Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Polyethylene”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

Monitoring the effects of atmospheric ethylene near polyethylene manufacturing plants with two sensitive plant species.

Data of a multi-year (1977-1983) biomonitoring programme with marigold and petunia around polyethylene manufacturing plants was analysed to assess plant responses to atmospheric ethylene and to determine the area at risk for the phytotoxic effects of this pollutant. In both species, flower formation and growth were severely reduced close to the emission sources and plant performance improved with increasing distance. Plants exposed near the border of the research area had more flowers than the unexposed control while their growth was normal. Measurements of ethylene concentrations at a border site revealed that the growing season mean was 61.5 g m(-3) in 1982 and 15.6 g m(-3) in 1983. In terms of number of flowers, petunia was more sensitive than marigold and adverse effects were observed within ca. 400 m distance from the sources for marigold and within ca. 460 m for petunia. The area at risk (ca. 870 m) for ethylene-induced growth reduction was also limited to the industrial zone. Plants were more sensitive to ethylene in terms of growth reduction than in terms of inhibition of flowering. In the Netherlands, maximum permissible levels of ethylene are currently based on information from laboratory and greenhouse studies. Our results indicate that these levels are rather conservative in protecting field-grown plants against ethylene-induced injury near polyethylene manufacturing plants.

Air Pollutants↗

Colloid osmotic properties of modified hemoglobins: chemically cross-linked versus polyethylene glycol surface-conjugated.

Colloid osmotic pressures of hemoglobin solutions containing unmodified, intramolecularly cross-linked, intermolecularly polymerized, or polyethylene glycol (PEG) surface-conjugated hemoglobin have been measured to determine their macromolecular solution properties. Tetrameric and polymeric hemoglobins show nearly ideal solution behavior: whereas, hemoglobins conjugated to PEG have significantly higher colloid osmotic activity and exhibit solution non-ideality. From these studies, the average calculated molecular weights are 65.300 +/- 3500 for unmodified and intramolecularly cross-linked hemoglobin tetramers, 156,000 for ring-opened raffinose polymerized human hemoglobin, 97,000 for pyridoxalated human hemoglobin conjugated to a carboxy-PEG polymer, and 117,000 for bovine hemoglobin conjugated to a methoxy-PEG polymer. The calculated radius of gyration for tetrameric hemoglobins is 2.9 +/- 0.2 nm compared to 4.9 nm for the polymerized hemoglobin, and 7.2 and 14.1 nm for the human and bovine PEG-conjugated hemoglobins, respectively. Exclusion volumes are calculated to be 823 +/- 148 nm3 for tetramers, 4000 nm3 for polymers, and 13,000 nm3 and 94,000 nm3 for human and bovine PEG-conjugated hemoglobins, respectively. These studies show that polyethylene glycol conjugated to surface amino groups greatly increases the effective macromolecular size of hemoglobin in solution.

Animals↗

The effect of co-spray drying with polyethylene glycol 4000 on the crystallinity and physical form of lactose.

The effect of spray drying lactose alone and in the presence of polyethylene glycol 4000 was investigated. Lactose was added to distilled water to give concentrations of 10, 20, 30 and 40g/100ml at room temperature and each spray dried in turn. Identical samples were prepared to which polyethylene glycol (PEG) 4000 was added (12% by weight of lactose) prior to spray drying. Microcalorimetric and X-ray diffraction studies showed that spray drying lactose solutions produced completely amorphous material due to rapid solidification during the spray drying process, whereas lactose suspensions yielded partially crystalline products due to crystalline material that remained in suspension. However, all the PEG/lactose (12%w/w) co-spray dried products were found to be crystalline. It can be inferred that the solidification rates of the lactose in the presence of PEG must have been slower than that of lactose alone which allowed PEG and lactose to crystallize. The PEG/lactose products that were spray dried from solution consisted of alpha-anhydrous, alpha-monohydrate, beta-lactose and PEG extended chain polymorph, whereas those formed from suspension PEG/lactose samples consisted of only alpha-anhydrous, alpha-monohydrate and extended chain PEG crystals. PEG probably caused the more concentrated lactose suspensions to crystallize slowly due to the strong hydrogen bonding between PEG and water, which allowed growth on the alpha-lactose seed crystals.

Calorimetry, Differential Scanning↗

Compatibility of paclitaxel in 5% glucose solution with ECOFLAC low-density polyethylene containers-stability under different storage conditions.

