Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Biological samples”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

Determination of cannabinoids in biological samples using a new solid phase micro-extraction membrane and liquid chromatography-mass spectrometry.

A simple, rapid and relatively solventless method for extraction of objective compounds would be useful for forensic, judicial and clinical purposes. Solid phase micro-extraction membrane (SPMEM) is one such extraction technique that integrates sampling, extraction and concentration into a single step, and combines the advantages of both the solid phase micro-extraction (SPME) and membrane separation. In this study, a new kind of membrane was prepared using polyamide and Tenax compounds, and applied to solid phase micro-extraction. Characteristics of the membrane such as adsorption capacity were tested. Extraction conditions such as adsorption time, desorption solvents, desorption time and assisted desorption treatment methods were studied and optimized. Tetrahydrocannabinol (THC) and cannabidiol (CBD) in blood and brain of the injected male mice, and in spiked human urine were extracted using this solid phase micro-extraction membrane method. The extracted THC and CBD were further determined with LC-MS using APCI. Ions analyzed in single ion monitoring mode were 315 for THC and CBD, and 318 for the deuterated THC internal standard.

Animals↗

Solvent-free MALDI-MS for the analysis of biological samples via a mini-ball mill approach.

An efficient, low sample load mini-ball mill (MBM) sample preparation procedure was developed for solvent-free MALDI analysis of peptides and proteins. Picomole sample amounts can be handled conveniently, with 30 s grinding times being sufficient. Matrix purity and molar analyte/matrix ratios are not as critical as with methods employing solvent. Ammonium salt is employed for protonation of the peptide and suppression of sodiation. This strategy allows for peptide mapping and other biochemical manipulations to be performed prior to MBM sample preparation and mass analysis. The analysis of bovine serum albumin (66 kDa) yielded good results, indicating that higher molecular weight proteins are accessible. A semi-solvent-free strategy by the MBM sample preparation method is also described.

Animals↗

Reversed-phase liquid chromatography method to determine COL-3, a matrix metalloproteinase inhibitor, in biological samples.

A reversed-phase high-performance liquid chromatographic (HPLC) method with ultraviolet (UV) detection was developed and validated for the quantification of 6-deoxy-6-demethyl-4-dedimethylamino-tetracycline (COL-3), a matrix metalloproteinase (MMPs) inhibitor, in rat serum. This simple, sensitive, rapid and reproducible assay involved a preliminary serum deproteinization by adding a mixture of acetonitrile-methanol-0.5 M oxalic acid (70:20:10 (v/v)), as the combined precipitant and metal blocking agent, into serum samples (2:1 (v/v)). An aliquot (20 microl) of the supernatant was injected into the HPLC system linked to a Waters XTerra RP(18) column (150 mm x 4.6 mm i.d., particle size 5 microm). The compound was eluted by a mixture of acetonitrile-methanol-0.01 M oxalic acid (40:10:50 (v/v), pH 2.00), as the mobile phase, and detected at the wavelength of 350 nm. The total running time was 10 min. The low and high concentration calibration curves were linear in the range of 50-1200 ng/ml and 1200-12,000 ng/ml, respectively. The intra- and inter-day coefficients of variation at three quality control concentrations of 100, 1200, and 12,000 ng/ml were all less than 6%, while the percent error ranged from -2.5 to 6.6%. The limit of quantitation (LOQ) for COL-3 in serum was 50 ng/ml. This assay was successfully employed to study the serum concentration-time profiles of COL-3 after its intravenous and oral administration in rats. The method with some minor modifications in sample pretreatment was also applicable to the determination of the concentrations of COL-3 in rat bile, urine and feces.

Animals↗

Determination of myo-inositol in biological samples by liquid chromatography-mass spectrometry.

Due to the absence of HPLC methods to determine myo-inositol using mass detection and considering its sensitivity and selectivity, a high performance liquid chromatography-mass spectrometry method for the analysis of myo-inositol is described and applied to its direct determination in urine and saliva samples. Successful resolution of myo-inositol and its related substances was achieved with a stationary phase Aminex HPX-87C Column with milli-Q water as mobile phase and 5 mM ammonium acetate added post-column. The detector counted positive ions by monitoring m/z = 198, which corresponds to the myo-inositol adduct with ammonium cation. Urine and saliva samples were previously purified by passing through an anion-exchange resin. Concentrations as low as 138 and 461 microg/l in saliva and urine could be respectively quantified. Intra-day R.S.D. ranged from 0.83 to 1.02%, whereas inter-day R.S.D. was between 1.54 and 3.58%.

