Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Isotopes”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

Application of 2H NMR to the study of natural site-specific hydrogen isotope transfer among substrate, medium, and glycerol in glucose fermentation with yeast.

2H NMR is a very useful tool in isotope tracing studies. This technique was applied to a quantitative study of a site-specific deuterium affiliation among the substrate, the medium, and a product (glycerol), in glucose fermentation with yeast. The quality of the results depends on the quantitative 2H NMR analysis of glycerol. After comparing several potential analysis probe molecules, the derivative of glycerol, 2,2-dimethyl-1,3-dioxolane-4-methanol, was chosen as the most advantageous. Using this probe in a set of isotope-labeling experiments, we describe how a complete quantitative site-specific hydrogen isotope transfer model, which connects the site-specific isotopic ratios of the substrate, the medium, and the products, can be established. This model can provide information on complex hydrogen transfer mechanisms during biochemical reactions and can be useful for the prediction of site-specific hydrogen isotopic ratios at natural abundance of the products, based on that of the substrate or reactants and the medium.

Culture Media↗

Screening for pancreatic disease: A comparison of grey-scale ultrasonography and isotope scanning.

The efficiency of ultrasound in the diagnosis of pancreatic disease was compared prospectively with that of selenomethionine isotope scanning in 46 patients presenting with abdominal pain or weight-loss or with jaundice. Of 14 patients who later proved to have pancreatic carcinoma, all had an abnormal isotope scan and 13 had an abnormal ultrasound scan. Of 10 patients with chronic pancreatitis, all had an abnormal isotope scan and 9 had an abnormal ultrasound scan. The small advantage of selenomethionine was, however, offset by a higher false-positive rate: of 22 patients who proved not to have pancreatic disease, 13 had abnormal isotope scans compared with only 3 with ultrasound. Review of earlier experience with the two techniques yielded similar results: in pancreatic carcinoma and chronic pancreatitis, isotope scanning gave slightly fewer false-negative results than ultrasound but many more false-positives. Because of its lower false-positive rate, because it avoids ionising radiation, and because it can usually distinguish carcinoma from pancreatitis, ultrasound is the procedure of choice for initial investigation of patients with suspected pancreatic disease.

Chronic Disease↗

Isotope effects and intermediates in the reduction of NO by P450(NOR).

The mechanism of the heme-thiolate-dependent NADH-NO reductase (P450(NOR)) from Fusarium oxysporum was investigated by kinetic isotope effects including protio, [4S-2H]-, [4R-2H]-, [4,4(2)H(2)]-NADH and stopped-flow measurements. The respective kinetic isotope effects were measured at high NO concentrations and were found to be 1.7, 2.3 and 3.8 indicating a rate-limitation at the reduction step and a moderate stereoselectivity in binding of the cofactor NADH. In a different approach the kinetic isotope effects were determined directly for the reaction of the Fe(III)-NO complex with [4R-2H]- and [4S-2H]-NADH by stopped-flow spectroscopy. The resulting isotope effects were 2.7+/-0.4 for the R-form and 1.1+/-0.1 for the S-form. In addition the 444 nm intermediate could be chemically generated by addition of an ethanolic borohydride solution to the ferric-NO complex at -10 degrees C. In pulse radiolysis experiments a similar absorbing species could be observed when hydroxylamine radicals were generated in the presence of Fe (III) P450(NOR). Based on these results we postulate hydride transfer from NADH to the ferric P450-NO complex resulting in a ferric hydroxylamine-radical or ferryl hydroxylamine-complex and this step, as indicated by the kinetic isotope effects, to be rate-limiting at high concentrations of NO. However, at low concentrations of NO the decay of the 444 nm species becomes the rate-limiting step as envisaged by stopped-flow and optical kinetic measurements in a system in which NO was continuously generated. The last step in the catalytic cycle may proceed by a direct addition of the NO radical to the Fe-hydroxylamine complex or by electron transfer from the NO radical to the ferric-thiyl moiety in analogy to the postulated mechanisms of prostacyclin and thromboxane biosynthesis by the corresponding P450 enzymes. The latter process of electron transfer could then constitute a common step in all heme-thiolate catalyzed reactions.

Cytochrome P-450 Enzyme System↗

Isotopic modelling of the significance of bacterial sulphate reduction for phenol attenuation in a contaminated aquifer.