The compatibility of paclitaxel with low-density polyethylene containers (ECOFLAC) was studied under different temperature and light conditions. Solutions of 0.4 and 1.2 mg/ml of paclitaxel in 5% glucose solution were prepared, put into ECOFLAC containers and stored: (i) at ambient temperature (20-25 degrees C) and in ambient light; (ii) at ambient temperature in the dark; and (iii) at +4 degrees C in the dark. Paclitaxel was assayed by high-performance liquid chromatography after visual inspection of the solutions. The results show that solutions of TAXOL in 5% glucose should not be stored for more than 5 days in glass or ECOFLAC containers because a whitish precipitate tends to form, lowering the paclitaxel concentration. The decrease in the paclitaxel concentration observed after chromatographic analysis ranged very widely (from 12 to 83% of the initial concentration). However solutions of TAXOL diluted in 5% glucose was stable for 5 days in ECOFLAC containers under all the storage conditions tested. These additive-free low-density polyethylene containers offer the advantage of not releasing DEHP into the paclitaxel solutions.

Chemical Precipitation↗

Vacuum metal deposition: factors affecting normal and reverse development of latent fingerprints on polyethylene substrates.

Vacuum metal deposition (VMD) is an established technique for the development of latent fingerprints on non-porous surfaces. VMD has advantages over cyanoacrylate fuming, especially in circumstances where prints are old, have been exposed to adverse environmental conditions, or are present on semi-porous surfaces. Under normal circumstances, VMD produces 'negative' prints as zinc deposits onto the background substrate and not the print ridges themselves. A phenomenon of 'reverse' development, when zinc deposits onto the print ridges and not the background, has been reported by many authors but its causes have not been conclusively identified. Four plastic substrates were used in this study and these could be easily divided into two groups based on the types of development observed as the amount of deposited gold was increased. On group I plastics, identified as low-density polyethylene (LDPE), normal development then reverse development and finally no development resulted with increasing gold. On group II plastics, identified as high-density polyethylene (HDPE), normal development then over-development and finally poor-quality normal development resulted with increasing gold. Our results suggest that the difference between these plastic types causes variations in the gold film structure which in turn dictates the nature of the zinc deposition. On group I plastics, the structure and thickness of the gold film has been identified as the critical factor in the occurrence of normal or reverse development. Thin gold films on plastic substrates form small 'clusters' (or agglomerates) rather than the atoms being uniformly spread over the surface. The size and shape of these clusters is critical. Once the clusters reach a certain morphology, they no longer act as nucleation sites for zinc, and hence, zinc will not deposit onto the substrate. On group II plastics, results suggest that the gold clusters are smaller and more densely packed. Hence, even though the same amount of gold has been deposited, the gold clusters in this case do not reach the critical morphology and so continue to act as nucleation sites for zinc.Typically, zinc will not deposit onto the fingerprint ridges as the gold nucleation sites are buried within the print residue. However, when more gold is deposited, gold emerges at the surface of the latent print allowing zinc deposition onto the ridges. The rate of gold evaporation was found not to affect the structure of the gold film, although a slower rate of evaporation resulted in more effective deposition.

Dermatoglyphics↗

Modelling of conditions for the enantiomeric separation of beta2-adrenergic sympathicomimetics by capillary electrophoresis using cyclodextrins as chiral selectors in a polyethylene glycol gel.

A two-factor central composite design was used to determine a mathematical model for prediction of the optimal conditions for the separation of the enantiomers of some widely used beta2-sympathicomimetic drugs (beta2-agonists) by capillary electrophoresis using cyclodextrins (CD) as a chiral selector in a polyethylene glycolgel. The effects of the chemical structure of these drugs along with the addition of polyethylene glycol to the cyclodextrin solution on the resolution of their enantiomers were studied. To allow impurity studies down to 0.1% (distomer eutomer) a resolution of 2.5 should be warranted. Those beta2-agonists containing two hydroxylic groups in the aromatic ring structure show the highest enantiomeric separation, due to the fact that one of their enantiomers has a better geometric structure to fit into the beta-cyclodextrin cavity.

Adrenergic beta-2 Receptor Agonists↗

Differential apoptotic response of J774 macrophages to alumina and ultra-high-molecular-weight polyethylene particles.

