Analysis of a bioactive beta-(1 --> 3) polysaccharide (Curdlan) using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

This paper focuses on the development of MALDI sample preparation protocols for the analysis of a bioactive beta-(1 --> 3) polysaccharide, i.e. Curdlan. The crude Curdlan sample was first separated into a low molecular weight water-soluble portion and a high molecular weight water-insoluble portion. The water-soluble portion was analyzed using a standard MALDI sample preparation method developed for dextran analysis. Two low-mass (<4000 Da) polysaccharide distributions differing by 16 Da were observed. For the analysis of the water-insoluble portion, several sample preparation protocols were evaluated using GPC-fractionated samples. A sample preparation method based on the deposition of the analyte solution with a mixture of 2,5-dihydroxybenzoic acid (DHB) and 3-aminoquinoline (3AQ) matrices in dimethyl sulfoxide (DMSO) at elevated temperature of 70 degrees C was found to reliably produce good MALDI spectra. MALDI analysis of the water-insoluble Curdlan portion gave number-average (Mn) and weight-average (Mw) molecular weights and polydispersity of 8000 Da, 8700 Da, and 1.10, respectively.

Alcaligenes↗

Effectiveness of chemical etching for background electron paramagnetic resonance signal reduction in tooth enamel.

A method of preparing enamel samples for electron paramagnetic resonance retrospective dosimetry that leads to a reduction of the non-radiation induced signals (background) is proposed. The method is effective in removing residual dentin and in reducing surface paramagnetic centers both native and induced by the sample preparation procedure. The main steps in the method are the use of longwave length ultraviolet light for distinguishing dentin from enamel and of chemical etching with phosphoric acid for removal of surface paramagnetic centers. Several acid concentrations and etching times were tested and the optimization of the method is illustrated in regard to both sample mass loss and background signal amplitude reduction. The best acid concentration was determined to be 42%, leading to a 30% reduction in the background electron paramagnetic resonance signal amplitude per unit mass.

Acid Etching, Dental↗

Parallel DNA template preparation using a vacuum filtration sample transfer device.

Solid-phase techniques have facilitated the handling of biochemical analytes. This has stimulated the development of systems by which large sample panels can be analyzed with high levels of security and quality. We describe a sample transfer device based on the principle of vacuum filtration, which enables parallel handling of 96 samples of analytes bound to Sepharose beads. The tool was employed for strand separation of DNA samples, by attracting the beads to filter probes while passing them between the reagent solutions. The samples were analyzed using Pyrosequencing technology and proved to yield genotyping results of high quality. The presented sample preparation procedure provides an important link in the development of integrated systems for rapid genetic analysis at a low cost. In addition, the same filter could be reused extensively with very low risk for detectable cross-contamination between assays and without any reduction in processing capacity, thus further reducing the cost per analyzed sample.

DNA↗

Three-layer matrix/sample preparation method for MALDI MS analysis of low nanomolar protein samples.

A robust and sensitive sample preparation method is presented for matrix-assisted laser desorption ionization (MALDI) mass spectrometric analysis of low nanomolar concentrations of proteins containing high amounts of common salts and buffers. This method involves the production of densely packed sub-micrometer matrix crystals by depositing a matrix solution on top of a matrix seed-layer prepared on a MALDI target. A sub-microliter aliquot of analyte solution is then directly added to the top of the matrix crystals to form a thin-layer. alpha-Cyano-4-hydroxycinnamic acid (4-HCCA) is used as matrix and demonstrated to give better performance than other commonly used matrices, such as 2,5-dihydroxybenzoic acid (DHB), 2-(4-hydroxy-phenylazo) benzoic acid (HABA), or sinapinic acid. This three-layer method is shown to be superior to the other MALDI sample preparation methods, particularly for handling low nanomolar protein solutions containing salts and buffers.

Animals↗

High-performance liquid chromatographic determination of drugs and metabolites in human serum and urine using direct injection and a unique molecular sieve.

