Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Bronchoscopy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

Rifampicin concentrations in bronchial mucosa, epithelial lining fluid, alveolar macrophages and serum following a single 600 mg oral dose in patients undergoing fibre-optic bronchoscopy.

The concentrations of rifampicin in epithelial lining fluid (ELF), human alveolar macrophages (AM), bronchial mucosal biopsies and serum were measured after a single oral dose of 600 mg rifampicin from 15 patients undergoing fibre-optic bronchoscopy. The samples of ELF, AM, the bronchial mucosal biopsies and serum were obtained approximately 2-5 h after dosing. The mean concentrations (mean +/- standard error) were 5.25 mg/L (+/-0.67) in ELF, 7.93 mg/kg (+/-1.61) in bronchial biopsies, 15.48 mg/L (+/-1.41) in serum and 251.8 mg/L (+/-65.92) in alveolar macrophages. These site concentrations exceeded the MIC90 for common respiratory pathogens including Mycobacterium tuberculosis and support the observed clinical efficacy of rifampicin in the treatment of a wide range of respiratory tract infections.

Administration, Oral↗

Fluorescence versus white-light bronchoscopy for detection of preneoplastic lesions: a randomized study.

BACKGROUND: There are no currently approved methods for the screening and early detection of lung cancer. We compared the ability of conventional white-light bronchoscopy (WLB) and laser-induced fluorescence endoscopy (LIFE) to detect preneoplastic lung lesions in a randomized trial in which both the order of the procedures and the bronchoscopists were randomly assigned. METHODS: The study included high-risk subjects enrolled because of a cigarette smoking history of at least 30 pack-years, an air-flow obstruction, and either an abnormal sputum cytology (n = 48) or a previous or suspected lung cancer (n = 7). LIFE and WLB were performed on all patients. Biopsy specimens were assessed for histologic abnormalities, including the presence of angiogenic squamous dysplasia. All statistical tests were two-sided. RESULTS: A total of 391 biopsy specimens were taken from the 55 patients. Thirty-two patients (58%; 95% confidence interval [CI] = 44% to 71%) had at least one biopsy with moderate or severe dysplasia, and 19 (59%; 95% CI = 41% to 76%) of these patients could be diagnosed based solely on the results of LIFE. LIFE was statistically significantly more sensitive than WLB for detecting moderate dysplasia or worse (68.8% versus 21.9%, respectively) (difference = 46.9%; 95% CI = 25% to 68%; P< .001). The relative sensitivities (WLB = 1.0) were 3.1 (95% CI = 1.6 to 6.3) for LIFE and 3.7 (95% CI = 1.9 to 7.3) for LIFE and WLB combined. LIFE was less specific than WLB (69.6% versus 78.3%, respectively; P = .45), but the difference was not statistically significant. The relative specificities (WLB = 1.0) were 0.9 for LIFE (95% CI = 0.6 to 1.3) and 0.6 (95% CI = 0.4 to 1.0) for LIFE and WLB combined. The results were similar regardless of the order of the procedures or the order of the bronchoscopists. Also, LIFE was better at identifying angiogenic squamous dysplasia lesions than WLB (detection ratio [DR], which indicates the relative likelihood of getting a positive result in a sample with dysplasia compared with one without, for LIFE = 1.39 [95% CI = 1.17 to 1.65] versus DR for WLB = 0.67 [95% CI = 0.38 to 1.21]). CONCLUSION: LIFE was more sensitive than WLB in detecting preneoplastic bronchial changes in high-risk subjects. The prognostic implication of this finding is not yet clear.

Adult↗

High frequency jet ventilation in interventional fiberoptic bronchoscopy.