We recently identified apoptosis in in vitro wear particle-stimulated macrophages. The recent explosion of interest in apoptosis lies in the fact that it is under positive and negative regulation through evolutionary conserved biochemical pathways. It may also be possible to modulate macrophage apoptosis in the treatment of periprosthetic osteolysis. The purpose of this study was to compare the macrophage response to identically sized particles of alumina ceramic (Al2O3) and ultra-high-molecular-weight polyethylene (UHMWPE) in terms of TNF-alpha release and induction of apoptosis. J774 mouse macrophages were incubated for 0-24 h in the presence of Al2O3 and UHMWPE particles. TNF-alpha release was measured by ELISA; Poly(ADP-ribose)polymerase (PARP) and caspase-3 expression was analyzed by Western blot; DNA fragmentation (DNA laddering) was visualized on agarose gel containing ethidium bromide. Al2O3 particles induced TNF-alpha release after 4 h incubation with concentrations reaching 483 and 800 pg/ml after 24 h with 125 and 250 particles/macrophage, respectively (control = 161 pg/ml) (P < 0.05 vs. control). The same concentrations of UHMWPE particles induced a much larger and significant TNF-alpha release after only 1 h incubation, increasing up to 6250 pg/ml after 24 h (P < 0.05 vs. control). Western blot analysis demonstrated that the active caspase-3 fragment (17 kDa) and the proteolytic PARP fragment (85 kDa) were expressed after 2 h incubation with 125 and 250 Al2O3 particles/macrophage. The active caspase-3 and the PARP fragment had lower expression and appeared after a longer incubation time (8 h) with 125 and 250 UHMWPE particles/macrophage. Finally, DNA fragmentation (DNA laddering) was observed after 16 h with 125 and 250 particles of Al2O3 per macrophage whereas no laddering was induced by UHMWPE particles even after 24 h incubation. This study shows that although both Al2O3 and UHMWPE particles induce TNF-alpha release, this stimulation was much greater (8-10 times higher) with UHMWPE than Al2O3 (P < 0.05 vs. control). As well, the induction of apoptosis, as measured by activation of caspase-3, PARP cleavage and DNA laddering, is different for these two particles, being faster and more important with Al2O3 than UHMWPE. We hypothesize that the ability of Al2O3 to induce macrophage apoptosis may explain the lower TNF-alpha release observed with these particles and explain the differences seen in osteolysis patterns of ceramic-ceramic (CC) vs. metal-polyethylene (Mpe) articulations. In conclusion, apoptosis may be a major internal mechanism to decrease macrophage activity and may be a desired therapeutic endpoint. The identification of an apoptosis-related pathway in the macrophage response to ceramic particles provides crucial data for a rational approach in the treatment and/or prevention of periprosthetic osteolysis.

Aluminum Oxide↗

Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model.

The purpose of this study was to develop and test a phantom model based on actual total hip replacement (THR) components to simulate the true penetration of the femoral head resulting from polyethylene wear. This model was used to study both the accuracy and the precision of radiostereometric analysis, RSA, in measuring wear. We also used this model to evaluate optimum tantalum bead configuration for this particular cup design when used in a clinical setting. A physical model of a total hip replacement (a phantom) was constructed which could simulate progressive, three-dimensional (3-D) penetration of the femoral head into the polyethylene component of a THR. Using a coordinate measuring machine (CMM) the positioning of the femoral head using the phantom was measured to be accurate to within 7 microm. The accuracy and precision of an RSA analysis system was determined from five repeat examinations of the phantom using various experimental set-ups of the phantom. The accuracy of the radiostereometric analysis, in this optimal experimental set-up studied was 33 microm for the medial direction, 22 microm for the superior direction, 86 microm for the posterior direction and 55 microm for the resultant 3-D vector length. The corresponding precision at the 95% confidence interval of the test results for repositioning the phantom five times, measured 8.4 microm for the medial direction, 5.5 microm for the superior direction, 16.0 microm for the posterior direction, and 13.5 microm for the resultant 3-D vector length. This in vitro model is proposed as a useful tool for developing a standard for the evaluation of radiostereometric and other radiographic methods used to measure in vivo wear.

Arthroplasty, Replacement, Hip↗

Polyethylene and methyl methacrylate particle-stimulated inflammatory tissue and macrophages up-regulate bone resorption in a murine neonatal calvaria in vitro organ system.

