Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Analytic Sample Preparation Methods”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 991 records · Page 55Linked to original sources

Analysis of cationic nutrients from foods by ion chromatography.

This paper describes the feasibility of combining two relatively new technologies to generate data on the cationic nutrient content of foods. Single-column ion chromatography was used to monitor several analytes following the use of a microwave digestion scheme aimed at rapid, multiple sample digestion. The result is a more streamline and productive approach to multi-sample preparation and multi-analyte determination when investigating the cation content of foods. Linearity and limits of detection for the chromatographic procedure were established. Sample size as well as digestion acid type and amount were investigated during the microwave process. The method was applied to a variety of food matrices to evaluate its scope. Results generated with this method compare favorably to those from atomic absorption. Finally, capillary ion electrophoresis (Waters' trade name: Capillary Ion Analysis), a subset of capillary electrophoresis which has been optimized for ion analysis, was applied to the sample digests to investigate the usefulness of this technology to the analysis of mono-/divalent cations from foods.

Cations↗

Chiral separation of bupivacaine enantiomers by capillary electrophoresis partial-filling technique with human serum albumin as chiral selector.

Capillary electrophoresis (CE) is a powerful technique for enantiomer separations due to its intrinsic high separation efficiencies, speed of analysis, low reagent consumption and small sample requirements. However, some chiral selectors present strong background UV absorption providing high detection limits. The present paper deals with the application of the partial-filling technique to the separation of bupivacaine enantiomers by capillary electrophoresis using human serum albumin (HSA) as chiral selector. In this procedure the cationic surfactant cetyltrimethylammonium bromide (CTAB) was used as a dinamic capillary coating in order to reduce the electro-osmotic flow and detect both bupivacaine enantiomers out of the chiral selector plug. Several experimental conditions such as CTAB concentration, pH, HSA concentration and plug length, background electrolyte concentration, temperature and voltage were studied. Under the selected conditions it is possible to detect the separated enantiomers out of the HSA plug in less than 4 min using 50 mM Tris pH 8 as background electrolyte with 50 microM CTAB, at 30 degrees C and using a separation voltage of 25 kV. The proposed methodology was then validated for analytical purposes and applied to the analysis of pharmaceutical preparations commercially available. The results obtained with the proposed methodology were in good agreement with those declared by the manufacturers. The simplicity, sample throughput, accuracy, reproducibility and low cost of the proposed method make it suitable for the control of the enantiomeric composition of bupivacaine in pharmaceuticals.

Anesthetics, Local↗

Biologically active components of Physostigma venenosum.

Physostigmine is a major alkaloid found in the seeds of the fabaceous plant Physostigma venenosum. It is a powerful and reversible acetylcholine esterase inhibitor which effectively increases the concentration of acetylcholine at the sites of cholinergic transmission. It exerts its cholinesterase inhibitor effect in both the periphery and central nervous system. Many studies on physostigmine have involved the reliance on techniques that extract and quantify physostigmine in biological samples. This paper presents an overview of the currently applied methodologies for the determination of physostigmine and its metabolites in various biological samples. Papers published from January 1980 to December 2003 were taken into consideration for the discussion of the metabolism and analytical method of physostigmine. HPLC methods have been discussed and used in most of the references cited in this review. A few CE and RIA methods that have been recently reported are also mentioned in this paper. Basic information about the sample assayed, sample preparation, chromatographic column, mobile phase, detection mode and validation data are summarized in a table.

Chromatography, Thin Layer↗

Recent applications of sample preparation techniques in food analysis.

Even with the emergence of advanced techniques of separation and identification, it is rarely possible to analyse food without manipulation. The traditional techniques for sample preparation are time consuming and require large amount of reagents, which are expensive, generate considerable waste, contaminate the sample and can enrich it for analytes. The more analytical techniques have become highly developed, the more has sample clean-up become important in order to fully take advantage of them. Due to the multiplicity of food matrices, it is not possible to use one sample preparation technique, so many methods have been proposed for meeting all the requirements. The newest variations of wet digestion, solvent and sorbent extraction and membrane separation are summarised and their most recent applications to food analysis are provided.

Food Analysis↗

Determination of unbound etoposide concentration in ultrafiltered plasma by high-performance liquid chromatography with fluorimetric detection.

