Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Elasticity”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

Identification of passive elastic joint moments in the lower extremities.

Musculotendon actuators produce active and passive moments at the joints they span. Due to the existence of bi-articular muscles, the passive elastic joint moments are influenced by the angular positions of adjacent joints. To obtain quantitative information about this passive elastic coupling between lower limb joints, we examined the passive elastic joint properties of the hip, knee, and ankle joint of ten healthy subjects. Passive elastic joint moments were found to considerably depend on the adjacent joint angles. We present a simple mathematical model that describes these properties on the basis of a double-exponential expression. The model can be implemented in biomechanical models of the lower extremities, which are generally used for the simulation of multi-joint movements such as standing-up, walking, running, or jumping.

Adult↗

The elasticity and the tensile strength of tunica albuginea of the corpora cavernosa.

The aim of this study was to determine the tensile strength and the elasticity of the tunica albuginea (TA), and describe morphological structures in the tissue before and after mechanical deformities. Twenty cadavers of men aged between 33 and 83 were examined. Cavernosometry was performed in all specimens. Afterwards in five cadavers the flow rate was increased until a herniation of the TA appeared. A strength about 1500 mm. Hg was found. Similar results were found in four who had an inflatable prosthesis (AMS 700) inserted, and the intraprosthetic pressure increased until a deformity was noted. Slices of TA (thickness 1.3 to 3.3 mm.) from 11 specimens were tested in a tensiometer. The elasticity coefficient was found to be around 10(8) N/m2, and the tensile strength to be 600 to 750 mm. Hg (10(4) to 10(5) N/m2). The difference between the tensile strength achieved in the tensiometer and during saline infusion is possibly caused by the intracavernous framework. Microscopy showed that TA is mainly composed of collagen fibres which are situated in an undulating arrangement, with a few elastic fibres arranged longitudinally which connect the undulating bundles of collagen fibres. When the tissue is overstretched, the elastic fibres are destroyed and the undulating arrangement disappears.

Adult↗

Development of elastic fibres in the upper urinary tract.

The development of elastic fibres in the upper urinary tract was studied in 31 fetuses ranging in ovulatory age from 10 to 24 weeks using special staining techniques for elastic fibres. The number, orientation and distribution of elastic fibres are described and correlated with age, ureteric level, and fetal weight. Significantly, before 10 weeks, elastic fibres were few in number, poorly developed, and randomly arranged. After 12 weeks, these fibres became more numerous at each level of the urinary tract, and were seen to develop specific orientation. The findings are described and potential clinical implications are discussed.

Elastic Tissue↗

Elastic jump in male urethra during voiding: clinical observations in male subjects and experimental studies in dogs.

A physical phenomenon known as elastic jump occurs downstream of an elastic constriction applied to a collapsible tube. This flow anomaly is analogous to the hydraulic jump that occurs in surface flows. Some investigators have predicted that an elastic jump could occur in the male urethra (during voiding) in the cavernous segment between constrictions at the membranous and meatal regions. To identify and understand this flow anomaly, and to obtain clinical correlations in human male subjects we have attempted several radiological and urodynamic studies in normal and abnormal subjects. The studies were retrograde urethrography, voiding cystourethrography, static pressure recordings during voiding and uroflowmetry. Retrograde urethrography was believed to delineate accurately the anatomy of the bulbous urethra. Voiding cystourethrography showed the geometry of the functional bulb. Our observations in 43 male subjects suggest that the site and degree of elastic jump depend on the severity of bladder neck or prostatic obstruction, magnitude of detrusor pressure (energy) during voiding, degree of distal constriction and position in which the subject voids. The animal studies (23 dogs) confirmed our clinical urodynamic impression.

Adult↗

Ultrastructure of elastic fibers as shown by polarization optics after the topo-optical permanganate-bisulfite-toluidine blue (PBT) reaction.

Permanganate-bisulfite-toluidine blue (PBT) reaction proved to be a highly selective and sensitive method for demonstration of elastic structures in tissue sections. Permanganate oxidation liberates a great amount of aldehyde groups in young and adult elastic fibers both in bovine ligamentum nuchae which can be demonstrated with the bisulfite-toluidine blue (pH = 1.0) staining procedure. There are suggestive evidences that the aldehyde groups are liberated from the desmosine and isodesmosine cross bondings of elastin. The dichroism and the strong birefringence of the elastic fibers induced by the PBT reaction indicate a high degree of linear fibrillar molecular order of the reacting elastin molecules which are assumed to be arranged helically in the aortic elastic fibers and they are assumed to show 2 different micellar textures in ligamentum nuchae fibers as reported with other topo-optical reactions earlier by Romhanyi.

