Total hip arthroplasty with bulk femoral head autograft for acetabular reconstruction in developmental dysplasia of the hip.

BACKGROUND: The long-term results of total hip arthroplasty performed with cement and use of a bulk autograft for acetabular reconstruction in patients with developmental dysplasia of the hip have varied considerably. We evaluated the results of total hip arthroplasties performed with acetabular bulk autograft to identify the factors that influence the results of this procedure. METHODS: Acetabular roof defects secondary to developmental dysplasia of the hip were reconstructed with a bulk femoral head autograft at the time of total hip arthroplasties performed with use of the Charnley technique and prosthesis. Thirty-seven hips in thirty patients (mean age at the time of the operation, fifty-seven years) were followed for ten to twenty-six years (mean, nineteen years). The Crowe classification of hip subluxation or dislocation was Group II for sixteen hips, Group III for seventeen, and Group IV for four. RESULTS: Coverage of the socket by the graft ranged from 5% to 49% (mean, 33%). Twenty-nine sockets were located within the true acetabulum, and eight were placed more proximally. At the time of the latest follow-up, all of the patients had an excellent clinical result, all of the grafts had united, and no hip had radiographic evidence of failure of the fixation. CONCLUSIONS: We found that total hip arthroplasty performed with cement and use of a bulk autograft to reconstruct an acetabulum with severe bone deficiency secondary to developmental dysplasia of the hip can provide long-term success in patients forty-eight years of age and older when coverage of the socket by the graft does not exceed 50%. When it is not possible to achieve >50% coverage of the socket by the ilium at the level of the true acetabulum, more proximal placement of the socket to obtain adequate coverage is recommended.

Acetabulum↗

Reattachment of the ununited greater trochanter following total hip arthroplasty. The use of a trochanteric claw plate.

BACKGROUND: The purpose of this retrospective study was to analyze the utility of a trochanteric claw plate in the treatment of an ununited greater trochanter following total hip arthroplasty. METHODS: From 1986 through 1999, seventy-two consecutive procedures to reattach an ununited greater trochanter were performed in seventy-one patients. The average age at the time of the index arthroplasty was 66.2 years. The arthroplasty that resulted in the nonunion of the greater trochanter was primary in fifty-four hips, a first revision in sixteen hips, and a second and third revision in one hip each. The mean duration between the hip replacement and the treatment of the nonunion was 8.1 months. The greater trochanter was fixed with the trochanteric plate alone in forty-eight hips and with the plate in conjunction with vertical wires in the remaining twenty-four hips. The average duration of follow-up was 5.1 years. RESULTS: Osseous union occurred in fifty-one of the seventy-two hips. There was a persistent nonunion in twelve hips and fibrous consolidation in the remaining nine hips. The mean time to osseous consolidation was 3.7 +/- 2.1 months (range, two to twelve months). The mean Merle d'Aubigné hip score was 16.1 +/- 2.4 points at the time of the latest follow-up. A highly significant improvement in function was achieved only in the group with osseous consolidation (p < 0.0001). The highest rate of osseous union was achieved when vertical wires had been used in conjunction with the claw plate. Union occurred in twenty-one of the twenty-four hips in that group (p = 0.025). CONCLUSIONS: Nonunion of the greater trochanter following total hip arthroplasty can be successfully treated with a trochanteric claw plate. The use of adjunctive vertical wires results in better osseous contact and union.

Adult↗

Patient satisfaction and functional status after treatment of infection at the site of a total knee arthroplasty with use of the PROSTALAC articulating spacer.