A Triassic sandstone aquifer polluted with a mixture of phenolic hydrocarbons has been investigated by means of high-resolution groundwater sampling. Samples taken at depth intervals of 1 m have revealed the presence of a diving pollutant plume with a sharply defined upper margin. Concentrations of pollutant phenols exceed 4 g/l in the plume core, rendering it sterile but towards the diluted upper margin evidence for bacterial sulphate reduction (BSR) has been obtained. Groundwaters have been analysed for both delta34S-SO4 and delta18O-SO4. Two reservoirs have been identified with distinct sulphate oxygen isotope ratios. Groundwater sulphate (delta18O-SO4 = 3-5/1000) outside the plume shows a simple linear mixing trend with an isotopically uniform pollutant sulphate reservoir (delta18O-SO4 = 10-12/1000) across the plume margin. The sulphur isotope ratios do not always obey a simple mixing relation, however, at one multilevel borehole, enrichment in 34SO4 at the plume margin is inversely correlated with sulphate concentration. This and the presence of 34S-depleted dissolved sulphide indicate that enrichment in 34SO4 is the result of bacterial sulphate reduction. Delta34S analysis of trace hydrogen sulphide within the plume yielded an isotope enrichment factor (epsilon) of -9.4/1000 for present-day bacterial sulphate reduction. This value agrees with a long-term estimate (-9.9/1000) obtained from a Rayleigh model of the sulphate reduction process. The model was also used to obtain an estimate of the pre-reduction sulphate concentration profile with depth. The difference between this and the present-day profiles then gave a mass balance for sulphate consumption. The organic carbon mineralisation that would account for this sulphate loss is shown to represent only 0.1/1000 of the phenol concentration in this region of the plume. Hence, the contribution of bacterial sulphate reduction to biodegradation has thus far been small. The highest total phenolic concentration (TPC) at which there is sulphur isotope evidence of bacterial sulphate reduction is 2000 mg/l. We suggest that above this concentration, the bactericidal properties of phenol render sulphate-reducing bacteria inactive. Dissolved sulphate trapped in the concentrated plume core will only be utilised by sulphate reducers when toxic phenols in the plume are diluted by dispersion during migration.

Biodegradation, Environmental↗

Origin and subsurface history of geothermal water of Murtazabad area, Pakistan--an isotopic evidence.

The Murtazabad area represents one of the major geothermal fields in Pakistan, with seven hot springs lying along the Main Karakoram Thrust. Discharge of the springs is 50-1200 l per minute with the surface temperature from 40 to 94 degrees C. Environmental isotopes and chemical concentrations have been used to investigate the origin and subsurface history of thermal water. Four sets of water samples were collected and analyzed for various isotopes including 18O, 2H and 3H of water; 34S and 18O of dissolved sulphates and chemical contents. Isotopic and chemical data show that the origin of thermal water is meteoric water. On the delta-diagram, delta18O and delta2H data plotting below the local meteoric water line with a slope around 12.3 show that the original thermal water receives recharge from precipitation at higher altitude (3000 m) and undergoes delta18O shift of about 1 per thousand due to exchange with rocks. Different correlations between isotopes, temperature and Cl indicate that the observed isotopic compositions have evolved due to mixing of different proportions of shallow water at different spring paths during movement of thermal water towards the surface. It is also inferred from the tritium data along with delta18O and delta2H that the circulation time is long and is estimated to be more than 50 years.

Journal Article↗

Evidences of precession and obliquity orbital forcing in oxygen-18 isotope composition of Montalbano Jonico section (Basilicata, southern Italy)