Etoposide is a highly protein bound drug, and monitoring the concentration of free drug could help individualize dosage in oncological patients. The cost and difficulty of the standard techniques (equilibration dialysis) has hampered the monitoring of free drugs. We describe a simple HPLC method for the measurement of free etoposide concentration in plasma. Sample preparation involves the ultrafiltration of plasma by a Centrifree device for 30 min at 2000 g and extraction with chloroform. The isocratic separation is performed with a mu Bondapak phenyl analytical column. Fluorimetric detection is used (288-328 nm excitation and emission wavelengths). Linearity of the calibration curve is excellent between 0.05 and 1 microgram/ml. Accuracy and precision are reported at the concentrations 0.06 and 0.4 microgram/ml: within-run accuracy is 10% and 6.2%, respectively; between-run accuracy is < or = 1%; within-run coefficients of variation (C.V.) are 10.6 and 5.0%; between-run C.V. are 11.6 and 6.8% respectively. The range of the assay is 0.05 to 1 microgram/ml. The feasibility of the technique has been tested in 7 patients treated with oral etoposide for hepatocarcinoma (mean protein binding 91%). We found no interference from endogenous substances, co-administered drugs (alizapride, furosemide, ranitidine) and other antineoplastic agents (doxorubicine, idarubicine, vinblastine, vinorelbine).

Aged↗

Optimization of separation of a complex mixture of natural and synthetic corticoids by micellar liquid chromatography using sodium dodecyl sulphate. Application to urine samples.

A systematic optimization of the separation of a mixture of corticoids by micellar liquid chromatography, using sodium dodecyl sulphate as surfactant, a Hypersil (250 mm x 3.2 mm I.D.) C18 column, a flow-rate of 0.5 ml min(-1), and UV absorbance detection at 245 nm has been carried out. Several mobile phases consisting of sodium dodecyl sulphate and different organic modifiers were tested of which tetrahydrofuran, PrOH and BuOH were finally selected. On the basis of analysis time, resolution and number of compounds separated, a mobile phase containing 36 mM sodium dodecyl sulphate and 1.91% butanol allowed the separation of thirteen corticoids out of sixteen in about 27 min. Under these conditions the optimal concentration of sodium dodecyl sulphate was found to be 36 mM. A bivariant optimization method for the mobile phase BuOH-sodium dodecyl sulphate corrobored these results. The effects of temperature, ionic strength and flow-rate effect have also been studied. The most important analytical figures of merit were assessed and compared with those obtained using conventional mobile phases. The optimized method was applied to human urine samples of subjects administered with Dezacor (tablets containing 30 mg of the active ingredient deflazacort) with and without sample preparation.

Adrenal Cortex Hormones↗

Chemiluminescence flow sensor for berberine with immobilized reagents.

A sensitive chemiluminescence (CL) sensor for berberine combined with flow-injection (FI) technology is described. The analytical reagents involved in the CL reaction, including luminol and potassium ferricyanide, were both immobilized on an anion-exchange resin column. While a volume of sodium phosphate was passed through the column, the two CL reagents were eluted from the resin and then mixed with a berberine stream under alkaline conditions. By means of the fast oxidation reaction between berberine and potassium ferricyanide, potassium ferrocyanide was generated, which then inhibited the CL reaction of luminol and potassium ferricyanide. The decreased CL intensity was correlated with the berberine concentration in the range from 0.05 to 300 ng mL(-1 )with a relative standard deviation of less than 4.3%, and the limit of detection was 0.02 ng mL(-1) at a flow rate of 2.0 mL min(-1). It was shown that the flow sensor could greatly improve the selectivity and sensitivity for determination of berberine. The determination of analyte could be performed in 2 min, including sampling and washing and be stable for over 300 analyses. Some interference and additives in preparations were tested. Two herbal medicines commonly found in compound prescriptions, rutin and baicalin, were studied preliminarily. The method has been applied for the determination of berberine in pharmaceutical preparations successfully.

Berberine↗

Evolution of a specific fluorogenic derivatization of ivermectin for bioanalytical applications. A review.

The evolution of the fluorogenic derivatization of ivermectin is traced through a series of continual modifications that have resulted in improvements in speed and sensitivity. Since the original development of this selective analytical technique, the reaction time has been shortened from 24 h at 100 degrees C to < 30 s at room temperature and, through modifications of the derivatization reagent and catalyst, the sensitivity has also been increased 50-fold to 20 pg of analyte with no significant decrease in precision. A procedure is reported, based on the use of fluorescence derivatization, which eliminates the use of solid-phase columns for sample preparation and fluorophore isolation, and is faster and less cumbersome than previous methods. The method was evaluated with cattle and canine plasma samples over the concentration range 1.0-40 ng ml-1 of ivermectin. It has an accuracy of 1.9% (mean relative error) over this concentration range and a precision of 5.6% (RSD) at the 1 ng ml-1 ivermectin concentration level in a 1 ml plasma sample.