BACKGROUND: Two-stage exchange arthroplasty remains the standard treatment of infection at the site of a total knee arthroplasty. The clinical and functional outcomes associated with the use of an articulating antibiotic spacer for two-stage revision for infection are not well established. We conducted a retrospective study to evaluate the outcomes associated with the use of the PROSTALAC articulating spacer between the first and second stages. METHODS: Fifty-eight patients underwent two-stage revision total knee arthroplasty for infection between January 1997 and December 1999. Of these, fifty-four were alive at the time of follow-up and forty-seven were available for inclusion in the present retrospective study. In all patients, a prosthesis of antibiotic-loaded acrylic cement (the PROSTALAC system) was implanted during the first stage after débridement. The amount of osteolysis that occurred between the stages and the range of motion of the knee joint were measured. After two years of follow-up, outcomes were assessed with use of the WOMAC, Oxford-12, and SF-12 instruments as well as a satisfaction questionnaire. RESULTS: At a minimum of two years (average, forty-one months) after revision arthroplasty, two patients (4%) had had a recurrence of infection. The amount of bone loss was unchanged between stages, and the range of movement of the knee improved from 78.2 degrees before the first stage to 87.1 degrees at two years. The average normalized WOMAC function and pain scores were 68.9 and 77.1, respectively; the average Oxford-12 score was 67.3; the average SF-12 mental and physical scores were 53.7 and 41.2, respectively; and the average satisfaction score was 71.7. CONCLUSION: A revision operation for infection at the site of a total knee replacement with use of an articulating spacer was associated with reasonable function and satisfaction scores. These findings may be related to the articulating features of the PROSTALAC system, which permits full active movement of the knee in the early postoperative period.

Anti-Bacterial Agents↗

Total knee arthroplasty in patients with diastrophic dysplasia.

BACKGROUND: Diastrophic dysplasia results in severe disproportionate short stature, generalized joint deformities, and early osteoarthritis. The knee joint often has an abnormal valgus position and is unstable, and degeneration of all joint compartments occurs, even during growth. The purpose of our study was to evaluate the clinical and radiographic results of total knee arthroplasty in a series of patients with diastrophic dysplasia. METHODS: Between February 1992 and March 2000, twenty-one primary total knee arthroplasties were performed on fourteen consecutive patients with severe osteoarthritis due to diastrophic dysplasia. The patients were followed prospectively with clinical examinations, determination of the Hungerford knee scores, and radiographs. Preoperatively, ten knees had chronic dislocation of the patella. The mean duration of follow-up was 3.4 years. RESULTS: The mean Hungerford knee pain and total scores improved from 5.8 points and 46 points preoperatively to 50 points and 83 points, respectively, at the final follow-up examination (p < 0.001 for both comparisons). Two knees required a distal femoral corrective osteotomy because of metaphyseal angulation. None of the total knee arthroplasties had to be revised during the follow-up period. Six complications were recorded. CONCLUSIONS: Total knee arthroplasty substantially improved the function of patients with diastrophic dysplasia. Additional peripatellar procedures were commonly needed, and complications were frequent.

Arthroplasty, Replacement, Knee↗

Efficacy of intraoperative blood collection and reinfusion in revision total hip arthroplasty.

BACKGROUND: Patients undergoing revision total hip arthroplasty frequently require perioperative blood transfusion, increasing the risk for blood-borne disease and anaphylactic and hemolytic reactions. The purpose of this retrospective study was to evaluate the effect of intraoperative blood collection and reinfusion on net blood loss in patients undergoing revision hip arthroplasty. METHODS: The medical records of 126 patients who had had a revision total hip arthroplasty with intraoperative blood salvage, with use of a collection and reinfusion device, during a twenty-eight-month period were reviewed. For comparison, the medical records of ninety-six patients who had undergone revision hip arthroplasty without intraoperative blood salvage were reviewed. Each of the 222 patients was categorized into a group on the basis of the type of revision. RESULTS: Patients who had a revision of the femoral and acetabular components (Group C) had significantly higher mean intraoperative and total blood loss than did those who had a revision of the femoral component only (Group A [p = 0.009 and p = 0.02, respectively]) or a revision of the acetabular component only (Group B [p = 0.0001 for both]). Total blood loss was not significantly different between Groups A and B. The mean amount of blood reinfused intraoperatively was 356 mL for the patients in Group A, 374 mL for the patients in Group B, and 519 mL for the patients in Group C. Regression analysis showed a significant decrease in net blood loss with intraoperative collection and reinfusion in Groups B (p = 0.002) and C (p = 0.0001) but not in Group A. CONCLUSIONS: Intraoperative collection and reinfusion substantially decreased net perioperative blood loss in patients who had a revision of both components (Group C) and in those who had a revision of the acetabular component (Group B). The use of intraoperative blood collection and reinfusion appears to be a valuable method of preserving blood volume in the perioperative period.