Quantitative signal processing methods have been applied to a delta(18)O profile for a land-based stratigraphic section, extending from the upper part of lower Pleistocene to the lower part of middle Pleistocene. The section is well exposed with a continuous succession of muds and muddy silts, about 400 m thick, located in the southernmost part of Bradano Trough, near Montalbano Jonico in Basilicata (south Italy). The sampled part of the section is about 240 m thick, in which a foram benthic species (Cassidulina carinata) is continuously available for oxygen isotope ratio measurements. The aim of the data treatment is to discover how much of the Earth's orbital periodic movements, precession and obliquity, which represent the dominant periodicities in paleoclimatic variations from the base of the Pleistocene until 0.735 Myr BP, are responsible for the oscillations observed in the oxygen-18 record of the Montalbano Jonico section. A time framework of the section was constructed on the basis of calcareous nannofossil biostratigraphic analyses, preliminary magnetostratigraphic results and oxygen isotope correlation with the record from DSDP s607 (isotope data collected in the NOAA World Data Center). The resulting time-scale extends from 1.15 to 0.74 Myr. Power spectrum analysis was performed on the isotope data to illuminate the most important periodicity components of the Montalbano Jonico record. The periodic components of 41,000 and 21,000 yr are present in this record; the former associated with periodic changes in the tilt of Earth's axis and the latter with periodic changes with the precession of the equinoxes, as predicted by the astronomical theory of ice ages. They are, however, not the most important components of the power spectrum, in which a lower frequency component contains most of the variance. This low-frequency component is centered at a period around 208,000 yr. This periodicity seems not to be attributable to any known astronomical or paleoclimatic phenomenon. An attempt was made to verify if this periodicity was due to the composite effect of precession and obliquity signals together at different frequencies from their forcing frequencies. In order to investigate this effect, isotope data have been parameterized in terms of a sum of simple functions of precession and obliquity signals with unknown coefficients. The coefficients are estimated from the time series with the assumption that the best coefficients are those which minimize the 'noise' i.e. the difference between the data function and the precession and obliquity functions. Cross-spectra analyses were also performed on the data and the precession signal and on the data and the obliquity signal. The power spectrum of the residual 'noise' functions and the cross-spectra demonstrate that precession and obliquity signals are not in phase with the data at their forcing frequencies and so damp. The precession and obliquity signals were then shifted towards lower frequencies at equally spaced lags, the resultant 'noise' power spectra were plotted for every combination of lags of precession and obliquity. The results of this data processing demonstrate that it is possible to have a combination of precession and obliquity cyclicities that could be responsible for the signal with 208 kyr periodicity.

Journal Article↗

Solvent extraction, ion chromatography, and mass spectrometry of molybdenum isotopes.

A procedure was developed that allows precise determination of molybdenum isotope abundances in natural samples. Purification of molybdenum was first achieved by solvent extraction using di(2-ethylhexyl) phosphate. Further separation of molybdenum from isobar nuclides was obtained by ion chromatography using AG1-X8 strongly basic anion exchanger. Finally, molybdenum isotopic composition was measured using a multiple collector inductively coupled plasma hexapole mass spectrometer. The abundances of molybdenum isotopes 92, 94, 95, 96, 97, 98, and 100 are 14.8428(510), 9.2498(157), 15.9303(133), 16.6787(37), 9.5534(83), 24.1346(394), and 9.6104(312) respectively, resulting in an atomic mass of 95.9304(45). After internal normalization for mass fractionation, no variation of the molybdenum isotopic composition is observed among terrestrial samples within a relative precision on the order of 0.00001-0.0001. This demonstrates the reliability of the method, which can be applied to searching for possible isotopic anomalies and mass fractionation.

Journal Article↗

Sources of uncertainty in isotope ratio measurements by inductively coupled plasma mass spectrometry.

A model is presented describing the effects of dead time and mass bias correction factor uncertainties, flicker noise, and counting statistics on isotope ratio measurement precision using inductively coupled plasma mass spectrometry (ICPMS) with a single collector. Noise spectral analysis is exploited to enable estimation of the flicker noise parameters. For the instrument used, the flicker noise component exhibited a fairly weak frequency (t) dependence (is proportional to f -0.33+/-0.12), but was directly proportional to the total number of counts, Q. As white noise, determined by counting statistics, is given by Q0.5, the isotope ratio measurement uncertainties will actually cease to improve when Q exceeds a certain threshold. This would suggest that flicker noise could become the limiting factor for the precision with which isotope ratios can be determined by ICPMS. However, under most experimental conditions, uncertainties associated with mass discrimination and dead time correction factors are decisive. For ratios up to approximately 22 (115In/113In), optimum major isotope count rates are generally below 0.3 MHz, for which precision in the mass discrimination factor is limiting. The model derived could be used as a starting point for determining optimum conditions and understanding the limitations of single-collector ICPMS for precise isotope ratio measurements.

Journal Article↗

Sulfur and oxygen isotope analysis of sulfate at micromole levels using a pyrolysis technique in a continuous flow system.

