A role for the magnetic field in the radiation-induced efflux of calcium ions from brain tissue in vitro.

Two independent laboratories have demonstrated that electromagnetic radiation at specific frequencies can cause a change in the efflux of calcium ions from brain tissue in vitro. In a local geomagnetic field (LGF) at a density of 38 microTesla (microT), 15- and 45-Hz electromagnetic signals (40 Vp-p/m in air) have been shown to induce a change in the efflux of calcium ions from the exposed tissues, whereas 1- and 30-Hz signals do not. We now show that the effective 15-Hz signal can be rendered ineffective when the LGF is reduced to 19 microT with Helmholtz coils. In addition, the ineffective 30-Hz signal becomes effective when the LGF is changed to +/- 25.3 microT or to +/- 76 microT. These results demonstrate that the net intensity of the LGF is an important variable. The results appear to describe a resonance-like relationship in which the frequency of the electromagnetic field that can induce a change in efflux is proportional to a product of LGF density and an index, 2n + 1, where n = 0,1. These phenomenological findings may provide a basis for evaluating the apparent lack of reproducibility of biological effects caused by low-intensity extremely-low-frequency (ELF) electromagnetic signals. In future investigations of this phenomenon, the LGF vector should be explicitly described. If the underlying mechanism involves a general property of tissue, then research conducted in the ambient electromagnetic environment (50/60 Hz) may be subjected to unnoticed and uncontrolled influences, depending on the density of the LGF.

Animals↗

Intracellular recording during magnetic field application to monitor neurotransmitter release events: methods and preliminary results.

A method for simultaneous magnetic field application and intracellular recording is presented. A little used method for magnetic field application was exploited; the field generator consisted of a flat copper sheet through which current was passed to generate a magnetic field. The resultant magnetic field was relatively homogeneous, exhibiting a variation of +/- 5%. This compact, current-sheet field generator was mounted on the condensor of a microscope. The current induced in the intracellular electrode was reduced by injecting current equal and opposite to the induced current into the microelectrode. This step reduces the possibility of cellular effects and voltage artifacts due to the induced electrode current. The technique was used to conduct preliminary studies on the effects of extremely low frequency (ELF) linearly and circularly polarized magnetic fields (1.0 Gauss, 60 and 70 Hz) on miniature end plate potential (mepp) frequency (frequency of neurotransmitter release events) of rat flexor digitorum brevis muscle. The same synapse was utilized for both the sham-exposed control and the exposed experimental halves of an experiment. After 10 min of exposure to a 60-Hz linear field, mepp frequency was significantly increased by 12%, but exposure to a 60-Hz circular field did not significantly alter mepp frequency. Exposure to a 70-Hz linear field did not significantly change mepp frequency, but application of a 70-Hz circular field appears to decrease mepp frequency by 4%. These results indicate that both types of magnetic fields can alter mepp frequency, depending upon the frequency and configuration of the field.

Animals↗

Multiple power-density windows and their possible origin.

We have previously reported that in vitro exposure of chick forebrain tissue to 50-MHz radiofrequency (RF) electromagnetic radiation, amplitude modulated (AM) at 16 Hz, would enhance the efflux of calcium ions within only two power-density ranges: one from 1.44 to 1.67 mW/cm2, and the other including 3.64 mW/cm2. No effect on efflux occurred at 0.37, 0.72, 2.17, and 4.32 mW/cm2. We confirmed and extended these results by testing at another set of power densities, which included the range of the previous study. Forebrain tissue from 1-7-day-old chickens was labeled in vitro with radioactive calcium ions (30 min, at 37 degrees C), rinsed, placed in a physiological salt solution, and then exposed for 20 min to 50-MHz radiation, AM at 16 Hz, in a transverse electric and magnetic field (TEM) cell maintained at 37 degrees C. The solution was then assayed for radioactive calcium activity. A power-density series was tested. An enhanced efflux of calcium ions was found at 1.75, 3.85, 5.57, 6.82, 7.65, 7.77, and 8.82 mW/cm2; no change was observed at 0.75, 2.30, 4.50, 5.85, 7.08, 8.19, 8.66, 10.6, and 14.7 mW/cm2. Power density is converted to specific absorption rate (SAR) by 0.36 mW/kg per mW/cm2. Even the highest SAR tested (0.005 W/kg) is much too low to result in generalized heating of the sample and thus to be the underlying cause of the enhanced response. A hypothetical mechanism is proposed involving dynamic systems that may account for the power-density dependency as well as for part of the frequency dependency observed with both modulated RF radiation and extremely-low-frequency (ELF) fields.

Animals↗

Influence of 60-Hz magnetic fields on sea urchin development.

