethers. Only primary VOCs were emitted, but their concentrations varied markedly with the nature of the substrate. The higher VOC concentrations were observed for the parquets of cork and eucalyptus, which indicated that they have a much higher porosity and, therefore, a higher power of VOC adsorption than the finished pine parquet (and polyester film). The paint was introduced in the chamber just after its application. Only primary VOCs were emitted (esters, phthalates, glycolethers and white spirit) but some compounds, like 2-(2-butoxyethoxy)ethanol and diethylphthalate, were only observed for paint/polyester, which suggested that they were irreversibly adsorbed by the paint/concrete. Compared with the inert substrate, the rate of VOC emissions was lower for concrete in the wet-stage (first hours after the paint application) but slightly higher later (dry-stage) as a consequence of desorption. CONCLUSIONS: As to varnish, the substrates without finishing, like cork and eucalyptus parquets, displayed a higher power of adsorption of VOCs than the pine parquet with finishing, probably because they have a higher porosity. As concerns paint, the total masses of VOCs emitted were lower for concrete than for polyester, indicating that concrete reduces the global VOC emissions from the latex paint. Concrete is seen to have a strong power of adsorption of VOCs. Some compounds, namely 2-(2-butoxyethoxy)ethanol, diethylphthalate and TEXANOL (this partially), were either irreversibly adsorbed by the concrete or desorbed very slowly (at undetected levels). A similar behaviour had not been reported for gypsum board, a paint substrate studied before. RECOMMENDATIONS AND OUTLOOK: The present data suggest that concrete may be a recommendable substrate for paint in an indoor environment. As the nature of the substrate conditions the rate and nature of VOC emissions from wet materials, it must be explicit when emissions from composite materials are reported, in order to allow comparisons and labelling of the product in terms of indoor air quality.

Air Pollution, Indoor↗

Effect of various formulation parameters on the properties of polymeric nanoparticles prepared by multiple emulsion method.

This work evaluates and interprets underlying mechanisms behind various aspects related to preparation and physical characteristics of polymeric nanoparticles (NP). These were prepared from different biodegradable polymers according to a water-in-oil-in-water emulsion solvent evaporation method. Polymers used were poly(lactic-co-glycolic) acid (PLGA), poly (lactic acid) (PLA), (PLA-PEG-PLA) triblock and (PLA-PEG-PLA)n multi-block co-polymers. A model DNA, as an example of a hydrophilic drug, was encapsulated in the internal aqueous phase. The primary emulsion was prepared using a high shear turbine mixer. The secondary emulsion was prepared by high-pressure homogenization. Surface morphology and internal structure were characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM). Influence of process variables on the physical properties of NP has been studied. Release of DNA was evaluated. In addition, changes occurring to NP porosity and surface area during degradation were followed. Nanoparticle size was ranging between 200-700 nm, according to the preparation conditions. Homogenizing pressure, concentration of the emulsifying agent used, polymer concentration and type and the concentration of a cryoprotectant had variable effects on NP size, surface area and porosity. Batches of NP where no emulsifying agent was added were obtained successfully. The release rate of the DNA from NP was mainly dependent on porosity, which varied significantly among used polymers. The preparation technique was efficient in encapsulating the model DNA and will be used for plasmid encapsulation in a future work.

Chemistry, Pharmaceutical↗

Full scale comparison of heterotrophic and nitrifying RBC biofilms.

Heterotrophic and nitrifying biofilms, from the secondary and tertiary full-scale Rotating Biological Contactor (RBC) wastewater treatment plants (WWTP) were investigated. Physical properties and structural features, such as, water content, organic portion (VS/TS), density, thickness, porosity, and fractal characteristics, including boundary/surface roughness, and Sierpinski and internal pore boundary fractals were examined. The results indicated that the heterotrophic biofilms were thicker and had higher porosity, larger internal voids, and faster growth and sloughing rates than the nitrifying biofilms. The nitrifying biofilms had much higher density(TS) and VS/TS ratio than the heterotrophic biofilms. In contrast to earlier results from laboratory scale studies, full-scale biofilms had structures and properties (porosity, density, and fractal dimensions) of more irregular spatial distribution.