There is considerable evidence that orthopaedic wear debris plays a crucial role in the pathology of aseptic loosening of joint prostheses. This study examined the effect of inflammatory membranes stimulated with methyl methacrylate and polyethylene on bone resorption, using the murine air pouch model. The capacity of RAW 264.7 mouse macrophages exposed to polymer particles to produce factors affecting bone metabolism was also studied. Neonatal calvaria bones were co-cultured with either pouch membranes or conditioned media from activated macrophages. Bone resorption was measured by the release of calcium from cultured bones, and the activity of tartrate-resistant acid phosphatase in both bone sections and culture medium was also assayed. Results showed that inflammatory pouch membrane activated by methyl methacrylate and polyethylene enhanced osteoclastic bone resorption. Conditioned media from particles stimulated mouse macrophages also stimulated bone resorption, although this effect was weaker than resorption induced by inflammatory pouch membranes. The addition of the particles directly into the medium of cultured calvaria bones had little effect on bone resorption. Our observations indicate that both inflammatory tissue and macrophages provoked by particles can stimulate bone resorption in cultured mouse neonatal calvaria bones. This simple in vitro bone resorption system allows us to investigate the fundamental cellular and molecular mechanism of wear debris induced bone resorption and to screen potential therapeutic approaches for aseptic loosening.

Animals↗

Fluordeoxyglucose positron emission tomography detection of inflammatory reactions due to polyethylene wear in total hip arthroplasty.

A patient experienced chronic pain 8 years after total hip arthroplasty. Radiology and bone scanning showed no signs of aseptic loosening, but fluorine-18 fluorodeoxyglucose positron-emission tomography ((18)F-FDG-PET) showed intensive glucose metabolism in the joint capsule and around the prosthesis neck. The surgical intervention revealed soft tissue reaction in this area. Histologic examination showed a granulomatous foreign body reaction against polyethylene debris particles. Infection and rheumatoid arthritis could be excluded clinically, histologically, microbiologically, and with the bone scan. Therefore, FDG-PET detected inflammatory reaction caused by polyethylene wear in total hip arthroplasty and allowed clinicians to decide on interventions, including removal of granulomatous tissue and the replacement of worn artificial joint components to prevent aseptic loosening.

Fluorodeoxyglucose F18↗

Fracture of the central polyethylene tibial spine in posterior stabilized total knee arthroplasty.

Between 1993 and 1998, 332 I-BII (Insall Burstein II) prostheses were implanted in our department. We studied 5 cases of tibial polyethylene spine fractures. The fractures occurred 3 to 5 years following the surgery. All cases with fractures had mild medial laxity that was noted on follow-up of 2 to 3 years following arthroplasty. One also developed mild hyperextension. All the patients had a revision surgery. In 2 cases, the polyethylene was changed to a thicker one, together with medial reinforcement. Three cases were revised to a rotating hinge prosthesis.

Aged↗

Optical analysis of surface changes on early retrievals of highly cross-linked and conventional polyethylene tibial inserts.

Retrieved tibial liners of highly cross-linked and conventional polyethylene were examined for articular and backside surface damage. Surfaces were graded for pitting, machine-mark loss, scratching, abrasion, delamination, and embedded debris. Whereas no difference existed in the damage score for the 2 groups, the highly crosslinked group showed significantly less elimination of machine marks. Wear, surface plastic deformation, or a combination, could account for the damage on these components. Only 1 of the highly crosslinked polyethylene inserts was available for destructive testing. That insert was melted to activate the shape memory, and thus differentiate, between wear versus plastic deformation. Nearly all changes on the articular and backside surfaces disappeared upon melting, and original machining marks reappeared, suggesting that the surface changes for that component were primarily the result of plastic deformation and not material removal.

Arthroplasty, Replacement, Knee↗

All-polyethylene and metal-backed tibial components in total knee arthroplasty: a matched pair analysis of functional outcome.

A group of 98 patients who had primary unilateral total knee arthroplasty (TKA) with cemented, posterior-stabilized knee implants for osteoarthritis were matched for age, diagnosis, weight, body mass index, and presence of comorbid conditions. The patients were followed up with clinical, radiographic, and outcome measures including SF-36 scales and patient outcome questionnaires. Forty-nine patients had all-polyethylene tibial implants (APT), and 49 patents had metal backed tibial implants (MBT) with similar knee implant design and articular geometry. There is no difference among these patient cohorts in the clinical performance or functional outcome of TKA using APT or MBT components in primary TKA at intermediate term follow-up. In consideration of concerns about polyethylene wear, osteolysis, and cost associated with MBT components, these findings may present an opportunity for quality improvement and cost savings with increased utilization of APT in TKA operations.

Aged↗

Spontaneous fracture of the ceramic ball in a ceramic-polyethylene total hip arthroplasty.