Continuous exposure of sea urchin (Strongylocentrotus purpuratus) embryos at 18 degrees C to a cyclic 60-Hz magnetic field at 0.1 mT rms beginning 4 min after insemination caused a significant developmental delay during the subsequent 23 hours. No delay in development was recorded for periods up to 18 hours after fertilization. At 18 h, most embryos were in the mesenchyme blastula stage. At 23 h, most control embryos were in mid-gastrula whereas most magnetic-field-exposed embryos were in the early gastrula stage. Thus an estimated 1-h delay occurred between these developmental stages. The results are discussed in terms of possible magnetic-field modification of transcription as well as interference with cell migration during gastrulation. The present study extends and supports the growing body of information about potential effects of exposures to extremely-low-frequency (ELF) magnetic fields on developing organisms.

Animals↗

A three-dimensional method for calculating currents induced in bodies by extremely low-frequency electric fields.

A user-friendly, numerical program has been developed to permit the calculation of induced currents in modeled bodies of human and infrahuman subjects. The program is based on a charge-simulation method (CSM), and it takes into account the three-dimensional (3-D) character of the extremely-low-frequency (ELF) electric field and of the models to be exposed. The principle of the method is to simulate a 3-D object, for example, an animal model, by a combination of several parts (blocks) having simple geometric forms such as a sphere, a cylinder, or a cone. This approach permits easy preparation of input data on the dimensions of the blocks and their positions in a 3-D arrangement. Other input data, such as the coordinates of the contour points and the imaginary values of charges inside objects, which are necessary in the calculations by CSM, are produced automatically by selecting an appropriate "level" for each block, according to its importance. To simulate parts having irregular shapes, special blocks may be added. In one series of experiments, induced currents were calculated for a baboon model in various postures: standing upright, positioned on four legs, and sitting on the floor. Calculated currents, the total induced current in particular, agreed very well with experimental values. Local currents in parts of the baboon models were more variable, ranging from 5% to 17% of measured values in the case of induced currents in the head. Some problems with this method, such as the effect of the dimensions of blocks or the choice of block levels, are discussed.

Animals↗

Comparison of indices of ambient exposure to 60-hertz electric and magnetic fields.

Occupational, environmental, or domestic exposure of human beings to extremely low-frequency (50- or 60-Hz) electric and magnetic fields varies continuously over time. In epidemiological studies of possible health effects, exposures over long durations must be aggregated in terms of simple summary indices. However, there are many different, biologically plausible, ways of aggregating the data. While awake, each of 20 electric utility personnel and 16 office workers had provided minute-by-minute measures of incident electric (V/m) and magnetic (muT) fields over a 7-day period via personal dosimeters. Once the measures were aggregated as means, medians, peaks, and other indices, intercorrelations between all index pairs were calculated; correlation matrices are presented for the utility and office workers both by group and when pooled. Product-moment coefficients (r) greater that .80 were found between the time-weighted arithmetic mean (TWA) and indices that explicitly emphasize short but highly intense exposures, such as peak values and time above thresholds. Medians and geometric means were less highly correlated with the TWA. Use of only a few indices, perhaps the TWA alone, may sacrifice but little statistical power in most epidemiological studies of utility workers exposed to ELF fields. However, correlations between electric-field strength and magnetic-field density were generally quite weak, as were correlations of either with high-frequency transients; these findings underscore the need to measure each of these variables in epidemiological studies. Indices of exposure incurred outside the workplace were less strongly correlated, which may indicate the need to use several indices in general-population studies.

Electromagnetic Fields↗

Electric fields induced in chicken eggs by 60-Hz magnetic fields and the dosimetric importance of biological membranes.

Chicken eggs are convenient models for observing the effects of inhomogeneities and variations, such as those found in biological membranes and in cellular conductivities, on the distribution of internal electric fields as induced by exposure to magnetic fields. The vitelline membrane separates the yolk, which has a conductivity of 0.26 S/m, from the white, which has a conductivity of 0.85 S/m. A miniaturized probe with 2.4-mm resolution was used to measure induced fields in eggs placed in a uniform, 1-mT magnetic field at 60 Hz. The E fields induced in eggs with homogenized contents agreed with expectations based on simple theory. Results were similar to intact eggs unless the probe moved the yolk off-center, which greatly perturbed the induced fields. A more reproducible arrangement, which consisted of saline-agar filled dishes with a hole cut for test samples, was developed to enhance definition of electrical parameters. With this test system, the vitelline membrane was found to be responsible for most of the perturbation of the induced field, because it electrically isolates the yolk from the surrounding white. From a theoretical viewpoint, this dosimetry for the macroscopic egg yolk is analogous to the interaction of fields with microscopic cells. These findings may have important implications for research on biological effects of ELF electromagnetic fields, especially for studies of avian embryonic development.

Animals↗

An analysis of associations between social class and ambient magnetic fields in metropolitan Melbourne.