Adult↗

The histomorphology of the elastic tissue system in the skin of the human hand.

This study compares the effectiveness of the Verhoeff and Puchtler-Sweat resorcin fuschin methods of staining the elastic tissue of palmar and dorsal skin specimens of the human hand. The resorcin stain demonstrates the "oxytalan" fibres of the elastic tissue system in the dermal papillary layer of the palmar skin. Oxytalan fibres are not generally demonstrated by the Verhoeff method and are not demonstrated in the dorsal skin specimens. These studies substantiate the existence of a system of elastic tissue fibres in the skin of the hand. The inter-relationship of the elastic and collagenous fibres appears to complement each of their functions; namely, in anchoring the dermo-epidermal junction, absorbing the stresses of stretch and compressive forces and return the tissues to their original state of tension, and providing protection to the dermal appendages in addition to lending a gradient mobility transmitted through the dermis to the subcutaneous layer to give suppleness and mobility to the skin.

Adult↗

Determination of the elastic modulus of resin based materials as a function of resonance frequency during polymerisation.

OBJECTIVES: The aim of this investigation is to describe the development of a novel non-invasive technique to measure the change in the elastic modulus of resin based restorative materials during polymerisation using resonance frequency analysis. METHODS: A transducer was developed which was designed to resonate at its first natural frequency in the range 5-15 kHz. The transducer was excited electronically and the response measured using a frequency response analyser. The transducer was mounted in a specimen well containing a range of test materials including unfilled resins, composites and luting cements. Each test material was polymerised by mixing and/or exposure to a visible light source and the frequency response measured at intervals during the curing process. The resonance frequency was determined at each interval by the measurement of the signal amplitude and phase. RESULTS: The resonance frequency of the transducer-resin system was plotted against time for the different material and curing combinations. Different sampling intervals were selected depending on the test procedure. All results showed a clear increase in resonance frequency as a function of the increase in stiffness and elastic modulus of the material during polymerisation. SIGNIFICANCE: A new non-invasive test method is described which can measure the increase in the elastic modulus of resin based materials as a function of resonance frequency. The technique is not sensitive to temperature, exhibits no drift and does not influence the polymerisation of the test material. Further development should enable resonance frequency measurements to be directly related to elastic material coefficients.

Composite Resins↗

Comparison of human fibroblast ECM-related gene expression on elastic three-dimensional substrates relative to two-dimensional films of the same material.

Three-dimensional elastic substrates were fabricated from a commercially available polyurethane with an internal porosity of approximately 70% and elastic modulus of 27.4+/-2.76 KPa and examined for suitability in vocal fold tissue engineering. Using immunohistochemistry, biomechanical testing, and RT-PCR; we examined human fibroblast viability, distribution and extracellular matrix related gene expression within substrates for periods up to 4 weeks. We found that cells were capable of colonizing the entire volume of a 5mm wide x 3mm deep x 20mm long substrate at high viability. Histological cross-sections showed extensive extracellular matrix deposited around the cells and throughout the pore structure of the substrates, which consisted of fibronectin and type I collagen. Cell seeded substrates displayed a significantly higher elastic modulus than unseeded controls similar to native tissue. The transfer of cell growth from two-dimensional to three-dimensional culture resulted in changes in ECM-related gene expression consistent with decreasing cell migration and increasing tissue formation. We found that fibroblasts cultured in three-dimensional substrates expressed significantly higher levels of mRNA for elastin and fibromodulin, while expressing significantly lower levels of mRNA for MMP-1 and hyaluronidase relative to two-dimensional substrates of the same material. The results suggest that three-dimensionally porous, Tecoflex-derived elastic biomaterials may be suitable substrates for engineering vocal fold tissue.

Actins↗

Correlation between drug release kinetics from proteineous matrices and protein folding: elasticity and compressibility study.