Chromatography, High Pressure Liquid↗

Development and validation of a simple liquid chromatographic method with ultraviolet detection for the determination of imatinib in biological samples.

The aim of this study was to develop a rapid and sensitive HPLC method with UV detection for the estimation of imatinib from the plasma of patients with chronic myeloid leukemia (CML). The robustness of the method was checked by conducting first dose pharmacokinetics on blood samples from four patients who had been administered Gleevec (100 mg) in an oral dose. Samples were prepared in a simple and single step by precipitating the plasma proteins with methanol and injecting 50 microl aliquot from supernatant was subjected for analysis. Assay was conducted using a C8 column (250 mm x 4.6 mm, 5 microm particle size) under isocratic elution with 0.02 M potassium dihydrogen phosphate-acetonitrile (7:3, v/v) at a flow rate of 1 ml/min and detected using photodiode array at 265 nm. Calibration plots in spiked plasma were linear in a concentration range of 0.05-25 microg/ml. The inter and intra-day variation of standard curve was <4% (R.S.D.). This method could be a simple and quick method for the estimation of imatinib from the patient's plasma.

Administration, Oral↗

Evaluation of dynamic headspace with gas chromatography/mass spectrometry for the determination of 1,1,1-trichloroethane, trichloroethanol, and trichloroacetic acid in biological samples.

A sensitive and reproducible method is described for the analysis of trichloroacetic acid in urine and 1,1,1-trichloroethane in blood using dynamic headspace GC/MS. Samples were analyzed using the soil module of a modified purge and trap autosampler to facilitate the use of disposable purging vessels. Coefficients of variation were below 3.5% for both analytes, and response was linear in the range of 0.01-7.0 microg/ml for trichloroacetic acid and 0.9 ng/ml-2.2 microg/ml for 1,1,1-trichloroethane. Attempts at using dynamic headspace for the analysis of trichloroethanol in urine were unsuccessful.

Ethylene Chlorohydrin↗

A novel HPLC procedure for detection and quantification of aminoacetone, a precursor of methylglyoxal, in biological samples.

Increase in methylglyoxal is thought to be involved in different pathological conditions. Deamination of aminoacetone by semicarbazide-sensitive amine oxidase (SSAO) leads to production of methylglyoxal. We have synthesized aminoacetone and developed a novel HPLC procedure for its quantitative determination. The urinary excretion of aminoacetone is approximately 20-30 microg/mouse/day, and the concentration is about 0.5 microg/g in mouse liver and small intestine. SSAO inhibitor increases aminoacetone levels in both tissues and urines. Results confirm that aminoacetone is an endogenous substrate for SSAO. However, data also indicate that deamination is not the only catabolic pathway for aminoacetone.

Acetone↗

Specific determination of threonine in biological samples by gas chromatography with electron capture detection.

Threonine was oxidized into acetaldehyde at 0 degrees C for 30 min with periodic acid. The acetaldehyde formed was converted to a hydrazone with 2,4-dinitrophenyhydrazine. The hydrazone was extracted with n-heptane and quantified by gas liquid chromatography with electron capture detection. An internal standard, 2-amino-3-hydroxyhexanoic acid, was used. The calibration curve of threonine was linear up to 200 nmol in 200 microl sample solution and the determination limit of threonine was 1 nmol in 200 microl sample solution. The recoveries were 100.0, 94.0 and 100.0% from homogenates of octopus tentacles and blood plasma and rat livers, respectively. This method was applied to the determination of threonine in tissues of rats given threonine and starved octopuses. This threonine determination method has been used for studies on the metabolism of d-lactate.

Animals↗

Thalidomide enantiomers: determination in biological samples by HPLC and vancomycin-CSP.

