Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “diagnostic performance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 973 records · Page 54Linked to original sources

[Diagnosis of hypertrophic cardiomyopathy. Validation of criteria using genetics].

Our understanding of the genetics of hypertrophic cardiomyopathy has progressed significantly over the last few years. Seven genes have been identified as being responsible for familiar forms of the disease. This information has been useful, mainly in the elucidation of the physiopathology but clinical implications are also beginning to see the light of day. One example is the assessment of the pertinence of traditional diagnostic criteria. The originality of these studies lies in the analysis of familial hypertrophic cardiomyopathies in which the causal mutation has been identified, using the genetic status of the individual as the reference. The conventional diagnostic criteria then appear to be very specific but not very sensitive, inciting further analysis of additional criteria which might improve the diagnostic performance of routine investigations. This also opens the door to a comprehensive revision of the diagnostic criteria of this disease.

Cardiomegaly↗

Proposed: improve efficiency, reimbursement and LOS through better utilization of inpatient imaging procedures.

In recent years, most hospitals have gone through several rounds of cost cutting initiatives. While it is necessary and prudent to closely monitor operating costs and staff utilization, the focus needs to shift from cutting cost to increasing revenue. This study examines the potential financial benefit of performing diagnostic imaging procedures that are ordered on inpatients the day of, or the day prior to discharge as outpatient exams, following discharge. While this analysis focuses on revenue enhancement, it will not lose site of the fact that patient safety and quality clinical care always come first. We selected three imaging modalities for study: CT, MR and nuclear cardiology. These modalities are unique because of their expensive nature, length of time to complete, and limited availability. Also, they typically yield the highest reimbursement per procedure when compared to other diagnostic imaging procedures. Yearly volume at North Shore University Hospital for CT, MR and nuclear cardiology studies performed on the day of or day before discharge is projected to be 1,120 studies. Sixty-two percent of the total is generated by nuclear stress tests, 34 percent by CT, and only 6 percent is related to MR. On an annual basis, approximately $840,800 in hospital charges will be generated for inpatient procedures performed on the day of or one day before discharge. Implementing change is a difficult and complicated process. The following are among many factors that must be carefully considered: physician education, consensus building, patient care guidelines, ongoing performance improvement activities and scheduling. This study focused on a small aspect of inpatient procedure utilization and identified reimbursement to the hospital. The most significant finding of this project relates to the fact that of the 323 CT and MR studies performed, 83 percent of the findings were positive, and the patients were still discharged. That fact further supports the concept of performing studies ordered on the day of or one day prior to discharge as outpatient procedures.

Ambulatory Care↗

Meta-DiSc: a software for meta-analysis of test accuracy data.

BACKGROUND: Systematic reviews and meta-analyses of test accuracy studies are increasingly being recognised as central in guiding clinical practice. However, there is currently no dedicated and comprehensive software for meta-analysis of diagnostic data. In this article, we present Meta-DiSc, a Windows-based, user-friendly, freely available (for academic use) software that we have developed, piloted, and validated to perform diagnostic meta-analysis. RESULTS: Meta-DiSc a) allows exploration of heterogeneity, with a variety of statistics including chi-square, I-squared and Spearman correlation tests, b) implements meta-regression techniques to explore the relationships between study characteristics and accuracy estimates, c) performs statistical pooling of sensitivities, specificities, likelihood ratios and diagnostic odds ratios using fixed and random effects models, both overall and in subgroups and d) produces high quality figures, including forest plots and summary receiver operating characteristic curves that can be exported for use in manuscripts for publication. All computational algorithms have been validated through comparison with different statistical tools and published meta-analyses. Meta-DiSc has a Graphical User Interface with roll-down menus, dialog boxes, and online help facilities. CONCLUSION: Meta-DiSc is a comprehensive and dedicated test accuracy meta-analysis software. It has already been used and cited in several meta-analyses published in high-ranking journals. The software is publicly available at http://www.hrc.es/investigacion/metadisc_en.htm.

Clinical Laboratory Techniques↗

Characteristics of p53 and Smad4 immunohistochemistry in pancreatic ductal adenocarcinoma and validation by next-generation sequencing.