Biofilms↗

Influence of different bioparticles on bed expansion characteristics of anaerobic fluidized bed reactors.

Bed expansion characteristics and predicting biofilm development and biomass hold-up in the anaerobic fluidized bed reactor were investigated. The treatability studies of brewery wastes were carried out in a pilot-scale fluidized bed reactor for a nine months period. The expansion and particle mixing characteristics of a fluidized bed containing different bioparticles is a complicated function of many variables, including hydrodynamics, support characteristics, and biofilm structures. The biological fluidized bed reactors have two types of bed expansion; the first is due to an increase of the superficial velocity and the second is due to the microbial growth in the bed. A new relationship for the porosity of the biological fluidized beds, was developed. Biofilm thickness and bed porosity increased rapidly in the upper part of the bed and the bioparticles become lighter than the clean particles with decreasing effective density. Most bioparticles in the anaerobic fluidized bed reactor (AFBR) were ellipsoidal and the geometric mean diameters were considered as the characteristic diameter. Their surface roughness causes an increase in the drag force acting on the particle. Thus, the expansion coefficient increased from 3.44 to 3.64 as terminal settling velocity decreased from 6.99 to 4.29 cm/s. An almost linear relationship was observed between local porosity and biofilm thickness. The differences between the measured and calculated biomass concentrations varied in the range of 0.4 and 12% (average 4.6%) considering the results from the pilot-scale AFBR. The bed expansion rate of the AFBR, varied from 12.3 to 18.3% whereas, the expansion rate of the clean bed also found between 7.9 and 12.7%. Consequently, the bed expansion rate due to biofilm accumulation on the particles can be well described to vary between 4.4 and 5.6%.

Bacteria, Anaerobic↗

Importance of the fraction of microcrystalline cellulose and spheronization speed on the properties of extruded pellets made from binary mixtures.

The aim of the study was to prove the importance of the binary mixture composition and spheronization speed on pellet properties. Extrudates from different binary mixtures of microcrystalline cellulose (MCC) and dicalcium phosphate dihydrate were prepared with a power-consumption-controlled extruder and spheronized at different speeds. The water content of the extrudate for the production of spherical pellets was evaluated. The pellets were characterized in terms of size, shape, porosity, mechanical properties, and disintegration. The fraction of MCC in the binary mixtures had the highest impact on the pellet properties. With an increasing fraction of MCC more water was required for successful pelletization, size and porosity of the pellets decreased, and the surface tensile stress increased. These observations were evaluated using the "sponge" and the "crystallite--gel" models for MCC. The latter led to the conception that an extrudate consists of two phases: a percolating crystallite--gel phase formed by MCC and water during extrusion and a filler phase formed by the second component of the binary mixture. This two-phase concept provides explanations for the extent of shrinking during drying and for the disintegration behavior. The spheronization speed had an influence on the size but not on porosity or surface tensile stress of the pellets. The best results were obtained at intermediate spheronization velocities of 10 and 13.4 m/sec. Fundamental properties of extrudates and pellets can be described by applying a two-phase concept of the crystallite--gel model.

Algorithms↗

Macroporosity and manure influence on atrazine transport through soil.

The influence of soil macro-porosity and manure on atrazine (6-chloro-N-ethyl-N'-(1-methylethyl)-1,3,5-triazine-2,4-diamine) transport was investigated under laboratory conditions using disturbed and undisturbed soil columns. The macro-porosity in the soil column was obtained with CT scanning technique. Liquid manure was applied at the surface of soil column, 19 cm long and 8 cm in diameter, at a rate of 60 m3/ha. Experimental results revealed that atrazine moves faster through the soils in the presence of manure compared to soil without application of manure. The average time for elusion and the relative peak concentration in the disturbed soil column without manure was 14.5 h and 3.1%, respectively compared to 11.0 h and 6.9% in the presence of manure, respectively. Similar behavior was observed in the case of disturbed soil columns. Soil macro-porosity has shown large impact on atrazine transport, especially in the presence of manure.

Atrazine↗

Effect of osteoblastic culture conditions on the structure of poly(DL-lactic-co-glycolic acid) foam scaffolds.