Aged↗

Treatment of periprosthetic femoral fractures following total hip arthroplasty with femoral component revision.

BACKGROUND: Revision total hip arthroplasty is indicated for most periprosthetic fractures that occur around the stem of the femoral implant. The purpose of the present study was to assess the results and complications of revision total hip arthroplasty for the treatment of periprosthetic femoral fractures. METHODS: We evaluated 118 hips in 116 patients who underwent revision total hip arthroplasty because of an acute Vancouver type-B periprosthetic femoral fracture. The femoral implant used for the revision was a cemented stem in forty-two hips, a proximally porous-coated uncemented stem in twenty-eight, an extensively porous-coated stem in thirty, and an allograft-prosthesis composite or tumor prosthesis in eighteen. The mean duration of follow-up was 5.4 years. RESULTS: Kaplan-Meier analysis demonstrated that the probability of survival was 90% at five years and 79.2% at ten years with revision or removal of the femoral implant for any reason as the end point. Sixteen femoral components were rerevised: ten were rerevised because of loosening; three, because of loosening in association with a fracture nonunion; two, because of recurrent dislocation; and one, because of a new periprosthetic fracture. Additionally, six femoral implants were resected because of deep infection (five) or prosthetic loosening (one). Radiographs of the ninety-six hips with a surviving implant showed that twenty-one had evidence of loosening of the femoral implant, four had a nonunion of the femoral fracture, and two had both a nonunion and loosening of the femoral implant. CONCLUSIONS: Revision total hip arthroplasty for the treatment of a periprosthetic fracture around the stem of the femoral implant successfully restored function for most patients. The greatest long-term problems were prosthetic loosening and fracture nonunion. Better results were seen when an uncemented, extensively porous-coated stem was used.

Adult↗

Clinical factors associated with an increased risk of perioperative blood transfusion in nonanemic patients undergoing total hip arthroplasty.

BACKGROUND: The aim of this study was to identify clinical factors associated with an increased need for perioperative blood transfusion in nonanemic patients undergoing total hip arthroplasty. METHODS: We evaluated eighty-five consecutive nonanemic patients who underwent elective, unilateral, cementless, primary total hip arthroplasty and met our inclusion criteria. We attempted to determine whether clinical parameters influencing perioperative blood loss, such as age, gender, hypertension, and body mass index, were also associated with the need for perioperative blood transfusion. RESULTS: Perioperative blood transfusion was required in twenty-four (28%) of the eighty-five nonanemic patients. When considered alone, age, gender, hypertension, and body mass index were not significantly associated with an increased risk of perioperative blood transfusion, on the basis of the numbers available. In contrast, there was a significantly increased risk of blood transfusion when two or more of these clinical parameters were present (p = 0.02). CONCLUSIONS: Our findings indicate that clinical variables such as age, gender, hypertension, and body mass index may have a synergistic effect on the risk of transfusion in patients undergoing elective total hip arthroplasty. The simultaneous analysis of these parameters might help to stratify patients with different risks for transfusion and may increase the efficiency and reduce the cost of blood-ordering practices associated with total hip arthroplasty. LEVEL OF EVIDENCE: Prognostic study, Level II-1 (retrospective study). See Instructions to Authors for a complete description of levels of evidence.

Aged↗

Total hip arthroplasty for congenital hip disease.