BACKGROUND: Mutations in four major driver genes -KRAS, CDKN2A, TP53, and SMAD4- are central to the pathogenesis of pancreatic ductal adenocarcinoma (PDAC) and critically inform diagnosis, therapeutic decision-making, and prognostic assessment. Although next-generation sequencing (NGS) is widely regarded as the gold standard for detecting these mutations, its clinical application is often limited by suboptimal analytical efficiency and substantial economic cost. Among these genes, immunohistochemical (IHC) staining for the proteins encoded by TP53 and SMAD4 has been extensively adopted in routine pathology practice. However, standardized IHC pattern classification schemes and rigorous validation of their predictive accuracy for underlying genomic alterations remain lacking in PDAC. METHODS: We retrospectively enrolled 63 PDAC patients and systematically characterized the typical IHC expression patterns of p53 and Smad4. Targeted NGS was subsequently performed on all available tumor specimens, and the resulting mutational profiles were correlated with corresponding IHC findings. Diagnostic performance including sensitivity, specificity and accuracy of p53 IHC for predicting TP53 mutations and of Smad4 IHC for predicting SMAD4 mutations was rigorously evaluated. RESULTS: Among the four canonical driver genes, co-occurring double- or triple-gene mutations were prevalent; within TP53 and SMAD4, missense mutations constituted the most frequent variant type. Using NGS as the reference standard, we validated the diagnostic utility of a three-tiered p53 IHC classification system, particularly in fine-needle biopsy (FNB) specimens. Furthermore, we proposed a novel, refined Smad4 IHC pattern classification that incorporates an "intermediate" category, thereby expanding upon conventional binary interpretation. This new scheme achieved markedly improved mutation prediction accuracy (0.76) compared with traditional approaches (0.57). CONCLUSION: Our study highlights the complementary diagnostic value of p53 and Smad4 IHC relative to molecular testing in PDAC, especially when tissue is limited, as commonly encountered in FNB specimens. The newly established Smad4 IHC classification system, which integrates an intermediate expression category into the conventional two-tier framework, demonstrates superior clinical utility and enhances predictive accuracy for SMAD4 genomic alterations.

Humans↗

[Consultation (second opinion on biopsies) as an instrument of quality control in histopathologic diagnosis].

As the whole spectrum of morphological patterns encountered in surgical pathology cannot be, in its entirety, diagnosed correctly by a general pathologist alone, one has to seek consultation for difficult or unusual cases with specialised experts. In the Czech Republic, the consultation practice performed by specialists from different medical institutions is the only way to assess the quality of histopathological diagnostic performance, i.e. it represents an audit system. Audit systems functioning in other countries are described here. A proposal of a standard consultation process as well as problems concerning the financial costs and increased workload of consultants are discussed.

Biopsy↗

[Quality control of DNA testing in hereditary diseases].

The laboratories performing diagnostic studies regarding hereditary diseases and the specialists providing hereditary counselling are housed in clinical genetic centres. The laboratories are subject to the Special Medical Performances Act and have had licenses from the Ministry. The DNA diagnostic laboratories united in the National Committee on DNA Diagnostics, engaged among other things in quality control. The large number of tests requested and the dramatic consequences for the patient and his relatives necessitate high quality standards. The laboratories made a division of labour for analysis of most disorders, in order to acquire and maintain expertise in spite of rarity of most hereditary diseases. For adequate handling of requests for DNA diagnostic tests, it is important that the patient material be sent directly to the laboratory specialized in the disorders in question, for the request form to be filled out completely and for the patient data to be stated on the blood tube. A regularly updated review of the DNA diagnostics in the Netherlands can be found on the website: http://www.unimaas.nl/ approximately LOD/lod.htm. This list indications per centre and information such as required material and maximal results deadlines.

Genetic Diseases, Inborn↗

An educational intervention to improve diagnosis and management of suspicious skin lesions.