Poly(DL-lactic-co-glycolic acid) (PLGA) foams are an osteoconductive support that holds promise for the development of bone tissue in vitro and implantation into orthopedic defects. Because it is desirable that foams maintain their shape and size, we examined a variety of foams cultured in vitro with osteoblastic cells. Foams were prepared with different porosities and pore sizes by the method of solvent casting/porogen leaching using 80, 85, and 90 wt% NaCl sieved with particle sizes of 150-300 and 300-500 microm and characterized by mercury intrusion porosimetry. Foams seeded with cells were found to have volumes after 7 days in static culture that decreased with increasing porosity: the least porous exhibited no change in volume while the most porous foams decreased by 39 +/- 10%. In addition, a correlation was observed between decreasing foam volume after 7 days in culture and decreasing internal surface area of the foams prior to seeding. Furthermore, foams prepared with the 300-500 microm porogen had lower porosities, greater mean wall thicknesses between adjacent pores, and larger volumes after 7 days in culture than those prepared with the smaller porogen. Two culture conditions for maintaining cells, static and agitated (in a rotary vessel), were found to have similar influences on foam size, cell density, and osteoblastic function for 7 and 14 days in culture. Finally, we examined unseeded foams in aqueous solutions of pH 3.0, 5.0, and 7.4 and found no significant decrease in foam size with degradation. This study demonstrates that adherent osteoblastic cells may collapse very porous PLGA foams prepared by solvent casting/particulate leaching: a potentially undesirable property for repair of orthopedic defects.

Alkaline Phosphatase↗

New technique of seeding chondrocytes into microporous poly(L-lactide-co-epsilon-caprolactone) sponge by cyclic compression force-induced suction.

The initial requirement for a functional engineered cartilage tissue is the effective and reproducible seeding of chondrocytes into the interior of microporous scaffolds. High seeding efficiency, high cell viability, uniform cell distribution, and short operation time are also essential. We devised a new technique of seeding rabbit chondrocytes into microporous poly(L-lactide-co-epsilon-caprolactone) (PLCL) (porosity, 71- 80%; wall thickness, 2 and 6 mm) sponges under compression force-induced suction using a custom designed loading apparatus. Cell distribution and cell viability were determined using confocal laser scanning microscopy with fluorescent dye-staining techniques. Factors that affect the quality of a cell seeded construct were studied, namely, the porosity and thickness of sponges and suction cycles. Under 1 cycle of suction, an increase in porosity promoted cell seeding efficiency (CSE; defined as the percentage of the number of cells in the sponges relative to the initial number of cells seeded), cell viability (at 1 day post seeding), and a relatively uniform cell distribution, whereas thick sponges exhibited an inhomogeneous cell distribution irrespective of incubation time. Multiple cycles of suction of 5 and 10 at 0.1 Hz significantly improved the CSE, whereas high cell viability was maintained and even spatial cell distribution was achieved in 1 week. This study revealed that our newly developed cell seeding technique with multiple cycles of suction is a promising approach to inoculating cells into microporous sponges with high CSE, high cell viability, and homogeneous cell distribution.

Animals↗

Amsorb: a new carbon dioxide absorbent for use in anesthetic breathing systems.

BACKGROUND: This article describes a carbon dioxide absorbent for use in anesthesia. The absorbent consists of calcium hydroxide with a compatible humectant, namely, calcium chloride. The absorbent mixture does not contain sodium or potassium hydroxide but includes two setting agents (calcium sulphate and polyvinylpyrrolidine) to improve hardness and porosity. METHODS: The resultant mixture was formulated and subjected to standardized tests for hardness, porosity, and carbon dioxide absorption. Additionally, the new absorbent was exposed in vitro to sevoflurane, desflurane, isoflurane, and enflurane to determine whether these anesthetics were degraded to either compound A or carbon monoxide. The performance data and inertness of the absorbent were compared with two currently available brands of soda lime: Intersorb (Intersurgical Ltd., Berkshire, United Kingdom) and Dragersorb (Drager, Lubeck, Germany). RESULTS: The new carbon dioxide absorbent conformed to United States Pharmacopeia specifications in terms of carbon dioxide absorption, granule hardness, and porosity. When the new material was exposed to sevoflurane (2%) in oxygen at a flow rate of 1 l/min, concentrations of compound A did not increase above those found in the parent drug (1.3-3.3 ppm). In the same experiment, mean +/-SD concentrations of compound A (32.5 +/- 4.5 ppm) were observed when both traditional brands of soda lime were used. After dehydration of the traditional soda limes, immediate exposure to desflurane (60%), enflurane (2%), and isoflurane (2%) produced concentrations of carbon monoxide of 600.0 +/- 10.0 ppm, 580.0 +/- 9.8 ppm, and 620.0 +/-10.1 ppm, respectively. In contrast, concentrations of carbon monoxide were negligible (1-3 ppm) when the anhydrous new absorbent was exposed to the same anesthetics. CONCLUSIONS: The new material is an effective carbon dioxide absorbent and is chemically unreactive with sevoflurane, enflurane, isoflurane, and desflurane.