UNLABELLED: High frequency jet ventilation (HFJV) is a well accepted method for securing ventilation in rigid and interventional bronchoscopy. We describe a technique of HFJV using a 14F nylon insufflation catheter placed in the trachea to support stent implantation or endobronchial balloon dilation in endobronchial stenoses with the flexible fiberscope. One hundred sixty-one cases were treated with either a metal wire stent (n = 105) or with balloon dilation (n = 56). In addition to HFJV, IV anesthesia was applied in 132 cases. Driving pressure was 1125-1275 mm Hg, frequency 80-100/min, and inspiratory:expiratory ratio of 1:2. Fraction of inspired oxygen ranged from 0.3-1.0. The effects on alveolar ventilation were assessed by using blood-gas analysis and continuous monitoring of transcutaneous oxygen and carbon dioxide tension (P(tc)CO(2)). Complications consisted of hypertension (n = 8), hypotension (n = 6), bronchospasm (n = 5), and hypoxia (n = 6). In 52% of the cases, mild hypercarbia (P(tc)CO2 50-60mm Hg) was observed. In two cases, a P(tc)CO(2) > 80 mm Hg resolved spontaneously when the patients returned to normal breathing after intermittent superimposed ventilation with a face mask. During placement of stents in the proximal trachea, the jet catheter had to be withdrawn, resulting in displacement of the catheter into the pharynx in one case, which was managed safely with the bronchoscope. In conclusion, HFJV achieves satisfactory operating conditions and provides adequate gas exchange for interventional bronchoscopic procedures with the fiberscope. IMPLICATIONS: Safe ventilation is desired when performing tracheobronchial stent implantation and balloon dilation with the fiberscope. High frequency jet ventilation, applied with a 14F insufflation catheter through the nasotracheal route, offers safe ventilatory support with minimal complications. This was evaluated in 161 procedures treating benign and malignant airway stenoses.

Adult↗

The effect of clonidine premedication on hemodynamic responses to microlaryngoscopy and rigid bronchoscopy.

The usual hemodynamic response to laryngoscopy and bronchoscopy is an increase in heart rate and arterial blood pressure. Previous work has reported that 10%-18% of the patients develop ischemic ST segment changes during the procedure. Therefore, we performed a prospective, randomized, double-blinded study in 36 patients scheduled for elective microlaryngeal and bronchoscopic surgical procedures to evaluate the effects of 300-microg oral clonidine premedication (n = 18) or placebo (n = 18) on the hemodynamic alterations and the incidence of perioperative myocardial ischemic episodes. Myocardial ischemia was assessed by using continuous electrocardiographic monitoring, beginning 30 min before, and lasting until 24 h after the operation. During the procedure, patients receiving placebo exhibited a significant increase (mean +/- SD) in arterial blood pressure (the systolic increasing from 137+/-11 to 166+/-17 mm Hg, the diastolic increasing from 80+/-11 to 97+/-14 mm Hg) and heart rate (increasing from 79+/-15 to 97+/-12 bpm) compared with the baseline and with the clonidine group. A dose of 300-microg clonidine blunted the hemodynamic response to endoscopy. Ventricular arrhythmias were more frequent in patients who were not premedicated with clonidine. Two patients in the control group, but none in the clonidine group, had evidence of myocardial ischemia. These data should encourage routine premedication with clonidine in patients undergoing microlaryngoscopic and bronchoscopic procedures.

Adrenergic alpha-Agonists↗

Bronchoscopy via a redesigned Combitube in the esophageal position. A clinical evaluation.