Naproxen sodium (NS) release mechanism from proteineous matrices based on egg albumin (EA) and bovine serum albumin (BSA) was investigated by several physico-chemical methods. The gel strength, modulus of elasticity and erosion properties of the matrices were studied and correlated with drug release kinetics. The results revealed that NS release rate from EA and BSA matrices was markedly different, indicating the significant role of protein nature and conformation on matrix behavior. Unexpectedly it was found that incorporation of NS to EA matrix increased gel strength and modulus of elasticity and decreased matrix erosion. This effect was dependent on NS concentration in the matrix. In contrast to EA, BSA behaved as a non-gelling matrix and was unable to retard drug release because of its high solubility. The influence of NS on protein folding and compressibility in protein solutions was studied using densitometric and ultrasonic techniques. Adiabatic compressibility measurements revealed that NS caused unfolding of EA, an effect which led to a decrease in EA intrinsic compressibility and the exposure of atomic side groups buried in protein interior. Unfolding of EA led to an increase of modulus of elasticity in solution (measured by ultrasonic velocimetry technique) which is in correlation with the modulus of elasticity measurements of gelled tablets (measured by Instron). In concentrated EA solutions, the results showed a large increase in EA compressibility and ultrasonic absorption in the presence of NS indicating a strong aggregation of the denatured state of EA. Regarding BSA, the results suggested that NS affected the packing of the protein interior, transforming it to a molten globule intermediate state, an effect that led to an increase in BSA compressibility. At high BSA concentrations, aggregation of the molten globule state was observed as indicated by an increase of BSA compressibility and ultrasonic absorption values.

Algorithms↗

Quantification of cutaneous sclerosis with a skin elasticity meter in patients with generalized scleroderma.

BACKGROUND: The skin score, a subjective assessment of skin elasticity, is widely used in patients with systemic sclerosis. Although this scoring method is regarded as a validated and accepted tool, the interobserver and intraobserver reproducibility is relatively poor. OBJECTIVE: Our purpose was to investigate whether the recently developed SEM 474 cutometer, which exerts a controlled vacuum force to the skin, can measure skin elasticity more objectively than the skin score. METHODS: Skin elasticity was measured in 74 different body areas in patients with systemic sclerosis and compared with the skin score obtained from the same areas. RESULTS: The cutometer produced quantitative and reproducible data. A large-diameter (8 mm) measuring probe was superior to a small probe. The interobserver intraclass correlation coefficient (ICC) was 0.92; the intraobserver ICC was 0.94. A linear correlation was found with the clinical skin score; the Spearman rank correlation test was 0.69. CONCLUSION: The correlation with the skin score was reasonable, despite the observation that regional differences in skin elasticity were detected by the cutometer but not by the human observer, who automatically compensates for these factors and integrates them into the skin score. The high interobserver and intraobserver ICC makes the cutometer more suitable for quantifying changes in skin thickness than the subjective skin score.

Adult↗

Elasticity mapping of living fibroblasts by AFM and immunofluorescence observation of the cytoskeleton.

Using the force mapping mode of atomic force microscopy (AFM), we measured spatial distribution of elastic moduli of living mouse fibroblasts (NIH3T3) in a physiological condition. The nuclear portion of the cellular surface is about 10 times softer than the surroundings. Stiffer fibers are confirmed in the elastic images. In order to investigate origin of the softer nuclear portion and the stiffer fibers, we fixed the identical cells imaged by the AFM, and carried out immunofluorescence observation for three types of cytoskeletal filaments--actin filaments, microtubules, and intermediate filaments, using confocal laser scanning microscopy (CLSM). A comparison between the AFM and the CLSM images revealed that the elasticity of the cells was concerned not only with the distribution of actin network, but also with intermediate filaments, whereas microtubules had no large effect on the measured elasticity.

3T3 Cells↗

The effect of hydrogen ion concentration on the force-degradation rate of orthodontic polyurethane chain elastics.

The effect of pH on the force-degradation rates of seven commercial orthodontic polyurethane chain elastics was evaluated in an in vitro study. The pH values of 4.95 and 7.26 were selected for testing because they represent values close to the reported extremes of plaque and saliva pH. Seven test elastic products were extended to (1) equal distances and (2) equal initial force levels, and the force-degradation rates were recorded over 4 weeks. All the test products yielded a significantly greater force-decay rate in the basic (pH 7.26) solution than in the acidic (pH 4.95) solution over 4 weeks. A hypothesis is presented that the decay rate of orthodontic polyurethane chain elastics is inversely proportional to the oral pH, with a corollary that basic pH levels are most hostile to polyurethane chain elastics.

Analysis of Variance↗

Correlation of end-diastolic pressure and myocardial elasticity with the transit time of the left atrial pressure wave (A-Ar interval).