BACKGROUND: It is generally agreed that the clinical and radiographic results of total hip replacement performed for degenerative arthritis secondary to congenital hip disease vary depending on the severity of the anatomical abnormality. In this study, we report the mid-term and long-term clinical and radiographic results of total hip arthroplasty performed for each of the three different types of congenital hip disease. METHODS: Between 1976 and 1994, the senior author performed 229 consecutive primary total hip arthroplasties in 168 patients with osteoarthritis secondary to congenital hip disease. Seventy-six hips were dysplastic, sixty-nine had a low dislocation, and eighty-four had a high dislocation. The Charnley low-friction technique was performed in 178 hips, and the so-called hybrid technique was performed in forty-six hips. Cementless arthroplasty was used in only five hips. RESULTS: After a minimum of seven years of follow-up, the rates of revision of the acetabular components were 15% in the dysplastic hips, 21% in the hips with a low dislocation, and 14% in those with a high dislocation. The rates of revision of the femoral components were 14%, 14%, and 16%, respectively. Survivorship analysis predicted an overall rate of prosthetic survival at fifteen years of 88.8% +/- 4.8% in the dysplastic hips, 73.9% +/- 7.2% in the hips with a low dislocation, and 76.4% +/- 8.1% in those with a high dislocation. CONCLUSIONS: An understanding of the anatomical abnormalities and the use of appropriate techniques and implants make total hip arthroplasty feasible for treatment of the three types of congenital hip disease. In patients with a low dislocation, the major technical problem is reconstruction of the natural acetabulum. In those with a high dislocation, the challenge is to place the acetabular component inside the reconstructed true acetabulum and to use an appropriate femoral implant in the hypoplastic narrow femoral diaphysis.

Adult↗

Total hip arthroplasty with bulk femoral head autograft for acetabular reconstruction in DDH. Surgical technique.

BACKGROUND: The long-term results of total hip arthroplasty performed with cement and use of a bulk autograft for acetabular reconstruction in patients with developmental dysplasia of the hip have varied considerably. We evaluated the results of total hip arthroplasties performed with acetabular bulk autograft to identify the factors that influence the results of this procedure. METHODS: Acetabular roof defects secondary to developmental dysplasia of the hip were reconstructed with a bulk femoral head autograft at the time of total hip arthroplasties performed with use of the Charnley technique and prosthesis. Thirty-seven hips in thirty patients (mean age at the time of the operation, fifty-seven years) were followed for ten to twenty-six years (mean, nineteen years). The Crowe classification of hip subluxation or dislocation was Group II for sixteen hips, Group III for seventeen, and Group IV for four. RESULTS: Coverage of the socket by the graft ranged from 5% to 49% (mean, 33%). Twenty-nine sockets were located within the true acetabulum, and eight were placed more proximally. At the time of the latest follow-up, all of the patients had an excellent clinical result, all of the grafts had united, and no hip had radiographic evidence of failure of the fixation. CONCLUSIONS: We found that total hip arthroplasty performed with cement and use of a bulk autograft to reconstruct an acetabulum with severe bone deficiency secondary to developmental dysplasia of the hip can provide long-term success in patients forty-eight years of age and older when coverage of the socket by the graft does not exceed 50%. When it is not possible to achieve >50% coverage of the socket by the ilium at the level of the true acetabulum, more proximal placement of the socket to obtain adequate coverage is recommended.

Acetabulum↗

Proximal ulnar reconstruction with strut allograft in revision total elbow arthroplasty.