BACKGROUND: The esophageal-tracheal Combitube (Kendall-Sheridan Catheter Corp., Argyle, NY) is an effective device for providing adequate gas exchange. However, tracheal suctioning is impossible with the Combitube placed in the esophageal position. To eliminate this disadvantage, the Combitube was redesigned by creating an enlarged hole in the pharyngeal lumen that allows fiberoptic access, tracheal suctioning, and tube exchange over a guide wire. METHODS: The two anterior, proximal perforations of regular Combitubes were replaced by a larger, ellipsoid-shaped hole. After the study was approved by the institutional review board, 20 patients with normal airways (Mallampati I or II) were studied. During general anesthesia, patients were esophageally intubated with the Combitube. A flexible bronchoscope was inserted and guided via the modified hole and glottic opening down the trachea. For the replacement procedure, a J tip guide wire was introduced through the bronchoscope. The bronchoscope and the Combitube were removed and a standard endotracheal tube was advanced over a guide catheter. RESULTS: Bronchoscopic evaluation of the trachea and guided replacement of the Combitube by an endotracheal tube was successful in all 20 study patients. The average time needed to perform airway exchange was 90 +/- 20 s (mean +/- SD). Arterial oxygen saturation and end-tidal carbon dioxide levels remained normal in all patients. No case of laryngeal trauma was observed during intubation or the airway exchange procedure. CONCLUSIONS: The redesigned Combitube enables fiberoptic bronchoscopy, fine-tuning of its position in the esophagus, and guided airway exchange in patients with normal airways. Further studies are warranted to demonstrate its value in patients with abnormal airways.

Adult↗

Comparison of direct examination of three types of bronchoscopy specimens used to diagnose nosocomial pneumonia.

OBJECTIVE: To compare direct examination of bronchial aspirate and plugged telescopic catheter specimens (PTC) with infected cell counts in bronchoalveolar lavage (BAL) specimens for the diagnosis of nosocomial pneumonia. DESIGN: Prospective study of critically ill patients. SETTING: Intensive care unit in a university hospital. PATIENTS: A total of 64 patients hospitalized for >48 hrs with suspected nosocomial pneumonia. INTERVENTIONS: Fiberoptic bronchoscopy with bronchial aspirate and quantitative protected specimen brush, PTC, and BAL cultures. PTC and bronchial aspirate specimens were Gram-stained. BAL specimens for infected cell counts were examined as described previously in the literature. MEASUREMENTS AND MAIN RESULTS: Nosocomial pneumonia was diagnosed by the medical staff based on all available clinical, radiologic, laboratory test, and microbiological data and on the course before and after appropriate therapy. A total of 71% of patients were ventilated, and 70.1% were receiving antibiotics. Nosocomial pneumonia was diagnosed in 54% of the cases. On direct examination, sensitivity (Se) and specificity (Sp) of bronchial aspirate specimens were Se, 82% and Sp, 60%; of BAL with 5% infected cells, Se, 56% and Sp, 100%; of BAL with 3% infected cells, Se, 74% and Sp, 96%; of PTC specimens, Se, 65% and Sp, 76%; and of PTC specimens plus BAL with 3% infected cells, Se, 83% and Sp, 78%. BAL with 3% infected cells was significantly better for predicting nosocomial pneumonia than direct examination of bronchial aspirate or PTC specimens (p = .0012). When the BAL showed 3% infected cells, neither direct examination of bronchial aspirate nor direct examination of PTC specimens was useful (p = .24 and p = .38, respectively). Combined use of direct examination of PTC specimens plus BAL with 3% infected cells markedly improved sensitivity. The total cost of each procedure was taken into account for the final evaluation. CONCLUSIONS: Our data suggest that BAL with 3% infected cells is currently the only test whose predictive value for nosocomial pneumonia is sufficiently high to be of use for guiding the initial choice of antimicrobial class while waiting for quantitative culture results.

Adult↗

Bronchoscopy with bronchoalveolar lavage via the laryngeal mask airway in high-risk hypoxemic immunosuppressed patients.