Absorption↗

Effect of increasing temperature on the properties of four bone cements.

This investigation uses a laboratory model to evaluate the effects of a heated femoral stem on the biomechanical properties of four common acrylic bone cements. American Society for Testing Materials dog bone shaped acrylic cement specimens made at four test temperatures, 0 degree C, 23 degrees C, 37 degrees C and 50 degrees C, were tested for modulus, ultimate tensile strength, fracture toughness, and percent porosity. Fatigue strength was tested in Simplex P at 23 degrees C and 37 degrees C. The data allow direct comparison among four cement brands at each of the four temperature conditions. No adverse changes of the mechanical properties were found for any cement at any temperature. Modulus, fracture toughness, and fatigue strength were unaffected by increased temperature. Ultimate tensile strength increased in Simplex P and Zimmer Osteobond but was unaffected for Zimmer Regular and Palacos R cements. Percent porosity was related to temperature changes inversely in all brands studied, except for Palacos R which consistently had low porosity, unaffected by temperature variation. Fatigue strength of Simplex P was unaffected by heating to 37 degrees C. Based on this laboratory model, heating of the femoral stem could save time without sacrificing mechanical properties of acrylic bone cement.

Biomechanical Phenomena↗

The clinical significance of vacuum mixing bone cement.

This controlled study compared the strength and porosity of 48 polymethylmethacrylate cement-implant constructs prepared with open bowl versus vacuum mix technique. Forty-eight blast finished stainless steel rods of 13 mm diameter were implanted with centralizers into 17-mm inner diameter tubes that had been retrograde filled with polymethylmethacrylate cement. The eight cement preparations used were open bowl and vacuum mixed Simplex, Osteobond, Zimmer Dough Type, or Palacos R. Six replications of each condition were performed. The tubes were maintained at 37 degrees C. Each tube was cut transversely into five segments. The center three segments were used for data analysis: pushout strength, cycles to failure, and interface porosity analysis. Rod pushout data showed there was no significant difference between open bowl and vacuum mixed samples when all cement brands were combined. Mean sheer force for Palacos R vacuum mixed samples was greater than open bowl (634+/-47 versus 423+/-171), whereas the force for the Zimmer Dough Type cement open bowl was greater than that of the vacuum mixed samples (901+/-71 versus 705 +/-82). Cycles to failure data did not show significant differences when open bowl and vacuum mixed samples were compared when cements were analyzed individually or combined. Image analysis of cement-implant interfaces showed that vacuum mixing reduced void area significantly compared with open bowl mixing in the Palacos R and Osteobond preparations. Vacuum mixing does not appear to reduce cement prosthesis interface porosity or improve its mechanical properties in all cements.

Analysis of Variance↗

A 1-year study of osteoinduction in hydroxyapatite-derived biomaterials in an adult sheep model: part I.