BACKGROUND: The growing frequency of joint arthroplasty has led to increasing numbers of patients requiring revision surgery. In the treatment of a failed total elbow arthroplasty not associated with infection, one of the main issues is poor or absent proximal ulnar bone stock due to osteolysis. We report our experience with the use of strut allograft reconstruction of the proximal part of the ulna as an adjunct to revision total elbow arthroplasty with a noncustom implant. Our aim was to better define the indications, outcomes, and complications of this technique in a population of patients with a failed total elbow arthroplasty. METHODS: We reviewed the cases of patients with aseptic failure of a total elbow replacement and proximal ulnar bone deficiency who were treated with allograft bone struts. The patients had had an average of 2.5 (range, one to four) prior open osseous operations addressing the elbow joint. In addition to revision of the prosthetic components, the deficient bone stock was treated with allograft strut grafts in one of four ways: (1) discrete cortical defects were contained, (2) periprosthetic fractures were splinted, (3) deficient triceps attachments were reconstructed, and (4) expanded segments were augmented with struts and filled with impaction graft. Twenty-one patients (twenty-two elbows) were followed for an average of four years (range, two to eleven years). RESULTS: The mean Mayo Elbow Performance Score improved from 34 points preoperatively to 79 points at the time of the latest follow-up. The scores for pain, stability, and activities of daily living improved most; there was little change in motion. Complications, consisting of four soft-tissue and four osseous problems, occurred in eight patients. Three patients had incorporation of 26% to 50% of the graft; five, 51% to 75%; and fourteen, 76% to 100%. CONCLUSIONS: Most deficiencies of proximal ulnar bone stock and fractures complicating revision total elbow surgery can be treated with allograft strut grafting. Although the complication rate is high, this technique is suitable for discrete cortical lesions, periprosthetic fractures, and an expanded proximal part of the ulna, which also requires augmentation with impaction grafting. The technique has been unreliable, however, in restoring deficient olecranon bone stock.

Arthroplasty, Replacement↗

The outcome of total knee arthroplasty in obese patients.

BACKGROUND: Evidence linking increased body weight to osteoarthritis of the knee and the high prevalence of obesity underscore the importance of defining the outcome of total knee arthroplasty in obese patients. The purpose of this study was to compare the clinical and radiographic results of total knee arthroplasties performed in obese patients with those of total knee arthroplasties performed in nonobese patients. METHODS: Clinical and radiographic data on seventy-eight total knee arthroplasties in sixty-eight obese patients were compared with data on a matched group of nonobese patients. The analysis was also performed after stratification of the obese group for the degree of obesity. All patients had the same prosthesis. The clinical data that were analyzed included the Knee Society objective and functional scores, patellofemoral symptoms, activity level, and complications. RESULTS: The percentage of knees with a Knee Society score of > or =80 points at an average of eighty months was 88% in the obese group, which was significantly lower than the 99% rate in the nonobese group at the same time. The morbidly obese subgroup had a significantly higher revision rate than did the nonobese group (p = 0.02). CONCLUSIONS: The results of the present study suggest that any degree of obesity, defined as a body mass index of > or =30, has a negative effect on the outcome of total knee replacement.

Adult↗

Fracture of the neck of the femur after surface arthroplasty of the hip.

BACKGROUND: There are two main modes of failure of the femur following surface arthroplasty of the hip: femoral neck fracture and aseptic loosening. The purpose of the present study was to present our experience with femoral neck fractures that occurred after metal-on-metal hybrid surface arthroplasty and to assess their cause. METHODS: A series of 600 metal-on-metal surface arthroplasties was performed between late 1996 and early 2003. Failures that occurred during this period were assessed radiographically and with implant retrieval analysis to determine their cause. RESULTS: Five femoral neck fractures occurred in this series (prevalence, 0.83%). Four of the five fractures occurred at the component-neck junction within the first five months (average, three months) after surgery. All five fractures were associated with a traumatic episode, but all five also were associated with structural and/or technical risk factors, which we believe weakened the femoral neck. The most important technical deficiency that contributed to three of the five fractures was the failure to cover all of the reamed bone with the component. CONCLUSIONS: It is important to avoid or at least minimize notching of the femoral neck by performing the cylindrical reaming at the recommended angle of 140 degrees and to stop reaming before the reamer touches the lateral cortex. Osteophytes should be removed judiciously only if there is notable impingement when the hip is flexed to 90 degrees and internally rotated. We believe that understanding the factors that contribute to femoral neck fracture after surface arthroplasty may reduce the prevalence of this mode of failure.