OBJECTIVE: Fiberoptic bronchoscopy (FOB) and bronchoalveolar lavage (BAL) are major tools in the diagnosis of pulmonary complications in immunocompromised patients. Nevertheless, severe hypoxemia is an accepted contraindication to FOB in nonintubated patients. The purpose of this study was to evaluate the feasibility and safety of laryngeal mask airway (LMA)-supported FOB with BAL in immunosuppressed patients with suspected pneumonia and severe hypoxemia. DESIGN: Prospective, clinical investigation. SETTING: Medical intensive care unit of a university hospital. PATIENTS: Forty-six immunosuppressed patients admitted to our intensive care unit with suspected pneumonia and Pao2/Fio2 < or = 125. INTERVENTIONS: After the administration of 0.3 mg x kg(-1) of etomidate, the patients were ventilated manually while receiving 1.0 Fio2. After the administration of 2.5 mg x kg(-1) of propofol, followed by an infusion of 9.1 +/- 2.3 mg x kg(-1) x hr(-1) of propofol, the LMA (size 3 or 4) was placed and connected to a bag-valve unit to allow manual ventilation with 1.0 Fio2. The FOB was introduced through a T-adapter attached to the LMA, and BAL was carried out with 150 mL of sterile 0.9% saline solution by sequential instillation and aspiration of 50-mL aliquots. MEASUREMENTS AND MAIN RESULTS: Three patients developed transient laryngospasm during passage of the bronchoscope via the LMA, which resolved with deepening of anesthesia. Changes in mean blood pressure, heart rate, Pao2/Fio2, and Paco2 values induced by the procedure did not reach significance. Seven patients (15%) presented hypotension (mean blood pressure, <60 mm Hg) maintained for 120 +/- 40 secs, which required plasma expanders in three cases. Oxygen desaturation to <90% occurred in six patients (13%) during BAL. Nevertheless, the lowest Sao2 during the procedure was significantly higher than the initial Sao2 (94% +/- 4% vs. 90% +/- 2%). No patient required tracheal intubation during the 8 hrs after the procedure. BAL had an overall diagnostic yield of 65%. Because of the results obtained by using the BAL analysis, treatment was modified in 33 (72%) cases. CONCLUSION: Application of the LMA appears to be a safe and effective alternative to intubation for accomplishing FOB with BAL in immunosuppressed patients with suspected pneumonia and severe hypoxemia.

Aged↗

Detection of bronchial abnormalities: comparison of CT and bronchoscopy.

We evaluated the usefulness of CT as compared with both visual and pathologic findings from fiberoptic bronchoscopy (FOB) in detecting bronchial lesions in 100 consecutive patients undergoing both procedures. There was agreement between CT and visual FOB in 83% of cases and CT and pathologic FOB in 68%. In the malignant disease category CT detected bronchial abnormalities in 59% (27 of 46) as compared with 57% (26 of 46) by visual FOB; both agreed in 81% of the cases (37 of 46). On the basis of CT findings alone, we retrospectively divided the cases into those for which we expected FOB to have high diagnostic yield (peribronchial abnormalities, n = 49) and a low diagnostic yield (i.e., no bronchial abnormality, n = 51). For the malignant disease category, selection by CT findings resulted in successful diagnosis by FOB in 69% for the high yield group as compared with 29% for the low yield group. We conclude that CT has excellent correlation with visual and pathologic results of FOB in detecting bronchial abnormalities and that CT, when used as an initial screening test, can enhance the yield by allowing appropriate selection of patients.

Bronchial Diseases↗

Dynamic and quantitative assessment of tracheomalacia by electron beam tomography: correlation with clinical symptoms and bronchoscopy.

PURPOSE: The purpose of this study was to evaluate the performance of electron beam tomography (EBT) in the dynamic and quantitative assessment of tracheal collapse in tracheomalacia. METHOD: Eight patients with suspected tracheomalacia were evaluated by EBT, and the results were correlated with both clinical symptoms and bronchoscopy. To validate this technique, an EBT phantom study preceded the patients' examination. A dynamic imaging sequence consisting of 20 50-ms scans obtained at 0.5 s intervals during a 10 s period was performed while the patient followed an instructed breathing maneuver. RESULTS: Good correlation between EBT data and clinical symptoms was found in all patients. In comparison to bronchoscopic findings, EBT results correlated well in three, showed limited correlation in three patients, and no correlation in one case. CONCLUSION: EBT with its short scanning time may be regarded as an accurate noninvasive method to dynamically evaluate tracheomalacia.

Adult↗

Effects of fiberoptic bronchoscopy on intracranial pressure in patients with brain injury: a prospective clinical study.

