Impact of dynamic airflow on human thermal response.

UNLABELLED: Airflow fluctuation is an important factor affecting indoor thermal environments and human thermal response. In this study, dynamic airflows with different fluctuation characteristics were generated by a dynamic air supply terminal. The influence of three different kinds of airflows, constant airflow, simulated natural airflow and sinusoidal airflow, on thermal comfort was studied. Subjective experiments indicated that a dynamic airflow can cause a stronger cold sensation, and that air movement with 1/f fluctuations similar to natural wind is more acceptable than other dynamic airflows in warm environments. Moreover, the impact of draughts in dynamic airflows on human thermal response is different in neutral-warm (30 degrees C) and cool-neutral (26 degrees C) thermal environments. PRACTICAL IMPLICATIONS: By means of a dynamic air supply terminal it is possible to generate artificial airflows that simulate natural wind indoors. This kind of airflow with higher velocity is more comfortable and causes less draught sensation than the constant airflows supplied by conventional fans. While the cooling effect of this airflow is utilized in the built environment, the design temperature of air-conditioning system can be increased and the amount of energy consumption can be reduced dramatically.

Adult↗

Numerical simulation of airflow patterns and air temperature distribution during inspiration in a nose model with septal perforation.

BACKGROUND: The most typical symptoms of patients with nasal septal perforation (SP) are crusting and recurrent nosebleed. The objective of the study was to determine the influence of SP on intranasal temperature profile and airflow patterns during inspiration by means of numerical simulation. METHODS: Two realistic bilateral models of the human nose with and without SP were reconstructed based on computed tomography (CT). A numerical simulation was performed. The intranasal air temperature distribution and airflow patterns during inspiration were displayed, analyzed, and compared. RESULTS: SP causes a highly disturbed airflow in the area of perforation. A spacious vortex within the perforation including various localized vortices was detected. A disturbed intranasal temperature distribution between the right and left nasal cavities developed. CONCLUSIONS: The numerical simulation demonstrates the interaction between airflow patterns and heating of respiratory air. The disturbed airflow causes reduced air conditioning. This fact may contribute to crusting and recurrent nosebleed.

Air↗

[Epidemiology of legionnaires' disease in Switzerland in 1988].

Both sporadic cases and outbreaks of legionnaire's disease have been reported. To date, no outbreaks have occurred but several case reports have been published in Switzerland. The newly organized surveillance system of notifiable diseases, introduced in 1987, makes it possible for the first time to analyze reported sporadic cases more precisely. In 1988, the laboratories reported a total of 32 cases with cultural or serologic proof of legionellosis. In 75% of cases patients were aged over 40 years, 78% occurred among males. The majority of them were known to be smokers. In 9 cases an underlying predisposing condition was known: hairy cell leukemia (3 cases), immune hemolytic anemia (1), type 2 diabetes (2), chronic lung disease (1), heart failure (1). The case fatality was 9%. A possible source of exposure, such as air-conditioned rooms or evaporative condensers, was reported in 4 cases.

Adult↗

[Fungal flora in a hospital environment].

The airborne fungal flora was studied in different departments of a hospital by using a slit sampler (Casella, London) where the measured volume of air is impacted to the surface of culture medium contained in Petri dishes. Colonies were counted after 3 days incubation at 25 degrees C and 37 degrees C. Many species of hyphomycetes were identified. The main fungi isolated were Cladosporium sp (especially C. cladosporioides), Penicillium sp., Alternaria alternata, Aspergillus sp. (A. flavus, A. niger, A. fumigatus). The results show that the variability of the spore number is related to the ventilation. The number of spores found indoors seemed proportional to those present outdoors in naturally ventilated rooms. The results are quite different in the air-conditioned wards. Also, there might be a correlation between the counts and the activity and occupation of wards.

Air Microbiology↗

[Malignant hyperthermia in a black child. A case report].