The discovery of a mass-independent isotopic composition (delta17O = (delta17O - 0.512 * delta18O) no equal to 0) in aerosol sulfate and the identification of its origin (aqueous-phase oxidation by 03 and H2O2) have renewed interest in measuring the oxygen isotopic content of sulfate. In this paper, we present a new method to measure both delta17O and delta18O in SO4, with the possibility of sulfur isotope analysis on the same sample. The technique takes advantage of the easy pyrolysis of Ag2SO4 to SO2, O2, and Ag metal in a continuous flow system. Because the technique is not quantitative in oxygen (yield approximately 45% for O2), a calibration is needed. Correction factors of +0.87 and +0.44% were obtained for delta18O and delta17O, respectively. A technique to convert micromole levels of sulfate in any form to silver sulfate is described. To reach this goal, a solid electrolyte (Nafion membrane) is used in an electrolysis apparatus. Reproducibilities for micromole sample sizes are (1sigma) 0.5, 0.3, and 0.1% for delta18O, delta17O, and delta17O, respectively. No memory effects or isotopic exchange during the treatment of the sample is observed. The main advantages of this new method over the existing ones are no fluorinating agent is needed, both oxygen and sulfur isotopes can be measured on the same sample, only very small amounts of sulfate are needed (down to 100 microg (1 micromol)), it is relatively fast and inexpensive, and the possibility exists to couple this technique to an on-line analysis.

Journal Article↗

A bacterial method for the nitrogen isotopic analysis of nitrate in seawater and freshwater.

We report a new method for measurement of the isotopic composition of nitrate (NO3-) at the natural-abundance level in both seawater and freshwater. The method is based on the isotopic analysis of nitrous oxide (N20) generated from nitrate by denitrifying bacteria that lack N2O-reductase activity. The isotopic composition of both nitrogen and oxygen from nitrate are accessible in this way. In this first of two companion manuscripts, we describe the basic protocol and results for the nitrogen isotopes. The precision of the method is better than 0.2/1000 (1 SD) at concentrations of nitrate down to 1 microM, and the nitrogen isotopic differences among various standards and samples are accurately reproduced. For samples with 1 microM nitrate or more, the blank of the method is less than 10% of the signal size, and various approaches may reduce it further.

Fresh Water↗

On-line determination of oxygen isotope ratios of water or ice by mass spectrometry.

Oxygen isotope ratio determination on any of the water phases (water vapor, water, ice) is of great relevance in different research fields such as climate and paleoclimate studies, geological surveys, and hydrological studies. The conventional technique for oxygen isotope measurement involves equilibration with carbon dioxide gas for a given time with a subsequent isotope determination. The equilibration technique is available in different layouts, but all of them are rather time-consuming. Here we report a new on-line technique that processes water samples as well as ice samples. The same principal, CO2 hydration, is used but speeded up by (i) a direct injection and full dissolution of CO2 in the water, (ii) an increased isotope exchange temperature at 50 degrees C, and (iii) a rapid gas extraction by means of an air-permeable membrane into a continuous helium flux supplying the isotope ratio mass spectrometer with the sample gas. The precision is better than 0.1/1000 which is only slightly larger than with the conventional equilibration technique. This on-line technique allows analysis of 1 m of ice with a resolution of 1-3 cm, depending on the meltwater flux, within 1 h. Similarly, continuous and fast analysis can be performed for aqueous samples for hydrological, geological, and perhaps medical applications.

Journal Article↗

Determination of the total oxygen isotopic composition of nitrate and the calibration of a delta 17O nitrate reference material.

A thermal decomposition method was developed and tested for the simultaneous determination of delta 18O and delta 17O in nitrate. The thermal decomposition of AgNO3 allows for the rapid and accurate determination of 18O/ 16O and 17O/16O isotopic ratios with a precision of +/- 1.5 per thousand for delta 18O and +/- 0.11 per thousand for delta 17O (delta 17O = delta 17O - 0.52 x delta 18O). The international nitrate isotope reference material IAEA-NO3 yielded a delta 18O value of +23.6 per thousand and delta 17O of -0.2 per thousand, consistent with normal terrestrial mass-dependent isotopic ratios. In contrast, a large sample of NaNO3 from the Atacama Desert, Chile, was found to have delta 17O = 21.56 +/- 0.11 per thousand and delta 18O = 54.9 +/- 1.5 per thousand, demonstrating a substantial mass-independent isotopic composition consistent with the proposed atmospheric origin of the desert nitrate. It is suggested that this sample (designated USGS-35) can be used to generate other gases (CO2, CO, N2O, O2) with the same delta 17O to serve as measurement references for a variety of applications involving mass-independent isotopic compositions in environmental studies.