Thalidomide is a racemate with potentially different pharmacokinetics and pharmacodynamics of the component (+)-(R)- and (-)-(S)-thalidomide enantiomers. As part of a project on the adjunctive effects of thalidomide and cytotoxic agents, a method for the chiral separation and quantitation of thalidomide was developed and validated. Thalidomide in relevant serum and tissue homogenate samples was stabilized by buffering with an equal volume of citrate-phosphate buffer (pH 2, 0.2M), and stored at -80 degrees C pending assay. The thalidomide enantiomers, extracted from the samples with diethyl ether, were well separated on a chiral HPLC column of vancomycin stationary phase and a mobile phase of 14% acetonitrile in 20 mM ammonium formate adjusted to pH 5.4; their concentrations were determined with phenacetin as internal standard at 220 nm detection. Over a thalidomide concentration range of 0.1-20 microg/ml, assay precision was 1-5% (CV) for both enantiomers, and calibration curves were linear with all correlation coefficients being >0.99. The estimated limit of quantification for both enantiomers was 0.05 microg/ml with 0.2-0.6 ml serum samples. Thalidomide in rat and human serum, acidified and stored as described above, was found to be chemically and chirally stable over 1 year. The method has been successfully applied to serum samples from human patients undergoing thalidomide treatment for mesothelioma, and to serum, blood and tissue samples from a laboratory rodent model using transplanted 9l gliosarcoma. Enantioselectivity in thalidomide pharmacokinetics has been found, thereby reinforcing the need for considering the relevance of chirality in thalidomide pharmacology.

Animals↗

Determination of agmatine in biological samples by capillary electrophoresis with chemiluminescence detection.

A fast and simple method based on capillary electrophoresis (CE) with chemiluminescence (CL) detection has been developed for the determination of agmatine, a recently identified neurotransmitter/modulator. The CE run time was approximately 2 min for each sample injected. CL detection employed a lab-built reaction flow cell and a photon counter. The CL reagents used were luminol and NaBrO. The optimized conditions for the CL detection were 5 x 10(-4)M luminol added to the CE running buffer and 5.0 x 10(-4)M NaBrO in 100 mM NaCO3-NaOH buffer solution at pH 12.5 introduced post column. Detection limit for agmatine was 4.3 x 10(-6)M (S/N=3). The precision (R.S.D.) on peak height (at 1 x 10(-5)M agmatine) and migration time were 3.7 and 2.5%, respectively. The present CE-CL method was evaluated with the determination of agmatine in tissue samples taken from rat brain, and rat and monkey stomachs. Samples were directly injected into the CE-CL system after the removal of proteins. A higher level of agmatine was detected in the stomach samples. Agmatine concentrations in the tissue samples taken from rat and monkey stomachs were similar at approximately 1950 ng/g wet tissue.

Agmatine↗

High-performance liquid chromatography/tandem mass spectrometric assay for the simultaneous measurement of dopamine, norepinephrine, 5-hydroxytryptamine and cocaine in biological samples.

A rapid liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed for the measurement of dopamine (DA), 5-hydroxytryptamine (5HT) and norepinephrine (NE) in brain microdialysates. The assay has also been utilised for the simultaneous measurement of these neurotransmitters and cocaine in brain dialysates. The neurotransmitters and cocaine were resolved in a single 4-min run using a binary gradient elution profile. The analytes were detected using tandem mass spectrometry in the positive ion electrospray mode. The limits of detection for DA, NE, 5HT and cocaine were 200, 1000, 900 pM and 1 pg ml(-1), respectively.

Animals↗

Sensitive SPE-HPLC method to determine a novel angiotensin-AT1 antagonist in biological samples.