BACKGROUND: Fiberoptic bronchoscopy (FB) plays an important role in making the diagnosis of nosocomial pneumonia and resolving lobar atelectasis in critically injured trauma patients. It has been shown to be a safe procedure with only occasional complications. However, in patients with head injuries, FB can lead to intracranial hypertension. Sustained increases in intracranial pressure (ICP) leads to poor outcome in these patients. Because of this, a prospective study was done not only to assess the effect of FB on ICP and cerebral perfusion pressure (CPP) in patients with brain injuries, but also to identify a regimen of sedation and anesthesia that could prevent significant increases in ICP during FB. METHODS: Twenty-six FB were performed in 23 patients with ICP monitors or ICP monitors and ventriculostomy drains in place for Glasgow Coma Scale score < 8 or management of postcraniotomy trauma. FB was performed to aid in the diagnosis of nosocomial pneumonia or to aid in resolving lobar atelectasis. Before FB, all patients received a standard anesthetic regimen consisting of vecuronium (10 mg), morphine sulfate (4 mg), and midazolam (2.5 mg). Patients with diminished cranial compliance, defined as ICP > 10 mm Hg, also received a nebulizer treatment of 3 mL of 4% lidocaine before FB. All patients were preoxygenated with FIO2 = 1.0 for 10 minutes. Intracranial pressure, mean arterial pressure, and CPP were monitored continuously throughout the procedure. These same variables were also recorded at baseline and at 2-minute intervals during the procedure. The time to return to baseline ICP was also recorded. RESULTS: The mean ICP at baseline (immediately before FB) was 12.6 mm Hg. After introduction of the bronchoscope, the ICP rapidly increased in 21 procedures (81%) and the mean highest ICP was 38.0 mm Hg. There was also a concomitant increase in mean arterial pressure such that there was no substantial change in CPP. The mean lowest CPP was 73.1 mm Hg. The average time for return of ICP to baseline was 13.9 minutes. In the subgroup of patients with ICP > 10, attempting to blunt the tracheal stimulation by anesthetizing the trachea with 4% nebulized lidocaine did not seem to be successful. The mean highest ICP in this subgroup was 41.8 mm Hg. The CPP changed in a similar manner, as the mean lowest CPP was 74.0 mm Hg. The mean time to return to baseline was 12.5 minutes. No patient had acute neurologic deterioration secondary to FB. CONCLUSIONS: Although FB is an important procedure in the pulmonary care of head injured patients, it produces substantial, but transient, increases in ICP and should be used with caution in patients with diminished cranial compliance. Sedation, analgesia, paralysis, and topical tracheal anesthesia did not completely prevent the rise in ICP. Although no acute deterioration in condition occurred, secondary brain injury caused by localized cerebral ischemia is certainly possible. Because of the substantial increases in ICP, herniation may be precipitated in an occasional patient. Further study is needed to identify a regimen that will confer protection.

Adolescent↗

Propofol decreases waste anesthetic gas exposure during pediatric bronchoscopy.

OBJECTIVE: This study compared the anesthetic gas exposure and operating conditions during insufflation anesthesia with halothane-alone versus halothane-propofol in children undergoing direct laryngobronchoscopy. STUDY DESIGN: Forty-six children were enrolled in this randomized prospective study, with institutional review board approval and informed consent. METHODS: All children were anesthetized by halothane mask induction and anesthesia was maintained using spontaneous ventilation with insufflation. No muscle relaxants or opioids were used. In the halothane group, halothane was titrated as needed. In the propofol group, halothane was decreased to 1% inspired concentration and the propofol was titrated as needed to maintain spontaneous ventilation and a still patient. Trace anesthetic gases, hemodynamic stability, and operating conditions were measured. RESULTS: The groups were similar in age, weight, and bronchoscopy time. There was significantly less gas exposure in the propofol group (25 +/- 33 parts per million) versus the halothane group (66 +/- 97 ppm; P <.02). There was a trend toward earlier emergence in the halothane group (33 +/- 13 minutes) versus the propofol group (41 +/- 17 minutes). Postoperative stridor was common, occurring in 30% of children. CONCLUSIONS: Insufflation anesthesia with spontaneous respiration provides excellent surgical conditions for laryngobronchoscopy. The addition of propofol resulted in fewer airway complications (P =.047). Although the addition of propofol significantly decreased anesthetic gas exposure in the operating room, both techniques resulted in operating room pollution that exceeded the maximum levels of 2 ppm per hour recommended by the US National Institute for Occupational Safety and Health (NIOSH).