Animals↗

Sampling and analysis considerations for the determination of hexavalent chromium in workplace air.

Airborne hexavalent chromium (Cr[VI]) is a known human respiratory carcinogen and allergen. Workers in a variety of industries may be exposed to airborne hexavalent chromium, with exposures frequently occurring via inhalation and/or dermal contact. Analytical methods for the measurement of Cr(VI) compounds in workplace samples, rather than for the determination of total elemental chromium in workplace air, are often desired because exposure limit values for Cr(VI) compounds are much lower than for total Cr. For years, sampling and analytical test methods for airborne Cr(VI) have been investigated so as to provide means for occupational exposure assessment to this highly toxic species. Inter-conversion of trivalent chromium (Cr[III]) and Cr(VI) can sometimes occur during sampling and sample preparation, and efforts to minimize unwanted redox reactions involving these chromium valences have been sought. Because of differences in toxicity, there is also interest in the ability to differentiate between water-soluble and insoluble forms of Cr(VI), and procedures that provide solubility information concerning Cr(VI) compounds have been developed. This paper reviews the state of the art concerning the measurement of airborne Cr(VI) compounds in workplace aerosols and related samples.

Air Pollution, Indoor↗

Analysis of sterol oxidation products in foods.

The main aspects related to the analysis of sterol oxidation products (SOP) in foods are comprehensively reviewed. Special emphasis is placed on the critical and controversial points of this analysis because these points affect crucial analytical parameters such as precision, accuracy, selectivity, and sensitivity. The effect of sample preparation and the conditions of quantification by gas chromatography and liquid chromatography on these parameters are also reviewed. The results show that, in order to choose an adequate method to analyze SOP in a certain food, the analyst must consider its SOP concentration and matrix complexity. The term SOP includes both cholesterol oxidation products (COP) and phytosterol oxidation products (POP). The state of the art of COP and POP analysis is quite different; many more studies have dealt with the analysis of COP than of POP. However, most of the results presented here about COP analysis may be extrapolated to POP analysis because both groups of compounds show similar structures and characteristics.

Cholesterol↗

Variation of analytical results for peanuts in energy bars and milk chocolate.

Peanuts contain proteins that can cause severe allergic reactions in some sensitized individuals. Studies were conducted to determine the percentage of recovery by an enzyme-linked immunosorbent assay (ELISA) method in the analysis for peanuts in energy bars and milk chocolate and to determine the sampling, subsampling, and analytical variances associated with testing energy bars and milk chocolate for peanuts. Food products containing chocolate were selected because their composition makes sample preparation for subsampling difficult. Peanut-contaminated energy bars, noncontaminated energy bars, incurred milk chocolate containing known levels of peanuts, and peanut-free milk chocolate were used. A commercially available ELISA kit was used for analysis. The sampling, sample preparation, and analytical variances associated with each step of the test procedure to measure peanut protein were determined for energy bars. The sample preparation and analytical variances were determined for milk chocolate. Variances were found to be functions of peanut concentration. Sampling and subsampling variability associated with energy bars accounted for 96.6% of the total testing variability. Subsampling variability associated with powdered milk chocolate accounted for >60% of the total testing variability. The variability among peanut test results can be reduced by increasing sample size, subsample size, and number of analyses. For energy bars the effect of increasing sample size from 1 to 4 bars, subsample size from 5 to 20 g, and number of aliquots quantified from 1 to 2 on reducing the sampling, sample preparation, and analytical variance was demonstrated. For powdered milk chocolate, the effects of increasing subsample size from 5 to 20 g and number of aliquots quantified from 1 to 2 on reducing sample preparation and analytical variances were demonstrated. This study serves as a template for application to other foods, and for extrapolation to different sizes of samples and subsamples as well as numbers of analyses.

Allergens↗

Simultaneous quantification of terpenelactones and flavonol aglycones in hydrolyzed ginkgo biloba extract by liquid chromatography with inline ultraviolet and evaporative light scattering detection.