A high-performance liquid chromatography (HPLC)-method after solid-phase extraction (SPE) has been developed in order to determine a new angiotensin-AT1 antagonist, i.e. CR 3210 (C27H24N8; MW = 460.54), 4-[4-[(2-ethyl-5,7-dimethylimidazo[4,5-b]pyridin-3-yl)methyl]phenyl]-3-(2H-tetrazol-5-yl)quinoline in rat plasma and urine after oral administration to Sprague-Dawley rats. CR 3210 and the internal standard (IS) CR 1505 (loxiglumide), i.e. 4-[(3,4-dichlorobenzoyl)amino]-5-[(3-methoxypropyl)pentylamino]-5-oxopentanoic acid, were isolated from rat urine and plasma by solid-phase extraction. The procedure was optimized regarding the sorbent extraction material, the pH in the conditioning solution, the washing step, the dry time and the type of elution solvent. The separation was performed by reversed-phase high-performance liquid chromatography with ultraviolet detection. The samples were injected onto the analytical column (Tracer Extrasil ODS1) and detected at 238 nm, giving a capacity factor of 1.87 for CR 3210 and 1.10 for the internal standard. The selectivity of the method was satisfactory. The mean recovery of CR 3210 from spiked rat plasma was 68.5 at 75 ng/ml and 80.9 at 3000 ng/ml; the mean recovery of CR 3210 from spiked rat urine was 69.9 at 75 ng/ml and 78.6 at 3000 ng/ml. The lower limit of detection (LOD) was 14 ng/ml in plasma and 22 ng/ml in urine samples. The lower limit of quantification (LOQ) was taken as 30 ng/ml, the lowest calibration standard using 500 microl rat plasma and urine. The procedures were validated according to international standards with a good reproducibility and linear response from 30 to 3000 ng/ml, for either plasma or urine. The sensitivity of the method allowed for its application to pharmacokinetic studies.

Angiotensin II Type 1 Receptor Blockers↗

Measuring tobacco smoke exposure: quantifying nicotine/cotinine concentration in biological samples by colorimetry, chromatography and immunoassay methods.

Procedures to assess tobacco smoke exposure are reviewed and biomarkers used for determining the smoking status of an individual are compared. Methods used to extract these biomarkers from saliva, urine, and blood and the advantages and disadvantages of the assays are discussed. Finally, the procedures used to measure the levels of cortisol, a stress hormone speculated to be linked to nicotine metabolism, are discussed.

Chromatography, High Pressure Liquid↗

Amperometric biosensor based on horseradish peroxidase for biogenic amine determinations in biological samples.

An amperometric biosensor for total biogenic amine determinations, using a carbon paste electrode modified with horseradish peroxidase (HRP) enzyme is described. The HRP immobilization on graphite was made using bovine serum albumin, carbodiimide and glutaraldehyde. The biosensor response was optimized using serotonin and it presented the best performance in 0.1 mol l(-1) phosphate buffer (pH=7.0) containing 10 micromol l(-1) of hydrogen peroxide. Under optimized operational conditions at -50 mV versus SCE, a linear response range from 40 to 470 ng ml(-1) was obtained. The detection limit was 17 ng ml(-1) and the response time was 0.5s. The proposed sensor presented a stable response during 4h under continuous monitoring. The difference of the response between six sensor preparations was <2%. The sensor was applied in the determination of total biogenic amines (neurotransmitters) in rat blood samples with success, obtaining a recovery average of 102%.

Animals↗

Kinetic disposition of lorazepam with focus on the glucuronidation capacity, transplacental transfer in parturients and racemization in biological samples.

The present study investigates the kinetic disposition with focus on the racemization, glucuronidation capacity and the transplacental transfer of lorazepam in term parturients during labor. The study was conducted on 10 healthy parturients aged 18-37 years with a gestational age of 36-40.1 weeks, treated with a single oral dose of 2 mg racemic lorazepam 2-9 h before delivery. Maternal venous blood and urine samples were obtained over a 0-48 h interval and the umbilical cord sample was obtained immediately after clamping. Lorazepam enantiomers were determined in plasma and urine samples by LC-MS/MS using a Chiralcel OD-R column. In vitro racemization of lorazepam required the calculation of the pharmacokinetic parameters as isomeric mixtures. The data were fitted to two-compartment model and the pharmacokinetic parameters are reported as means (95% CI): t(1/2a) 3.2h (2.6-3.7 h), K(a) 0.23 h(-1) (0.19-0.28 h(-1)), t(1/2) 10.4h (9.4-11.3h), beta 0.068 h(-1) (0.061-0.075h(-1)), AUC(0-infinity) 175.3(ngh)/ml (145.7-204.8(ngh)/ml), Cl/F 2.6 ml/(minkg) (2.3-2.9 ml/(minkg)), Vd/F178.8l (146.5-211.1l), Fel 0.3% (0.1-0.5%), and Cl(R) 0.010 ml/(minkg) (0.005-0.015 ml/(minkg)). Placental transfer of lorazepam evaluated as the ratio of vein umbilical/maternal vein plasma concentrations, obtained as an isomeric mixture, was 0.73 (0.52-0.94). Pregnancy changes the pharmacokinetics of lorazepam, with an increase in the apparent distribution volume, an increase in apparent oral clearance, and a reduction of elimination half-life. The increase in oral clearance may indicate an increase in glucuronidation capacity, with a possible reduction in the plasma concentrations of drugs depending on glucuronidation capacity as the major metabolic pathway.