A case of malignant hyperthermia in a Black boy is presented. He developed this condition during repair of a cleft palate, with halothane as the triggering agent. The importance of the high incidence of malignant hyperthermia in patients with certain musculoskeletal abnormalities is stressed. Despite a cool and well air-conditioned theatre, the patient's temperature was 41 degree C when the condition was suspected. At that stage general muscle rigidity was present. The patient was successfully treated with procainamide, sodium bicarbonate and hydrocortisone; surface cooling (with ice packs) was instituted and the stomach was washed out with ice-cold Ringer's solution. Over a period of 14 days serum creatine phosphokinase values decreased from 630 IU (on the day of the incident) to 12 IU. A muscle biopsy showed variation in muscle fibre size. Electron microscopical studies showed myofibrillar disruption and folding of the basement membrane. A modified version of Denborough's technique was used for the in vitro exposure of muscle strips to halothane and suxamethonium. Isometric contraction was measured and recorded. A severe contraction followed the exposure of muscle strips to halothane, which confirmed the diagnosis.

Child↗

Development of a pregnancy policy for air medical personnel: an administrative approach.

Pregnancy of air medical personnel poses a unique challenge for the administration of air medical services. Pregnant staff vary in their approach to individual pregnancy and their desire to continue flight duties. Administrators are limited to actions that ensure optimal care for the patient regardless of the caregivers' health or condition. Air medical programs must balance what is acceptable for patient care and safety with what are legally acceptable practice restrictions. The Staff For Life helicopter service uses experts in obstetric care to evaluate the pregnant staff members' abilities to perform pre-determined physical duties associated with air medical care. A signed consent form acknowledging risk factors associated with air medical care ensures that the flight staff member has had a frank and honest discussion with her physician. The obstetric evaluation and consent form confirm for program administration a pregnant flight staff member's ability to function within her role and removes all ambiguity from the process.

Air Ambulances↗

Toxicity of cyanoacrylate adhesives and their occupational impacts for dental staff.

Cyanoacrylate (CA) and its homologues have a variety of medical, dental and commercial applications as adhesives. The increasing use of CA in dentistry, particularly as an adhesive and sealing glue, has raised concerns regarding its potential toxicity in humans. Reported toxicity of CA is uncommon in the dental workplace, but may manifest as conditions such as urticaria, contact dermatitis and other dermatoses. Dental staff using CA adhesives should avoid direct contact with CA and use appropriate personal protective measures. Maintaining higher levels of humidity, optimizing room ventilation and using special air conditioning filters in the working environment may be useful in minimising the toxicity of volatile CA adhesives.

Animals↗

A descriptive cross-sectional study of annoyance from low frequency noise installations in an urban environment.

In order to improve the living conditions for respondents highly exposed to traffic noise, it has been recommended that one side of the building should face a "quiet side". Quiet may, however, be spoilt by noise from installations such as ventilation and air-conditioning systems. The noises generated by installations of this kind often have a dominant portion of low frequencies (20-200 Hz) and may be a source of great annoyance and sleep disturbance. This paper describes the cross-sectional part of an intended intervention study among residents exposed to traffic noise on one side of the building and to low frequency noise from installations on the other side of the building. A questionnaire masked as a general living environment study was delivered to a randomly selected person in each household. In total 41 respondents answered the questionnaire (71% response rate). Noise from installations was measured indoors in a bedroom facing the courtyard in a selection of apartments and outdoors in the yard. 24h traffic noise outdoor and indoor levels were calculated. The noise levels from installations were slightly above or at the Swedish recommendations for low frequency noise indoors with the window closed and exceeded the recommendations by about 10 dB SPL when the window was slightly opened. The proportion of persons who reported that they were very or extremely annoyed indoors from noise from installations was more than twice as high as for traffic noise. Installation noise also affected respondents' willingness to have their windows open and to sleep with an open window. The high disturbance of installation noises found in this study indicates the importance of also regulating the noise exposure on the "quiet side" of buildings. Further studies will give a better base for the extent of annoyance and acceptable levels of installation noises.

Adult↗

Consequences of prolonged total body immersion in cold water on muscle performance and EMG activity.