In the course of a study on residential magnetic-field exposure, some incidental data were obtained that bear on the issue of confounding of magnetic field exposure by social class. We have explored the possibility that the magnetic flux density of 50 Hz fields measured in Melbourne streets is correlated with a number of variables that index the socio-economic status of the neighborhood. We have examined also for a correlation between field-intensity levels and sums of some or all of the indicators, which were weighted to provide an overall score on socio-economic status. Although some of the indexes were weakly, but significantly, correlated with environmental levels of magnetic fields, the combined indices were not. These results indicate that socio-economic status is not likely to be a confounder in epidemiological studies of residential exposure to ELF magnetic fields in Melbourne.

Electromagnetic Fields↗

Relative-risk-estimate bias and loss of power in the Mantel test for trend resulting from the use of magnetic-field point-in-time ("spot") measurements in epidemiological studies based on an ordinal exposure scale.

We assessed the merits of various point-in-time ("spot") measurement protocols in case-control studies based on an ordinal exposure scale. After classifying a number of houses on the basis of prolonged monitoring of the ambient, extremely low frequency (ELF) magnetic field, we determined the probability of misclassification for each "spot" measurement protocol. We calculated the effect of this misclassification on the relative risk estimates and on the Mantel test for trend. We found that classification based on a small group of point-in-time measurements allows an adequate estimate of the relative risk, although the statistical significance of the dose-response gradient may be seriously underestimated. However, the use of automated ambient-field monitors, which results in loss of information on spatial variability, can lead to similar consequences. Therefore, manually collected point-in-time measurements remain a viable option for exposure assessment.

Air Pollution, Indoor↗

Experimental macroscopic dosimetry for extremely-low-frequency electric and magnetic fields.

Environmental and laboratory exposure to electric and magnetic fields (EMF) in the extremely-low-frequency range (ELF) produces electrical quantities that interact directly with the exposed biological system on a scale small compared to the size of the human body but large with respect to cellular dimensions. The purpose of this paper is to describe these macroscopic electrical quantities and their characterization through measurements on living systems and experimental models. Electric field exposure results in a total induced current, surface electric fields, internal electric fields, and internal currents. Magnetic field exposure results in internal magnetic field, internal electric fields, and internal currents. Basic properties of fields and matter determine the methods by which these quantities can be measured. Quantification or dosimetry for these parameters on a macroscopic basis can be directed to the whole body, a cross section across the body, a local surface area, or a local volume. Models of varying degrees of sophistication have been used to establish spatial distributions of external fields and internal fields and currents.

Animals↗

50-Hz magnetic field exposure system for small animals.

The design, construction, and results of evaluation of an animal-exposure system for the study of biological effects of extremely low frequency (ELF) magnetic fields are described. The system uses a square coil arrangement based on a modification of the Helmholtz coil. Due to the cubic configuration of this exposure system, horizontal and vertical magnetic fields as high as 0.3 mT can be generated. Circularly polarized magnetic fields can also be generated by changing the current and phase difference between two sets of coils. Tests were made for uniformity of the magnetic field, stray fields, sham-exposure ratio of stray field, changes of temperature and humidity, light intensity and distribution inside the animal-housing space, and noise due to air-conditioning equipment. Variation of the magnetic field was less than 2% inside the animal housing. The stray-field level inside the sham-exposure system is less than 2% of experimental exposure levels. The system can be used for simultaneous exposure of 48 rats (2 to a cage) or 96 mice (4 to a cage).

Animals↗

Design and characterization of a system for exposure of cultured cells to extremely low frequency electric and magnetic fields over a wide range of field strengths.

A system is described that is capable of producing extremely low frequency (ELF) magnetic fields for relatively short-term exposure of cultured mammalian cells. The system utilizes a ferromagnetic core to contain and direct the magnetic field of a 1,000 turn solenoidal coil and can produce a range of flux densities and induced electric fields much higher than those produced by Helmholtz coils. The system can generate magnetic fields from the microtesla (microT) range up to 0.14 T with induced electric field strengths on the order of 1.0 V/m. The induced electric field can be accurately varied by changing the sample chamber configuration without changing the exposure magnetic field. This gives the system the ability to separate the bioeffects of magnetic and induced electric fields. In the frequency range of 4-100 Hz and magnetic flux density range of 0.005-0.14 T, the maximum total harmonic distortion of the induced electric field is typically less than 1.0%. The temperature of the samples is held constant to within 0.4 degrees C by constant perfusion of warmed culture medium through the sample chamber.

Cells, Cultured↗

Early pregnancy loss and exposure to 50-Hz magnetic fields.