BACKGROUND: Family physicians have an important clinical role in assessment and management of suspicious skin lesions. As a result of a previous needs assessment study, an educational intervention based on audit and feedback with opportunity for reflection on practice was introduced to 46 family physicians randomly allocated to either an intervention (23) or control group (23). As an educational tool, audit allows doctors to systematically review their practice and establish the quality of care they provide. When combined with feedback and comparison of clinical performance with peers or standards, it has been shown to increase learning and change behavior. METHODS: Data based on their own patients, on the correlation between clinical and histologic diagnosis, and excisions of skin lesions were collated and reported to the intervention group. RESULTS: Despite randomization of the doctors, the patient population of doctors in the intervention and control groups were significantly different in key characteristics, including the types of skin lesions treated. The intervention group of doctors showed improved performance in providing clinical information on pathology requests and in adequate surgical excision of skin lesions. Diagnostic performance did not improve significantly, but physicians' certainty of diagnosis did. IMPLICATIONS: This study design has highlighted the difficulty in balancing the use of evidence-based educational strategies in an equivalent setting to normal practice with evaluation of performance using measures that include characteristics of practitioners' patients that cannot be controlled.

Adult↗

Single-photon emission tomography studies of rubidium-81 in the detection of ischaemic heart disease, using a stress-reinjection protocol.

The present study was designed to determine the feasibility of using single-photon emission tomography (SPET) imaging with rubidium-81 (T1/2 = 4.54 h) to detect ischaemic heart disease, using a stress-reinjection protocol and a specially constructed 511-keV hexagonal hole collimator for a standard gamma camera. The diagnostic performance of 81Rb SPET in detecting coronary artery disease (CAD) was investigated in 52 patients with a high prevalence of CAD. Coronary arteriography was performed in 34 patients, 25 of whom were classified as having significant stenosis (> or = 50%). At peak exercise (Cornell protocol), 111-222 MBq 81Rb was injected i.v. for stress imaging, and after 3 h of rest, 74-111 MBq was reinjected for rest imaging. The displayed short- and long-axis slices and the polar map images were interpreted qualitatively. In comparison to coronary arteriography, which served as the gold standard, the performance of 81Rb SPET revealed a sensitivity of 95% for the detection of CAD. Images of diagnostic quality were obtained in all patients, these being comparable to thallium-201 SPET images. In conclusion, these results indicate that the described method can be routinely used for the positron emitter 81Rb with a conventional gamma camera and special shielding. 81Rb has the well-known advantages of a potassium analogue and 81Rb SPET permits better visualization, particularly of the posterior wall of the myocardium, due to the higher photon energy. Considering the typical dose of 201Tl used for SPET (74-148 MBq), a 81Rb SPET scan imposes a significantly lower radiation burden on the patient.

Adult↗

Do technical parameters affect the diagnostic accuracy of virtual bronchoscopy in patients with suspected airways stenosis?

PURPOSE: Virtual bronchoscopy has gained popularity over the past decade as an alternative investigation to conventional bronchoscopy in the diagnosis, grading and monitoring of airway disease. The effect of technical parameters on diagnostic outcome from virtual bronchoscopy has not been determined. This meta-analysis aims to estimate accuracy of virtual compared to conventional bronchoscopy in patients with suspected airway stenosis, and evaluate the influence of technical parameters. MATERIALS AND METHODS: A MEDLINE search was used to identify relevant published studies. The primary endpoint was the "correct diagnosis" of stenotic lesions on virtual compared to conventional bronchoscopy. Secondary endpoints included the effects of the technical parameters (pitch, collimation, reconstruction interval, rendering method, and scanner type), and date of publication on the diagnostic accuracy of virtual bronchoscopy. RESULTS: Thirteen studies containing 454 patients were identified. Meta-analysis showed good overall diagnostic performance with 85% calculated pooled sensitivity (95% CI 77-91%), 87% specificity (95% CI 81-92%) and area under the curve (AUC) of 0.947. Subgroups included collimation of 3mm or more (AUC 0.948), pitch of 1 (AUC 0.955), surface rendering technique (AUC 0.935), and reconstruction interval of more than 1.25 mm (AUC 0.914). There was no significant difference in accuracy accounting for publication date, scanner type or any of the above variables. Weighted regression analysis confirmed none of these variables could significantly account for study heterogeneity. CONCLUSION: Virtual bronchoscopy performs well in the investigation of patients with suspected airway stenosis. Overall sensitivity and specificity and diagnostic odds ratio for diagnosis of airway stenosis were high. The effects of pitch, collimation, reconstruction interval, rendering technique, scanner type, and publication date on diagnostic accuracy were not significant.

Airway Obstruction↗

Quantitative clinical assessment of chronic anterior myocardial infarction with delayed enhancement magnetic resonance imaging and QRS scoring.