Fractures of the ceramic ball in total hip arthroplasty are an uncommon cause of arthroplasty failure, and reports of this complication in ceramic-on-polyethylene total hip arthroplasty articulations are rare. Ball fractures have been reported in patients who were overweight, had high levels of activity, or had been injured. Other postulated contributory factors have included small ball diameter, defects in ceramic quality or manufacture, and errors in implantation of the arthroplasty. A case of a ceramic ball fracture in a ceramic and polyethylene articulation is reported, and the literature on such fractures is reviewed.

Ceramics↗

Preliminary study of the effect of aging following irradiation on the wear of ultrahigh-molecular-weight polyethylene.

Several studies have indicated that degradation of ultrahigh-molecular-weight polyethylene following gamma irradiation in air adversely affects the mechanical properties of the material; however, it is not known how this subsequently affects its wear rate. Wear studies have therefore been performed on three groups of ultrahigh-molecular-weight polyethylene; unirradiated material, recently irradiated material (aged for 2 months), and aged irradiated material (aged for 5 years). The aging took place in sterile packaging on the shelf. The wear studies were carried out on a tri-pin-on-disk wear tester, with a pin from each type of material being studied in each test. In each test the wear rate of the nonirradiated material was slightly lower than the 2-month-aged, irradiated material. The 5-year-aged, irradiated material had the highest wear rate, and this was significantly greater than that of the unirradiated material (P < .05).

Acetabulum↗

Failure of uncemented polyethylene acetabular components.

The authors describe the mode of failure of the Ring UPM (Downs Brothers, Surrey, United Kingdom) uncemented metal-on-plastic total hip arthroplasty. Erosion of the external surface of the uncemented acetabular cup led to early loosening in eight cases. The subsequent production of large quantities of polyethylene debris caused massive granulomata, resulting in osteolysis of the acetabulum and femur. Revision surgery was difficult because of the loss of bone stock. The serious consequences of failure of this design lead to the conclusion that uncemented, nonmetal-backed polyethylene acetabular components should not be used.

Acetabulum↗

Polyethylene wear in total hip arthroplasty in patient-matched groups. A comparison of stainless steel, cobalt chrome, and titanium-bearing surfaces.

Osteolysis and component loosening secondary to polyethylene (PE) debris are of paramount concern to today's joint replacement surgeon. This retrospective clinical study measures linear wear in 568 implanted total hip prostheses in which three different metals were used as bearing surfaces (307 stainless steel T-28 [Zimmer, Warsaw, IN], 162 cobalt chrome Tr-28 [Zimmer], and 99 nonion implanted titanium Miami Orthopedic Surgical Consultants [Biomet, Warsaw, IN] prostheses) implanted by a single surgeon over an 8-year period. The acetabular component in all cases was nonmetal-backed compression-molded PE, and all components were cemented. Linear wear was measured using the radiographic technique described by Livermore et al. (The effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg 72A:518, 1990) in which change in acetabular component thickness is determined from serial radiographs. A separate evaluation of this technique confirmed accuracy to within 0.18 mm. Radiographs were also evaluated for femoral and acetabular radiolucencies, femoral subsidence, and osteolysis. Patients were matched for sex, age, weight, and length of follow-up period to eliminate these retrospective variables for comparison of wear. The patient-matched groups consisted of 77 patients from each group (43 women, 34 men) with the following demographics: age, 66 years; weight, 158.9 lbs.; follow-up period, 7.9 years. Results revealed linear wear rates of 0.06 stainless steel, 0.05 cobalt chrome, and 0.08 titanium in the patient-matched groups.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Polyethylene synovitis following canine total hip arthroplasty. Histomorphometric analysis.

The synovial membrane response to polyethylene wear debris was analyzed in canine total hip arthroplasties (THA). Fifty-four THAs were performed in healthy, mature dogs. None of the arthroplasties demonstrated clinical or radiographic signs of loosening. Synovial membrane biopsies were harvested 4 (n = 13), 6 (n = 5), 8 (n = 8), 12 (n = 15), and 24 (n = 6) months after surgery and were scored for inflammation, polyethylene (PE) wear debris, histiocyte density, and membrane thickness. The amount of PE wear debris tended to increase with time. However, the inflammatory changes within the joint capsule and synovial membrane did not progress, and the total thickness of the alveolar and surface layers decreased (P = .008). It appears that the amount of wear debris at 2 years in canine hip arthroplasties, without evidence of loosening, is well tolerated by the joint capsule.

Animals↗