The consequences of a prolonged total body immersion in cold water on the muscle function have not been documented yet, and they are the object of this French Navy research program. Ten elite divers were totally immerged and stayed immobile during 6 h in cold (18 and 10 degrees C) water. We measured the maximal voluntary leg extension (maximal voluntary contraction, MVC) and evoked compound muscle potential (M wave) in vastus lateralis and soleus muscles at rest, after a submaximal (60% MVC) isometric extension allowing the measurement of the endurance time (Tlim). The power spectrum of surface electromyograms (EMG) was computed during 60% MVCs. MVCs and 60% MVC maneuvers were repeated four times during the immersion. Data were compared with those obtained in a control group studied in dry air condition during a 6-h session. Total body cooling did not affect MVC nor Tlim. The M wave duration increased in the coolest muscle (soleus), but only at 10 degrees C at rest. There were no further fatigue-induced M wave alterations in both muscles. During 60% the MVCs, a time-dependant increase in the leftward shift of the EMG spectrum occurred at the two temperatures. These EMG changes were absent in the control group of subjects studied in dry air. The plasma lactate concentration was elevated throughout the 18 and mostly the 10 degrees C immersion conditions. Throughout the 18 degrees C immersion study, the resting potassium level did not significantly vary, whereas at 10 degrees C, a significant potassium increase occurred soon and persisted throughout the study. Thus, total body immersion in cold water did not affect the global contractile properties of leg muscles during static efforts but elicited significant alterations in electromyographic events which may be related to the variations of interstitial fluid composition.

Adult↗

A low-CO2-inducible gene encoding an alanine: alpha-ketoglutarate aminotransferase in Chlamydomonas reinhardtii.

At low-CO2 (air) conditions, the unicellular green alga Chlamydomonas reinhardtii acquires the ability to raise its internal inorganic carbon concentration. To study this adaptation to low CO2, cDNA clones induced under low-CO2 growth conditions were selected through differential screening. One full-length clone is 2552 bp, with an open reading frame encoding 521 amino acids. The deduced amino acid sequence shows about 50% identity with alanine: alpha-ketogutarate aminotransferase (Ala AT, EC 2.6.1.2) from plants and animals, and the mRNA of this clone increased 4- to 5-fold 4 h after cells were switched from high-CO2 to low-CO2 growth conditions. The expression of the enzyme and its activity also increased accordingly at low-CO2 growth conditions. To study the physiological role of Ala AT, a pyridoxal phosphate inhibitor, aminooxyacetic acid, was added at 40 microM to the growth medium when cells were beginning to adapt to low CO2. This caused a 30% decrease in the maximum photosynthetic rate in air-adapting cells 8 h later. The addition of the inhibitor also caused the cells to excrete glycolate, a photorespiratory intermediate, but did not change the apparent affinity of the cell for external CO2. These physiological studies are consistent with the assumption that Ala AT is involved in the adaptation to low-CO2 conditions.

Adaptation, Biological↗

Indoor and outdoor formaldehyde concentrations in homes in residential areas in Greater Cairo.

Indoor and outdoor measurements of formaldehyde were conducted at seven flats located in residential areas in Greater Cairo, during spring and summer seasons 1999. The mean daytime formaldehyde concentrations in kitchens, bedrooms and living rooms were 89, 100 and 100 ppb, respectively, in the seven flats. Significant positive correlations were found between the concentrations of formaldehyde found in these three rooms. On the other hand, no significant differences were found between the mean formaldehyde concentrations in these three rooms. The maximum mean concentration of formaldehyde (147 ppb) was recorded in a new flat, while the minimum concentration (43 ppb) was observed in an old flat. The maximum hourly and daytime concentrations were 350 and 225 ppb, respectively. Air temperature, relative humidity and the age of the flat are factors affecting the emission and concentration of formaldehyde. The maximum indoor and outdoor formaldehyde concentrations were recorded during the summer season. During the spring, 38% of the samples indicated that the concentration of formaldehyde in the seven flats exceeded 0.1 ppm, the American Society of Heating, Refrigerating, and Air Conditioning Engineers' (ASHRAE) standard; in the summer, this figure increased to 53%.

Air Pollution, Indoor↗

Nitrous oxide pollution levels in oral surgery offices.

Nitrous oxide pollutant levels, surveyed in oral surgery offices in Southern California, were lower than previously reported. These evaluations were related to rebreathed gas samples obtained from the operator and assistants, and appear to correlate well with exposure to nitrous oxide contamination. The lower levels in the hallway were tenfold less than those previously reported. Better air-conditioning in these offices and better airway control could be responsible, in part, for the difference.