Journal Article↗

Improvement of measurement precision of SPME-GC/MS determination of tributyltin using isotope dilution calibration.

A unique approach was developed to improve the precision of quantification of tributyltin (TBT) in sedimentsby solid phase microextraction (SPME) using isotope dilution GC/MS. The precision of the analytical technique was initially evaluated using standard calibration solutions. In selective ion monitoring (SIM) mode, the relative standard deviation (RSD) obtained for TBT based on peak area response was 18% (n = 11). When an internal standard, tripropyltin (TPrT), was used, the RSD decreased to 12%. A significant improvement in the precision using SPME was noted when a 117Sn-enriched TBT spike was employed; the RSD decreased 4-fold to 3%. Detection limits of 0.2 and 20 ng(Sn) L(-1) were achieved with SPME sampling and liquid-liquid extraction, respectively. Six analyses were performed for determination of TBT in PACS-2 sediment Certified Reference Material using both standard additions and isotope dilution procedures. For the latter, a 117Sn-enriched TBT spike was used. A concentration of 0.88 +/- 0.03 microg g(-1) (RSD 3.4%) obtained using standard additions was in good agreement with the certified value of 0.98 +/- 0.13 microg g(-1) as tin. Concentrations found using isotope dilution were 0.895 +/- 0.015 microg g(-1) (RSD 1.73%) as tin and 0.874 +/- 0.014 microg g(-1) (RSD 1.66%) as tin using a liquid-liquid extraction and SPME sampling, respectively. A 2-fold improvement in the precision of TBT concentration measurement using isotope dilution was clearly achieved, demonstrating its superiority in providing more accurate and precise results as compared to the method of standard additions. The isotope dilution technique eliminated the problem of poor reproducibility, which typically plagues SPME.

Calibration↗

Isotopic fractionation during diffusion of transition metal ions in solution.

Isotope ratios and elemental concentrations were measured in aqueous solutions sampled at varying distances from sources of Fe or Zn ions. The measurements reveal fractionation of isotopes resulting from pure diffusion in solution. Our data demonstrate that diffusion alone can cause changes in (56)Fe/(54)Fe and (66)Zn/(64)Zn isotope ratios in excess of -0.3 per thousand. These findings thus confirm previous suspicions that transport processes contribute to observed variations in isotopic compositions. Diffusion must therefore be considered when attempting to make inferences from isotope measurements on samples originating from aqueous systems where concentration gradients may develop.

Journal Article↗

Chlorine isotope analysis of submicromole organochlorine samples by sealed tube combustion and thermal ionization mass spectrometry.

Improved sensitivity in the analysis of stable chlorine isotopes of organochlorines (delta(37)Cl-OCl) has been established using sealed tube combustion in conjunction with thermal ionization mass spectrometry (TIMS). TIMS of chlorine isotopes was performed on <85 nmol of Cl with an achievable precision of <0.25 per thousand for pure inorganic chloride samples and 0.46 per thousand for chloride liberated from organochlorines (OCls). This makes possible significant reductions in the overall sample size requirement, as compared to the techniques of gas source stable isotope ratio mass spectrometry (SIRMS). Yields in excess of 99% were demonstrated in the dechlorination of <0.14 micromol 1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane (DDT), and the overall yield, including purification of liberated chloride, was 86-97%. The accuracy of TIMS in the measurement of chlorine isotopes derived from OCls was confirmed by analysis of a DDT sample previously analyzed with SIRMS.(9) Using the described method for TIMS, the DDT sample gave a bulk chlorine isotope ratio of delta(37)Cl -4.42 +/- 0.46 per thousand (1sigma). The reported value from SIRMS analysis is -4.34 +/- 0.25 per thousand, indicating the conformity of the two methods.

Journal Article↗

Isotope effects in the transient phases of the reaction catalyzed by ethanolamine ammonia-lyase: determination of the number of exchangeable hydrogens in the enzyme-cofactor complex.