The possibility of an association of early pregnancy loss (EPL) with residential exposure to ELF magnetic fields was investigated in a case-control study. Eighty-nine cases and 102 controls were obtained from the data of an earlier study aimed at investigating the occurrence of EPL in a group of women attempting to get pregnant. Magnetic-field exposure was characterized by measurements in residences. Strong magnetic fields were measured more often in case than in control residences. In an analysis based on fields measured at the front door, a cutoff score of 0.5 A/m (0.63 microT) resulted in an odds ratio of 5.1 (95% confidence interval 1.0-25). The results should be interpreted cautiously due to the small number of highly exposed subjects and other limitations of the data.

Abortion, Spontaneous↗

Power frequency magnetic field exposures among nurses in a neonatal intensive care unit and a normal newborn nursery.

Given the current interest in potential carcinogenic and developmental effects of exposure to extremely-low-frequency electromagnetic fields, there is a need to identify cohorts of exposed female workers for future epidemiologic investigations. This study was designed to test the hypothesis that nurses working in neonatal intensive care units (NICU) may be significantly exposed to power-frequency magnetic fields. An electromagnetic field monitor was used to measure magnetic fields at distances of 5, 15, 30, and 60 cm from the surfaces of each device used in the NICU. Six female nurses assigned to the NICU (the "exposed" group) and six female nurses working in the normal newborn nursery (the "referent" group) wore EMDEX dosimeters for the entire duration of their 12 h shifts. An investigator kept a detailed log of each NICU subject's whereabouts for the first one-third of her shift. Magnetic fields at 5 cm from the front (defined by the nurses' usual work area) of the NICU devices ranged from less than 0.1 to 114 microT and in all cases decreased considerably with increasing distance. The geometric mean of the shift-time-weighted average exposure of the NICU nurses was 0.17 microT compared with 0.11 microT for the normal newborn nurses. The percentage of time when subjects were exposed to magnetic fields of 0.4 microT or greater ranged from 5.8% to 15.6% for the NICU nurses, 0.4% to 2.9% for five of the comparison group nurses, and was 9.4% for one of the normal newborn nurses with unidentified aberrantly high exposures. Log data revealed that the vast majority of observed peaks among NICU nurses occurred while subjects were in close proximity to infant bed units. We conclude that NICU nurses represent one female-intensive job sector with intermittent high exposures to ELF magnetic fields and encourage larger exposure studies of nurses in a variety of medical settings.

Cohort Studies↗

Trivial influences: a doubly stochastic Poisson process model permits the detection of arbitrarily small electromagnetic signals.

If a weak, exogenous, extremely low-frequency (ELF) electric or magnetic field is to produce biological sequelae, then there must exist averaging sufficient to lift some primary effect of that field above the endogenous stochastic variations of the biological system. One way in which a field could accomplish this is by changing the intensity of some stochastic operation that controls an important and not trivially reversible biological transformation. In this paper, this operation is modeled as a doubly stochastic Poisson process. It is then shown, first, that (in theory) even a minuscule exogenous influence might appreciably shift the incidence of a sufficiently rare transformation and, second, that this shift might be observable if a trial were allowed to run long enough over a sufficiently large population of exposed entities.

Algorithms↗

Model for external influences on cellular signal transduction pathways including cytosolic calcium oscillations.

Experiments on the effects of extremely-low-frequency (ELF) electric and magnetic fields on cells of the immune system, T-lymphocytes in particular, suggest that the external field interacts with the cell at the level of intracellular signal transduction pathways. These are directly connected with changes in the calcium-signaling processes of the cell. Based on these findings, a theoretical model for receptor-controlled cytosolic calcium oscillations and for external influences on the signal transduction pathway is presented. We discuss the possibility that the external field acts on the kinetics of the signal transduction between the activated receptors at the cell membrane and the G-proteins. It is shown that, depending on the specific combination of cell internal biochemical and external physical parameters, entirely different responses of the cell can occur. We compare the effects of a coherent (periodic) modulation and of incoherent perturbations (noise). The model and the calculations are based on the theory of self-sustained, nonlinear oscillators. It is argued that these systems form an ideal basis for information-encoding processes in biological systems.

Algorithms↗

Comment on "designing EMF experiments: what is required to characterize 'exposure'?".

Dr. Peter Valberg has written an excellent and clear paper describing our current understanding of the many facets of characterizing exposure to extremely-low-frequency (ELF) electric and magnetic fields. Dr. Valberg has directed his paper to the characterization of exposures used in laboratory experimentation. In this context, it seems to me that Valberg's program of exposure characterization can be accomplished with currently available instrumentation and with relatively modest effort. Thus, I have no fundamental problems with his recommendations and, really, have only a few minor comments to make. However, if one argues that Valberg's recommendations should be extended to the characterization of exposure in epidemiological research, I have serious reservations, which I will mention briefly at the end of this commentary.

Animals↗