We report here a liquid chromatography (LC) method with inline ultraviolet/evaporative light scattering (UV/ELS) detection for the simultaneous quantification of the terpenelactones and flavonol aglycones in a single sample of hydrolyzed Ginkgo biloba extract (GBE). The sample is hydrolyzed by a rapid and convenient oven heating method for 1 h at 90 degrees C with 10% hydrochloric acid. The 1 h hydrolysis was found to be equivalent to the 2.25 h reflux treatment for dry powder extract, where total flavonol glycosides were 28.4 and 28.1%, respectively. Acceptable precision was achieved for total terpenelactones [relative standard deviation (RSD) = 4.8%] by ELS detection, and total flavonol aglycones (RSD = 2.3%) by UV detection. The analytical range was 1.5 to 7.3% (w/w) for the individual terpenelactones (ELS) and 2.5 to 15.0% (w/w) for the individual glycosides (UV) calculated from the aglycones quercetin, kaempferol, and isorhamnetin. This improved method allows for the first time high throughput sample preparation coupled with the quantification of the predominant compounds generally used for quality control of GBE in a single assay.

Chromatography↗

A highly reproducible, linear, and automated sample preparation method for DNA microarrays.

DNA microarrays are powerful tools to detect changes in transcript abundance in multiple samples in parallel. However, detection of differential transcript levels requires a reproducible sample (target) preparation method in addition to a high-performance microarray. Therefore, we optimized a target-preparation method that converts the poly(A)(+) RNA fraction of total RNA into complementary DNA, then generates biotin-labeled complementary RNA from the cDNA. We measured the efficiency of incorporation of biotin-containing nucleotides by an enzymatic digestion, followed by resolution via analytical high-performance liquid chromatography (HPLC). When the target was hybridized to a sensitive and reproducible microarray platform, low coefficients of variation in both hybridization intensities and differential expression ratios across target preparations were observed. Nearly identical hybridization intensities and expression ratios are observed regardless of whether poly(A)(+)-enriched RNA or total RNA is used as the starting material. We show the ability to discern biological and production variability through the use of different lots of commercial samples as visualized by hierarchical clustering. Automation of the target-preparation procedure shows equivalence to the manual procedure, reproducible yields of target, and low variability as measured by hybridization to microarrays. Most importantly, RNA mixing experiments show a linear and quantitative amplification in probe hybridization signals for >6000 genes across the entire signal range.

Biotinylation↗

Genotypic selection provides experimental confirmation for an alcohol consumption quantitative trait locus in mouse.

Quantitative genetic research has produced a wealth of basic information concerning genetic influence on alcohol-related processes. Recent developments in quantitative trait locus (QTL) methodology were promptly applied to the task of individuating polygenes affecting alcohol-related attributes in animal models and a body of reliable data is gradually coming into focus as a result of replication and convergence of evidence from a variety of methods. A key issue in QTL research is the need to distinguish true positive results from the false positive results that are inherent in analytical procedures requiring large numbers of significance tests. One school of thought holds that stringent significance levels should be imposed; another suggests more modest criteria for QTL nomination, with subsequent confirmation trials with independent samples. Recombinant inbred strains and various types of intercrosses have been used in correlational designs, both for nomination and confirmation studies. Alternative experimental procedures include knockout preparations and short-term phenotypic selective breeding. We present here results from a third experimental method-that of marker-based genotypic selection--in evaluation of two nominated QTLs for alcohol acceptance in mice.

Alcohol Drinking↗

Isotachophoresis of CSF proteins in gel tubes especially gammaglobulins. An analytical and preparative technique for high-separation of CSF proteins.

An isotachophoretic method using polyacrylamide gel (PAG-ITP) in a simple disc electrophoretic equipment with plastic tubes containing the gels, was elaborated and especially designed for studying the gammaglobulins in CSF and serum from control subjects and patients with neurological disorders, especially known or probable MS. The device and the ITP system used, including leading and terminating electrolytes and spacer substances, dividing the gammaglobulins in a reproducible way, are described. No cooling of the gel tubes was needed. The sample volumes varied between 5--500 microliters, and the separation time was 1.5--3.0 h. CSF from patients with verified or probable MS revealed characteristic, increased low-mobility gammaglobulin fractions. Using other ITP systems, such as other spacer compositions, the anodic proteins can also be studied in more detail. PAG-ITP in gel tubes is a simple and inexpensive technique which can be used for both analytical and preparative procedures for biological material such as CSF, serum and extractions from nervous tissues.

Cerebrospinal Fluid Proteins↗

Simultaneous determination of coumarin, 7-hydroxycoumarin and 7-hydroxycoumarin glucuronide in human serum and plasma by high-performance liquid chromatography.