Adult↗

Reattachment of the ununited greater trochanter following total hip arthroplasty.

BACKGROUND: The purpose of this retrospective study was to analyze the utility of a trochanteric claw plate in the treatment of an ununited greater trochanter following total hip arthroplasty. METHODS: From 1986 through 1999, seventy-two consecutive procedures to reattach an ununited greater trochanter were performed in seventy-one patients. The average age at the time of the index arthroplasty was 66.2 years. The arthroplasty that resulted in the nonunion of the greater trochanter was primary in fifty-four hips, a first revision in sixteen hips, and a second and third revision in one hip each. The mean duration between the hip replacement and the treatment of the nonunion was 8.1 months. The greater trochanter was fixed with the trochanteric plate alone in forty-eight hips and with the plate in conjunction with vertical wires in the remaining twenty-four hips. The average duration of followup was 5.1 years. RESULTS: Osseous union occurred in fifty-one of the seventy-two hips. There was a persistent nonunion in twelve hips and fibrous consolidation in the remaining nine hips. The mean time to osseous consolidation was 3.7 +/- 2.1 months (range, two to twelve months). The mean Merle d'Aubigne hip score was 16.1 +/- 2.4 points at the time of the latest follow-up. A highly significant improvement in function was achieved only in the group with osseous consolidation (p < 0.0001). The highest rate of osseous union was achieved when vertical wires had been used in conjunction with the claw plate. Union occurred in twenty-one of the twenty-four hips in that group (p = 0.025). CONCLUSIONS: Nonunion of the greater trochanter following total hip arthroplasty can be successfully treated with a trochanteric claw plate. The use of adjunctive vertical wires results in better osseous contact and union.

Aged↗

Predicting the outcome of total knee arthroplasty.

BACKGROUND: The relief of pain and the restoration of functional activities are the main outcomes of primary total knee arthroplasty for the treatment of osteoarthritis. This paper examines the preoperative predictors of pain and functional outcome at one and two years following total knee arthroplasty. METHODS: Patients were recruited for a prospective observational study of primary total knee arthroplasty for the treatment of osteoarthritis from centers in the United States, the United Kingdom, and Australia. Research assistants recruited the patients and collected the clinical history and physical examination data preoperatively and at three, twelve, and twenty-four months postoperatively. The Western Ontario and McMaster University Osteoarthritis Index (WOMAC), Short Form-36 (SF-36), and demographic data were obtained by self-administered patient questionnaires. RESULTS: We recruited 860 patients and obtained one-year WOMAC data on 759 patients (88%) and two-year data on 701 (82%). The mean age was seventy years, and 59% of the patients were female. Using hierarchical regression models, we found that the most significant preoperative predictors of worse scores on the pain and function domains of the WOMAC scale and on the physical functioning domain of the SF-36 at one and two years postoperatively were low preoperative scores, a higher number of comorbid conditions, and a low SF-36 mental health score. After adjusting for these predictors, we found that the functional status of the patients from the United Kingdom was significantly worse than that of the patients from the other countries and the difference was clinically important at both the one-year and two-year follow-up examination (p < 0.0005). The mean WOMAC pain scores for the three countries were not significantly different at one year, and, although they were significantly different at two years (p = 0.025), the difference was not clinically important. CONCLUSIONS: Patients who have marked functional limitation, severe pain, low mental health score, and other comorbid conditions before total knee arthroplasty are more likely to have a worse outcome at one year and two years postoperatively. After adjusting for these predictors, it was found that patients from the United Kingdom had significantly worse functional outcomes but similar pain relief compared with those from the United States and Australia.

Activities of Daily Living↗

Impaction grafting in revision total elbow arthroplasty.