The study presented here investigated hydroxyapatite biomaterials implanted in soft-tissue sites in adult sheep to determine whether these materials are osteoinductive and whether the rate of osteoinduction can be increased by manipulating the composition and porosity of the implants. For the study, 16.8-mm x 5-mm discs were prepared from mixtures of hydroxyapatite and beta-tricalcium phosphate. Five mixtures of hydroxyapatite-ceramic and hydroxyapatite-cement paste forms were studied: 100 percent hydroxyapatite-ceramic (Interpore), 60 percent hydroxyapatite-ceramic, 100 percent hydroxyapatite-cement paste, 60 percent hydroxyapatite-cement paste, and 20 percent hydroxyapatite-cement paste. Biomaterials were implanted in subcutaneous and intramuscular soft-tissue pockets in 10 adult sheep. Cranial bone grafts of equal dimension were implanted as controls. One year after implantation, the volume of all biomaterials and bone grafts was determined from a computed tomographic scan, and porosity and bone formation were determined using backscatter electron microscopy. Cranial bone and the 20 percent hydroxyapatite-cement paste implants demonstrated significant volume reduction in all sites after 1 year (p < 0.001). No significant difference in volume of the remaining four biomaterials was found. There was no significant change in pore size in the ceramic implants (range, 200 to 300 micro) and in the cement-paste implants containing 60 percent hydroxyapatite or more (range, 3 to 5 nm). Pore size in the cement-paste implants containing 20 percent hydroxyapatite increased significantly with resorption of the tricalcium-phosphate component, reaching a maximum of 200 to 300 micro in the periphery, where the greatest tricalcium-phosphate resorption had occurred. Both ceramic biomaterials demonstrated lamellar bone deposition within well-formed haversian systems through the entire depth of the implants, ranging from a mean of 6.6 percent to 11.7 percent. There was minimal bone formation in the cement-paste implants containing 60 percent hydroxyapatite or more. In contrast, cement-paste implants containing 20 percent hydroxyapatite demonstrated up to 10 percent bone replacement, which was greatest in the periphery of the implants where the greatest tricalcium-phosphate resorption had occurred. This study confirms the occurrence of true osteoinduction within hydroxyapatite-derived biomaterials, when examined using backscatter techniques. In this study, the rate of osteoinduction was greatest when a porous architecture was maintained, which was best achieved in ceramic rather than cement-paste forms of hydroxyapatite. Porosity and resultant bone formation in cement-paste implants can be improved by combining hydroxyapatite with a rapidly resorbing component, such as tricalcium phosphate.

Animals↗

Statistical geometry of pores and statistics of porous nanofibrous assemblies.

The application of theoretical models to describe the structure of the types of fibrous network produced by the electrospinning of polymers for use in tissue engineering and a number of other applications is presented. Emphasis is placed on formal analyses of the pore size distribution and porosities that one would encounter with such structures and the nature of their relationships with other structural characteristics likely to be important for the performance of nanofibrous materials. The theoretical structures considered result from interactions between randomly placed straight rods that represent fibres with nanoscale dimensions. The dominant role of fibre diameter in controlling the pore diameter of the networks is shown and we discuss the perhaps counter-intuitive finding that at a given network mass per unit area and porosity, increasing fibre diameter results in an increase in mean pore radius. Larger pores may be required for ingrowth of cells to nanofibrous networks, hence this study clarifies that simply making the diameters of the fibres smaller might not be the way to improve cell proliferation on such substrates. An extensive review of structural features of the network such as the distribution of mass, inter-fibre contacts and available surface for cell attachment, fibre contact distributions for integrity of the networks and the porosity and pore size distributions is given, with emphasis placed on nanofibre dimensions for the first time.

Computer Simulation↗

An evaluation of microwave-polymerized resin bases for removable partial dentures.

PURPOSE: The hardness, porosity, and adaptation of removable partial dentures fabricated with one heat-polymerized denture base resin and two resins designed for microwave polymerization were evaluated. MATERIALS AND METHODS: Five prostheses were evaluated for each resin. Adaptation of the denture bases to the master cast was evaluated by spatial orientation and mean weight of residual impression material. The prostheses were than embedded in epoxy resin and sectioned for evaluation of resin hardness (Knoop hardness) and microporosity. RESULTS: There were no significant differences in the adaptation of the acrylic resin bases for Acron MC and Ch Lucitone. There was no significant difference in the mean Knoop hardness values for any of the resin bases near and away from the metal. None of the denture bases showed porosity greater than 100 microns. CONCLUSIONS: Both resin bases formulated for microwave polymerization were effectively polymerized around metal frameworks without adverse effects on resin hardness or porosity. Justi Denture Base material had poorer base adaptation than the other two resins.

Acrylic Resins↗