Contraction of the left atrium in diastole generates a pressure wave that moves along the postero-lateral wall of the left ventricle (LV), rebounds off the LV apex, and is then directed toward the outflow tract. The movement of this atrial pressure wave may be detected with pulsed Doppler echocardiography by placing a sample volume in the LV outflow tract. The resulting spectral profile shows the initial. A velocity wave and also the Ar velocity wave, which is caused by the atrial pressure wave rebounding off the LV apex. The transit time from the inflow tract to the outflow tract of the atrial pressure wave (A-Ar interval) may be determined from the time axis of the spectral profile by measuring the peak-to-peak separation of the A and Ar, velocity waves. It occurs in the range 25 to 80 milliseconds. The primary determinant of the A-Ar interval is the elasticity of the LV myocardium. We correlated ventricular elasticity with the A-Ar interval in 47 patients and found a significant negative linear correlation (r = -0.782, p < 0.001). Because the pressure in a viscoelastic conduit such as the LV is determined by the elasticity of the ventricular wall, we correlated end-diastolic pressure with the A-Ar interval and again showed a significant negative linear correlation (r = -0.701, p < 0.001). The A-Ar interval is an easily measured noninvasive index of the diastolic function of the LV that reflects its intrinsic elasticity and end-diastolic pressure. It is therefore a quantitative measurement of LV wall stiffness and end-diastolic pressure.

Adult↗

Characterization of nano-dimensional thin-film elastic moduli using magnetoelastic sensors.

Application of magnetoelastic thick-film sensors to the measurement of thin-film elastic moduli is described in this study. An analytical model is derived, that relates the resonant frequency of a magnetoelastic sensor to the elasticity and density of an applied thin-film. Limits of the model are analyzed, and related to experimental measurements using thin-films of silver and aluminum. For 500 nm thick-films, the measured Young's modulus of elasticity for Al and Ag is found to be within 1.6% of standard data. Using commercially available magnetoelastic sensors, the elasticity of coatings, approximately 30 nm thick, can readily be measured.

Aluminum↗

Structural evidence for a possible role of reversible disulphide bridge formation in the elasticity of the muscle protein titin.

BACKGROUND: The giant muscle protein titin contributes to the filament system in skeletal and cardiac muscle cells by connecting the Z disk and the central M line of the sarcomere. One of the physiological functions of titin is to act as a passive spring in the sarcomere, which is achieved by the elastic properties of its central I band region. Titin contains about 300 domains of which more than half are folded as immunoglobulin-like (Ig) domains. Ig domain segments of the I band of titin have been extensively used as templates to investigate the molecular basis of protein elasticity. RESULTS: The structure of the Ig domain I1 from the I band of titin has been determined to 2.1 A resolution. It reveals a novel, reversible disulphide bridge, which is neither required for correct folding nor changes the chemical stability of I1, but it is predicted to contribute mechanically to the elastic properties of titin in active sarcomeres. From the 92 Ig domains in the longest isoform of titin, at least 40 domains have a potential for disulphide bridge formation. CONCLUSIONS: We propose a model where the formation of disulphide bridges under oxidative stress conditions could regulate the elasticity of the I band in titin by increasing sarcomeric resistance. In this model, the formation of the disulphide bridge could refrain a possible directed motion of the two beta sheets or other mechanically stable entities of the I1 Ig domain with respect to each other when exposed to mechanical forces.

Amino Acid Sequence↗

Tendon elasticity and muscle function.

Vertebrate animals exploit the elastic properties of their tendons in several different ways. Firstly, metabolic energy can be saved in locomotion if tendons stretch and then recoil, storing and returning elastic strain energy, as the animal loses and regains kinetic energy. Leg tendons save energy in this way when birds and mammals run, and an aponeurosis in the back is also important in galloping mammals. Tendons may have similar energy-saving roles in other modes of locomotion, for example in cetacean swimming. Secondly, tendons can recoil elastically much faster than muscles can shorten, enabling animals to jump further than they otherwise could. Thirdly, tendon elasticity affects the control of muscles, enhancing force control at the expense of position control.

Animals↗

Effect of compliant intermediate airways on total respiratory resistance and elastance in mechanical ventilation.

Total respiratory resistance and elastance were estimated off-line in a sample of 60 patients undergoing mechanical ventilation by means of two regression models in order to analyse and understand a possible physiological mechanism determining differences in inspiration and expiration. The first model considered a single value for resistance and elastance over a whole breathing cycle, whereas the second model considered separate values for inspiratory and expiratory resistance and a single value for elastance. Inspiratory resistance was found to be lower than expiratory resistance, and intermediate values were obtained for resistance estimated over the whole breathing cycle. Student's t-test showed a highly significant difference between these resistance estimates, and principal components analysis demonstrated a significant increase in information when both inspiratory and expiratory resistances were used. Minor differences were found between values of elastance calculated with the two approaches. In an attempt to interpret these experimental results, a lung model incorporating the non-linear viscoelastic properties of the intermediate airways was considered. This model suggested that changes in intermediate airway volume play a significant role in breathing mechanics during artificial ventilation and indicated that inspiratory and expiratory resistance could be useful parameters for locating airway obstruction.

Airway Resistance↗