BACKGROUND: Revision total elbow arthroplasty is often undertaken in patients who have severe osteolysis of both the distal part of the humerus and the proximal part of the ulna. To deal with such bone loss, we have adopted the practice of impaction grafting, which has become a well-established technique in the proximal part of the femur. METHODS: We retrospectively reviewed the results of twelve patients who had undergone revision total elbow arthroplasty with impaction grafting between 1993 and 1997. There were eight women and four men with a mean age of fifty-seven years. All patients were followed for at least two years (range, twenty-five to 113 months), with an average duration of follow-up of seventy-two months. Seven of the patients had an initial diagnosis of rheumatoid arthritis, and five had posttraumatic arthritis. Impaction grafting was undertaken during the initial revision in three of the patients, whereas the remaining nine patients had undergone at least one prior revision without impaction grafting. Four patients had impaction grafting on the ulnar side alone, six had it on the humeral side alone, and two underwent impaction grafting of both the humerus and the ulna. Six allograft struts were placed to span structural defects in five patients. RESULTS: At the time of the latest follow-up, eight of the elbow prostheses were intact after the index impaction grafting procedure. Two elbows had been revised because of loosening, and another had been revised because of a fracture of the ulnar component. A fourth patient had undergone a resection arthroplasty because of infection. The eight remaining patients demonstrated marked radiographic improvement in bone quality in the region of the impaction graft without clinical symptoms of loosening. At the time of the last follow-up, after an additional revision in three elbows, there were five excellent, four good, and three fair results. CONCLUSIONS: Impaction grafting is a reliable technique for treating osteolysis in patients undergoing revision total elbow arthroplasty; however, complications can occur, and a high percentage of patients need additional surgery.

Arthritis, Rheumatoid↗

Results of unicompartmental knee arthroplasty at a minimum of ten years of follow-up.

BACKGROUND: There is a renewed interest in unicompartmental knee arthroplasty. The present report describes the minimum ten-year results associated with a unicompartmental knee arthroplasty design that is in current use. METHODS: Sixty-two consecutive unicompartmental knee arthroplasties that were performed with cemented modular Miller-Galante implants in fifty-one patients were studied prospectively both clinically and radiographically. All patients had isolated unicompartmental disease without patellofemoral symptoms. No patient was lost to follow-up. Thirteen patients (thirteen knees) died after less than ten years of follow-up, leaving thirty-eight patients (forty-nine knees) with a minimum of ten years of follow-up. The average duration of follow-up was twelve years. RESULTS: The mean Hospital for Special Surgery knee score improved from 55 points preoperatively to 92 points at the time of the final follow-up. Thirty-nine knees (80%) had an excellent result, six (12%) had a good result, and four (8%) had a fair result. At the time of the final follow-up, thirty-nine knees (80%) had flexion to at least 120 degrees . Two patients (two knees) with well-fixed components underwent revision to total knee arthroplasty, at seven and eleven years, because of progression of patellofemoral arthritis. At the time of the final follow-up, no component was loose radiographically and there was no evidence of periprosthetic osteolysis. Radiographic evidence of progressive loss of joint space was observed in the opposite compartment of nine knees (18%) and in the patellofemoral space of seven knees (14%). Kaplan-Meier analysis revealed a survival rate of 98.0% +/- 2.0% at ten years and of 95.7% +/- 4.3% at thirteen years, with revision or radiographic loosening as the end point. The survival rate was 100% at thirteen years with aseptic loosening as the end point. CONCLUSIONS: After a minimum duration of follow-up of ten years, this cemented modular unicompartmental knee design was associated with excellent clinical and radiographic results. Although the ten-year survival rate was excellent, radiographic signs of progression of osteoarthritis in the other compartments continued at a slow rate. With appropriate indications and technique, this unicompartmental knee design can yield excellent results into the beginning of the second decade of use.

Aged↗

Uncemented glenoid component in total shoulder arthroplasty. Survivorship and outcomes.