A HPLC method was developed for the determination of the metabolites of coumarin and 7-hydroxycoumarin in plasma and serum. Separation was based on gradient elution of 7-hydroxycoumarin glucuronide, 7-hydroxycoumarin, coumarin and finally 4-hydroxycoumarin (which is used as an internal standard). Standards, prepared in plasma or serum, and samples were treated with trichloroacetic acid, mixed and centrifuged. The supernatant was removed and analyzed by reversed-phase high-performance liquid chromatography on a C18 column. The limit of detection was 50 ng/ml for 7-hydroxycoumarin and 200 ng/ml for coumarin and 7-hydroxycoumarin glucuronide. The linear range was 0.5-100 micrograms/ml for each of the analytes. The percentage relative standard deviation about the mean measured concentrations were all below 10%. There was no statistical difference between the standard curves prepared in plasma or serum. The method developed was applied to the determination of each of the three compounds in serum, after the administration of 7-hydroxycoumarin, and in plasma after the administration of coumarin. The concentrations of total 7-hydroxycoumarin in the serum samples were also determined by another HPLC method and the results were compared. There was no statistical difference between the results determined.

Chromatography, High Pressure Liquid↗

An isotope-dilution gas chromatography-mass spectrometry method for trace analysis of xylene metabolites in tissues.

A gas chromatography-mass spectrometry (GC-MS) method using isotope dilution was developed to measure trace levels of xylene metabolites in brain tissues. The primary metabolites of xylene are dimethylphenol (DMP), methylbenzyl alcohol (MBA), toluic acid (TA), and methylhippuric acid (MHA). The internal standard was a mixture of deuterated DMP-d3, TA-d7, and MHA-d7. DMP-d3 was commercially available and was used as the internal standard for both DMP and MBA. TA-d7 and MHA-d7 were biosynthesized by administering xylene-d10 to rats and collecting their urine. Based on the noise peaks in 10 blank samples, the on-column limits of quantitation (mean +10 SD of noise peaks) were approximately 305, 1220, 545, and 386 pg for DMP, MBA, TA, and MHA, respectively. Analyte detection and recovery tests from brain tissues of control rats were conducted by spiking the tissues with 32 nmol/g of each analyte, together with the deuterated metabolites. The tissues were homogenized, extracted with ethyl acetate, and derivatized by trimethylsilylation. One microliter of the sample was injected into the GC-MS. The recoveries of the analytes were 104 +/- 8%, 80 +/- 9%, 93 +/- 10%, and 92 +/- 11% (mean +/- SD, n = 7) for DMP, MBA, TA, and MHA, respectively. The tissue preparation efficiency, which was indicated by absolute recoveries of internal standards, was approximately 33% for DMP, MBA, and TA and approximately 80% for MHA. No metabolites were detected in untreated control tissues. This simple and sensitive method to simultaneously detect major xylene metabolites in brain tissues could also be used for the analysis of blood and urine samples from workers to monitor p-xylene exposure.

Animals↗

Separation of proteins with a molecular mass difference of 2 kDa utilizing preparative double-inverted gradient polyacrylamide gel electrophoresis under nonreducing conditions: application to the isolation of 24 kDa human growth hormone.

A method for separating proteins with a molecular mass difference of 2 kDa using SDS-PAGE under nonreducing conditions is presented. A sample mixture containing several human growth hormone (hGH) isoforms was initially separated on a weak anion-exchange column. Fractions rich in 24 kDa hGH as determined by analytical SDS-PAGE were pooled and further separated by cation-exchange chromatography. The fractions pooled from the cation-exchange chromatography contained two hGH isoforms with a 2 kDa molecular mass difference according to SDS-PAGE analysis, 22 and 24 kDa hGH. The 22 and 24 kDa hGH were separated using continuous-elution preparative double-inverted gradient PAGE (PDG-PAGE) under nonreducing conditions. The preparative electrophoresis gel was composed of three stacked tubular polyacrylamide matrices, a 4% stacking gel, a 13-18% linear gradient gel, and a 15-10% linear inverted gradient gel. Fractions containing purified 24 kDa hGH were pooled and Western blot analysis displayed immunoreactivity to antihGH antibodies. PDG-PAGE provides researchers with an electrophoretic technique to preparatively purify proteins under nonreducing conditions with molecular mass differences of 2 kDa.

Chromatography↗