Air Pollution, Indoor↗

Role of flexible fiberoptic bronchoscopy in the diagnosis of childhood endobronchial tuberculosis.

Flexible fiberoptic bronchoscopy (FB) is a recently available tool for the investigation of pediatric pulmonary diseases. Endobronchial tuberculosis (ETB), a common complication of primary tuberculosis, has traditionally been diagnosed by clinical findings of bronchial obstruction and roentgenographic evidence of bronchial involvement. A retrospective study was conducted to determine the incidence of endobronchial tuberculosis in children diagnosed by traditional means as having uncomplicated primary tuberculosis. Analysis of the bronchoscopic findings of 36 children with active pulmonary tuberculosis revealed that 15 (41.7%) had endobronchial involvement. Significantly 10 (28%) children who had no clinical or radiologic evidence of endobronchial involvement had endobronchial tuberculosis; 4 (11%) had early and 6 (17%) had advanced ETB by FB. There were 6 patients with radiologic evidence suggestive of ETB, which was confirmed by FB in 5 patients. One child had a obstruction of a bronchus by mucus. The mucus was removed with subsequent expansion of the distal lung segment. Complications of the procedures were mild. FB is a safe procedure and a valuable aid for the rapid diagnosis of ETB.

Adolescent↗

Automated anatomical labeling of the bronchial branch and its application to the virtual bronchoscopy system.

This paper describes a method for the automated anatomical labeling of the bronchial branch extracted from a three-dimensional (3-D) chest X-ray CT image and its application to a virtual bronchoscopy system (VBS). Automated anatomical labeling is necessary for implementing an advanced computer-aided diagnosis system of 3-D medical images. This method performs the anatomical labeling of the bronchial branch using the knowledge base of the bronchial branch name. The knowledge base holds information on the bronchial branch as a set of rules for its anatomical labeling. A bronchus region is automatically extracted from a given 3-D CT image. A tree structure representing the essential structure of the extracted bronchus is recognized from the bronchus region. Anatomical labeling is performed by comparing this tree structure of the bronchus with the knowledge base. As an application, we implemented the function to automatically present the anatomical names of the branches that are shown in the currently rendered image in real time on the VBS. The result showed that the method could segment about 57% of the branches from CT images and extracted a tree structure of about 91% in branches in the segmented bronchus. The anatomical labeling method could assign the correct branch name to about 93% of the branches in the extracted tree structure. Anatomical names were appropriately displayed in the endoscopic view.

Algorithms↗

Flexible fiberoptic bronchoscopy in sarcoidosis.

Twenty-nine patients with clinical signs, chest X-ray and histology consistent with sarcoidosis have been studied with flexible fiberoptic bronchoscopy (FFB) and scalene node biopsy. The diagnostic yield from bronchial mucosal biopsies was 41%, and from transbronchial lung biopsy 43%. 52% of the patients showed epithelioid cell granulomas with FFB (lung and/or mucosal biopsies) compared with 79% with scalene node biopsy. Three patients showed extensive bronchial mucosal changes with stenosing processes due to sarcoidosis. Sarcoidosis of the bronchial mucosa is a frequnt finding, and FFB is the best method for discovering bronchial mucosal sarcoidosis with or without stenosing processes. In our opinion, FFB has a place as a routine method in diagnosing sarcoidosis.

Adult↗