Air Pollutants↗

Nocturnal oxygen enrichment of room air at 3800 meter altitude improves sleep architecture.

Sleep is known to be impaired at high altitude, and this may be a factor contributing to reduced work efficiency, general malaise, and the development of acute mountain sickness (AMS). Nocturnal room oxygen enrichment at 3800 m has been shown to reduce the time spent in periodic breathing and the number of apneas, to improve subjective quality of sleep, and to reduce the AMS score. The present study was designed to evaluate the effect of oxygen enrichment to 24% at 3800 m (lowering the equivalent altitude to 2800 m) on sleep architecture. Full polysomnography and actigraphy were performed on 12 subjects who ascended in 1 day to 3800 m and slept in a specially constructed room that allowed oxygen enrichment or ambient air conditions in a randomized, crossover, double-blind study. The results showed that subjects spent a significantly greater percentage of time in deep sleep (stages III and IV combined, or slow wave sleep) with oxygen enrichment versus ambient air (17.2 +/- 10.0% and 13.9 +/- 6.7%, respectively; p < 0.05 in paired analysis). No differences between treatments were seen with subjective assessments of sleep quality or with subject's assessment of the extent to which they suffered from AMS. This study provides further objective evidence of improved sleep as a result of oxygen enrichment at 3800 m and suggests that alleviating hypoxia may improve sleep quality.

Adult↗

Ambient air quality standards.

Conceptual methods of setting national ambient air quality standards in Japan are discussed in comparison with case of occupational exposure limits in industrial health. The air quality standards are set by the national government, based on recommendations of the Central Council on Countermeasures for Environmental Pollution, in conformity with the Fundamental Act on Countermeasures for Environmental Pollution. In setting the standard values, thresholds and the existence of specific groups in the people with high susceptibility to a certain pollutant are taken into account. The standards are set following minimum effect reports in three branches of health effect studies on air pollution: animal experiments, human exposure, and epidemiology. Safe levels take into account the absence of effects, suspicion of irreversible effects, dwellings of the elderly/infant/sick, epidemiologic growth of nonspecific diseases such as asthma, and so on. Under these conditions, air quality standards become far severer than in the case of industrial health limits.

Air Pollutants↗

Intraluminal "balloonless" air tonometry: a new method for determination of gastrointestinal mucosal carbon dioxide tension.

OBJECTIVE: To determine if air introduced directly into the lumen of a hollow viscus can be used instead of fluid in a Silastic balloon to estimate gastrointestinal mucosal PCO2. DESIGN: Prospective, unblinded comparison of two methods of mucosal PCO2 measurement. SETTING: Animal surgery suite at a large, university-affiliated medical center. INTERVENTIONS: Standard, commercially available, tonometric catheters were positioned in the ileum (n = 4) or the stomach and ileum (n = 12) of anesthetized, immature Yorkshire swine. Using gas-tight purse-string sutures, plastic cannulas were inserted into the lumen of the stomach (n = 12) and the lumen of a 10-cm isolated segment of ileum (n = 16). Data were collected after equilibration periods of 30 or 60 mins. Before each equilibration period, the "air tonometers" (i.e., the lumens of the stomach and/or the isolated ileal segment) were lavaged with 200 mL (stomach) or 20 mL (ileum) of air. In group 1 (n = 4) and group 2 (n = 3), graded degrees of mesenteric hypoperfusion were achieved by mechanical mesenteric occlusion or pericardial tamponade, respectively. In group 3 (n = 8), graded degrees of respiratory acidosis were induced. At various intervals, PCO2 was determined simultaneously in arterial blood, gastric air, saline from the gastric tonometric balloon, ileal air, and saline from the ileal tonometric balloon. MEASUREMENTS AND MAIN RESULTS: In pigs with ischemia created by mesenteric vascular occlusion (group 1), there was a moderate correlation between PCO2 values in air samples from the ileal lumen and samples of saline from the standard tonometer (r2 = .61, p < .001). In pigs with mesenteric ischemia secondary to pericardial tamponade (group 2), air and saline tonometry were well-correlated in the stomach (r2 = .71, p < .001) and ileum (r2 = .83, p < .001). In pigs with normal mesenteric perfusion (group 3) and PaCO2 > 40 torr (5.3 kPa), PaCO2 correlated with ileal mucosal PCO2, determined using air (r2 = .93, p < .001) or saline (r2 = .91, p < .001) tonometry, or gastric mucosal PCO2, determined using air (r2 = 1.00, p < .001) or saline (r2 = .97, p < .001) tonometry. Values obtained by air tonometry were highly correlated with values obtained using standard saline tonometry in the stomach (r2 = .98, p < .001; bias = -5 +/- 5 torr [-0.65 +/- 0.65 kPa]) or ileum (r2 = .96, p < .001; bias = 1 +/- 9 torr [0.13 +/- 1.17 kPa]). CONCLUSIONS: a) Under stable hemodynamic and respiratory conditions, air tonometry (which, in theory, can be performed using a conventional nasogastric or nasoenteric feeding tube) estimates gastrointestinal mucosal PCO2 as accurately as standard saline tonometry in the stomach or ileum; b) respiratory acidosis leads to tissue hypercarbia, a phenomenon that must be considered when tonometry is used to guide therapy in the clinical setting; c) under stable, nonischemic conditions, gastric or intestinal tonometry can be used to estimate PaCO2.