BACKGROUND: Glenoid component loosening continues to be a major factor affecting the long-term survivorship of total shoulder replacements. Radiolucent lines, cement fracture, migration, and loosening requiring revision are common problems with cemented glenoid components. The purpose of this study was to evaluate the results of total shoulder arthroplasty with an uncemented glenoid component and to identify predictors of glenoid component failure. METHODS: One hundred and forty-seven consecutive total shoulder arthroplasties were performed in 132 patients (mean age, 63.3 years) with use of an uncemented glenoid component fixed with screws between 1988 and 1996. One hundred and forty shoulders in 124 patients were available for follow-up at an average of 7.5 years. One shoulder in which the arthroplasty had failed at 2.4 years and for which the duration of follow-up was four years was also included for completeness. The preoperative diagnoses included osteoarthritis in seventy-two shoulders and rheumatoid arthritis in fifty-five. RESULTS: Radiolucency was noted around the glenoid component and/or screws in fifty-three of the 140 shoulders. The mean modified ASES (American Shoulder and Elbow Surgeons) score (and standard deviation) improved from 15.6 +/- 11.8 points preoperatively to 75.8 +/- 17.5 points at the time of follow-up. Eighty-five shoulders were not painful, forty-two were slightly or mildly painful, ten were moderately painful, and three were severely painful. Fifteen (11%) of the glenoid components failed clinically, and ten of them also had radiographic signs of failure. Eleven other shoulders had radiographic signs of failure but no symptoms at the time of writing. Three factors had a significant independent association with clinical failure: male gender (p = 0.02), pain (p < 0.01), and radiolucency adjacent to the flat tray (p < 0.001). In addition, the annual risk of implant revision was nearly seven times higher for patients with radiographic signs of failure. Clinical survivorship was 95% at five years and 85% at ten years. CONCLUSIONS: The failure rates of the total shoulder arthroplasties in this study were higher than those in previously reported studies of cemented polyethylene components with similar durations of follow-up. Screw breakage and excessive polyethylene wear were common problems that may lead to additional failures of these uncemented glenoid components in the future.

Adult↗

The role of patient restrictions in reducing the prevalence of early dislocation following total hip arthroplasty. A randomized, prospective study.

BACKGROUND: It is currently unknown whether functional restrictions following total hip arthroplasty can reduce the prevalence of early postoperative dislocation. Our hypothesis was that dislocation was more likely to occur in patients who were not placed on these restrictions. METHODS: We performed a prospective, randomized study to evaluate the role of postoperative functional restrictions on the prevalence of dislocation following uncemented total hip arthroplasty through an anterolateral approach. Of the 630 eligible consecutive patients, 265 patients (303 hips) consented to be randomized into one of two groups (the "restricted" group or the "unrestricted" group). The patients in both groups were asked to limit the range of motion of the hip to <90 degrees of flexion and 45 degrees of external and internal rotation and to avoid adduction for the first six weeks after the procedure. The patients in the restricted group were instructed to comply with additional hip precautions during the first six weeks postoperatively. Specifically, these patients were managed with the placement of an abduction pillow in the operating room before bed transfer and used pillows to maintain abduction while in bed; used elevated toilet seats and elevated chairs in the hospital, in the rehabilitation facility, and at home; and were prevented from sleeping on the side, from driving, and from being a passenger in an automobile. All patients were followed for a minimum of six months postoperatively. RESULTS: There was one dislocation in the entire cohort (prevalence, 0.33%). This dislocation occurred in a patient in the restricted group during transfer from the operating table to a bed with an abduction pillow in place. Patients in the unrestricted group were found to return to side-sleeping sooner (p < 0.001), to ride in automobiles more often (p < 0.026), to drive automobiles more often (p < 0.001), to return to work sooner (p < 0.001), and to have a higher level of satisfaction with the pace of their recovery (p < 0.001) than those in the restricted group. There was an additional expenditure of approximately $655 per patient in the restricted group. CONCLUSIONS: Total hip arthroplasty through an anterolateral approach is likely to be associated with a low dislocation rate. Removal of several restrictions did not increase the prevalence of dislocation following primary hip arthroplasty at our institution. However, it did promote substantially lower costs and was associated with a higher level of patient satisfaction as patients achieved a faster return to daily functions in the early postoperative period.