Adolescent↗

Determination of reduced and oxidized glutathione in biological samples using liquid chromatography with fluorimetric detection.

A HPLC method for determination of both reduced (GSH) and oxidized (GSSG) glutathione in plasma, whole blood and rat hepatocytes has been developed and evaluated. Reduced glutathione reacts with orthophthaldehyde (OPA) to form a stable, highly fluorescent tricyclic derivate at pH 8, while GSSG reacts with OPA at pH 12. At measurement of GSSG, GSH was complexed to N-ethylmaleimide. For the separation, reverse phase column Discovery C(18), 150 mm x 4 mm, 5 microm, was used. The mixture of methanol and 25 mM sodium hydrogenphosphate (15:85, v/v), pH 6.0, was used as mobile phase. The analytical performance of this method is satisfactory for both GSH and GSSG. The intra-assay coefficients of variation were 1.8 and 2.1% for whole blood, 2.0 and 1.9% for rat hepatocytes, 4.3 and 5.2% for plasma. The inter-assay coefficients of variation were 5.8 and 6.2% for whole blood, 6.6 and 7.1% for rat hepatocytes, 6.9 and 7.8% for plasma. The recoveries were as follows: 98.2% (CV 3.5%) and 101.5% (CV 4.2%) for whole blood, 99.1% (2.5%) and 102.3 (4.4%) for rat hepatocytes, 94.1% (CV 7.5%) and 103.5 (CV 8.5%) for plasma. The calibration curve was linear in the whole range tested. The limit of detection was 14.0 and 5.6 fmol, respectively. The preliminary reference ranges of reduced and oxidized glutathione in a group of blood donors are (4.69+/-0.93) and (0.28+/-0.12)micromol/gHb for whole blood, (1.82+/-0.55) and (0.154+/-0.044)microM for plasma.

Adult↗

Selenium levels in related biological samples: human placenta, maternal and umbilical cord blood, hair and nails.

A study on selenium levels has been carried out in human placenta, maternal and umbilical cord blood, hair and nails of a group of 50 mothers and in the hair of the newborns. The determinations were perfomed by electrothermal atomic absorption spectrometry. The selenium concentration obtained for each sample type was as follows: For the human placenta the values obtained were between 0.56 and 1.06 microg/g (mean +/- standard deviation: 0.81 +/- 0.02 microg/g). The levels for the umbilical cord blood were 51.1-104.2 microg/l (76.3 +/- 6.5 microg/l). For the maternal blood the values measured were between 57.3 and 117.9 microg/l (90.0 +/- 15.2 microg/l), and for hair and nails were 0.22-1.5 microg/g (0.60 +/- 0.37 microg/g) and 0.46-1.57 microg/g (0.90 +/- 0.27 microg/g), respectively. For the hair of the newborns the values obtained were between 0.40 and 2.53 microg/g (1.04 +/- 0.48 microg/g). The effect of different variables as age, habitat, nutritional index or gestation age of the mothers on the selenium concentration in the samples was studied. The influence of the habitat is significant with a confidence level of 95% for the selenium concentration in maternal blood and umbilical cord blood samples. The influence of the mothers' age is significant with a confidence level of 95% for the selenium concentration in the umbilical cord blood samples. For the placenta samples, the effect of the nutritional index is significant with a confidence level of 95%. There is a positive correlation between samples of umbilical cord blood and the newborns' hair, between placenta and umbilical cord, and between cord blood and maternal blood.

Female↗