Silicalite is a molecular sieve that contains an intricate system of channels approximately 6 A in diameter. These channels are hydrophobic and have been shown to retain relatively small hydrophobic and hydrophilic molecules from aqueous and biological samples. Silicalite is shown to be a restricted-access medium that permits the injection of biological fluids directly onto a HPLC column packed with Silicalite, eliminating the need for sample preparation. The sample macromolecules elute with high recovery mostly at the extraparticulate void. Simultaneously, Silicalite allows various drugs and metabolites to enter the channels and be retained. Recoveries >90% were generally obtained for a wide variety of drugs and their metabolites from human serum and urine.

Blood↗

High-resolution image analysis.

In many departments of cytology, cytogenetics, hematology, and pathology, research projects using high-resolution computerized microscopy are now being mounted for computation of morphometric measurements on various structural components, as well as for determination of cellular DNA content. The majority of these measurements are made in a partially automated, computer-assisted mode, wherein there is strong interaction between the user and the computerized microscope. At the same time, full automation has been accomplished for both sample preparation and sample examination for clinical determination of the white blood cell differential count. At the time of writing, approximately 1,000 robot differential counting microscopes are in the field, analyzing images of human white blood cells, red blood cells, and platelets at the overall rate of about 100,000 slides per day. This mammoth through-put represents a major accomplishment in the application of machine vision to automated microscopy for hematology. In other areas of automated high-resolution microscopy, such as cytology and cytogenetics, no commercial instruments are available (although a few metaphase-finding machines are available and other new machines have been announced during the past year). This is a disappointing product, considering the nearly half century of research effort in these areas. This paper provides examples of the state of the art in automation of cell analysis for blood smears, cervical smears, and chromosome preparations. Also treated are new developments in multi-resolution automated microscopy, where images are now being generated and analyzed by a single machine over a range of 64:1 magnification and from 10,000 X 20,000 to 500 X 500 in total picture elements (pixels). Examples of images of human lymph node and liver tissue are presented. Semi-automated systems are not treated, although there is mention of recent research in the automation of tissue analysis.

Blood Cell Count↗

Focused ion beam in dental research.

Focused ion beam (FIB) has been available for over 10 yrs but until recently its usage has been confined to the semiconductor industry. It has been developed as an important tool in defect analysis, circuit modification and recently transmission electron microscope sample preparation. This paper introduces FIB and demonstrates its application in dental research. Its ion and electron imaging modes complement the SEM while its ability to prepare TEM samples from a wide range of material will allow the study of new types of adhesive interface. As an example, its use is described in the characterization of the interface of resin to a tribochemically treated surface of an experimental fiber-reinforced resin-based composite. As with all new techniques, the initial learning curve was difficult to manage. This new instrument offers opportunities to expand research in dental materials to areas not possible before.

Aluminum Oxide↗

Solid-phase microextraction combined with surface-enhanced laser desorption/ionization introduction for ion mobility spectrometry and mass spectrometry using polypyrrole coatings.

The successful application of polypyrrole (PPY) solid-phase microextraction (SPME) coatings as both an extraction phase and a surface to enhance laser desorption/ionization (SELDI) of analytes is reported. This SPME/SELDI fiber integrates sample preparation and sample introduction on the tip of a coated optical fiber, as well as acting as the transmission medium for the UV laser light. Using ion mobility spectrometry (IMS) detection, the signal intensity was examined as a function of extraction surface area and concentration of analyte. The linear relationship between concentration and signal intensity shows potential applicability of this detection method for quantitative analysis. Extraction time profiles for the fiber, using tetraoctylammonium bromide as test analyte, illustrated that equilibrium can be reached in less than one minute. To investigate the performance of the PPY coating, the laser desorption profile was studied. The fiber was also tested using a quadrupole time-of-flight (Q-TOF) mass spectrometer with leucine enkephalin as test analyte. Since no matrix was used, mass spectra free from matrix background were obtained. This novel SPME/SELDI fiber is easy to manufacture, and is suitable for studying low-mass analytes because of the intrinsic low background. These findings suggest that other types of conductive polymers could also be used as an extraction phase and surface to enhance laser desorption/ionization in mass spectrometry.