BACKGROUND: Both the regional and global myocardial extent of chronic myocardial infarction (MI) are important prognostic factors for length and quality of life and also crucial for the choice of therapy in patients with ischemic heart disease. Our aim was to develop and validate techniques for comparison between regional and global size of remote anterior MI in the left ventricle quantified with both magnetic resonance imaging (MRI) and electrocardiogram (ECG). METHODS: Delayed-enhancement (DE) MRI was used as a clinical "gold standard" for MI size to evaluate the extent of MI estimated with the commonly available standard 12-lead ECG. A method for comparing global and regional quantifications of MI with DE-MRI and ECG was developed. The Selvester QRS-scoring system was used for estimating MI size electrocardiographically. RESULTS: Twenty-five patients with chronic single anterior MI, documented with DE-MRI, were studied. The best agreement for mean % MI per regional segment of the left ventricle was found in the middle third (26% vs 27%), whereas the most significant discrepancy was found in the apex (56% vs 30%). The global MI size of the left ventricle averaged 21 +/- 9% with DE-MRI and 22% +/- 12% with ECG, with a correlation of r = 0.40 (P <.05). CONCLUSIONS: The current Selvester QRS scoring system performs well for quantifying anterior MI in the mid-regions of the left ventricle. The diagnostic performance of the Selvester QRS-scoring system for quantifying MI in the other regions, particularly the left ventricular apex, can potentially be improved, with DE-MRI as the gold standard.

Adult↗

Evaluation of alpha-fetoprotein assay in ascitic fluid for the diagnosis of hepatocellular carcinoma.

Ascites and hepatocellular carcinoma are frequently associated. We evaluated the usefulness of alpha-fetoprotein assay in ascitic fluid versus the serum assay, for the diagnosis of hepatocellular carcinoma, in 125 patients with peritoneal effusions (31 patients with hepatocellular carcinoma, 14 with extra-hepatic malignancies and 80 with a benign effusion). Albumin and total protein were also assayed and cytological analysis of the ascitic fluid performed. Alpha-fetoprotein appeared to be lower in ascitic fluid than in serum. For a diagnostic specificity of 95%, the thresholds were 18.9 microg/l in serum and 4 microg/l in ascitic fluid and the diagnostic sensitivity of alpha-fetoprotein was identical in serum and ascitic fluid (67.7%). Various ratios between alpha-fetoprotein and albumin or total protein did not enhance the diagnostic performance. Thus alpha-fetoprotein concentration in ascitic fluid reflected the serum concentration and proved to be of similar value for the diagnosis of hepatocellular carcinoma, providing that the appropriate thresholds are considered.

Adult↗

Speed kills? Speed, accuracy, encapsulations and causal understanding.

BACKGROUND: The role of basic science, which provides causal explanations for clinical phenomena in medical education, is poorly understood. Schmidt has postulated that expert clinicians maintain this knowledge in 'encapsulated' form, indexed by words or phrases describing the processes. In the present paper we show that students who learn causal explanations have a more coherent understanding of the relation between diseases and clinical features which, in turn, influences recognition of words or phrases describing 'encapsulated knowledge' and the ability to maintain performance under speeded conditions. HYPOTHESES: In comparison to students who simply learn the features of 4 diagnostic categories, students who learn a causal explanation will: (a) recognise words describing encapsulated knowledge more accurately and (b) maintain or improve diagnostic performance under speeded conditions. METHODS: Two studies were conducted involving 4 'pseudo-endocrinology' diseases and undergraduate psychology students. One group learned signs and symptoms alone; the second group also learned a causal explanation. In study 1, they were then given a recognition memory task. In study 2, they were asked to diagnose new cases either (i) as quickly as possible or (ii) taking their time. RESULTS: In study 1, while there was no difference in recognising old words (90% versus 91%), the causal group was better able to recognise encapsulated and novel consistent words (50% versus 41%) (P = 0.02). In study 2 there was an interaction; causal students performed better under speeded conditions (71% versus 66%) but worse under thoroughness conditions (67% versus 73%), as predicted. CONCLUSIONS: Causal understanding leads to more coherent understanding of clinical conditions, which in turn leads to expert-like behaviour.

Clinical Competence↗

Fractional flow reserve compared with intravascular ultrasound guidance for optimizing stent deployment.