Transient phases of the reaction catalyzed by ethanolamine ammonia-lyase (EAL) from Salmonella typhimurium have been investigated by stopped-flow visible spectrophotometry and deuterium kinetic isotope effects. The cleavage of adenosylcobalamin (coenzyme B(12)) to form cob(II)alamin (B(12r)) with ethanolamine as the substrate occurred within the dead time of the instrument whenever coenzyme B(12) was preincubated with enzyme prior to mixing with substrate. The rate was, however, slowed sufficiently to be measured with perdeutero ethanolamine as the substrate. Optical spectra indicate that, during the steady states of the reactions with ethanolamine and with S-2-aminopropanol as substrates, approximately 90% of the active sites contain B(12r). Reformation of the carbon-cobalt bond of the cofactor occurs following depletion of substrate in the reaction mixtures, and the rate constant for this process reflects k(cat) of the respective substrates. This late phase of the reaction also exhibits (2)H isotope effects similar to those measured for the overall reaction with (2)H-labeled substrates. With unlabeled substrates, the rate of cofactor reassembly is independent of the number of substrate molecules turned over in the steady-state phase. However, with (2)H-labeled substrates, kinetic isotope effects appear in the reassembly phase, and these isotope effects are maximal after only approximately 2 equiv of substrate/active site are processed. With 5'-deuterated coenzyme B(12) and deuterated substrate, the isotope effect on reassembly is independent of the number of substrate molecules that are turned over. These results indicate that the pool of exchangeable hydrogens in the enzyme-cofactor complex is two-a finding consistent with the hydrogens in the C5' methylene of coenzyme B(12).

Catalysis↗

Solvent isotope effects on the onset of inhibition of porcine pepsin by pepstatin.

Pepstatin is a slow and tight-binding inhibitor of pepsin. Preincubating enzyme and inhibitor in H2O and in D2O in the absence of substrate generates an inverse solvent isotope effect of Dk = 0.69 +/- 0.06 on the apparent first-order rate constant for the decay in enzymatic activity. Proton inventory analysis of the inverse isotope effect suggests a single transition-state proton with a fractionation factor of 1.41 +/- 0.05. In contrast, combining enzyme with inhibitor and substrate (Leu-Ser-p-nitro-Phe-Nle-Ala-Leu-OMe) simultaneously along with observing the decay in enzymatic activity during catalytic turnovers generates a normal solvent isotope effect of Dk = 1.25 +/- 0.09. Proton inventory analysis of the normal isotope effect suggests a single reactant-state proton with a fractionation factor of 1.46 +/- 0.03. These two experimental designs are often considered equivalent, but the differences in isotopic data require that the pathway for onset of pepstatin inhibition in the absence of substrate must be different from the pathway in the presence of substrate. In the former, the inhibitor can only bind to free enzyme; in the latter, the inhibitor is hindered from binding to free enzyme because of competition with substrate but can bind to intermediate forms of enzyme generated during catalytic turnovers, downstream from enzyme-product complexes.

Animals↗

Mechanism of inhibition of dopamine beta-monooxygenase by quinol and phenol derivatives, as determined by solvent and substrate deuterium isotope effects.

The mechanism of interaction of quinols and phenols with dopamine beta-monooxygenase (D beta M) has been investigated. The ratio of quinone formation (from catechol) to oxygen consumption rises from a value of 1 in the presence of phenethylamine substrate to 2 in the absence of substrate. These results implicate quinol oxidation at both the reductant- and substrate-binding sites of D beta M. In the presence of saturating ascorbate, catechol and p-hydroquinol behave as mechanism-based inhibitors of D beta M, with partitioning ratios of turnover to inactivation of 21:1 and 41:1, respectively. Phenol is found to inactivate the enzyme in a manner similar to p-cresol, suggesting that the methyl group of p-cresol is not an essential component of enzyme inhibition. Solvent isotope effects on inactivation and turnover have been measured for various inactivators. Although the majority of these inhibitors, including catechol, p-hydroquinol, aniline, phenethylenediamine, and benzylhydrazine, are characterized by relatively small solvent isotope effects (1.5-2.5) on the inactivation rate constant (ki), solvent isotope effects on ki for phenol and p-cresol are 5.7 and 7.4, respectively. By contrast, solvent isotope effects on the turnover of p-cresol are almost unity. Using p-cresol-d7 as substrate, we observe D(kcat) = 5.2 and D(kcat/Km) = 3.1, while isotope effects on inactivation are D(ki) = 0.95 and D(ki/Ki) = 0.59. These results lead us to propose that inhibitors fall into two mechanistic classes, involving either one-electron oxidation to form radical cation intermediates (quinols) or hydrogen atom abstraction (phenols).(ABSTRACT TRUNCATED AT 250 WORDS)

Adrenal Glands↗