Acidosis↗

Kiln emissions and potters' exposures.

Some ten thousand British Columbia potters work in small private studios, cooperative facilities, educational institutions, or recreation centers. There has been considerable concern that this diffuse, largely unregulated activity may involve exposures to unacceptable levels of kiln emissions. Pottery kiln emissions were measured at 50 sites--10 from each of 5 categories: professional studios, recreation centers, elementary schools, secondary schools, and colleges. Area monitoring was done 76 cm from firing kilns and 1.6 m above the floor to assess breathing zone concentrations of nitrogen dioxide, carbon monoxide, sulfur dioxide, fluorides, aldehydes, aluminum, antimony, arsenic, barium, beryllium, boron, cadmium, chromium, cobalt, copper, gold, iron, lead, lithium, magnesium, manganese, mercury, nickel, selenium, silver, vanadium, and zinc. Personal exposures to the same metals were measured at 24 sites. Almost all measured values were well below permissible concentrations for British Columbia work sites and American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit values (TLVs) with the following two exceptions. A single firing duration (495 minute) acrolein measurement adjacent to an electric kiln (0.109 ppm) exceeded these guidelines. One 15-minute sulfur dioxide measurement collected adjacent to a gas kiln (5.7 ppm) exceeded the ACGIH short-term exposure limit. The fact that concentrations in small, ventilated kiln rooms ranked among the highest measured gives rise to concern that unacceptable levels of contamination may exist where small kiln rooms remain unventilated. Custom designed exhaust hoods and industrial heating, ventilating, and air-conditioning systems were the most effective ventilation strategies. Passive diffusion and wall/window fans were least effective.

Aerosols↗

Fungal production of volatiles during growth on fiberglass.

Acoustic and thermal fiberglass insulation materials used in heating, ventilation, and air-conditioning systems were colonized with fungi in laboratory chambers. The mixed fungal population, principally Aspergillus versicolor, Acremonium obclavatum, and Cladosporium herbarum, produced odoriferous volatiles, including 2-ethyl hexanol, cyclohexane, and benzene. These volatiles may be related to poor indoor air quality and the sick building syndrome.

Acremonium↗

Interstital lung disease due to contamination of forced air systems.

Eight patients had hypersensitivity pneumonitis due to contaminated home or office forced-air heating or air-conditioning systems. We studied their clinical and laboratory features, and the results indicated that this disease may occur as an acute or insidious form differing in type and intensity of respiratory and systemic symptoms. Thermophilic actinomycetes contaminatinf the forced air systems were identified as the sensitizing agents in most cases. Precipitating antibodies to the organisms could be shown in the serums of the patients and the antigen identified by immunofluorescent studies in the three lung biopsies examined by this method. Inhalation challenge studies with the cultured organism or other materials obtained from the forced air systems reproduced the clinical syndrome in the four patients tested. Avoidance of the contaminated system, and the use of corticosteroids in more severe cases,seems to be appropriate therapy for patients with this disease.