Journal Article↗

Liquid supports for ultraviolet atmospheric pressure matrix-assisted laser desorption/ionization.

Atmospheric pressure (AP) liquid matrices for ultraviolet (UV) matrix-assisted laser desorption/ionization (MALDI) are presented. Doping a known organic chromophore, alpha-cyano-4-hydroxycinnamic acid (CHCA), into liquid media yielded a homogenous sample system with simplified sample preparation, increased sample lifetime, and added utility for APMALDI ion sources. Compared with vacuum situations, AP matrices are not as limited by vapor pressure, so liquid matrix formulations can focus on desorption and ionization versus vacuum stability and source contamination. The parameters studied include chromophore concentration, liquid support variations, and quantitation capability. Chromophore concentration adjustments provided insight into the necessary absorbance for UV-APMALDI and demonstrated the importance of laser penetration depth. Liquid support variations allowed adjustments of sample lifetime and analyte solvents. Extended sample lifetime is beneficial for instrument tuning and source optimization; however, increased liquid viscosity lowers signal intensity. The shot-to-shot reproducibility, as examined with individual ion packets, suggests that the liquid matrix can alleviate some inconsistencies seen with solid MALDI, suggesting a possibility for better quantitation. The measurements for laser penetration depth, solution viscosity, and solvent additives could add to the information on MALDI mechanisms. The liquid matrix offers advantages that complement current MALDI methods.

Atmospheric Pressure↗

Trace determination of anthracyclines in urine: a new high-performance liquid chromatography/tandem mass spectrometry method for assessing exposure of hospital personnel.

Health-care workers handling antineoplastic agents may be exposed to extremely low doses of these drugs. Very sensitive and specific analytical methods are therefore needed for biological monitoring. The aim of this study was to develop and validate a method for trace level determination of doxorubicin, epirubicin, daunorubicin and idarubicin in human urine, using epi-daunorubicin as an internal standard. Solid-phase extraction (SPE) was used for sample preparation. Urine samples were loaded onto Bond Elut C18 cartridges. The analytes were eluted in methylene chloride/2-propanol (1:1, v/v) and then evaporated to dryness. The residue was reconstituted with the mobile phase prior to high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) analysis. Quantitation of each analyte was performed using the multiple reaction monitoring (MRM) method. The urine assay was linear over the range 0.1-2.0 microg/L, with a lower limit of quantification (LLOQ) of 0.10 microg/L for doxorubicin and epirubicin, and 0.03 microg/L for daunorubicin and idarubicin. The respective limits of detection (LODs) were 0.04 and 0.01 microg/L. The precision and accuracy of the assay were determined on three different days. The within-series precision was found to be always less than 13.9% for all the analytes. The overall precision expressed as relative standard deviation (RSD) was always less than 10.6%. The recovery of anthracyclines was assessed at two concentrations of the range tested (0.1 and 2.0 microg/L) and it ranged from 87.7% (daunorubicin) to 102.0% (doxorubicin) and from 79.1% (daunorubicin) to 90.7% (idarubicin) for the lower and the higher level, respectively, with a RSD always less than 9.1%. The uncertainty of the present assay was also evaluated and the combined uncertainty was always less than 20% over all the days of the validation study. This is the first method that makes use of LC/MS/MS for the biological monitoring of occupational exposure to anthracyclines.

Anthracyclines↗

Determination of serum cortisol using isotope dilution-liquid chromatography-mass spectrometry as a candidate reference method.