BACKGROUND: Determination of fractional flow reserve (FFR) has been proposed as a means to assess stent deployment. In this prospective, multicenter trial, we evaluate the use of FFR to optimize stenting by comparing it with standard intravascular ultrasound (IVUS) criteria. METHODS AND RESULTS: Eighty-four stable patients with isolated coronary lesions underwent coronary stent deployment starting at 10 atm and increased serially by 2 atm until the FFR was >/=0.94 or 16 atm was achieved. IVUS was then performed. FFR was measured with a coronary pressure wire with intracoronary adenosine to induce hyperemia. The diagnostic characteristics of an FFR <0.94 to predict suboptimal stent expansion by IVUS, defined in both absolute and relative terms, were calculated. Over a range of IVUS criteria, the highest sensitivity, specificity, and predictive accuracy of FFR were 80%, 30%, and 42%, respectively. Receiver operator characteristic analysis defined an optimal FFR cut point at >/=0.96; at this threshold, the sensitivity, specificity, and predictive accuracy of FFR were 75%, 58%, and 62%, respectively (P=0.03 for comparison of predictive accuracy, P=0.01 for concordance between FFR and IVUS). The negative predictive value was 88%. Significantly better diagnostic performance was achieved in a subgroup that received higher doses (>30 microgram) of intracoronary adenosine during pressure measurements, suggesting that FFR might be overestimated in the other group. CONCLUSIONS: A fractional flow reserve <0.96, measured after stent deployment, predicts a suboptimal result based on validated intravascular ultrasound criteria; however, an FFR >/=0.96 does not reliably predict an optimal stent result. Higher doses of intracoronary adenosine than previously used to measure FFR improve these results.

Adenosine↗

Novel protein markers of acute coronary syndrome complications in low-risk outpatients: a systematic review of potential use in the emergency department.

BACKGROUND: Published literature was systematically reviewed to determine the diagnostic accuracy of new protein markers of acute coronary syndromes (ACS) in symptomatic outpatients at low risk of ACS and related complications comparable to patients evaluated in emergency department chest pain units. METHODS: Studies were identified by a MEDLINE (1966 to May week 3, 2005) search. Abstracts were reviewed for relevance, and manuscripts were included by the independent consensus of 2 observers based on explicit criteria restricting the analysis to studies relevant to screening ambulatory patients with symptoms suggesting ACS. Publication bias was identified by a modified funnel plot analysis [study size (y) vs the inverse of the negative likelihood ratio (x)]. Results of individual markers were reported separately. When 3 or more eligible studies were identified, data were aggregated by use of the summary ROC (SROC) curve. RESULTS: Twenty-two protein markers in 10 unique populations met the inclusion criteria. Data required for SROC analysis (true- and false-positive rates) were available for 17 markers, in 9 unique populations, from publications and personal communications. Of these, only C-reactive protein was published in more than 2 populations to allow aggregation (6 studies total). C-Reactive protein demonstrated poor diagnostic performance on SROC curve analysis, with an area under the curve of 0.61 and a pooled diagnostic odds ratio of 1.81 (95% confidence interval, 1.06-3.07). CONCLUSION: Published evidence is not sufficient to support the routine use of new protein markers in screening for ACS in the emergency department setting.

Acute Disease↗

The role of endoscopic ultrasound in the diagnosis and staging of pancreatic adenocarcinoma.

Pancreatic adenocarcinoma is the fifth leading cause of cancer-related death in the United States. Although spiral CT is the best noninvasive method for detecting pancreatic cancer, the sensitivity for small masses remains low. It is this group of patients with small masses who may most benefit from surgical resection. Endoscopic ultrasound employs the use of flexible endoscopic devices to perform diagnostic ultrasound imaging and is a more accurate means of detecting pancreatic tumors. The ability to perform cytological aspiration of pancreatic masses via EUS is also a major step in the diagnosis of pancreatic adenocarcinoma. This review article will summarize the role of endoscopic ultrasonography in the diagnosis and staging of pancreatic cancer as well as looking at its impact on the management of these malignancies. Additionally, we will discuss the utility of screening high-risk patients for pancreatic cancer using the tools that are currently available.

Adenocarcinoma↗

Efficacy of an intraperitoneal antibiotic to reduce the incidence of infection in the trauma patient: a prospective, randomized study.