We propose isotope-dilution mass spectrometry as a candidate reference method for determination of serum cortisol. The method uses liquid chromatography-mass spectrometry (LC-MS), interfaced with electrospray ionization, and selective monitoring of the [M + H]+ ions of cortisol and isotopically labeled cortisol. The isotope-dilution-liquid chromatography-mass spectrometry (ID-LC-MS) method simplifies sample-preparation, because samples are processed by simple solvent extraction without further clean-up and derivatization. We studied the time required for complete equilibration of endogenous cortisol and labeled cortisol spiked into serum and found it to be less than 1 h. The repeatability and the reproducibility of the method were evaluated and found to be 0.55% of the measurement value. CRM 192 and 193 from the Bureau Communautaire de Reference were analyzed for verification of the method. The results obtained from the ID-LC-MS method agreed with the certified values. The relative uncertainty of measurement results for samples in the range of a few tens of micrograms per kilogram to several hundred micrograms per kilogram was evaluated and found to be 0.56%. Immunoassay carried out by three independent clinical laboratories produced results more than 15% higher than this ID-LC-MS method, suggesting the presence of bias in the immunoassay methods.

Gas Chromatography-Mass Spectrometry↗

Determination of trace elements in suspensions and filtrates of drinking and surface water by wavelength-dispersive X-ray fluorescence spectrometry.

An X-ray fluorescence method (XRF) is presented that allowed low detection limits (at the 0.1-23 ng mL(-1) level) to be obtained for Cr, Mn, Fe, Ni, Zn, Sr, Pb, Bi and Br in water. The samples were prepared using a thin layer method. Trace elements were determined via the calibration curve and standard addition. Absorption effects and inhomogenities in prepared samples were checked for using the emission-transmission method and internal standards, respectively. The results from the XRF method were compared with the results from the inductively coupled plasma atomic emission spectrometry method.

Journal Article↗

Microbial detection with low molecular weight RNA.

The need to monitor microorganisms in the environment has increased interest in assays based on hybridization probes that target nucleic acids (e.g., rRNA). We report the development of liquid-phase assays for specific bacterial 5S rRNA sequences or similarly sized artificial RNAs (aRNAs) using molecular beacon technology. These beacons fluoresce only in the presence of specific target sequences, rendering as much as a 27-fold fluorescence enhancement. The assays can be used with both crude cell lysates and purified total RNA preparations. Minimal sample preparation (e.g., heating to promote leakage from cells) is sufficient to detect many Gram-negative bacteria. Using this approach it was possible to detect an aRNA-labeled Escherichia coli strain in the presence of a large background of an otherwise identical E. coli strain. Finally, by using a longer wavelength carboxytetramethylrhodamine beacon it was possible to reduce the fraction of the signal due to cellular autofluorescence to below 0.5%.

Biomarkers↗

Transfer of membrane proteins from human platelets to liposomal fraction by interaction with liposomes containing an artificial boundary lipid.

The direct transfer of membrane proteins from human platelets to the liposomal fraction was examined, particularly in relation to platelet activation during the process. The incorporation of an artificial boundary lipid, 1,2-dimyristoylamido-1,2-deoxyphosphatidylcholine (DDPC), in the interacting liposome considerably enhanced the efficiency of the protein transfer. The transfer proceeded with neither significant activation nor lysis of the platelet, and the activation of the platelet with thrombin did not affect the amount of the transferred proteins. A wide range of platelet membrane proteins was transferred, and they were almost comparable to those in a sample prepared by glycerol lysis/centrifugation. In addition, they included the major surface glycoproteins GPIIb and GPIIIa without noticeable contamination of soluble cytosol proteins. The protein transfer method is a one-pot process and clearly more convenient than the conventional 'extract and reconstitute' approach. These results strongly support the use of the transfer process, especially with DDPC, as an alternative to the conventional detergent-solubilization or the solvent-extraction methods for preparation of samples of platelet membrane proteins.

Blood Platelets↗

Fully automated analytical system using liquid-solid extraction and liquid chromatography for the determination of CGP 6140 in plasma.

Liquid-solid extraction on disposable extraction columns (DECs) and liquid chromatography can be combined in a completely automated analyser. The Gilson ASPEC system was used to develop a procedure for the determination of CGP 6140 in plasma. Both sample preparation via C8 Bond-Elut DECs and injection were fully automatic. The fully automated system prepared the samples by performing the same operations as for a manual procedure. The DEC was first wetted with methanol, then with water. A 400-microliters volume of plasma and 40 microliters of the internal standard solution, diluted with 1 ml of water, were applied to the DEC, rinsed with 10(-2) mol/l dipotassium hydrogenphosphate and eluted from the DEC with 300 microliters of acetonitrile-methanol (50:50, v/v). The eluting strength of the eluate was reduced by dispensing 1 ml of water into each vial prior to direct injection into a Spherisorb ODS column via a 1-ml loop. This allowed the reconcentration of the extracted compounds on the top of the column, as they were injected in a large volume of solvent of lower eluting strength than the mobile phase [acetonitrile-methanol-4 x 10(-3) mol/l ammonia solution (54.5:5:40.5, v/v/v)]. Reproducibility results are presented.

Chemical Phenomena↗

Measurement of PAF in blood by radioimmunoassay. Examination of interfering factors and problems involved in accurate quantification.

A recently developed radioimmunoassay for PAF was applied to blood extracts with the aims of defining and overcoming problems that lead to erroneous results and establishing optimum conditions for the accurate determination of PAF levels. The high lipid content of blood was found to interfere with the assay, and it appeared that phosphatidylcholine and/or sphingomyelin might be among the lipids responsible. Interference was eliminated by either dilution or preparative TLC of blood extract prior to RIA although dilution is unlikely to be generally useful due to the low amounts of PAF normally present in human blood. Lipid extraction of whole blood followed by preparative TLC proved to be necessary in the preparation of samples prior to performance of the RIA. The problems encountered in the measurement of PAF levels in blood by RIA highlight the importance of determining the correct method of sample preparation for any tissue/fluid prior to its inclusion in the assay.

Chromatography, Thin Layer↗

Human IgG preparations isolated by ion-exchange or protein G affinity chromatography differ in their glycosylation profiles.

IgG from patients with rheumatoid arthritis (RA) is abnormally glycosylated in the Fc region, with sialic acid and galactose levels lower than normal. Protein G and DEAE purify populations which are differentially glycosylated. Significantly increased exposure of sialic acid was detected in normal IgG compared with that of RA IgG when ion exchange was used to prepare samples. However, when the same samples were prepared using protein G, no difference in the detection of sialic acid was seen between the two groups. When examining the heavy chain of IgG, more sialic acid, galactose and N-acetylglucosamine were detected in DEAE purified IgG compared with that prepared by protein G Detection of sialic acid and N-acetylglucosamine was also increased on light chains from IgG prepared by ion exchange chromatography. Since this occurs notably on rheumatoid light chains it would appear that this arrangement would contribute to the overall glycosylation changes in IgG. In the case of molecules lacking galactose the discrimination between the RA and normal IgG is significantly improved when ion exchange chromatography is used. Since differentiation between disease and normal groups relies on the purification technique used, we recommend that more than one method is employed before undertaking an analysis of glycosylation changes.

Arthritis, Rheumatoid↗

Water sorption and mechanical properties of dental composites.

The physical properties of four commercial dental composites were investigated through differential scanning calorimetry, water sorption and desorption measurements and flexural mechanical properties tests. The differential scanning calorimetry curves of samples as prepared and after different times of ageing in water indicated that the small residual monomer reactivity, present in the as prepared samples, disappeared after immersion in water, which probably acts as a plasticizer and facilitates a further crosslinking reaction of the material and the residual monomer desorption. Consistently, water causes the embrittlement of the material, as detected from the flexural mechanical properties. Water sorption and desorption kinetics were measured at different temperatures, the water diffusion coefficients were calculated and the activation energies of the diffusion process were determined. The SEM analysis of the fracture surfaces and the decrease of the water uptake on the temperature indicated the existence of a good filler/matrix adhesion.

Adsorption↗