BACKGROUND: Antibiotic therapy in patients with blunt trauma remains an area of investigation. This study was undertaken in trauma patients evaluated with diagnostic peritoneal lavage to determine the effect of an intraperitoneal antibiotic on the following factors: infectious complications, length of hospital stay, and mortality. METHODS: A prospective, randomized double-blinded study compared using either 500 mg of intraperitoneal kanamycin or a saline control in 69 adult trauma patients requiring diagnostic peritoneal lavage was conducted over a 24-month period. Advanced trauma life support indications for performing diagnostic peritoneal lavage were used. Patients were randomized to receive 50 mL of solution intraperitoneally through a lavage catheter and were evaluated for all septic complications, length of hospital stay, and outcome. RESULTS: Over a 24-month period, 40 patients received kanamycin, and 29 patients received a placebo. Of patients receiving kanamycin, 27.5 percent experienced infectious complications compared to 65.5 percent of the control patients (p = 0.001, chi-square analysis). The average length of stay in the intensive care unit was 4.18 days in the kanamycin group and 6.96 days in the control group (p = 0.04, chi-square analysis). The average length of stay was 12.32 days for patients receiving kanamycin and 17.36 days for the control group (p = 0.03, chi-square analysis). The mortality rate for each group was 13 percent. CONCLUSIONS: Intraperitoneal kanamycin given to trauma patients requiring diagnostic peritoneal lavage within the first three hours following injury reduces the incidence of infectious complications and shortens intensive care unit and hospital stay.

Abdominal Injuries↗

Improved immunodiagnosis of cystic hydatid disease by using a synthetic peptide with higher diagnostic value than that of its parent protein, Echinococcus granulosus antigen B.

The assays are used for the diagnosis of hydatid disease are still imperfect. The reported diagnostic sensitivity and specificity vary greatly depending on the panel of sera used, the laboratory conducting the assay, and, more critically, the antigen used. To contribute to its standardization, we have recently ranked the diagnostic performances of the major parasite antigens and the available synthetic peptides using a large collection of serum samples. That work showed that antigen B (AgB) possesses the highest diagnostic value among these antigens. In the present work we further dissected its antigenicity by analyzing the reactivity of the same panel of sera against a set of synthetic peptides spanning the sequence of both AgB subunits. The N-terminal extension of these subunits appeared to be immunodominant in human infections. A 38-mer peptide (p176) delineated from the N-terminal extension of the AgB/1 subunit performed in an enzyme-linked immunosorbent assay with a higher diagnostic sensitivity (80%) and specificity (94%) than native AgB, Ag5, or any other peptide antigen tested against this collection of serum samples. In view of its high diagnostic value and its nature as a well-defined reproducible antigen, p176 could conveniently be used as a reference standard antigen in the diagnosis of hydatid disease.

Amino Acid Sequence↗

[Performance study of teleradiology network systems with CRT monitors: ROC analysis of an observation study of simulated lung nodules].

PURPOSE: To evaluate the diagnostic performance of commercially available CRT monitors used in a teleradiology system by determining the rate of detection of simulated lung nodules. MATERIALS AND METHODS: Three types of CRT monitors were tested in the observation study. They had matrix sizes of 1024 x 768(16 inches, color), 1024 x 768(20 inches, color) and 1600 x 1125(24 inches, black and white). Twenty chest radiographs were obtained by Fuji computed radiography(FCR) of an anthropomorphic chest phantom with ten simulated nodules on its surface. These FCR films were digitized by a film digitizer with 125 DPI(1024 x 1024 matrix sizes)and 12 bit gray scales, and the image data were transferred from Shinshu University Hospital to other hospitals where interpretation was carried out by the radiologists. Ten radiologists of three hospitals were asked to interpret independently both the original FCR films and the images shown on the CRT monitors and to indicate the presence or absence of simulated nodules on the images by using a five-category rating scale. Receiver operating characteristics(ROC)curves were generated, and the results of interpretation on the FCR films and CRT monitors were compared. RESULTS: Performance of the all readers was slightly better with the CRT monitors than on the FCR films, although the differences were not statistically significant. There were no statistically significant differences in performance depending on the type of CRT monitor. CONCLUSION: Performance of the CRT monitors was comparable to that of FCR radiography in terms of interpreting the simulated lung nodules.

Computer Communication Networks↗